FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. CNIguard, LLC/
  3. ZRE3A004-0B1

ZRE3A004-0B1CNIguard IDS Detector

CNIguard, LLC
CNIguard IDS Detector - FCC ID ZRE3A004-0B1 - CNIguard, LLC
Click to zoom

Application Details

Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Date of Grant
May 07, 2012
Application Purpose
Original Equipment
Date of Application
May 02, 2012
Equipment Note
CNIguard IDS Detector
Frequency Range
902.06250000 - 927.93750000
Company
CNIguard, LLC
Country
United States

Documents & Files

Select a file to view

Attestation Statements

β†—

Cover Letter(s)

β†—
β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—
β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

PO Box 465 | 214 West Main Street | Ligonier | PA 15658-0465 | United States T: +1-724-238-2929 | F: +1-724-238-2228 | E: [email protected] | www.cniguard.com 7 th March 2012 To whom it may concern: Detector (ZRE3A004-0B1) Battery Power. We can confirm that the detector units are currently only operated from battery power. We understand that should these units be required to operate from DC input connected to AC mains, an appropriate change notice will need to be issued following the appropriate Conducted AC Emissions testing.

Cover Letter(s)

022311–6 PO Box 465 | 214 West Main Street | Ligonier| PA 15658-0465 | United Sta tes T: +1-724-238-2929| F: +1-724-238-2228 | E:in [email protected]|www.cniguard.com Request for Confidentiality Date:January 6, 2012 Subject: Confidentiality Request for:ZRE3A004-0B1 Pursuant to FCC 47 CRF0.457(d) and 0.459 and IC RSP-100, Section 10, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality RequestedExhibit Short TermPermanentBlock Diagrams Short TermExternal Photos Short TermPermanent* 2 Internal Photos Short TermPermanentOperation Description/Theory of Operation Short TermPermanentParts List & Placement/BOM Short TermPermanentTune-Up Procedure Short TermPermanentSchematics Short TermTest Setup Photos Short TermPermanent*Installation Instructions CNIguardhas spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition"would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Note, the user/installation instructions are only given to professional installers & subject toNDAs.Note too that the equipment is installed inside hatches, at water treatment plants,which are locked and not normally accessible.In the event of anyunauthorized access, the device’s tamper alarm will be triggered. As this equipment is used in a security application (prevention of attacks on the water supply) werespectfullyrequest that the minimum amount of information is made public. Short-Term Confidentiality: Not applicable. NOTE for Industry Canada Applications: The applicant understands that until such time that IC distinguishes between Short Term and Permanent Confidentiality,either type ofmarked exhibitabovewill simply be marked Confidential when submitted to IC. Sincerely, By: Chester FisherCOO(Signature/Title 3 ) 2 -The asterisked items (*)require further justification before permanent confidentialitywill beallowed. These also currently require review by the FCC under theirPermit-But-Askpolicy before the grant is issued and can delay completion of an application.Further justification should be added to the note above. One such example for a potted device would be: β€œThe EUT is FULLY potted using a non-removable epoxy based material. Removal of potting material causes irreparable damage to internal circuitry. See photographs exhibits that outline thedevicebefore and after potting.” 3 -Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters shouldbe placed on appropriate letterhead.

Cover Letter(s)

PO Box 465 | 214 West Main Street | Ligonier | PA 15658-0465 | United States T: +1-724-238-2929 | F: +1-724-238-2228 | E: [email protected] | www.cniguard.com Cover Letter Date: April 27, 2012 American Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 RE: Certification Application FCC ID: ZRE3A004-0B1 To Whom It May Concern: Please be advised that confidentiality has been requested on certain aspects of this application, which it is understood are not routinely confidential: βˆ‘ Internal photographs βˆ‘ Installation instructions The device is not for consumers, but used in security applications such as protecting water installations from malicious contamination. The devices are not normally accessible as they are housed behind the locked hatches of the water installation that are only serviceable by the designated technicians. The installation instructions are technical documents not normally available to the user, but only the installer and only once a NDA has been signed, a copy of which is provided with this application. βˆ‘ Non Disclosure Agreement US EK 20110105 V002 R000.pdf βˆ‘ signed NDA 4 King Security.pdf Thank you for your attention to this matter. Yours faithfully By: S. J. Jeffreys (Print name) Title: VP Systems Engineering On behalf of: CNIGuard [email protected]

Cover Letter(s)

022311–6 PO Box 465 | 214 West Main Street | Ligonier| PA 15658-0465 | United Sta tes T: +1-724-238-2929|F: +1-724-238-2228 | E:in [email protected]|www.cniguard.com Authority to Act as Agent Date:January 6, 2012 American Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: RN Electronics Ltdis authorized to act on our behalf, until otherwise notified, for applications to AmericanCertification Body, Inc. (ACB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b),to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Expiration Date:December 31 st 2012 By: Chester Fisher (Signature 1 )(Print name) Title:COO On behalf of:CNIguard LLC (Company Name) Telephone:+1 724 238 2929 1 -Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.

External Photos

Detector: System (detector, antenna, battery box andintruder sensor):

ID Label/Location Info

Revision Sheet Date DWG Number CNIguard Limited - Jubilee House - StanmoreHA7 4RY Tel:+44 (0)207 100 5678 Commercial in Confidence Title 1 2 Not to scale Model: SLDS/N: D09120001FCC ID: ZRE3A004-0B1IC: 10117B-3A0040B1 10mm 8mm 58mm 45mm D=Detector10=Year07=Month0001=Sequential number Paper: 100gsm Canon Extra White A4Font: Verdana BoldInk: Black 18/1/12 1031SLD-DRW-017 Detector Label 7mm This device complies with Part 15 of the FCCRules. Operation is subject to the followingtwo conditions: (1) This device may notcause harmful interference, and (2) thisdevice must accept any interference received,including interference that may causeundesired operation.

