022311β6 PO Box 465 | 214 West Main Street | Ligonier| PA 15658-0465 | United Sta tes T: +1-724-238-2929|F: +1-724-238-2228 | E:in [email protected]|www.cniguard.com Authority to Act as Agent Date:January 6, 2012 American Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: RN Electronics Ltdis authorized to act on our behalf, until otherwise notified, for applications to AmericanCertification Body, Inc. (ACB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b),to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Expiration Date:December 31 st 2012 By: Chester Fisher (Signature 1 )(Print name) Title:COO On behalf of:CNIguard LLC (Company Name) Telephone:+1 724 238 2929 1 -Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.
022311β6 PO Box 465 | 214 West Main Street | Ligonier| PA 15658-0465 | United Sta tes T: +1-724-238-2929| F: +1-724-238-2228 | E:in [email protected]|www.cniguard.com Request for Confidentiality Date:January 6, 2012 Subject: Confidentiality Request for:ZRE3A001-0B1 Pursuant to FCC 47 CRF0.457(d) and 0.459 and IC RSP-100, Section 10, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality RequestedExhibit Short TermPermanentBlock Diagrams Short TermExternal Photos Short TermPermanent* 2 Internal Photos Short TermPermanentOperation Description/Theory of Operation Short TermPermanentParts List & Placement/BOM Short TermPermanentTune-Up Procedure Short TermPermanentSchematics Short TermTest Setup Photos Short TermPermanent*Installation Instructions CNIguardhas spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition"would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Note, the user/installation instructions are only given to professional installers & subject toNDAs.Note too that the equipment is installed inside hatches, at water treatment plants,which are locked and not normally accessible.In the event of anyunauthorized access, the deviceβs tamper alarm will be triggered. As this equipment is used in a security application (prevention of attacks on the water supply) werespectfullyrequest that the minimum amount of information is made public. Short-Term Confidentiality: Not applicable. NOTE for Industry Canada Applications: The applicant understands that until such time that IC distinguishes between Short Term and Permanent Confidentiality,either type ofmarked exhibitabovewill simply be marked Confidential when submitted to IC. Sincerely, By: Chester FisherCOO(Signature/Title 3 ) 2 -The asterisked items (*)require further justification before permanent confidentialitywill beallowed. These also currently require review by the FCC under theirPermit-But-Askpolicy before the grant is issued and can delay completion of an application.Further justification should be added to the note above. One such example for a potted device would be: βThe EUT is FULLY potted using a non-removable epoxy based material. Removal of potting material causes irreparable damage to internal circuitry. See photographs exhibits that outline thedevicebefore and after potting.β 3 -Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters shouldbe placed on appropriate letterhead.
PO Box 465 | 214 West Main Street | Ligonier | PA 15658-0465 | United States T: +1-724-238-2929 | F: +1-724-238-2228 | E: [email protected] | www.cniguard.com Cover Letter Date: April 27, 2012 American Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 RE: Certification Application FCC ID: ZRE3A001-0B1 To Whom It May Concern: Please be advised that confidentiality has been requested on certain aspects of this application, which it is understood are not routinely confidential: β Internal photographs β Installation instructions The device is not for consumers, but used in security applications such as protecting water installations from malicious contamination. The devices are not normally accessible as they are housed behind the locked hatches of the water installation that are only serviceable by the designated technicians. The installation instructions are technical documents not normally available to the user, but only the installer and only once a NDA has been signed, a copy of which is provided with this application. β Non Disclosure Agreement US EK 20110105 V002 R000.pdf β signed NDA 4 King Security.pdf Thank you for your attention to this matter. Yours faithfully By: S. J. Jeffreys (Print name) Title: VP Systems Engineering On behalf of: CNIGuard [email protected]
External Photographs
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Contains FCC ID:MIVGSM0308 Contains IC: 4160A-GSM0308 331-05-12
Label Location This device com plies w ith Part 15 of the FCC Ru les. Operation is subject to the follow ing tw o conditions: (1) This device m ay not cause harmful interference, and (2) this device m ust accept any interference received, includinginterference that m ay cause undesired operation. Contains FC C I D:MIVGSM0308 Contains IC: 4160A-GSM0308
