FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Ekoo Electronic Co., Ltd/
  3. 2A2PN-BR600

2A2PN-BR600Portable Emergency Jump Starter

Ekoo Electronic Co., Ltd
Portable Emergency Jump Starter - FCC ID 2A2PN-BR600 - Ekoo Electronic Co., Ltd
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Mar 01, 2022
Application Purpose
Original Equipment
Date of Application
Mar 01, 2022
Equipment Note
Portable Emergency Jump Starter
Frequency Range
0.11010000 - 0.20500000
Company
Ekoo Electronic Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User Manual BUTURE BR600 Jump Starter FCC STATEMENT : This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Wireless Power Bank cannot be used as a mobile phone battery. Notes to users: Recommended to be placed on the table during charging. Language 01-09 10-17 18-27 28-37 38-44 45-53 English Deutsch Français Italiano Español Package Content BUTURE BR600 Jump StarterSmart Jumper Cables Type C CableEC5 Cigarette Lighter User ManualStorage Box EN010203040506070809 1011121314151617 18192021222324252627 28293031323334353637 38394041424344 454647484950515253 Introduction Thank you for purchasing BUTURE BR600 car jump starter. Please read the user manual carefully before you start to use the product. Key Features A Powerful Jump Starter: Car Jump Starter with 2500 amps peak current can jump starts 12V cars, SUV, truck or van (All Gas or 8.0L Diesel) in seconds up to 30 times on a single charge. Power Bank & Wireless Charger:10W wireless charger function and large 23800mAh battery capacity can provide sufficient power to quick charge your smartphones. Dual USB Charger with QC3.0 & 5V 2.4A: It can full charge your laptops, smart phones, tablets, and other devices at the fastest speed possible. Safety Protection: The high quality and spray gold clamps with a built-in protection circuit provides over-current protection, short circuit protection, over-load protection, over-voltage protection, over-charge protection. Provide ultimate protection for your safety. A Life Saver: 4 modes LED light: flashlight, strobe light, SOS signal light, and warning light, built-in safety hammer for emergency. EN010203040506070809 1011121314151617 18192021222324252627 28293031323334353637 38394041424344 454647484950515253 Jump Starting Port LED Light QC3.0 USB Output 5V/2.4A USB Output TYPE C Input Red Jumper Cable (+) Black Jumper Cable (-) Smart Clamp Plug Power Switch Battery Indicator Wireless charger Safety Hammer Know Your Product Powerful Circuit Protection System - Smart Clamps EN010203040506070809 1011121314151617 18192021222324252627 28293031323334353637 38394041424344 454647484950515253 Technical Specifications Technical Details No 1 2 3 4 5 6 7 8 9 Function ON/OFF Button Flashlight Charge indicator light USB C input Output 1 QC3.0 Output 2 USB Wireless charger Jump starting port Safety hammer Operation Press the button to charge your devices. Press the button to see the remaining capacity Long press the button to turn on/off the flashlight Normal, SOS, Strobe, Warning Light, off Shows the charging press:25%,50%,75% and 100% Charge the stater with Type c cable Charge your phone,tablet,camera,etc.75% faster than a standard charge Charge your phone,tablet,camera,etc. 5V/2.4A 12W output Charge your phone or other devices which can support wireless charger Insert the plug into the jump starting port Use in emergency or dangerous situation Model Capacity Starting Current Peak Current USB C Input Output 1 Output 2 Wireless Charger Dimensions(L*W*H) BR600 23800mAh 1200A 2500A 9V/2A, 5V/3A 9V/2A, 5V/2.4A 5V/2.4A 10W 183*95.5*42.8 EN010203040506070809 1011121314151617 18192021222324252627 28293031323334353637 38394041424344 454647484950515253 Press the power button to check the capacity of the Jump starter.Indi- cator Lights as below picture(25%,50%,75%,100%) NOTE: The wall charger or car charger is not included in the package, you can use a universal USB charger to recharge the unit, such as your phone or pad charger(2A above is suggested) At Home: 1.Plug the USB cable into any USB wall adaptor (5V 2A above, not included) 2.Connect the UCB C cableincluded to the unit In Car: 1.Plug the USB car adapter(not included)into an available 12v socket 2.Connect the USB C (included ) to the unit. Note: It is recommended to recharge the Jump starter every 3-4months to maintain the efficiency and prolong the service life of the internal battery even if the unit has not been used. Operation Power indicator light Recharge the Jump starter Overload/Discharge Fuse Working Temperature Backflow Protection Short circuit fuse protection Reverse polarity protection ≤13V±0.3V -20~60 / -4~140 ≥12.6V±0.3V √ √ EN010203040506070809 1011121314151617 18192021222324252627 28293031323334353637 38394041424344 454647484950515253 Use the original manufacturer's USB cable that came with yo…

Text truncated - open the document above for the full version.

External Photos

FCCID:2A2PN-BR600

ID Label/Location Info

LabelLocationOnEUT Label ProductName:PortableEmergencyJumpStarter ModelNo.:BR600 FCCID:2A2PN-BR600 ThisdevicecomplieswithPart15oftheFCCRules.Operationis subjecttothefollowingtwoconditions: (1)Thisdevicemaynotcauseharmfulinterference,and (2)Thisdevicemustacceptanyinterferencereceived,including interferencethatmaycauseundesiredoperation.

Internal Photos

FCCID:2A2PN-BR600 ANT

Operational Description

version01 EkooElectronicCo.,Ltd DeclarationconcerningAntennaSpecification Itisherebydeclaredthattheproduct ModelNo.:BR600,SJS1,SJS5,SJS6,SJS8,SJS9,BR300,BR400,BR500,YR800, CF500,BR900 FCCID:2A2PN-BR600 fulfillstherequirementinFCCtestrelatingtotheantennatype. ThedevicespecifiedaboveconfirmstotheFCCrecommendationsfor internal antennatype(s) describedbelow: ModelNo.ofantenna:N/A Typeofantenna:InductiveloopcoilAntenna Gainoftheantenna:0dBi Frequencyrange:110.1-205KHz Themountingoftheantennaisfixedtotheradiomoduleandnootherantennashouldbeused. Companyname:EkooElectronicCo.,Ltd Address:B09,BlockB,F2,Bldg.B,RunfengPioneerPark,No.973,MinzhiAvenue, MinzhiSt.,Longhua,Shenzhen,CHINA518000 City:Shenzhen ZIP/Postalcode:/ Country:China Place:ShenzhenDate:2/28/2022 Signature:

RF Exposure Info

ReportNo.:18220WC20021702FCCID:2A2PN-BR600Page1of13 Code:AB-RF-05-a FCCTESTREPORT ClientName:EkooElectronicCo.,Ltd Address: B09,BlockB,F2,Bldg.B,RunfengPioneerPark,No.973, MinzhiAvenue,MinzhiSt.,Longhua,Shenzhen,CHINA 518000 ProductName:PortableEmergencyJumpStarter Date:Feb.28,2022 ShenzhenAnbotekComplianceLaboratoryLimited ReportNo.:18220WC20021702FCCID:2A2PN-BR600Page2of13 Code:AB-RF-05-a Contents 1.GeneralInformation ............................................................................................................................................... 4 1.1.ClientInformation ....................................................................................................................................... 4 1.2.DescriptionofDevice(EUT) ..................................................................................................................... 4 1.3.AuxiliaryEquipmentUsedDuringTest ................................................................................................... 5 1.4.TestEquipmentList .................................................................................................................................... 5 1.5.MeasurementUncertainty ......................................................................................................................... 5 1.6.DescriptionofTestFacility ........................................................................................................................ 6 2.MeasurementandResult ..................................................................................................................................... 7 2.1.Requirements .............................................................................................................................................. 7 2.2.TestSetup .................................................................................................................................................... 8 2.3.TestProcedure ............................................................................................................................................ 8 2.4.TestResult ................................................................................................................................................... 8 APPENDIXI--TESTSETUPPHOTOGRAPH ................................................................................................... 11 ReportNo.:18220WC20021702FCCID:2A2PN-BR600Page3of13 Code:AB-RF-05-a TESTREPORT Applicant:EkooElectronicCo.,Ltd Manufacturer:EkooElectronicCo.,Ltd ProductName:PortableEmergencyJumpStarter ModelNo.: BR600,SJS1,SJS5,SJS6,SJS8,SJS9,BR300,BR400,BR500,YR800, CF500,BR900 TradeMark: BUTURE Rating(s): Type-Cinput:5V/3A,9V/2A USB1Output:5V2.4A,9V/2A USB2Output:5V/2.4A WirelessCharger:10WMax Batterycapacity:11.1V,23800mAh TestStandard(s): FCCPart1.1310,1.1307(b) TestMethod(s): KDB680106D01RFExposureWirelessChargingAppsv03 ThedevicedescribedaboveistestedbyShenzhenAnbotekComplianceLaboratoryLimitedto determinethemaximumemissionlevelsemanatingfromthedeviceandtheseverelevelsofthedevice canendureanditsperformancecriterion.Themeasurementresultsarecontainedinthistestreportand ShenzhenAnbotekComplianceLaboratoryLimitedisassumedfullofresponsibilityfortheaccuracy andcompletenessofthesemeasurements.Also,thisreportshowsthattheEUT(EquipmentUnder Test)istechnicallycompliantwiththeFCCPart1.1307&KDB680106D01requirements. Thisreportappliestoabovetestedsampleonlyandshallnotbereproducedinpartwithoutwritten approvalofShenzhenAnbotekComplianceLaboratoryLimited. DateofReceipt Feb.17,2022 DateofTest Feb.17~23,2022 PreparedBy (SherryXie) Approved&AuthorizedSigner (TomChen) ReportNo.:18220WC20021702FCCID:2A2PN-BR600Page4of13 Code:AB-RF-05-a 1.GeneralInformation 1.1.ClientInformation Applicant: EkooElectronicCo.,Ltd Address: B09,BlockB,F2,Bldg.B,RunfengPioneerPark,No.973,MinzhiAvenue, MinzhiSt.,Longhua,Shenzhen,CHINA518000 Manufacturer: EkooElectronicCo.,Ltd Address: B09,BlockB,F2,Bldg.B,RunfengPioneerPark,No.973,MinzhiAvenue, MinzhiSt.,Longhua,Shenzhen,CHINA518000 Factory:EkooElectronicCo.,Ltd Address: B09,BlockB,F2,Bldg.B,RunfengPioneerPark,No.973,MinzhiAvenue, MinzhiSt.,Longhua,Shenzhen,CHINA518000 1.2.DescriptionofDevice(EUT) ProductName:PortableEmergencyJumpStarter ModelNo.: BR600,SJS1,SJS5,SJS6,SJS8,SJS9,BR300,BR400,BR500,YR800, CF500,BR900 (Note:Allsamplesarethesameexceptthemodelnumberandcolor,sowe prepare“BR600”fortestonly.) TradeMark: BUTURE TestPowerSupply:DC11.1VBatteryinside TestSampleNo.:1-2-1(NormalSample),1-2-2(EngineeringSample) Product Description : OperationFrequency:110.1-205KHz ModulationType:FSK AntennaType:InductiveloopcoilAntenna AntennaGain(Peak):0dBi(Providedbycustomer) Adapter:N/A Remark:1)Foramoredetailedfeaturesdescription,pleaserefertothemanufacturer’sspecifications ortheUser’sManual. ReportNo.:18220WC20021702FCCID:2A2PN-BR600Page5of13 Code:AB-RF-05-a 1.3.AuxiliaryEquipmentUsedDuringTest Adapter:M/N:A2613 Input:AC100-240V,1.8A,50-60Hz Output:5V2.4A/9V3A/15V3A/20V3A Wirelesscharging load :M/N:CD2531 Power:5W/7.5W/10W/15W 1.4.TestEquipmentList ItemEquipmentManufacturerModelNo.SerialNo.LastCal.Cal.Interval 1 ElectricandMagnetic fieldAnalyzer NARDAEHP-200A180ZX10202Feb.24,20211Year 1.5.MeasurementUncertainty MagneticFieldReading(A/m): +/-0.04282(A/m) ElectricFieldReading(V/m): +/-0.03679(V/m) ReportNo.:18220WC20021702FCCID:2A2PN-BR600Page6of13 Code:AB-RF-05-a 1.6.DescriptionofTestFacility Thetestfacilityisrecognized,certified,oraccreditedbythefollowingorganizations: FCC-RegistrationNo.:184111 ShenzhenAnbotekComplianceLaboratoryLimited,EMCLaboratoryhasbeenregisteredandfully describedinareportfiledwiththe(FCC)FederalCommunicationsCommission.Theacceptanceletter fromtheFCCismaintainedinourfiles.RegistrationNo.184111. ISED-RegistrationNo.:8058A ShenzhenAnbotekComplianceLaboratoryLimited,EMCLaboratoryhasbeenregisteredandfully describedinareportfiledwiththe(ISED)Innovation,ScienceandEconomicDevelopmentCanada.The acceptanceletter…

Text truncated - open the document above for the full version.

Test Report

ReportNo.:18220WC20021701FCCID:2A2PN-BR600Page1of31 Code:AB-RF-05-a FCCTESTREPORT ClientName:EkooElectronicCo.,Ltd Address: B09,BlockB,F2,Bldg.B,RunfengPioneerPark,No.973, MinzhiAvenue,MinzhiSt.,Longhua,Shenzhen,CHINA 518000 ProductName:PortableEmergencyJumpStarter Date:Feb.28,2022 ShenzhenAnbotekComplianceLaboratoryLimited ReportNo.:18220WC20021701FCCID:2A2PN-BR600Page2of31 Code:AB-RF-05-a Contents 1.GeneralInformation ............................................................................................................................................... 4 1.1.ClientInformation ....................................................................................................................................... 4 1.2.DescriptionofDevice(EUT) ..................................................................................................................... 4 1.3.AuxiliaryEquipmentUsedDuringTest ................................................................................................... 5 1.4.DescriptionofTestModes ........................................................................................................................ 5 1.5.DescriptionOfTestSetup ......................................................................................................................... 6 1.6.TestEquipmentList .................................................................................................................................... 7 1.7.MeasurementUncertainty ......................................................................................................................... 8 1.8.DescriptionofTestFacility ........................................................................................................................ 8 2.SummaryofTestResults ..................................................................................................................................... 9 3.ConductedEmissionTest ................................................................................................................................... 10 3.1.TestStandardandLimit .......................................................................................................................... 10 3.2.TestSetup .................................................................................................................................................. 10 3.3.TestProcedure .......................................................................................................................................... 10 3.4.TestData .................................................................................................................................................... 10 4.RadiationSpuriousEmission ............................................................................................................................. 13 4.1.TestStandardandLimit .......................................................................................................................... 13 4.2.TestSetup .................................................................................................................................................. 13 4.3.TestProcedure .......................................................................................................................................... 14 4.4.TestData .................................................................................................................................................... 14 5.AntennaRequirement ......................................................................................................................................... 19 5.1.TestStandardandRequirement ............................................................................................................ 19 5.2.AntennaConnectedConstruction .......................................................................................................... 19 APPENDIXI--TESTSETUPPHOTOGRAPH ................................................................................................... 20 APPENDIXII--EXTERNALPHOTOGRAPH ..................................................................................................... 22 APPENDIXIII--INTERNALPHOTOGRAPH ..................................................................................................... 27 ReportNo.:18220WC20021701FCCID:2A2PN-BR600Page3of31 Code:AB-RF-05-a TESTREPORT Applicant:EkooElectronicCo.,Ltd Manufacturer:EkooElectronicCo.,Ltd ProductName:PortableEmergencyJumpStarter ModelNo.: BR600,SJS1,SJS5,SJS6,SJS8,SJS9,BR300,BR400,BR500,YR800, CF500,BR900 TradeMark: BUTURE Rating(s): Type-Cinput:5V/3A,9V/2A USB1Output:5V2.4A,9V/2A USB2Output:5V/2.4A WirelessCharger:10WMax Batterycapacity:11.1V,23800mAh TestStandard(s): FCCPart15SubpartC,Paragraph15.209 TestMethod(s): ANSIC63.10:2020 ThedevicedescribedaboveistestedbyShenzhenAnbotekComplianceLaboratoryLimitedto determinethemaximumemissionlevelsemanatingfromthedeviceandtheseverelevelsofthedevice canendureanditsperformancecriterion.Themeasurementresultsarecontainedinthistestreportand ShenzhenAnbotekComplianceLaboratoryLimitedisassumedfullofresponsibilityfortheaccuracy andcompletenessofthesemeasurements.Also,thisreportshowsthattheEUT(EquipmentUnder Test)istechnicallycompliantwiththeFCCPart15SubpartCrequirements. Thisreportappliestoabovetestedsampleonlyandshallnotbereproducedinpartwithoutwritten approvalofShenzhenAnbotekComplianceLaboratoryLimited. DateofReceiptFeb.17,2022 DateofTestFeb.17~23,2022 PreparedBy (SherryXie) Approved&AuthorizedSigner (TomChen) ReportNo.:18220WC20021701FCCID:2A2PN-BR600Page4of31 Code:AB-RF-05-a 1.GeneralInformation 1.1.ClientInformation Applicant:EkooElectronicCo.,Ltd Address: B09,BlockB,F2,Bldg.B,RunfengPioneerPark,No.973,MinzhiAvenue, MinzhiSt.,Longhua,Shenzhen,CHINA518000 Manufacturer: EkooElectronicCo.,Ltd Address: B09,BlockB,F2,Bldg.B,RunfengPioneerPark,No.973,MinzhiAvenue, MinzhiSt.,Longhua,Shenzh…

Text truncated - open the document above for the full version.

Test Setup Photos

FCCID:2A2PN-BR600 PhotoofConductedEmissionMeasurement PhotoofRadiationEmissionTest

Contact Information

Applicant

George. wang
[email protected]0755-83748050Fax: 0755-83748050

Test Firm

Shenzhen Anbotek Compliance Laboratory LimitedJeff Zhu
[email protected]86-755-26064492Fax: 86-755-26014772

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.1101 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from Ekoo Electronic Co., Ltd

Electric treadmill - FCC ID 2A2PN-P11PRO - Ekoo Electronic Co., Ltd
2A2PN-P11PRO

Electric treadmill

Jul 31, 2026

Equipment Class

JAB - Part 15 Class B Digital Device
Electric treadmill - FCC ID 2A2PN-HM3 - Ekoo Electronic Co., Ltd
2A2PN-HM3

Electric treadmill

Dec 02, 2024

Equipment Class

DTS - Digital Transmission System
Electric treadmill - FCC ID 2A2PN-P11 - Ekoo Electronic Co., Ltd
2A2PN-P11

Electric treadmill

Sep 17, 2024

Equipment Class

DTS - Digital Transmission System
Jump Starter - FCC ID 2A2PN-JS-1PRO - Ekoo Electronic Co., Ltd
2A2PN-JS-1PRO

Jump Starter

Jul 24, 2024

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
2.1 Soundbar System - FCC ID 2A2PN-HW-T150 - Ekoo Electronic Co., Ltd
2A2PN-HW-T150

2.1 Soundbar System

Aug 25, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter