WOW Tech Canada Ltd. Covered Equipment Certification Attestation Letter 2/10/2026 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: ZUEMND2A WOW Tech Canada Ltd. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. WOW Tech Canada Ltd. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. WOW Tech Canada Ltd. (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Signed: Printed name: Eyal Bar Or Title: Director, Global Quality & Compliance Company Name: WOW Tech Canada Ltd. Date: 1/28/2026
WOW Tech Canada Ltd. * the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter 2/10/2026 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: ZUEMND2A FRN of Grantee: 0021055090 Per section 2.911(d)(7) of the FCC rules, WOW Tech Canada Ltd. (“the applicant”) certifies that the equipment for which authorization is sought is designated to the following U.S. agent* for service of process: Company Name: WOW Tech USA Ltd. FRN: 0033538497 Physical U.S. Company Address: 103 Foulk Road, Suite 202, Wilmington, Delaware, USA ,19803-3742 Agent name: Eyal Bar Or Agent Email Address: [email protected] The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: OR Agent Signed: Signed: Signed: Printed name: Eyal Bar Or Printed name: Eyal Bar Or Title: Director, Global Quality & Compliance Title: Director, Global Quality & Compliance Company Name: WOW Tech Canada Ltd. Company Name: WOW Tech USA Ltd. Date: 2/10/2026 Date: 2/10/2026
WOW Tech Canada Ltd. 2/10/2026 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 AUTHORITY TO ACT AS AGENT - FCC On our behalf, I appoint Harry Deng of DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch, to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in FCC regulations will have affixed to it a label identical to that submitted for approval with this application. In signing this letter, Applicant certifies that neither the applicant nor any party to the application is not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti- Drug Abuse Act of 1988, 21 U.S.C. § 862 because of a conviction for possession or distribution of a controlled substance. See 47 CFR 1.2002(b) for the definition of a "party" for these purposes. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko North America Inc., still resides still resides with us. Sincerely, Printed name: Eyal Bar Or
WOW Tech Canada Ltd. February 10, 2026 Nemko North America, Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 REQUEST FOR CONFIDENTIALITY - FCC FCC ID: ZUEMND2A Pursuant to Sections 0.457(d) and 0.459 of the Commission’s Rules and FCC Guidance document 726920, we hereby request permanent confidential treatment of exhibits identified as such in the table below and request they are permanently withheld from public review based on the documents containing trade secrets and proprietary information not customarily released to the public. The public disclosure of this information might be harmful to the applicant and provide unjustified benefits to its competitors. We also request short-term confidentiality on certain exhibits until the intended date of marketing as outlined below. We request the exhibits be withheld from public view for a period of 180 days. We attest marketing of the product will only commence after the period of short-term confidentiality expires, or if marketing is to commence before the requested number of days listed above, the grantee will inform Nemko to release the Short-Term Confidentiality information withheld on the FCC equipment authorization website. Exhibit Type of Confidentiality Requested Block Diagrams ☒ Permanent ☐ Short Term External Photos ------------------ ☒ Short Term Internal Photos ☐ Permanent* ☒ Short Term Operation Description ☒ Permanent ☐ Short Term Parts List & Placement/BOM ☒ Permanent ☐ Short Term Tune-Up Procedure ☐ Permanent ☐ Short Term Schematic Diagrams ☒ Permanent ☐ Short Term Test Setup Photos ------------------ ☒ Short Term User’s Manual ☐ Permanent* ☒ Short Term The asterisked items (*) require further information to be provided in this justification letter before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 D01 found at: https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. Note: any documents held under the Short-Term confidentiality will automatically become public after the requested time if an appropriate extension request has not been received. Any exhibits (i.e., schematic diagrams) that may have already been requested to have “Permanent” confidentiality as shown above need not be repeated under Short-Term confidentiality request. Sincerely, Signed: Printed name: Eyal Bar Or Title: Director, Global Quality & Compliance Company Name: WOW Tech Canada Ltd.
1. FCC, IC, HVIN Will be put in the marked places with below information by laser etch. Model No.:MND2A FCC ID: ZUEMND2A IC: 9804A-MND2A HVIN: MND2A Laser etch position 2. FCC and IC statements, the device is too small and not capable of providing information electronically. It is in the compliance and safety manual.
DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu District, Guangzhou, Guangdong, China Tel +86 20 6661 2000 Fax +86 20 6661 2001 https://www.dekra.com Report no.: 4949530.59 Page 1 / 8 Test report No: 4949530.59 TEST REPORT Electromagnetic Field Exposure (EMF) Identification of item tested Vibrating stroker Trademark Arcwave Model and /or type reference MND2A Marketing name Orbit FCC ID ZUEMND2A Features 5 Vdc, 2 A Applicant ́s name / address WOW Tech Canada Ltd., 1545 Carling Avenue, Suite 401. Ottawa, Ontario, K1Z 8P9, Canada Test method requested, standard KDB 447498 D01V06 FCC Part 1.1310 Verdict Summary COMPLIANCE Tested by (name & signature) Harry Deng Approved by (name & signature) Tim Yan Date of issue 2026-02-11 Report template No TRF_EMC 2017-06- FCC_Exposure DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu District, Guangzhou, Guangdong, China Tel +86 20 6661 2000 Fax +86 20 6661 2001 https://www.dekra.com Report no.: 4949530.59 Page 2 / 8 INDEX page General conditions ................................................................................................................................. 3 Uncertainty............................................................................................................................................. 3 Environmental conditions ....................................................................................................................... 3 Possible test case verdicts ..................................................................................................................... 3 Definition of symbols used in this test report .......................................................................................... 4 Abbreviations ......................................................................................................................................... 4 Document History .................................................................................................................................. 4 Remarks and Comments ....................................................................................................................... 4 1 General Information ........................................................................................................................ 5 1.1 General Description of the Item(s) ........................................................................................ 5 1.2 The environment(s) in which the EUT is intended to be used ............................................... 6 2 RF Exposure Evaluation .................................................................................................................. 7 2.1 Limits.................................................................................................................................... 7 2.2 Test Procedure ..................................................................................................................... 8 2.3 Test Result ........................................................................................................................... 8 DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu District, Guangzhou, Guangdong, China Tel +86 20 6661 2000 Fax +86 20 6661 2001 https://www.dekra.com Report no.: 4949530.59 Page 3 / 8 GENERAL CONDITIONS 1. This report is only referred to the item that has undergone the test. 2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies or Competent Authorities. 3. This document is only valid if complete; no partial reproduction can be made without previous written permission of DEKRA. 4. This test report cannot be used partially or in full for publicity and/or promotional purposes without previous written permission of DEKRA. 5. This report will not be used for social proof function in China market. UNCERTAINTY For all measurements where guidance for the calculation of the instrumentation uncertainty of a measurement is specified in EN 55016-4-2 (CISPR 16-4-2), EN/IEC 61000-4 series or a product standard, the measurement instrumentation uncertainty has been calculated and applied in accordance with these standards. Uncertainties have been calculated according to the DEKRA internal document. The reported expanded uncertainties are based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%. ENVIRONMENTAL CONDITIONS The climatic conditions during the tests are within the limits specified by the manufacturer for the operation of the EUT and the test equipment. The climatic conditions during the tests were within the following limits: Ambient temperature 15 °C – 35 °C Relative Humidity air 30% - 60% Atmospheric pressure 86 kPa – 106 kPa If explicitly required in the basic standard or applied product / product family standard the climatic values are recorded and documented separately in this test report. POSSIBLE TEST CASE VERDICTS Test case does not apply to test object N/A Test object does meet requirement P (Pass) / PASS Test object does not meet requirement F (Fail) / FAIL Not measured N/M DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu District, Guangzhou, Guangdong, China Tel +86 20 6661 2000 Fax +86 20 6661 2001 https://www.dekra.com Report no.: 4949530.59 Page 4 / 8 DEFINITION OF SYMBOLS USED IN THIS TEST REPORT Indicates that the listed condition, standard or equipment is applicable for this report/test/EUT. Indicates that the listed condition, standard or equipment is not applicable for this report/test/EUT. Decimal separator used in this report Comma (,) Point (.) ABBREVIATIONS For the purposes of the present document, the following abbreviations apply: EUT : Equipment Under Test QP : Quasi-Peak CAV : CISPR Av…
Text truncated - open the document above for the full version.
DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu District, Guangzhou, Guangdong, China Tel +86 20 6661 2000 Fax +86 20 6661 2001 https://www.dekra.com Report no.: 4949530.58 Page 1 / 49 Test report No: 4949530.58 TEST REPORT Radio Spectrum Matters (RF) Identification of item tested Vibrating stroker Trademark Arcwave Model and /or type reference MND2A Marketing name Orbit FCC ID ZUEMND2A Features 5 Vdc, 2 A Applicant ́s name / address WOW Tech Canada Ltd., 1545 Carling Avenue, Suite 401. Ottawa, Ontario, K1Z 8P9, Canada Test method requested, standard FCC CFR Title 47 Part15 Subpart C Section 15.247; KDB558074 D01v05r02 Verdict Summary COMPLIANCE Tested by (name & signature) Harry Deng Approved by (name & signature) Tim Yan Date of issue 2026-02-11 Report template No TRF_EMC 2017-06- FCC_Part15C_247 DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu District, Guangzhou, Guangdong, China Tel +86 20 6661 2000 Fax +86 20 6661 2001 https://www.dekra.com Report no.: 4949530.58 Page 2 / 49 INDEX page General conditions ................................................................................................................................. 3 Uncertainty............................................................................................................................................. 3 Environmental conditions ....................................................................................................................... 3 Possible test case verdicts ..................................................................................................................... 3 Definition of symbols used in this test report .......................................................................................... 4 Abbreviations ......................................................................................................................................... 4 Document History .................................................................................................................................. 4 Remarks and Comments ....................................................................................................................... 4 1 General Information ........................................................................................................................ 5 1.1 General Description of the Item(s) ........................................................................................ 5 1.2 Test data .............................................................................................................................. 6 1.3 The environment(s) in which the EUT is intended to be used ............................................... 6 1.4 Channel List ......................................................................................................................... 7 2 Description of Test Setup ................................................................................................................ 8 2.1 Operating mode(s) used for tests ......................................................................................... 8 2.2 Support / Auxiliary equipment / unit / software for the EUT ................................................... 8 2.3 Test Configuration / Block diagram used for tests................................................................. 8 3 Verdict summary section ................................................................................................................. 9 3.1 Standards ............................................................................................................................. 9 3.2 Deviation(s) from the Standard(s) / Test Specification(s) ...................................................... 9 3.3 Overview of results ............................................................................................................... 9 3.4 Measurement procedure .................................................................................................... 10 4 Transmitter Test Results ............................................................................................................... 11 4.1 AC Power Line Conducted Emission .................................................................................. 11 4.2 Emissions in non-restricted frequency bands ..................................................................... 14 4.3 Emissions in restricted frequency bands ............................................................................ 25 4.4 Band Edge ......................................................................................................................... 32 4.5 Duty cycle .......................................................................................................................... 35 4.6 DTS Bandwidth .................................................................................................................. 37 4.7 Fundamental emission output power .................................................................................. 40 4.8 Power Density .................................................................................................................... 43 5 Identification of the Equipment Under Test .................................................................................... 46 Annex 1 – Measurement Uncertainty .................................................................................................. 47 Annex 2 - Used Equipment .................................................................................................................. 48 Annex 3 - Test Photos ......................................................................................................................... 49 DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Block 5, No.3, Qiyun Road, Huangpu D…
Text truncated - open the document above for the full version.
Page | 1 Image of the Antenna & Specifications: Antenna Type: Integrated on the PCB (IFA PCB Trace 31 mm, 0.991 mm width) Mounting: PCB Trace Frequency range: 2.400 – 2.480 GHz Figure 1: Trace Antenna on PCBA Figure 2: Antenna 3D radiation pattern & simulation (2440 MHz) Page | 2 • Max Antenna Gain 2.48GHz: 2.67 dBi Frequency (MHz) Max Gain (dBi) 2402 2.54 2410 2.56 2420 2.57 2430 2.59 2440 2.61 2450 2.63 2460 2.64 2470 2.66 2480 2.67 • Manufacturer name: Shanghai Tomison Electronic Co.,Ltd. • Manufacturer address: Fengxian DistrictNo.1118 GongYe Rd, Shanghai
103 Foulk Road, Suite 202 · Wilmington, Delaware, 19803-3742 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 410.00 µW |
Thruster
Equipment Class
DTS - Digital Transmission SystemProstate Massager
Equipment Class
DTS - Digital Transmission System5 button universal remote
Equipment Class
DTS - Digital Transmission System
Wearable Vibrator
Equipment Class
DTS - Digital Transmission System
Vibrating massager
Equipment Class
DTS - Digital Transmission System