FCC47CFRpart 15C Test Report For IDS-Controller SLC Reference Standard:FCC47CFRpart15C Manufacturer:CNIguard LLC For type of equipment and serial number, refer to section 3 Report Number:03-564/5019/1/12 Report Produced by:-R.N. Electronics Ltd. 1 Arnolds Court Arnolds Farm Lane Mountnessing Essex CM13 1UT U.K. www.RNelectronics.comTelephone+44 (0) 1277352219 Facsimile+44 (0) 1277 352968 electronics R N ο2012RN ELECTRONICS LIMITEDREPORT NUMBER03-564/5019/1/12 ALL RIGHTS RESERVED File nameCNIGUARD.5019.1.PUBLIC.DOCX The contents of this report, apart from the referenced ANSIC63.4-2003, are beyond the scope of UKAS Testing Laboratory No. 2360 accreditation. QMF21Jβ3;47CFR15C, RNE ISSUE 02JAN 2012PAGE2OF45 Copy No. pdf Arnolds Court, Arnolds Farm Lane, Mountnessing, Brentwood Essex, CM13 1UT Certificate of Test5019/1 The unit noted below has been tested byR.N. ElectronicsLimitedand, where appropriate, conforms to the relevant subpart of FCC 47CFR Part 15. This is a certificate of test only and should not be confused with an equipment authorisation. Other standards may also apply. Equipment:IDS-Controller Model Number:SLC Proposed FCC ID:ZRE3A001-0B1 Unique Serial Number:11100003 Manufacturer:CNIguard LLC PO Box 465 214 West Main Street Ligonier PA 15658-0465 United States Customer Purchase Order Number:Not stated Full measurement results are detailed in Report Number:03-564/5019/1/12 Test Standards:FCC 47CFR Part 15C effective dateOctober 1 st 2011, Class DXT Intentional Radiator NOTE: Certain tests were not performed based upon manufacturer's declarations. Certain other requirements aresubject to manufacturer declaration only and have not been tested/verified. For details refer to section 3 of this report. DEVIATIONS: Deviations from the standards have been applied. For details refer to section 4.2 of this report. This certificate relates only to the unit tested as identified by a unique serial number and in the condition at the time it was tested. It does not relate to any other similar equipment and performance of the product before or after the test cannot be guaranteed. Whilst every effort is made to assure quality of testing, type tests are not exhaustive and although no non-conformances may be found, this doesn't exclude the possibility of unit not meeting the intentions of the standard or the requirements of the Directive, particularly under different conditions to those during testing.Any compliance statements are made reliant on (a) the application of the product and use of the assigned band being acceptable to one or more national authorities within the EU and (b) the modes ofoperation as instructed to us by the Customer based on their specific knowledge of the application and functionality of the EUT. Statements of compliance, where measurements were made, do not include the measurement uncertainty. The measurement uncertainty, where stated, is the expanded uncertainty based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%. Date of Test:23/Mar/2012 to 24/Apr/2012 Test Engineer: Approved By: TechnicalDirector Customer Representative: electronics R N ο2012RN ELECTRONICS LIMITEDREPORT NUMBER03-564/5019/1/12 ALL RIGHTS RESERVED File nameCNIGUARD.5019.1.PUBLIC.DOCX The contents of this report, apart from the referenced ANSIC63.4-2003, are beyond the scope of UKAS Testing Laboratory No. 2360 accreditation. QMF21Jβ3;47CFR15C, RNE ISSUE 02JAN 2012PAGE3OF45 1.Contents 1.Contents...............................................................................................................3 2.Summary of test results........................................................................................4 3.Equipment Under Test (EUT)...............................................................................5 3.1EQUIPMENTSPECIFICATION...........................................................................................................................................5 3.2EUTCONFIGURATIONS FOR TESTING.........................................................................................................................5 3.3EUTMODES.......................................................................................................................................................................6 3.4EMISSIONSCONFIGURATION.........................................................................................................................................7 4.Specifications.......................................................................................................8 4.1DEVIATIONS........................................................................................................................................................................8 4.2TESTS ATEXTREMES OFTEMPERATURE&VOLTAGE..........................................................................................8 4.3MEASUREMENTUNCERTAINTIES.................................................................................................................................8 5.Tests, Methods and Results.................................................................................9 5.1CONDUCTED EMISSIONS..................................................................................................................................................9 5.2INTENTIONAL RADIATOR FIELDSTRENGTH............................................................................................................11 5.3RADIATED EMISSIONS...................................................................................................................................................12 5.4FREQUENCY STABILITY................................................................................................................................................14 5.5OCCUPIED BANDWIDTH AND BAND EDGE........................................................................................β¦
Text truncated - open the document above for the full version.
Test Set-Up Photographs 30MHzβ1GHz, Site M 1β18GHz, Site M 18-26.5GHz, Site M Conducted powerline emissions, Site F.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 902.0625 MHz - 927.9375 MHz | - |

CNIguard IDS Detector
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified