FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Xiamen Topstar Lighting Co., Ltd./
  3. ZPD-TSZ9BR30

ZPD-TSZ9BR30LED lamp

Xiamen Topstar Lighting Co., Ltd.
LED lamp - FCC ID ZPD-TSZ9BR30 - Xiamen Topstar Lighting Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 11, 2023
Application Purpose
Original Equipment
Date of Application
Dec 11, 2023
Equipment Note
LED lamp
Frequency Range
2412.00000000 - 2462.00000000
Company
Xiamen Topstar Lighting Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Self-ballastLEDlampUserInstruction I、ProductFeatures Compactstructureanddesign-small,lightweight,stylish Madewithhighqualitypartsandmaterials-highreliability Light-emittingelementsandpartsproducedwithnewmanufacturing technology–highlumenoutput TheLEDbulbscan'tbeusedinanydimmablecircuit II、Productdrawinganddimensions ModelInputPower (W) CCT(K) Lamp cap TSZ9BR30-LD01 1-CEC 120VAC50/60Hz9W2700-6500KE26 III、 Selectionandinstallationinstruction 1.Openproductpackagingandcheckifproductisintact,contactselleriffound damaged. 2.Checktoconfirmproductratedvoltageissameaslocalpowergridvoltage. 3.Switchofflightpower. 4.Holdbulbbyplastichousingandinstallintolightsocket. 5.Switchon/offasusualwhenpowerisconnected. IV、 Warning 1.Donotputindripping-wetenvironment. 2.Donottouchbulbwhenswitchedonashighsurfacetemperaturemay scorchandinjureskin. 3.Lumenoutputdropswhenbulbisusedbeyondratedlumenmaintenance period.Forbetterprotectionofyoureyesight,donotusebeyondrated periodandreplacebulbaccordingly. 4.UseinDampLocationsonly FCCWarning Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjectto thefollowingtwoconditions:(1)Thisdevicemaynotcauseharmful interference,and(2)thisdevicemustacceptanyinterferencereceived, includinginterferencethatmaycauseundesiredoperation. Anychangesormodificationsnotexpresslyapprovedbytheparty responsibleforcompliancecouldvoidtheuser'sauthoritytooperatethe equipment. NOTE:Thisequipmenthasbeentestedandfoundtocomplywiththelimits foraClassBdigitaldevice,pursuanttoPart15oftheFCCRules.These limitsaredesignedtoprovidereasonableprotectionagainstharmful interferenceinaresidentialinstallation.Thisequipmentgenerates,usesand canradiateradiofrequencyenergyand,ifnotinstalledandusedin accordancewiththeinstructions,maycauseharmfulinterferencetoradio communications.However,thereisnoguaranteethatinterferencewillnot occurinaparticularinstallation. Ifthisequipmentdoescauseharmfulinterferencetoradioortelevision reception, whichcanbedeterminedbyturningtheequipmentoffandon,theuseris encouragedtotrytocorrecttheinterferencebyoneormoreofthefollowing measures: --Reorientorrelocatethereceivingantenna. --Increasetheseparationbetweentheequipmentandreceiver. --Connecttheequipmentintoanoutletonacircuitdifferent fromthattowhichthereceiverisconnected. --Consultthedealeroranexperiencedradio/TVtechnicianforhelp. ThisequipmentcomplieswithFCCradiationexposurelimitssetforthforan uncontrolledenvironment.Thisequipmentshouldbeinstalledandoperated withminimumdistance20cmbetweentheradiatorandyourbody. ISEDStatement English:Thisdevicecontainslicence-exempttransmitter(s)/receiver(s)thatcomply withInnovation,ScienceandEconomicDevelopmentCanada’slicence-exemptRSS (s).Operationissubjecttothefollowingtwoconditions: (1)Thisdevicemaynotcauseinterference. (2)Thisdevicemustacceptanyinterference,includinginterferencethatmaycause undesiredoperationofthedevice. ThedigitalapparatuscomplieswithCanadianCANICES‐3(B)/NMB‐3(B). French:Cetappareilcontientdesémetteurs/récepteursexemptsdelicencequisont conformesauxRSSexemptésdelicenced'Innovation,SciencesetDéveloppement économiqueCanada. L'exploitationestsoumiseauxdeuxconditionssuivantes: (1)Cetappareilnedoitpasprovoquerd'interférences. (2)Cetappareildoitacceptertouteinterférence,ycomprislesinterférencessuscept iblesdeprovoquerunfonctionnementindésirabledel'appareil. l'appareilnumériqueduciemconformecanadienpeut‐3(b)/nmb‐3(b). Thisdevicemeetstheexemptionfromtheroutineevaluationlimitsinsection2.5of RSS102andcompliancewithRSS102RFexposure,userscanobtainCanadianinfo rmationonRFexposureandcompliance. cetappareilestconformeàl'exemptiondeslimitesd'évaluationcourantedanslase ction2.5ducnr-102etconformitéavecrss102del'expositionauxrf,lesutilisateur speuventobtenirdesdonnéescanadiennessurl'expositionauxchampsrfetlacon formité. ThisequipmentcomplieswithCanadaradiationexposurelimitssetforthforanunc ontrolledenvironment. Cetéquipementestconformeauxlimitesd'expositionauxrayonnementsduCanada établiespourunenvironnementnoncontrôlé. Thisequipmentshouldbeinstalledandoperatedwithminimumdistance20cmbetw eentheradiator&yourbody. Cetéquipementdoitêtreinstalléetutiliséàunedistanceminimalede20cmentrele radiateuretvotrecorps.

Attestation Statements

Xiamen Topstar Lighting Co., Ltd. Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 12/5/2023 U.S. Agent Designation Xiamen Topstar Lighting Co., Ltd. acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: ZPD-TSZ9BR30 ): Name and company of U.S. agent: Chargenetic, INC Physical U.S. address of agent: 10010 Nicollet Lake Ln, Katy, TX 77494, USA FRN of U.S. agent: 0033431669 Email address of U.S. agent: [email protected] Chargenetic, INC acknowledges their obligation to accept service of process on behalf of Xiamen Topstar Lighting Co., Ltd Xiamen Topstar Lighting Co., Ltd. with the FRN 0020969929 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Sincerely, Signature Nancy Na Certified engineer Xiamen Topstar Lighting Co., Ltd. Signature Vincent Shao CEO Chargenetic, INC 48_[model] US_Agent_2.911(d)(7)-U, V05

External Photos

Page1of3FCCID:ZPD-TSZ9BR30IC:23379-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity ExternalPhotosoftheEUT Fig.1 Fig.2 Page2of3FCCID:ZPD-TSZ9BR30IC:23379-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of3FCCID:ZPD-TSZ9BR30IC:23379-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6

ID Label/Location Info

Page1of1FCCID:ZPD-TSZ9BR30IC:23379-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LabelandLocation Size:L:3.5cm*W:3.0cm LabelLocation LEDlamp ModelNo.:TSZ9BR30-LD011-CEC FCCID:ZPD-TSZ9BR30 IC:23379-TSZ9BR30

Internal Photos

Page1of4FCCID:ZPD-TSZ9BR30IC:23379-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity InternalPhotosoftheEUT Fig.1 Fig.2 Page2of4FCCID:ZPD-TSZ9BR30IC:23379-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of4FCCID:ZPD-TSZ9BR30IC:23379-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of4FCCID:ZPD-TSZ9BR30IC:23379-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Antenna

RF Exposure Info

Page1of4FCCID:ZPD-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity MaximumPermissibleExposureReport 1.ProductInformation FCCID:ZPD-TSZ9BR30 EUT:LEDlamp TestModel:TSZ9BR30-LD011-CEC PowerSupply:Input:AC120V,60Hz,9W HardwareVersion:V1.0 SoftwareVersion:V1.0 Bluetooth FrequencyRange:2402MHz~2480MHz ChannelNumber:40channelsforBluetoothV5.0(DTS) ChannelSpacing:2MHzforBluetoothV5.0(DTS) ModulationType:GFSKforBluetoothV5.0(DTS) BluetoothVersion:V5.0 AntennaDescription:CeramicAntenna,1.2dBi(Max.) WIFI(2.4GBand) FrequencyRange:2412MHz~2462MHz ChannelSpacing:5MHz ChannelNumber:11Channelsfor20MHzbandwidth(2412~2462MHz) 7Channelsfor40MHzbandwidth(2422~2452MHz) ModulationType:IEEE802.11b:DSSS(CCK,DQPSK,DBPSK) IEEE802.11g:OFDM(64QAM,16QAM,QPSK,BPSK) IEEE802.11n:OFDM(64QAM,16QAM,QPSK,BPSK) AntennaDescription:CeramicAntenna,1.2dBi(Max.) Exposurecategory : Generalpopulation/uncontrolledenvironment EUTType:ProductionUnit DeviceType:MobileDevice Page2of4FCCID:ZPD-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 2.EvaluationMethod SystemsoperatingundertheprovisionsofFCC47CFRsectionshallbeoperatedinamannerthatensuresthatthe publicisnotexposedtoradiofrequencyenergylevelinexcessoftheCommission’sguidelines. Inaccordancewith47CFRFCCPart2SubpartJ,section2.1091thisdevicehasbeendefinedasmobiledevice wherebyadistanceof0.2mnormallycanbemaintainedbetweentheuserandthedevice,andbelowRFPermissible Exposurelimitshallcomplywith. InaccordancewithKDB447498D01forSimultaneoustransmissionMPEtestexclusionapplieswhenthesumofthe MPEratiosforallsimultaneoustransmittingantennasincorporatedinahostdevice,basedonthe calculated/estimated,numericallymodelledormeasuredfieldstrengthsorpowerdensity,is≤1.0.TheMPEratioof eachantennaisdeterminedattheminimumtestseparationdistancerequiredbytheoperatingconfigurationsand exposureconditionsofthehostdevice,accordingtotheratiooffieldstrengthsorpowerdensitytoMPElimit,atthe testfrequency.Eitherthemaximumpeakorspatiallyaveragedresultsfrommeasurementsornumericalsimulations maybeusedtodeterminetheMPEratios.SpatialaveragingdoesnotapplywhenMPEisestimatedusingsimple calculationsbasedonfar-fieldplane-waveequivalentconditions.Theantennainstallationandoperating requirementsforthehostdevicemustmeettheminimumtestseparationdistancesrequiredbyallantennas,inboth standaloneandsimultaneoustransmissionoperations,tosatisfycompliance. 3.Limit 3.1ReferEvaluationMethod ANSIC95.1–2019:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoElectric,Magnetic,and ElectromagneticFields,0Hzto300GHz FCCKDBpublication447498D01General1RFExposureGuidancev06:MobileandPortableDevicesRFExposure ProceduresandEquipmentAuthorizationPolicies. FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices. 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100)* (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/UncontrolledExposure 0.3–3.0 3.0–30 30–300 300–1500 1500–100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100)* (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequencyinMHz *=Plane-waveequivalentpowerdensity Page3of4FCCID:ZPD-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity 4.MPECalculationMethod PredicationofMPElimitatagivendistance Equationfrompage18ofOETBulletin65,Edition97-01 S=PG/4πR² Where:S=powerdensity P=powerinputtoantenna G=powergainoftheantennainthedirectionofinterestrelativetoanisotropicradiator R=distancetothecenterofradiationoftheantenna 5.AntennaInformation EUTcanonlyuseantennascertificatedasfollowsprovidedbymanufacturer; Internal/External Identification Antennatypeand antennanumber Operatefrequency band Maximumantenna gain Notes InternalCeramicAntenna2400MHz-2500MHz1.2dBi BT/WIFI Antenna 6.ConductedPower [BTLE] ModeChannelFrequency(MHz) PeakConductedOutputPower (dBm) GFSK 002402-0.80 192440-0.53 392480-0.36 [2.4GWLAN] ModeChannelFrequency(MHz) PeakConductedOutputPower (dBm) IEEE802.11b 1241214.32 6243714.08 11246213.76 IEEE802.11g 1241214.43 6243714.32 11246213.59 IEEE802.11nHT20 1241213.92 6243713.42 11246213.19 IEEE802.11nHT40 3242212.74 6243712.60 9246212.21 7.ManufacturingTolerance [BTLE] GFSK(Peak) ChannelChannel00Channel19Channel39 Target(dBm)000 Tolerance±(dB)1.01.01.0 Page4of4FCCID:ZPD-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity [2.4GWLAN] IEEE802.11b(Peak) ChannelChannel01Channel06Channel11 Target(dBm)14.014.013.0 Tolerance±(dB)1.01.01.0 IEEE802.11g(Peak) ChannelChannel01Channel06Channel11 Target(dBm)14.014.013.0 Tolerance±(dB)1.01.01.0 IEEE802.11n20(Peak) ChannelChannel01Channel06Channel11 Target(dBm)13.013.013.0 Tolerance±(dB)1.01.01.0 IEEE802.11n40(Peak) ChannelChannel03Channel06Channel09 Target(dBm)12.012.012.0 Tolerance±(dB)1.01.01.0 8.M…

Text truncated - open the document above for the full version.

Test Report

AntennaSpecification Manufacture:TUYA ProductName:CBLC9Antenna AntennaType:CeramicAntenna TestDate:2021.03.22 Testedby:Tiny Approvedby:Licco Content 1.GeneralDescription.................................................................................1 2.TestConfigurations...................................................................................2 2.1TestEnvironment............................................................................2 2.2TestEquipment...............................................................................2 2.3TestPrinciple...................................................................................2 3.TestResults..............................................................................................3 3.1GainandEfficiency..........................................................................3 3.2RadiationPattern............................................................................4 4.AntennaDimensions................................................................................6 5.EUTPhoto................................................................................................6 6.TestSetupPhoto......................................................................................6 1 1.GeneralDescription ManufacturerHangzhouTuyaInformationTechnologyCo.,Ltd Address Room701,Building3,MoreCenter,No.87GuDunRoad, Hangzhou,Zhejiang,China TestLocation Room106,Building3,LetongSciencePark,No.500, QiuyiRoad,BinjiangDistrict,Hangzhou ProductNameCBLC9Antenna Productmodel CBLC9 AntennaType CeramicAntenna TestItems Gain;Efficiency;RadiationPattern TestFrequency 2400-2500MHz TestStandard ANSI/IEEEStd149-1979 2 2.TestConfigurations 2.1TestEnvironment Temperature(°C)25 Humidity(%RH)60 AtmosphericPressure(kPa)100.5 2.2TestEquipment TestSystemTEM24Multi-probeMicrowaveChamber TestInstrumentAgilentE5071B 2.3TestPrinciple 3 3.TestResults 3.1GainandEfficiency Frequency(MHz)PeakGain(dBi)Efficiency(%) 24000.8249.43 24100.7849.43 24200.7848.42 24300.6748.19 24401.249.32 24501.1152 24600.9949.55 24700.6645.19 24800.241.11 24900.238.99 25000.4940.83 4 3.2RadiationPattern Phi02D Phi902D Theta902D 5 2400MHz3D 2450MHz3D 2500MHz3D 6 4.5.EUTPhoto 6.TestSetupPhoto

Test Report

Page1of27FCCID:ZPD-TSZ9BR30IC:23379-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity AppendixA RFTestDataforBLE(ConductedMeasurement) ProductName:LEDlamp TestModel:TSZ9BR30-LD011-CEC EnvironmentalConditions Temperature: 23.8  C RelativeHumidity: 52.1% ATMPressure: 100.0kPa TestEngineer: PaddiChen Supervisedby: LingZhu Page2of27FCCID:ZPD-TSZ9BR30IC:23379-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.1DTSBandwidth TestResult TestModeAntennaChannel DTSBW [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict BLE_1MAnt1 24020.7122401.6282402.3400.5PASS 24400.7162439.6282440.3440.5PASS 24800.7162479.6282480.3440.5PASS Page3of27FCCID:ZPD-TSZ9BR30IC:23379-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page4of27FCCID:ZPD-TSZ9BR30IC:23379-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Page5of27FCCID:ZPD-TSZ9BR30IC:23379-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.2OccupiedChannelBandwidth TestResult TestModeAntennaChannel OCB[MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict BLE_1MAnt1 24021.06232401.46652402.5288------ 24401.05942439.47072440.5301------ 24801.06102479.47032480.5313------ Page6of27FCCID:ZPD-TSZ9BR30IC:23379-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page7of27FCCID:ZPD-TSZ9BR30IC:23379-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Page8of27FCCID:ZPD-TSZ9BR30IC:23379-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.3MaximumPeakConductedOutputPowerande.i.r.p. TestResult TestModeAntennaChannelResult[dBm]Limit[dBm] Antenna gain [dBi] EIRP [dBm] EIRP Limit (dBm] Verdict BLE_1MAnt1 2402-0.80≤301.20.4036PASS 2440-0.53≤301.20.6736PASS 2480-0.36≤301.20.8436PASS Page9of27FCCID:ZPD-TSZ9BR30IC:23379-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page10of27FCCID:ZPD-TSZ9BR30IC:23379-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Page11of27FCCID:ZPD-TSZ9BR30IC:23379-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.4Maximumpowerspectraldensity TestResult TestModeAntennaChannelResult[dBm/3-100kHz]Limit[dBm/3kHz]Verdict BLE_1MAnt1 2402-15.87≤8.00PASS 2440-15.51≤8.00PASS 2480-15.41≤8.00PASS Page12of27FCCID:ZPD-TSZ9BR30IC:23379-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TestGraphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Page13of27FCCID:ZPD-TSZ9BR30IC:23379-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Page14of27FCCID:ZPD-TSZ9BR30IC:23379-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity A.5Bandedgemeasurements TestResult TestModeAntennaChNameChannelRefLevel[dBm]Result[dBm]Limit[dBm]Verdict BLE_1MAnt1 Low2402-1.74-59.05≤-21.74PASS High2480-1.04-58.84≤-21.04PASS Page15of27FCCID:ZPD-TSZ9BR30IC:23379-TSZ9BR30 ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheck…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 71FCC ID: ZPD-TSZ9BR30IC: 23379-TSZ9BR30 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity AppendixB RF Test Data for 2.4GWIFI(ConductedMeasurement) ProductName:LED lamp Test Model:TSZ9BR30-LD011-CEC EnvironmentalConditions Temperature: 23.8  C RelativeHumidity: 52.1% ATM Pressure: 10 0.0 kPa Test Engineer: Paddi Chen Supervisedby: Ling Zhu Page 2 of 71FCC ID: ZPD-TSZ9BR30IC: 23379-TSZ9BR30 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity B.1 DTS Bandwidth Test Result TestModeAntennaFreq(MHz) DTS BW [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict 11BAnt1 24129.0802407.4402416.5200.5PASS 24379.0002432.4802441.4800.5PASS 24629.0802457.4402466.5200.5PASS 11GAnt1 241216.3202403.8402420.1600.5PASS 243716.4002428.8002445.2000.5PASS 246216.3602453.8002470.1600.5PASS 11N20SISOAnt1 241217.6002403.2002420.8000.5PASS 243717.6002428.2002445.8000.5PASS 246217.6002453.2002470.8000.5PASS 11N40SISOAnt1 242236.0002404.1602440.1600.5PASS 243736.0802418.8402454.9200.5PASS 245235.6802434.1602469.8400.5PASS Page 3 of 71FCC ID: ZPD-TSZ9BR30IC: 23379-TSZ9BR30 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity Test Graphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Page 4 of 71FCC ID: ZPD-TSZ9BR30IC: 23379-TSZ9BR30 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 11G_Ant1_2412 11G_Ant1_2437 Page 5 of 71FCC ID: ZPD-TSZ9BR30IC: 23379-TSZ9BR30 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 11G_Ant1_2462 11N20SISO_Ant1_2412 Page 6 of 71FCC ID: ZPD-TSZ9BR30IC: 23379-TSZ9BR30 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 11N20SISO_Ant1_2437 11N20SISO_Ant1_2462 Page 7 of 71FCC ID: ZPD-TSZ9BR30IC: 23379-TSZ9BR30 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 11N40SISO_Ant1_2422 11N40SISO_Ant1_2437 Page 8 of 71FCC ID: ZPD-TSZ9BR30IC: 23379-TSZ9BR30 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 11N40SISO_Ant1_2452 Page 9 of 71FCC ID: ZPD-TSZ9BR30IC: 23379-TSZ9BR30 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity B.2 OccupiedChannelBandwidth Test Result TestModeAntennaFreq(MHz) OCB[MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict 11BAnt1 241212.3992405.83302418.2320------ 243712.4812430.79292443.2739------ 246212.5852455.74962468.3346------ 11GAnt1 241217.0622403.51282420.5748------ 243717.0932428.44752445.5405------ 246217.0792453.45262470.5316------ 11N20SISOAnt1 241217.9152403.06092420.9759------ 243717.8842428.07282445.9568------ 246217.9402453.04262470.9826------ 11N40SISOAnt1 242236.2852403.88282440.1678------ 243736.2682418.90342455.1714------ 245236.3092433.90302470.2120------ Page 10 of 71FCC ID: ZPD-TSZ9BR30IC: 23379-TSZ9BR30 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity Test Graphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Page 11 of 71FCC ID: ZPD-TSZ9BR30IC: 23379-TSZ9BR30 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 11G_Ant1_2412 11G_Ant1_2437 Page 12 of 71FCC ID: ZPD-TSZ9BR30IC: 23379-TSZ9BR30 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 11G_Ant1_2462 11N20SISO_Ant1_2412 Page 13 of 71FCC ID: ZPD-TSZ9BR30IC: 23379-TSZ9BR30 ShenzhenLCS ComplianceTestingLaboratoryLtd. Add : 101, 201 Bldg A & 301 Bldg C, Juji IndustrialPark Yabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel: +(86) 0755-82591330| E-mail:[email protected]| Web: www.lcs-cert.com Scan code to check authenticity 11N20SISO_Ant1_2437 11N20SI…

Text truncated - open the document above for the full version.

Test Report

Page1of34FCCID:ZPD-TSZ9BR30ReportNo.:LCSA10313061EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT For XiamenTopstarLightingCo.,Ltd. LEDlamp TestModel:TSZ9BR30-LD011-CEC Preparedfor:XiamenTopstarLightingCo.,Ltd. Address:676MeixiAvenue,Tong'anDistrict,Xiamen,Fujian,China Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:November02,2023 Numberoftestedsamples:2 SampleNo.:A10313061-1,A10313061-2 Serialnumber:Prototype DateofTest:November02,2023~November08,2023 DateofReport:November09,2023 Page2of34FCCID:ZPD-TSZ9BR30ReportNo.:LCSA10313061EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Nancy Na
[email protected]86-592-7263847Fax: 0592-7263702

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz27.70 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted. This device supports 802.11b, 802.11g and 802.11n with a 20 MHz and 40 MHz bandwidth mode. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from Xiamen Topstar Lighting Co., Ltd.

Tag - FCC ID ZPD-TSZPJD009 - Xiamen Topstar Lighting Co., Ltd.
ZPD-TSZPJD009

Tag

Sep 04, 2024

Equipment Class

DTS - Digital Transmission System
LED lamp - FCC ID ZPD-TSZ7FST19LD - Xiamen Topstar Lighting Co., Ltd.
ZPD-TSZ7FST19LD

LED lamp

Feb 26, 2023

Equipment Class

DTS - Digital Transmission System
CFL - FCC ID ZPD-BLTA15C-R30 - Xiamen Topstar Lighting Co., Ltd.
ZPD-BLTA15C-R30

CFL

Jul 16, 2011

Equipment Class

8CC - Part 18 Consumer Device
CFL - FCC ID ZPD-BLTA14-T3 - Xiamen Topstar Lighting Co., Ltd.
ZPD-BLTA14-T3

CFL

Jul 16, 2011

Equipment Class

8CC - Part 18 Consumer Device
CFL - FCC ID ZPD-BLTA26-PAR38 - Xiamen Topstar Lighting Co., Ltd.
ZPD-BLTA26-PAR38

CFL

Jul 16, 2011

Equipment Class

8CC - Part 18 Consumer Device