ZMYHES209M1HWiMAX Indoor VoIP IAD

MitraStar Technology Corporation
WiMAX Indoor VoIP IAD - FCC ID ZMYHES209M1H - MitraStar Technology Corporation
Click to zoom

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Nov 03, 2011
Application Purpose
Original Equipment
Date of Application
Nov 03, 2011
Equipment Note
WiMAX Indoor VoIP IAD
Frequency Range
2505.00000000 - 2685.00000000
Company
MitraStar Technology Corporation
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

www.huawei.com BM2022 WiMAX IEEE 802.16 Indoor CPE Copyright  2011 Huawei Technologies Co., LTD. Firmware Version V2.00 Edition 1, 4/2011 Default Login Details IP Address:http://192.168.1.1 Usernameadmin Password1234 HES-209M1H About This User's Guide BM2022 Users Guide 3 About This User's Guide Intended Audience This manual is intended for people who want to configure the Huawei BM2022 using the Huawei Web Configurator. You should have at least a basic knowledge of TCP/IP networking concepts and topology. Related Documentation  Quick Start Guide The Quick Start Guide is designed to help you get up and running right away. It contains information on setting up your network and configuring for Internet access. Support Disc Refer to the included CD for support documents.  Huawei Web Site Please refer to www.huawei.com for additional support documentation and product certifications.  Document Conventions Warnings and Notes These are how warnings and notes are shown in this Users Guide. Warnings tell you about things that could harm you or your BM2022. Note: Notes tell you other important information (for example, other things you may need to configure or helpful tips) or recommendations. Syntax Conventions  The product(s) described in this book may be referred to as the BM2022, the device, the system or the product in this Users Guide.  Product labels, screen names, field labels and field choices are all in bold font.  A key stroke is denoted by square brackets and uppercase text, for example, [ENTER] means the enter or return key on your keyboard.  Enter means for you to type one or more characters and then press the [ENTER] key. Select or choose means for you to use one of the predefined choices.  A right angle bracket ( > ) within a screen name denotes a mouse click. For example, TOOLS > Logs > Log Settings means you first click Tools in the navigation panel, then the Logs sub menu and finally the Log Settings tab to get to that screen.  Units of measurement may denote the metric value or the scientific value. For example, k for kilo may denote 1000 or 1024, M for mega may denote 1000000 or 1048576 and so on.  e.g., is a shorthand for for instance, and i.e., means that is or in other words. About This User's Guide BM2022 Users Guide 4 Icons Used in Figures Figures in this Users Guide may use the following generic icons. The BM2022 icon is not an exact representation of your product. Table 1 Common Icons BM2022 ComputerWireless Signal NotebookServerBase Station TelephoneSwitchRouter Internet CloudNetwork Cloud Safety Warnings BM2022 Users Guide 5 Safety Warnings For your safety, be sure to read and follow all warning notices and instructions.  Do NOT use this product near water, for example, in a wet basement or near a swimming pool.  Do NOT expose your device to dampness, dust or corrosive liquids.  Do NOT store things on the device.  Do NOT install, use, or service this device during a thunderstorm. There is a remote risk of electric shock from lightning.  Connect ONLY suitable accessories to the device.  Do NOT open the device or unit. Opening or removing covers can expose you to dangerous high voltage points or other risks. ONLY qualified service personnel should service or disassemble this device. Please contact your vendor for further information.  Make sure to connect the cables to the correct ports.  Place connecting cables carefully so that no one will step on them or stumble over them.  Always disconnect all cables from this device before servicing or disassembling.  Use ONLY an appropriate power adaptor or cord for your device. Connect it to the right supply voltage (for example, 110V AC in North America or 230V AC in Europe).  Do NOT remove the plug and connect it to a power outlet by itself; always attach the plug to the power adaptor first before connecting it to a power outlet.  Do NOT allow anything to rest on the power adaptor or cord and do NOT place the product where anyone can walk on the power adaptor or cord.  Do NOT use the device if the power adaptor or cord is damaged as it might cause electrocution.  If the power adaptor or cord is damaged, remove it from the device and the power source.  Do NOT attempt to repair the power adaptor or cord. Contact your local vendor to order a new one.Do not use the device outside, and make sure all the connections are indoors. There is a remote risk of electric shock from lightning.  Do NOT obstruct the device ventilation slots, as insufficient airflow may harm your device.Use only No. 26 AWG (American Wire Gauge) or larger telecommunication line cord.  Antenna Warning! This device meets ETSI and FCC certification requirements when using the included antenna(s). Only use the included antenna(s).  If you wall mount your device, make sure that no electrical lines, gas or water pipes will be damaged.  Make sure that the cable system is grounded so as to provide some protection against voltage surges. Your product is marked with this symbol, which is known as the WEEE mark. WEEE stands for Waste Electronics and Electrical Equipment. It means that used electrical and electronic products should not be mixed with general waste. Used electrical and electronic equipment should be treated separately. Contents Overview BM2022 Users Guide 7 Contents Overview Users Guide ........................................................................................................................... 15 Getting Started ...........................................................................................................................17 Introducing the Web Configurator ..............................................................................................21 Setup Wizard.............................................................................................................................. 27 Tutorials ...................................................…

