FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. YI ZHAO (SHENZHEN) CO., LIMITED./
  3. 2A25A-H16

2A25A-H16Office headset

YI ZHAO (SHENZHEN) CO., LIMITED.
Office headset - FCC ID 2A25A-H16 - YI ZHAO (SHENZHEN) CO., LIMITED.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Dec 11, 2022
Application Purpose
Original Equipment
Date of Application
Dec 11, 2022
Equipment Note
Office headset
Frequency Range
2402.00000000 - 2480.00000000
Company
YI ZHAO (SHENZHEN) CO., LIMITED.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

H16, HH16S, H16 Pro Office headset User Manual Language Guide English Français Deutsch Ɋɭɫɫɤɢɣ Español Italiano Português         JP EN FR DE RU ES IT PT ⤜露 岁露 䗞露 銯棴暅 䠑㣐ⵄ 蟎暅露 EN EKSAtelecom H16 Wireless Headset EKSA USB-A Bluetooth Adapter Type-C Charging Cable User Manual Package Contents Specifications  124 3 Product Name: 2IILFHKHDGVHW Bluetooth Version: 5.2 Driver Diameter: 40 mm ,PSHGDQFHȍ“ 6HQVLWLYLW\“G% Frequency Response: 20 Hz - 20 kHz Battery: 400 mAh / 3.7 V Charging Time: 2 hours 0XVLF7LPH§KRXUV YROXPH  7DON7LPH§KRXUV YROXPH  Effective Wireless Range: 15 m Net Weight: 150 g Product Overview  9 10 11 7 8 3 5 4 3 2 5 1 9 10 11 6 8 7 Type-C Charging Port Power Button Volume + / next track Volume - / previous track Microphone Mute Button LED Status Indicator /RQJ%RRP0LFURSKRQH 5RWDWDEOH Microphone Hole USB Adapter Removable Ear Shell USB TypeC Charging Cable 4 1 2 6 Operation Guide  ,QWKHVKXWGRZQVWDWHORQJSUHVVWKHSRZHUEXWWRQIRUDERXW VHFRQGVWRVWDUWWKHKHDGVHWDQGWKHEOXHOLJKWLVDOZD\VRQIRUVHFRQGV   ,QWKHSRZHURQVWDWHORQJSUHVVWKHSRZHUEXWWRQIRUDERXW VHFRQGVWRVKXWGRZQWKHUHGOLJKWLVDOZD\VRQIRUVHFRQGVDQGWKH headset is turned off. Note: The headset will shut down automatically in 10 minutes when there is no connection. Switch on/off Ǝ Ǝ Bluetooth Pairing Connection EKSA-H16  :KHQWKHSKRQHLVWXUQHG RIIORQJSUHVVWKHSRZHU EXWWRQIRUDERXWVHFRQGVWR turn on the phone. The blue light and red light flash DOWHUQDWHO\DQGWKHKHDGVHW enters the pairing state. ,IQRFRQQHFWLRQLVVXFFHVVIXODIWHUSRZHURQLWZLOODXWRPDWLFDOO\HQWHUWKH pairing state.  :KHQWKHKHDGVHWLVGLVFRQQHFWHGLWZLOODXWRPDWLFDOO\HQWHUWKHSDLULQJVWDWH  7XUQRQWKH%OXHWRRWKRIWKHGHYLFHVHDUFKIRUWKH%OXHWRRWKKHDGVHWDQG WKHQVHOHFW(.6$+IRUSDLULQJFRQQHFWLRQ$IWHUWKHFRQQHFWLRQLV VXFFHVVIXOWKHKHDGVHWSURPSWV&RQQHFWHGDQGWKHEOXHOLJKWIODVKHVRQFH every 10s. The device displays that the Bluetooth headset is connected. Note: ,I\RXQHHGWRFRQQHFWDQHZGHYLFH\RXQHHGWRGLVFRQQHFWWKH%OXHWRRWKFRQQHFWLRQIURP WKHFRQQHFWHGGHYLFHILUVWDQGWKHKHDGVHWZLOODXWRPDWLFDOO\HQWHUWKHSDLULQJVWDWHWKHQXVHWKH new device to search for Bluetooth and complete the connection with the headset. (DFKWLPHWKHKHDGVHWLVWXUQHGRQLWZLOODXWRPDWLFDOO\VHDUFKIRUDQGFRQQHFWWRWKHQHDUHVW connected device. :KHQWKHSKRQHLVWXUQHGRQ H[FHSWIRUWKHFDOO SUHVVDQGKROGWKHYROXPHXSNH\DQG YROXPHGRZQNH\IRUVHFRQGVDWWKHVDPHWLPHDQGWKHUHGDQGEOXHOLJKWVIODVKRQFHDWWKH VDPHWLPHWRFOHDUDOOSDLULQJLQIRUPDWLRQLQWKHKHDGVHW$IWHUWKHSDLULQJUHFRUGLVFOHDUHGWKH SUHYLRXVGHYLFHFDQQRWEHFRQQHFWHGDIWHUWKHSKRQHLVWXUQHGRQDJDLQDQG\RXQHHGWRSDLU and connect again.   ̃  USB Adapter Connection PC: USB-A interface Type-C interface (Not included)  ,QVHUWWKH86%DGDSWHULQWRWKHFRPSXWHUWKHDGDSWHUZLOODXWRPDWLFDOO\ VWDUWXSDQGGLVSOD\(.6$3&$GDSWHURQWKHFRPSXWHUDQGWKHEOXH/(' of the adapter will slowly flash into the pairing state.  7XUQRQWKHKHDGVHWDQGWKHKHDGVHWDQGDGDSWHUZLOODXWRPDWLFDOO\FRQQHFW successfully. Note: A computer with Bluetooth function can have Bluetooth connection and USB adapter connection at the same time; Select one of the connection methods by switching the audio driver. Select the audio driver with the name of EKSA-H16 for Bluetooth connection, and select the audio driver with the name of EKSA PC Adapter for USB adapter connection.  $IWHUVXFFHVVIXOFRQQHFWLRQWKHKHDGVHWEOXHOLJKWIODVKHVRQFHHYHU\ VHFRQGVDQGWKHDGDSWHUEOXHOLJKWUHPDLQVRQ USB-A interface Indicator flashes in blue light Type-C interface Indicator flashes in blue light (Not included)  USB Adapter Connection Windows®: Microphone Settings: macOS: Audio Settings: [Control Panel] [Hardware and Sound] [Sound] [Playback] >(.6$3&$GDSWHU 6HWDV'HIDXOW'HYLFH @ [Control Panel] [Hardware and Sound] [Sound] [Recording] >(.6$3&$GDSWHU 6HWDV'HIDXOW'HYLFH @ [System Preferences][Sound] [Input][EKSA PC Adapter ] [EKSA PC Adapter ][Output] One to Two Bluetooth Connection EKSA-H16 0''  )LUVWFRQQHFWWKHKHDGVHWWRGHYLFH$WKURXJK%OXHWRRWKSDLULQJDQGWKHQ WXUQRIIGHYLFH$$WWKLVWLPHWKHKHDGVHWLVGLVFRQQHFWHGDQGHQWHUVSDLULQJ mode.  7KHQRSHQGHYLFH%DQGVXFFHVVIXOO\FRQQHFWZLWKWKHKHDGVHWWKURXJK Bluetooth search pairing.  7XUQRQGHYLFH$DJDLQDQGWKHQFRQQHFWWKHKHDGVHWWKURXJKGHYLFH$ $IWHUWKHFRQQHFWLRQLVVXFFHVVIXOWKHKHDGVHWZLOOEHFRQQHFWHGWRGHYLFH$ and device B at the same time.  device A device A device B device B The headset supports the simultaneous connection of two devices via Bluetooth. The specific steps are as follows: Note: The headset is connected to two devices at the same time. Only one of the devices works when using it. When the other device needs to be used, the currently working device needs to be suspended. Call Functions x1 Answer Reject Double Click x1 x1 Click Press for 2 seconds Click Hang up Amy Redial: Call Handling: Redial your last call number Ǝ x2  270° Triple Click Siri Voice dialing: :KHQFRQQHFWHG click the power key three times for voice dialing. x3 Mute Off Mute On Mute Off Mute On x1 Call Functions Three-Way Calling: Amy 00:10 On the phone New call Tom "NZ x1 Click x2 Double Click Press for 1 seconds Ǝ Answer a new call and hang up your current call Tom AmyTomAmyTomAmy Keep your current call and reject a new call TomAmy Keep your current call Answer a new call Three-way calling mode During a three-way call Switch between two calls  x2 Double Click I 7"  3OXJLQWKH86%7\SH&FKDUJLQJFDEOHIRUFKDUJLQJUHVHWWKHKHDGVHWDQG WXUQLWRIIDXWRPDWLFDOO\HQWHUWKHFKDUJLQJVWDWHWKHUHGOLJKWLVDOZD\VRQZKHQ FKDUJLQJDQGWKHEOXHOLJKWLVDOZD\VRQZKHQIXOO\…

Text truncated - open the document above for the full version.

Attestation Statements

YI ZHAO (SHENZHEN) CO., LIMITED Model difference statement Product Name: Office headset Model N o.: H16, H16S, H16 Pro We (YI ZHAO (SHENZHEN) CO., LIMITED., 6th Floor, T3 Creative Building, Creative Expo City, No.5010 Baoan Avenue, Hangcheng Street, Baoan Shenzhen, China) hereby state that all the models are the same circuit and module, except the model name. Signature: Name: Jenny Qiu Title: Purchasing Manager Tel: 0755-29082307 Email: [email protected] Date: 12.6.2022

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Letter of Authorization Company: YI ZHAO (SHENZHEN) CO., LIMITED. Address: 6th Floor, T3 Creative Building, Creative Expo City, No.5010 Baoan Avenue, Hangcheng Street, Baoan Shenzhen, China Product Name: Office headset Model Number: H16, H16S, H16 Pro FCC Identifier: 2A25A-H16 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Jenny Qiu Date: 12/6/2022 Title: Purchasing Manager Signature of applicant:

Cover Letter(s)

C5266091_X10_Ed.1 1/1 YI ZHAO (SHENZHEN) CO., LIMITED. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 12/6/2022 Subject: Request for Confidentiality FCC ID: 2A25A-H16 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality ID Label/Location No No Attestation Statement No No External Photos No Block Diagram Schematics Test Report No No Test Setup Photos No User’s Manual Internal Photos Parts List / Tune Up RF Exposure Info Operational Description Cover Letter(s) No No SDR Software / Security Info No Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Jenny Qiu Date: 12/6/2022 Title: Purchasing Manager

External Photos

Page 1 of 4 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Appendix - EUT Photos Model: H16 Photo 1 Photo 2 Page 2 of 4 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 3 Photo 4 Page 3 of 4 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 5 Photo 6 Page 4 of 4 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 7 Photo 8 ----End of Report----

ID Label/Location Info

H16-丝印文件 2022.11.17 Designer:Aiden 3 . 5 0 m m 3 . 5 0 m m THANKS www.eksa.net

Internal Photos

Page 1 of 3 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Appendix - EUT Photos Model: H16 Photo 1 Photo 2 ANT Page 2 of 3 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 3 Photo 4 Page 3 of 3 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Te l : (86-755)88850135 Fax: (86-755) 88850136 Web:www.mtitest.com E-mail: [email protected] Photo 5 ----End of Report----

RF Exposure Info

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] RF EXPOSURE Test Report Report No.: MTi221025004-01E2 Date of issue: 2022-11-30 Applicant: YI ZHAO (SHENZHEN) CO., LIMITED Product name: Office headset Model(s): H16, H16S, H16 Pro FCC ID: 2A25A-H16 Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 6- Report No.: MTi221025004-01E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Instructions 1. The report shall not be partially reproduced without the written consent of the laboratory; 2. The test results of this report are only responsible for the samples submitted; 3. This report is invalid without the seal and signature of the laboratory; 4. This report is invalid if transferred, altered or tampered with in any form without authorization; 5. Any objection to this report shall be submitted to the laboratory within 15 days from the date of receipt of the report. - Page 3 of 6- Report No.: MTi221025004-01E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] TEST RESULT CERTIFICATION Applicant’s name .................... : YI ZHAO (SHENZHEN) CO., LIMITED Address .................................. : 6th Floor, T3 Creative Building, Creative Expo City, No.5010 Baoan Avenue, Hangcheng Street, Baoan Shenzhen, China Manufacturer's Name ............. : YI ZHAO (SHENZHEN) CO., LIMITED Address .................................. : 6th Floor, T3 Creative Building, Creative Expo City, No.5010 Baoan Avenue, Hangcheng Street, Baoan Shenzhen, China Product description Product name ........................... : Office headset Trademark ............................. : EKSA Telecom Model Name .......................... : H16 Series Model ........................... H16S, H16 Pro Standards ............................... : N/A Test procedure ....................... : KDB 447498 D01 v06 Date of Test Date (s) of performance of tests ............ : 2022-11-21 ~ 2022-11-30 Test Result ............................................. : Pass Testing Engineer : (Letter Lan) Technical Manager : (Leon Chen) Authorized Signatory : (Tom Xue) - Page 4 of 6- Report No.: MTi221025004-01E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Table of Contents 1. STANDALONE SAR TEST EXCLUSION CONSIDERATIONS ............................................................................................ 5 2. SAR TEST EXCLUCSION THRESHOLDS ........................................................................................................................ 6 - Page 5 of 6- Report No.: MTi221025004-01E2 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China. Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] 1. Standalone SAR test exclusion considerations Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions. The minimum test separation distance defined in 4.1 f) is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander. To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified, typically in the SAR measurement or SAR analysis report, by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting are required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions. a) For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where  f (GHz) is the RF channel transmit frequency in GHz  Power and distance are rounded to the nearest mW and mm before calculation  The result is rounded to one decimal place for comparison  The values 3.0 and 7.5 are referred to as numeric thresholds in step b) below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm, and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 4.1 f) is applie…

Text truncated - open the document above for the full version.

Test Report

AntennaSpecific Model:H16 Manufacturer SKYWINGCommunicationElectronicsCo.,Ltd address No.62,10Rd,Longyan,HumenTown,DongguanCity, GuangdongProvince ProductType:MeanderLinePCBAntenna Technicalparameter ElectronicParameter FrequencyRange2400~2500MHz Inputimpedance50Ω VSWR≤2 GainMax0.83dBi PhysicalParameter MaterialPCB/Cu Operationtemperature-30°C~+80°C Storetemperature-30°C~+80°C AntennaSpecification:8.2mm*5mm*1.0mm TestResult: AntennaSpecifications FrequencyVNAETotal.dB(dB)Efficiency 2400MHz0.69399141.07% 2410MHz0.1433847.24% 2420MHz0.22305240.48% 2430MHz-0.1365933.93% 2440MHz0.3532637.82% 2450MHz0.73989442.77% 2460MHz0.8283852.67% 2470MHz0.64980941.93% 2480MHz-0.21593335.66% 2490MHz-0.47663934.62% 2500MHz0.71074140.22% Direction:

Test Report

Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Test Report Report No.: MTi221025004-01E1 Date of issue: 2022-11-30 Applicant: YI ZHAO (SHENZHEN) CO., LIMITED Product: Office headset Model(s): H16, H16S, H16 Pro FCC ID: 2A25A-H16 Shenzhen Microtest Co., Ltd. http://www.mtitest.com Page 2 of 65 Report No.: MTi221025004-01E1 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Instructions 1. This test report shall not be partially reproduced without the written consent of the laboratory. 2. The test results in this test report are only responsible for the samples submitted 3. This test report is invalid without the seal and signature of the laboratory. 4. This test report is invalid if transferred, altered, or tampered with in any form without authorization. 5. Any objection to this test report shall be submitted to the laboratory within 15 days from the date of receipt of the report. Page 3 of 65 Report No.: MTi221025004-01E1 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Table of contents 1 General Description ........................................................................................................................ 5 1.1 Description of the EUT ....................................................................................................................................... 5 1.2 Description of test modes ................................................................................................................................... 5 1.3 Test conditions .................................................................................................................................................... 7 1.4 Description of support units ................................................................................................................................ 7 2 Measurement uncertainty ............................................................................................................... 8 3 Summary of Test Result .................................................................................................................. 9 4 Test Laboratory ............................................................................................................................. 10 5 Equipment List .............................................................................................................................. 11 6 Test Result ..................................................................................................................................... 12 6.1 Antenna requirement ........................................................................................................................................ 12 6.2 AC power line conducted emissions................................................................................................................. 13 6.3 Radiated spurious emission ............................................................................................................................. 14 6.4 20dB emission bandwidth ................................................................................................................................ 23 6.5 Maximum conducted output power .................................................................................................................. 24 6.6 Carrier frequency separation ............................................................................................................................ 25 6.7 Time of occupancy............................................................................................................................................ 26 6.8 Number of hopping channels ........................................................................................................................... 27 6.9 Band edge (Conducted) ................................................................................................................................... 28 6.10 Conducted spurious emissions ...................................................................................................................... 29 Appendix A: 20dB Emission Bandwidth ............................................................................................. 30 Appendix B: Maximum conducted output power ............................................................................... 34 Appendix C: Carrier frequency separation ......................................................................................... 38 Appendix D: Time of occupancy ......................................................................................................... 40 Appendix E: Number of hopping channels......................................................................................... 47 Appendix F: Band edge measurements .............................................................................................. 49 Appendix G: Conducted Spurious Emission ...................................................................................... 54 Photographs of the Test Setup ............................................................................................................ 64 Photographs of the EUT....................................................................................................................... 65 Page 4 of 65 Report No.: MTi221025004-01E1 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xi…

Text truncated - open the document above for the full version.

Test Report

Page 36 of 65 Report No.: MTi221025004-01E1 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] 2DH5_Ant1_2480 3DH5_Ant1_2402 3DH5_Ant1_2441 Page 37 of 65 Report No.: MTi221025004-01E1 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] 3DH5_Ant1_2480 Page 38 of 65 Report No.: MTi221025004-01E1 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] APPENDIX C: CARRIER FREQUENCY SEPARATION Test Result Test Mode Antenna Frequency [MHz] Result [MHz] Limit [MHz] Verdict DH5 Ant1 Hop 1 ≥0.957 PASS 2DH5 Ant1 Hop 0.998 ≥0.900 PASS 3DH5 Ant1 Hop 1.002 ≥0.868 PASS Page 39 of 65 Report No.: MTi221025004-01E1 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Test Graphs DH5_Ant1_Hop 2DH5_Ant1_Hop 3DH5_Ant1_Hop Page 40 of 65 Report No.: MTi221025004-01E1 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] APPENDIX D: TIME OF OCCUPANCY Test Result Test Mode Antenna Frequency [MHz] BurstWidth [ms] Hops in 3.16s [Num] Result [s] Limit [s] Verdict DH1 Ant1 Hop 0.400 33 0.132 ≤0.4 PASS DH3 Ant1 Hop 1.657 16 0.265 ≤0.4 PASS DH5 Ant1 Hop 2.906 10 0.291 ≤0.4 PASS 2DH1 Ant1 Hop 0.410 33 0.135 ≤0.4 PASS 2DH3 Ant1 Hop 1.663 21 0.349 ≤0.4 PASS 2DH5 Ant1 Hop 2.911 7 0.204 ≤0.4 PASS 3DH1 Ant1 Hop 0.410 32 0.131 ≤0.4 PASS 3DH3 Ant1 Hop 1.661 17 0.283 ≤0.4 PASS 3DH5 Ant1 Hop 2.911 7 0.204 ≤0.4 PASS Notes: 1. Period time = 0.4s * 79 = 31.6s 2. Result (Time of occupancy) = BurstWidth[ms] * Hops in 3.16s [Num] * 10 Test Graphs DH1_Ant1_Hop Page 41 of 65 Report No.: MTi221025004-01E1 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] DH3_Ant1_Hop DH5_Ant1_Hop Page 42 of 65 Report No.: MTi221025004-01E1 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] 2DH1_Ant1_Hop Page 43 of 65 Report No.: MTi221025004-01E1 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] 2DH3_Ant1_Hop 2DH5_Ant1_Hop Page 44 of 65 Report No.: MTi221025004-01E1 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] 3DH1_Ant1_Hop Page 45 of 65 Report No.: MTi221025004-01E1 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] 3DH3_Ant1_Hop 3DH5_Ant1_Hop Page 46 of 65 Report No.: MTi221025004-01E1 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Page 47 of 65 Report No.: MTi221025004-01E1 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] APPENDIX E: NUMBER OF HOPPING CHANNELS Test Result Test Mode Antenna Frequency [MHz] Result [Num] Limit [Num] Verdict DH5 Ant1 Hop 79 ≥15 PASS 2DH5 Ant1 Hop 79 ≥15 PASS 3DH5 Ant1 Hop 79 ≥15 PASS Page 48 of 65 Report No.: MTi221025004-01E1 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] Test Graphs DH5_Ant1_Hop 2DH5_Ant1_Hop 3DH5_Ant1_Hop Page 49 of 65 Report No.: MTi221025004-01E1 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] APPENDIX F: BAND EDGE MEASUREMENTS Test Graphs DH5_Ant1_Low_2402 DH5_Ant1_High_2480 Page 50 of 65 Report No.: MTi221025004-01E1 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] DH5_Ant1_Low_Hop_2402 DH5_Ant1_High_Hop_2480 2DH5_Ant1_Low_2402 Page 51 of 65 Report No.: MTi221025004-01E1 Address: 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Tel: (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.com E-mail: [email protected] 2DH5_Ant1_High_2480 2DH5_Ant1_Low_Hop_2402 2DH5_Ant1_High_Hop_2480 Page 52 of 65 Report No.: MTi221025004-01E1 Address: 101, No.7, Zone 2, Xinxing Industrial …

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China Te l : (86-755)88850135 Fax: (86-755) 88850136 Web: www.mtitest.co…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jenny Qiu(Purchasing Manager)
[email protected]0755-29082307Fax: 0755-29082307

Technical Contact

Shenzhen Microtest Co., LtdLeon Chen
[email protected]86-755 88850135

Shenzhen · China

Test Firm

Shenzhen Microtest Co., Ltd.Phoebe Cui
[email protected]0755 88850135 1393

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.80 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from YI ZHAO (SHENZHEN) CO., LIMITED.

Wireless Headphones - FCC ID 2A25A-A70GEN2 - YI ZHAO (SHENZHEN) CO., LIMITED.
2A25A-A70GEN2

Wireless Headphones

Jun 18, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Wireless Gaming Headset - FCC ID 2A25A-E5000BT - YI ZHAO (SHENZHEN) CO., LIMITED.
2A25A-E5000BT

Wireless Gaming Headset

Sep 29, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
SuperEQ S10 - FCC ID 2A25A-S10 - YI ZHAO (SHENZHEN) CO., LIMITED.
2A25A-S10

SuperEQ S10

Apr 01, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
EKSA H5 - FCC ID 2A25A-H5 - YI ZHAO (SHENZHEN) CO., LIMITED.
2A25A-H5

EKSA H5

Mar 17, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2A25A-T11

OpenRock X

Jan 22, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter