Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. § 15.19 Labeling requirements. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. § 15.21 Information to user. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
Shenzhen Century Xinyang Tech Co., Ltd Agent Authorization Company: Shenzhen Century Xinyang Tech Co., Ltd Address: 3F, North Building, Bantian High-tech industrial Zone, No. 2 of Bell Road, Longgang, Shenzhen, Guangdong 518129, China Product Type: 300M Repeater Model Number(s): WD-R611U Product Description: 300M Repeater We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature:Date: 2021-01-11 Name: Wiley Tsai Title: Manager Company: Shenzhen Century Xinyang Tech Co., Ltd
Shenzhen Century Xinyang Tech Co., Ltd Date: 2021-01-18 Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Subject; Request for Confidentiality FCC ID: ZNPWD-R611UA To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure FCC Software Security Requirements for UNII devices In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuantto KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name:Wiley Tsai Title:Manager
Test Model No.: WD‐R611U Antenna 2 Antenna 1
Size: 15*27mm 300M Repeater Model:WD-R611U Input:220V 0.8A FCC ID:ZNPWD-R611UA MADE IN CHINA MAC:XXXXXXXXXXXX Shenzhen Century Xinyang Tech Co., Ltd Lable location
Test Model No.: WD‐R611U
FCC ID: ZNPWD-R611UA RF Exposure Evaluation Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposures 0.3–3.0 614 1.63 *(100) 6 3.0–30 1842/f 4.89/f *(900/f 2 ) 6 30–300 61.4 0.163 1.0 6 300–1500 f/300 6 1500–100,000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f 2 ) 30 30–300 27.5 0.073 0.2 30 300–1500 f/1500 30 1500–100,000 1.0 30 f = frequency in MHz Friis transmission formula: Pd = (Pout*G)/(4*pi*r 2 ) Where Pd = power density in mW/cm 2 , Pout = output power to antenna in mW; G = gain of antenna in linear scale, Pi = 3.1416; R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm 2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. Test Result of RF Exposure Evaluation Wireless function Output power to antenna (dBm) Antenna Gain(dBi) Output power to antenna (mW) Power Density at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 2.4GHz WiFi 24.49 5.00(MIMO) 281.190 0.17690 1.000 PASS
Global United Technology Services Co., Ltd. Report No.: GTSL202012000256F01 Authorized Signature: Robinson Luo Laboratory Manager This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 64 TEST REPORT Applicant: Shenzhen Century Xinyang Tech Co., Ltd Address of Applicant: 3F, North Building, Bantian High-tech industrial Zone, No. 2 of Bell Road, Longgang, Shenzhen, Guangdong 518129, China Manufacturer/Factory: Shenzhen Century Xinyang Tech Co., Ltd Address of Manufacturer/Factory: 3F, North Building, Bantian High-tech industrial Zone, No. 2 of Bell Road, Longgang, Shenzhen, Guangdong 518129, China Equipment Under Test (EUT) Product Name: 300M Repeater Model No.: WD-R611U FCC ID: ZNPWD-R611UA Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of sample receipt: Sep. 10, 2020 Date of Test: Sep. 10 – Dec. 17, 2020 Date of report issued: Dec. 17, 2020 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTSL202012000256F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 64 2 Version Version No. Date Description 00 Dec. 17, 2020 Original Prepared By: Date: Dec. 17, 2020 Project Engineer Check By: Date: Dec. 17, 2020 Reviewer Report No.: GTSL202012000256F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 64 3 Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2 VERSION .................................................................................................................................................. 2 3 CONTENTS .............................................................................................................................................. 3 4 TEST SUMMARY ..................................................................................................................................... 4 5 GENERAL INFORMATION ...................................................................................................................... 5 5.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 5 5.2 TEST MODE ........................................................................................................................................ 7 5.3 DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 7 5.4 DEVIATION FROM STANDARDS ............................................................................................................. 7 5.5 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................... 7 5.6 TEST FACILITY .................................................................................................................................... 7 5.7 TEST LOCATION ................................................................................................................................. 7 5.8 ADDITIONAL INSTRUCTIONS ................................................................................................................. 7 6 TEST INSTRUMENTS LIST ..................................................................................................................... 8 7 TEST RESULTS AND MEASUREMENT DATA .................................................................................... 10 7.1 ANTENNA REQUIREMENT ................................................................................................................... 10 7.2 CONDUCTED EMISSIONS ................................................................................................................... 11 7.3 CONDUCTED PEAK OUTPUT POWER .................................................................................................. 14 7.4 CHANNEL BANDWIDTH & 99% OCCUPY BANDWIDTH .......................................................................... 16 7.5 POWER SPECTRAL DENSITY ............................................................................................................. 22 7.6 BAND EDGES .................................................................................................................................... 28 7.6.1 Conducted Emission Method ..................................................................................................... 28 7.6.2 Radiated Emission Method ........................................................................................................ 33 7.7 SPURIOUS EMISSION ......................................................................................................................... 38 7.7.1 Conducted Emission Method ..................................................................................................... 38 7.7.2 Radiated Emission Method ........................................................................................................ 47 8 TEST SETUP PHOTO ............................................................................................................................ 64 9 EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 64 Report No.: …
Text truncated - open the document above for the full version.
Report No.: GTSL202012000256F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 31 of 64 Antenna 2: Test mode: 802.11b Lowest channel Highest channel Test mode: 802.11g Lowest channel Highest channel Report No.: GTSL202012000256F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 32 of 64 Test mode: 802.11n(HT20) Lowest channel Highest channel Test mode: 802.11n(HT40) Lowest channel Highest channel Report No.: GTSL202012000256F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 33 of 64 7.6.2 Radiated Emission Method Test Requirement: FCC Part15 C Section 15.209 and 15.205 Test Method: ANSI C63.10: 2013 Test Frequency Range: All of the restrict bands were tested, only the worst band’s (2310MHz to 2500MHz) data was showed. Test site: Measurement Distance: 3m Receiver setup: Frequency Detector RBW VBW Value Above 1GHz Peak 1MHz 3MHz Peak Average 1MHz 3MHz Average Limit: Frequency Limit (dBuV/m @3m) Value Above 1GHz 54.00 Average 74.00 Peak Test setup: Test Procedure: 1. The EUT was placed on the top of a rotating table 1.5 meters above the ground at a 3 meter camber. The table was rotated 360 degrees to determine the position of the highest radiation. 2. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower. 3. The antenna height is varied from one meter to four meters above the ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement. 4. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters and the rota table was turned from 0 degrees to 360 degrees to find the maximum reading. 5. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode. 6. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that did not have 10dB margin would be re-tested one by one using peak, quasi-peak or average method as specified and then reported in a data sheet. 7. The radiation measurements are performed in X, Y, Z axis positioning. And found the Y axis positioning which it is worse case, only the test worst case mode is recorded in the report. Test Instruments: Refer to section 6.0 for details Test mode: Refer to section 5.2 for details Test results: Pass Report No.: GTSL202012000256F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 34 of 64 Measurement data: All antennas have test, only the worst case ANT 1 report. Test mode: 802.11b Test channel: Lowest Peak value: Frequency (MHz) Read Level (dBuV) Antenna Factor (dB/m) Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) Limit Line (dBuV/m) Over Limit (dB) Polarization 2390.00 52.49 27.59 5.38 34.01 51.45 74.00 -22.55 Horizontal 2400.00 61.47 27.58 5.39 34.01 60.43 74.00 -13.57 Horizontal 2390.00 54.27 27.59 5.38 34.01 53.23 74.00 -20.77 Vertical 2400.00 63.44 27.58 5.39 34.01 62.40 74.00 -11.60 Vertical Average value: Frequency (MHz) Read Level (dBuV) Antenna Factor (dB/m) Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) Limit Line (dBuV/m) Over Limit (dB) Polarization 2390.00 39.14 27.59 5.38 34.01 38.10 54.00 -15.90 Horizontal 2400.00 47.51 27.58 5.39 34.01 46.47 54.00 -7.53 Horizontal 2390.00 40.85 27.59 5.38 34.01 39.81 54.00 -14.19 Vertical 2400.00 48.69 27.58 5.39 34.01 47.65 54.00 -6.35 Vertical Test mode: 802.11b Test channel: Highest Peak value: Frequency (MHz) Read Level (dBuV) Antenna Factor (dB/m) Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) Limit Line (dBuV/m) Over Limit (dB) Polarization 2483.50 53.16 27.53 5.47 33.92 52.24 74.00 -21.76 Horizontal 2500.00 49.02 27.55 5.49 29.93 52.13 74.00 -21.87 Horizontal 2483.50 55.51 27.53 5.47 33.92 54.59 74.00 -19.41 Vertical 2500.00 51.65 27.55 5.49 29.93 54.76 74.00 -19.24 Vertical Average value: Frequency (MHz) Read Level (dBuV) Antenna Factor (dB/m) Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) Limit Line (dBuV/m) Over Limit (dB) Polarization 2483.50 39.48 27.53 5.47 33.92 38.56 54.00 -15.44 Horizontal 2500.00 35.59 27.55 5.49 29.93 38.70 54.00 -15.30 Horizontal 2483.50 41.59 27.53 5.47 33.92 40.67 54.00 -13.33 Vertical 2500.00 37.39 27.55 5.49 29.93 40.50 54.00 -13.50 Vertical Report No.: GTSL202012000256F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 35 of 64 Test mode: 802.11g Test channel: Lowest Peak value: Frequency (MHz) Read Level (dBuV) Antenna Factor (dB/m) Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) Limit Line (dBuV/m) Over Limit (dB) Polarization 2390.00 51.00 27.59 5.38 34.01 49.96 74.00 -24.05 Horizontal 2400.00 59.82 27.58 5.39 34.01 58.78 74.00 -15.23 Horizontal 2390.00 52.90 27.59 5.38 34.01 51.86 74.00 -22.14 Vertical 2400.00 61.64 27.58 5.39 34.01 60.60 74.00 -13.41 Vertical Average value: Frequency (MHz) Read Level (dBuV) Ante…
Text truncated - open the document above for the full version.
Test Model No.: WD‐R611U Radiated Emission Conducted Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 281.00 mW |

Mesh
Equipment Class
DTS - Digital Transmission System
1200M Repeater