Text truncated - open the document above for the full version.

Attestation Statements

Declaration Letter We, MitraStar Technology Corporation declares that device’s maximum ratio of DL:UL is 29:18. That means it can not support the higher ratio than 29:18. For example, 26:21. The radio can not be modified to higher ratio than 29:18 by any method. FCC ID: ZMYHES209M1H If you have any questions regarding the authorization, please don’t hesitate to contact us. Thank you! Sincerely yours, _________________________________ Wang Yi / EMC/Safety Engineering Section Manager MitraStar Technology Corporation 2011/11/2

Cover Letter(s)

Federal Communications Commission Authorization and Evaluation Division Confidentiality Request FCC ID: ZMYHES209M1H Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying this Application as outlined below: Schematics Block Diagram Part List/ Tune-Up Procedures / Operating description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely yours, __________________________________ Wang Yi / EMC/Safety Engineering Section Manager MitraStar Technology Corporation 2011/11/2

Cover Letter(s)

Power of Attorney To whom it may concern: We, MitraStar Technology Corporation hereby authorize BV CPS (H.K.) Ltd., Taoyuan Branch of Taiwan to act on our behalf in all matters relating to all processes required in the FCC Part 27M approval and any communication needed with the national authority. Any and all acts carried out by BV CPS (H.K.) Ltd., Taoyuan Branch of Taiwan on our behalf shall have the same effects as acts of our own. FCC ID: ZMYHES209M1H If you have questions regarding the authorization or need further information, please don’t hesitate to contact us. Thank you! Sincerely yours, __________________________________ Wang Yi / EMC/Safety Engineering Section Manager MitraStar Technology Corporation 2011/11/2

External Photos

Page 1 CONSTRUCTION PHOTOS OF EUT Page 2 Page 3

ID Label/Location Info

LABEL LOCATION The label will be permanently affixed at a conspicuous location on the device. LABEL Drawing

Internal Photos

Page 4 Page 5 Page 6 Page 7 Page 8 Page 9

RF Exposure Info

Report No.: SA110729E04 Report Format Version 4.0.0 1 RF EXPOSURE REPORT REPORT NO.: SA110729E04 MODEL NO.: HES-209M1H, BM2022 FCC ID: ZMYHES209M1H RECEIVED: July 29, 2011 TESTED: Sep. 28, 2011 ISSUED: Oct. 11, 2011 PREPARED BY: MitraStar Technology Corporation ADDRESS: No. 6, Innovation Road II, Hsinchu Science Park, Hsinchu 300, Taiwan (R.O.C.) ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory LAB ADDRESS: No. 81-1, Lu Liao Keng, 9th Ling,Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan This test report consists of 5 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product certification, approval, or endorsement by any government agency. The test results in the report only apply to the tested sample. Report No.: SA110729E04 Report Format Version 4.0.0 2 Table of Contents RELEASE CONTROL RECORD....................................................................................3 1. CERTIFICATION..............................................................................................4 2. RF EXPOSURE LIMIT.....................................................................................5 3. MPE CALCULATION FORMULA.....................................................................5 4. CLASSIFICATION............................................................................................5 5. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER...................5 Report No.: SA110729E04 Report Format Version 4.0.0 3 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED SA110729E04 Original release Oct. 11, 2011 Report No.: SA110729E04 Report Format Version 4.0.0 4 1. CERTIFICATION PRODUCT: WiMAX Indoor VoIP IAD BRAND: Mitrastar, Huawei MODEL NO.: HES-209M1H, BM2022 PREPARED BY: MitraStar Technology Corporation TEST SAMPLE: MASS-PRODUCTION TESTED: Sep. 28, 2011 STANDARD: FCC Part 2 (Section 2.1091) FCC OET Bulletin 65, Supplement C (01-01) IEEE C95.1 The above equipment (Model: HES-209M1H) has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. PREPARED BY : , DATE: Sep. 02, 2011 ( Claire Kaun, Specialist ) APPROVED BY : , DATE: Sep. 02, 2011 ( May Chen, Deputy Manager ) Report No.: SA110729E04 Report Format Version 4.0.0 5 2. RF Exposure Limit LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) FREQUENCY RANGE (MHz) ELECTRIC FIELD STRENGTH (V/m) MAGNETIC FIELD STRENGTH (A/m) POWER DENSITY (mW/cm 2 ) AVERAGE TIME (minutes) LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE 300-1500 ... ... F/1500 30 1500-100,000 ... ... 1.0 30 F = Frequency in MHz 3. MPE calculation Formula Pd = (Pout*G) / (4*pi*r2) where Pd = power density in mW/cm2 Pout = output power to antenna in mW G = gain of antenna in linear scale pi = 3.1416 r = distance between observation point and center of the radiator in cm 4. Classification The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So, this device is classified as a user stations. 5. Calculation result of maximum conducted power For channel bandwidth: 5MHz FREQUENCY BAND (MHz) MAX POWER (mW) ANTENNA GAIN (dBi) DISTANCE (cm) POWER DENSITY (mW/ cm 2 ) LIMIT (mW/cm 2 ) 2505~2680 442.6 5.9 20 0.343 1.00 For channel bandwidth: 10MHz FREQUENCY BAND (MHz) MAX POWER (mW) ANTENNA GAIN (dBi) DISTANCE (cm) POWER DENSITY (mW/ cm 2 ) LIMIT (mW/cm 2 ) 2505~2685 445.0 5.9 20 0.344 1.00

Test Report

Report No.: RF110729E04 1 Report Format Version 4.0.0 FCC TEST REPORT (PART 27) REPORT NO.: RF110729E04 MODEL NO.: HES-209M1H, BM2022 FCC ID: ZMYHES209M1H RECEIVED: July 29, 2011 TESTED: Sep. 28 to Oct. 04, 2011 ISSUED: Oct. 11, 2011 APPLICANT: MitraStar Technology Corporation ADDRESS: No. 6, Innovation Road II, Hsinchu Science Park, Hsinchu 300, Taiwan (R.O.C.) ISSUED BY : Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory LAB ADDRESS : No. 81-1, Lu Liao Keng, 9th Ling,Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan This test report consists of 81 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product certification, approval, or endorsement by TAF or any government agency. The test results in the report only apply to the tested sample. The test results in this report are traceable to the national or international standards. Report No.: RF110729E04 2 Report Format Version 4.0.0 TABLE OF CONTENTS RELEASE CONTROL RECORD.................................................................................4 1 CERTIFICATION..............................................................................................5 2 SUMMARY OF TEST RESULTS......................................................................6 2.1 MEASUREMENT UNCERTAINTY.......................................................................7 3 GENERAL INFORMATION...............................................................................8 3.1 GENERAL DESCRIPTION OF EUT.....................................................................8 3.2 DESCRIPTION OF TEST MODES.......................................................................9 3.2.1 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL......................10 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS.....................................12 3.4 DESCRIPTION OF SUPPORT UNITS...............................................................13 3.4.1 CONFIGURATION OF SYSTEM UNDER TEST................................................14 4 TEST TYPES AND RESULTS........................................................................15 4.1 OUTPUT POWER MEASUREMENT.................................................................15 4.1.1 LIMITS OF OUTPUT POWER MEASUREMENT...............................................15 4.1.2 TEST INSTRUMENTS.......................................................................................15 4.1.3 TEST PROCEDURES........................................................................................15 4.1.4 TEST SETUP.....................................................................................................15 4.1.5 EUT OPERATING CONDITIONS.......................................................................16 4.1.6 TEST RESULTS(MODE 1).................................................................................17 4.1.7 TEST RESULTS(MODE 2).................................................................................17 4.2 FREQUENCY STABILITY MEASUREMENT......................................................18 4.2.1 LIMITS OF FREQUENCY STABILIITY MEASUREMENT..................................18 4.2.2 TEST INSTRUMENTS.......................................................................................18 4.2.3 TEST PROCEDURE..........................................................................................19 4.2.4 TEST SETUP.....................................................................................................19 4.2.5 TEST RESULTS.................................................................................................20 4.3 EMISSION BANDWIDTH MEASUREMENT.......................................................21 4.3.1 LIMITS OF EMISSION BANDWIDTH MEASUREMENT....................................21 4.3.2 TEST INSTRUMENTS.......................................................................................21 4.3.3 TEST PROCEDURES........................................................................................21 4.3.4 TEST SETUP.....................................................................................................22 4.3.5 EUT OPERATING CONDITIONS.......................................................................22 4.3.6 TEST RESULTS(MODE 1).................................................................................23 4.3.7 TEST RESULTS(MODE 2).................................................................................27 4.4 CHANNEL EDGE MEASUREMENT..................................................................31 4.4.1 LIMITS OF CHANNEL EDGE MEASUREMENT................................................31 4.4.2 TEST INSTRUMENTS.......................................................................................31 4.4.3 TEST SETUP.....................................................................................................31 4.4.4 TEST PROCEDURES........................................................................................32 Report No.: RF110729E04 3 Report Format Version 4.0.0 4.4.5 EUT OPERATING CONDITION.........................................................................32 4.4.6 TEST RESULTS(MODE 1).................................................................................33 4.4.7 TEST RESULTS(MODE 2).................................................................................42 4.5 CONDUCTED SPURIOUS EMISSIONS............................................................51 4.5.1 LIMITS OF CONDUCTED SPURIOUS EMISSIONS MEASUREMENT.............51 4.5.2 TEST INSTRUMENTS.......................................................................................51 4.5.3 TEST PROCEDURE..........................................................................................52 4.5.4 TEST SETUP..............................…

Text truncated - open the document above for the full version.

Test Setup Photos

1 PHOTOGRAPHS OF THE TEST CONFIGURATION RADIATED EMISSION TEST

Contact Information

Applicant

Yi Wang(Section Manager)
[email protected]886-3-5777998Fax: 886-3-5788837

Technical Contact

Bureau Veritas CPS (H.K.) Ltd. Taoyuan BranchHank Chung
[email protected]886-3-593-5343

81-1, Lu Laio Keng, 9th Ling, Wu Lung Tsuen, Chiun · Hsinchu Hsien · Taiwan

Non-Technical Contact

Bureau Veritas CPS (H.K.) Ltd. Taoyuan BranchNatacha Chen
[email protected]886-3-3183232

Test Firm

Bureau Veritas CPS (H.K.) Ltd. Taoyuan BranchRichard Chen
[email protected]886-3-3183232Fax: 886 3 2115834

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
2272.50 GHz - 2.69 GHz445.00 mW9M68W7D2.5 ppm
Confidentiality
Long Term
Grant Notes
Power listed is the maximum combined conducted output power. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of �1.1307(b)(3).

Other Applications from MitraStar Technology Corporation

Wi-SUN Module - FCC ID ZMY-MIO6706 - MitraStar Technology Corporation
ZMY-MIO6706

Wi-SUN Module

May 17, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
ZMYAM525

MoCA to Wireless / Ethernet bridge

Feb 10, 2016

Equipment Class

DTS - Digital Transmission System
M4G-3401 LTE Outdoor CPE - FCC ID ZMYM4G3401 - MitraStar Technology Corporation
ZMYM4G3401

M4G-3401 LTE Outdoor CPE

Jan 29, 2015

Equipment Class

DTS - Digital Transmission System
M4G-641 LTE FDD MODULE - FCC ID ZMYM4G-641 - MitraStar Technology Corporation
ZMYM4G-641

M4G-641 LTE FDD MODULE

Dec 09, 2013

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
ZMYHES209M2W

WiMAX Indoor VoIP Wi-Fi IAD

Dec 14, 2011

Equipment Class

DTS - Digital Transmission System