Test Report

File nameCNIGUARD.4751-1.PUBLICREPORT.DOCX The contents of this report, apart from the referenced ANSI C63.4-2003, are beyond the scope of UKAS Testing Laboratory No. 2360 accreditation. QMF21J–3;47CFR15C, RNE ISSUE 02JAN 2012PAGE1OF45 FCC47CFRpart 15C Test Report For CNIguard IDSDetector Unit Reference Standard:FCC47CFRpart15C Manufacturer:CNIguard Ltd For type of equipment and serial number, refer to section 3 Report Number:01-487/4751/1A/12 Supersedes report # 01-487/4751/1/12 Report Produced by:-R.N. Electronics Ltd. 1 Arnolds Court Arnolds Farm Lane Mountnessing Essex CM13 1UT U.K. www.RNelectronics.comTelephone+44 (0) 1277 352219 [email protected] This report is not to be reproduced by any means except in full and in anycase not without the written approval of R.N. Electronics Ltd electronics R N 2012RN ELECTRONICS LIMITEDREPORT NUMBER 01-487/4751/1A/12 ALL RIGHTS RESERVED File nameCNIGUARD.4751-1.PUBLICREPORT.DOCX The contents of this report, apart from the referenced ANSI C63.4-2003, are beyond the scope of UKAS Testing Laboratory No. 2360 accreditation. QMF21J–3;47CFR15C, RNE ISSUE 02JAN 2012PAGE2OF45 Copy No. pdf Arnolds Court, Arnolds Farm Lane, Mountnessing, Brentwood Essex, CM13 1UT Certificate of Test4751/1A The unit noted below has been tested byR.N. Electronics Limitedand, where appropriate, conforms to the relevant subpart of FCC 47CFR Part 15. This is a certificate of test only and should not be confused with an equipment authorisation.Other standards may also apply. Equipment:CNIguard IDS Detector Unit Model Number:SLD Proposed FCC ID:ZRE3A004-0B1 Unique Serial Number(s):D11050008, D11050009 Manufacturer:CNIguard Ltd Jubilee House Merrion Ave Stanmore HA7 4RY UK Customer Purchase OrderNumber:RN 004 Full measurement results are detailed in Report Number:01-487/4751/1A/12 Test Standards:FCC 47CFR Part 15C effective dateOctober 1 st 2011, Class DXT Intentional Radiator NOTE: Certain tests were not performed based uponmanufacturer's declarations. For details refer to section 3 of this report. This certificate relates only to the unit tested as identified by a unique serial number and in the condition at the time itwas tested. It does not relate to any other similar equipment and performance of the product before or after the test cannot be guaranteed. Whilst every effort is made to assure quality of testing, type tests are not exhaustive and although no non-conformances may be found, this doesn't exclude the possibility of unit not meeting the intentions of the standard or the requirements of the Directive, particularly under different conditions to those during testing.Any compliance statements are made reliant on (a) the application of the product and use of the assigned band being acceptable to one or more national authorities within the EU and (b) the modes of operation as instructed to us by the Customer based on their specific knowledge of the application and functionality of the EUT. Statements of compliance, where measurements were made, do not include the measurement uncertainty. The measurement uncertainty, where stated, is the expanded uncertainty based on a standard uncertainty multiplied by a coverage factor of k=2, providing a levelof confidence of approximately 95%. Date of Test:6-Jul-11 to 24-Apr-12 Test Engineer: Approved By: Technical Director Customer Representative: . electronics R N File nameCNIGUARD.4751-1.PUBLICREPORT.DOCX The contents of this report, apart from the referenced ANSI C63.4-2003, are beyond the scope of UKAS Testing Laboratory No. 2360 accreditation. QMF21J–3;47CFR15C, RNE ISSUE 02JAN 2012PAGE3OF45 1.Contents 1.Contents...............................................................................................................3 2.Summary of test results........................................................................................4 3.Equipment Under Test (EUT)...............................................................................5 3.1Equipment Specification...............................................................................................................5 3.2EUT Configurations for testing....................................................................................................5 3.3EUT Modes....................................................................................................................................6 3.4Emissions Configuration...............................................................................................................7 4.Specifications.......................................................................................................8 4.1Deviations.......................................................................................................................................8 4.2Tests at Extremes of Temperature & Voltage...........................................................................8 4.3Measurement Uncertainties.........................................................................................................8 5.Tests, Methods and Results.................................................................................9 5.1Conducted emissions...................................................................................................................9 5.2Intentional radiator field strength.................................................................................................9 5.3Radiated emissions.....................................................................................................................10 5.4Frequency stability......................................................................................................................12 5.5Occupied bandwidth and band edge........................................................................................12 6.Plots and Results...............................................................................................13 6.1Conducted …

Text truncated - open the document above for the full version.

Test Setup Photos

H-field pre-scanset-up photo: 30MHz–1GHz set-up: Above1GHz set-up:

Contact Information

Applicant

Mario Castellanos(COO)
[email protected]407-878-1365Fax: 407-878-1365

Test Firm

R.N. Electronics Ltd.Roger Ray
[email protected]44-1277-352219Fax: 44-1277-352968

Technical Specifications

#Rule PartsFrequency RangePower Output
115C902.0625 MHz - 927.9375 MHz-
Confidentiality
Long Term

Other Applications from CNIguard, LLC

CNIguard IDS Controller - FCC ID ZRE3A001-0B1 - CNIguard, LLC
ZRE3A001-0B1

CNIguard IDS Controller

Jun 05, 2012

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified