
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
- Shen Zhen Shi Meng Zhi Tuo Ke Ji You Xian Gong Si - Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 5/4/2023 U.S. Agent Designation Shen Zhen Shi Meng Zhi Tuo Ke Ji You Xian Gong Si acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2A3W8BDB100WF-3): Contact Name: Tim Payne Company of U.S. agent: FCC US Agent, LLC Physical U.S. address of agent: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA FRN of U.S. agent: 0033402884 Email address of U.S. agent: [email protected] FCC US Agent, LLC acknowledges their obligation to accept service of process on behalf of Shen Zhen Shi Meng Zhi Tuo Ke Ji You Xian Gong Si. Shen Zhen Shi Meng Zhi Tuo Ke Ji You Xian Gong Si with the FRN 0031725823 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). Sincerely, Signature karlie hu manager Shen Zhen Shi Meng Zhi Tuo Ke Ji You Xian Gong Si Signature Tim Payne Manager FCC US Agent, LLC 48_[mo del] US_Agent_2.911(d)(7) - U, V04 The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB.
C5266091_X24_Ed.2 1/1 Shen Zhen Shi Meng Zhi Tuo Ke Ji You Xian Gong Si “Attestation Statements” TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: Shen Zhen Shi Meng Zhi Tuo Ke Ji You Xian Gong Si Grantee code: 2A3W8 FCC ID: 2A3W8BDB100WF-3 Contact Name: karlie hu Address: Qian Wan yi lu 1 hao A dong 201 shi, qian hai shen gang he zuo qu shen zhen, guang dong 518000 China Telephone No: 13719247689 Fax No: N/A Email: [email protected] i. [Shen Zhen Shi Meng Zhi Tuo Ke Ji You Xian Gong Si] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [Shen Zhen Shi Meng Zhi Tuo Ke Ji You Xian Gong Si] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. [Shen Zhen Shi Meng Zhi Tuo Ke Ji You Xian Gong Si] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List as an entity producing “covered” equipment. Date: 2023/05/05 Applicant’s Name: karlie hu Title: manager Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist
Shen Zhen Shi Meng Zhi Tuo Ke Ji You Xian Gong Si Product Similarity Declaration Product name: LED smart floodlight Model name: BDB100WF-3, BDB55WF-3 FCC ID: 2A3W8BDB100WF-3 We (Shen Zhen Shi Meng Zhi Tuo Ke Ji You Xian Gong Si) hereby state that all the models are electrical identical including the same software parameter and hardware design (i.e., circuit design, PCB Layout, RF module/circuit, antenna type(s) and antenna location, components on PCB, etc.,), same mechanical structure and design (including product enclosure, materials, etc.,), the only difference is the model name, LED lamp Rated Power and Luminous Flux has slight differences. Signature: Client’s name / title : karlie hu / Manager Contact information / address : Qian Wan yi lu 1 hao A dong 201 shi, qian hai shen gang he zuo qu shen zhen, guang dong, 518000 China Tel: 13719247689Fax: N/A E-Mail: [email protected]
C5266091_X8_Ed.1 1/1 Shen Zhen Shi Meng Zhi Tuo Ke Ji You Xian Gong Si Letter of Authorization Company: Shen Zhen Shi Meng Zhi Tuo Ke Ji You Xian Gong Si Address: Qian Wan yi lu 1 hao A dong 201 shi, qian hai shen gang he zuo qu shen zhen, guang dong 518000 China Product Name: LED smart floodlight Model Number: BDB100WF-3, BDB55WF-3 FCC Identifier: 2A3W8BDB100WF-3 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: karlie hu Date: 2023.05.05 Title: manager Signature of applicant:
C5266091_X10_Ed.2 1/1 Shen Zhen Shi Meng Zhi Tuo Ke Ji You Xian Gong Si Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2023-05.05 Subject: LED smart floodlight FCC ID: 2A3W8BDB100WF-3 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☒ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name: karlie hu Title: manager 2023.05.05
Page 1 of 3 FCC ID: 2A3W8BDB100WF-3 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 3 FCC ID: 2A3W8BDB100WF-3 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 3 FCC ID: 2A3W8BDB100WF-3 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6
Page 1 of 1 FCC ID: 2A3W8BDB100WF-3 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L 3.0cm x W 1.5cm) Label Location LED smart floodlight Model: BDB100WF-3 FCC ID: 2A3W8BDB100WF-3 WM-1BH YY
Page 1 of 6 FCC ID: 2A3W8BDB100WF-3 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 6 FCC ID: 2A3W8BDB100WF-3 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 6 FCC ID: 2A3W8BDB100WF-3 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 WiFi Antenna Page 4 of 6 FCC ID: 2A3W8BDB100WF-3 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 6 FCC ID: 2A3W8BDB100WF-3 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10 Page 6 of 6 FCC ID: 2A3W8BDB100WF-3 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 11 Fig. 12
Page 1 of 4 FCC ID: 2A3W8BDB100WF-3 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC RF Exposure Evaluation 1. Product Information Product name LED smart floodlight Test Model BDB100WF-3 Additional Model No. BDB55WF-3 Model Declaration PCB board, structure and internal of these model(s) are the same, So no additional models were tested Power Supply Input: AC 100-120V, 0.83A, 60Hz, 100W Hardware Version / Software Version / Frequency Range 2412MHz ~ 2462MHz Channel Number 11 Channels for 20MHz bandwidth (2412~2462MHz) Channel Spacing 5MHz Modulation Type IEEE 802.11b: DSSS (CCK, DQPSK, DBPSK) IEEE 802.11g: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11n: OFDM (64QAM, 16QAM, QPSK, BPSK) Antenna Description PCB Antenna, 3.0dBi(max.) Exposure category General population/uncontrolled environment EUT Type Production Unit Device Type Mobile Devices 2. Evaluation Method Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device whereby a distance of 0.2m normally can be maintained between the user and the device, and below RF Permissible Exposure limit shall comply with. In accordance with KDB447498D01 for Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the calculated/estimated, numerically modelled or measured field strengths or power density, is ≤ 1.0. The MPE ratio of each antenna is determined at the minimum test separation distance required by the operating configurations and exposure conditions of the host device, according to the ratio of field strengths or power density to MPE limit, at the test frequency. Either the maximum peak or spatially averaged results from measurements or numerical simulations may be used to determine the MPE ratios. Spatial averaging does not apply when MPE is estimated using simple calculations based on far-field plane-wave equivalent conditions. The antenna installation and operating requirements for the host device must meet the minimum test separation distances required by all antennas, in both standalone and simultaneous transmission operations, to satisfy compliance. Page 2 of 4 FCC ID: 2A3W8BDB100WF-3 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 3. Limit 3. 1 Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General 1 RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices 3. 2 Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100) * (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100) * (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequency in MHz *=Plane-wave equivalent power density 4. MPE Calculation Method Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna 5. Antenna Information PCB Antenna can only use antennas certificated as follows provided by manufacturer; Internal Identification Antenna type and antenna number Operate frequency band Maximum antenna gain Note Antenna PCB Antenna 2412MHz-2462MHz 3.0dBi WIFI Antenna Page 3 of 4 FCC ID: 2A3W8BDB100WF-3 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 6. Conducted Power <2.4G WIFI> Mode Channel Frequency(MHz) Max Conducted Power (dBm) IEEE 802.11b 1 2412 12.64 6 2437 12.62 11 2462 12.30 IEEE 802.11g 1 2412 13.56 6 2437 13.55 11 2462 12.02 IEEE 802.11n HT20 1 2412 12.69 6 2437 12.66 11 2462 13.17 7. Manufacturing Tolerance <2.4G WIFI> 11B (Peak) Channel Channel 1 Channel 6 Channel 11 Target (dBm) 12.0 12.0 12.0 Tolerance ±(dB) 1.0 1.0 1.0 11G (Peak) Channel Channel 1 Channel 6 Channel 11 Target (dBm) 13.0 13.0 12.0 Tolerance ±(dB) 1.0 1.0 1.0 11N20SISO (Peak) Channel Channel 1 Channel 6 Channel 11 Target (dBm) 12.0 12.0 13.0 Tolerance ±(dB) 1.0 1.0 1.0 Page 4 of 4 FCC ID: 2A3W8BDB100WF-3 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, …
Text truncated - open the document above for the full version.
QR/RD-P01-09B SPECIFICATION ShenzhenGuandetongElectronicLimited Antennatestreport http://www.szgdtrf.com Page2 Content cover .................................................................................................... 1 catalogue .............................................................................................. 2 一、Productpictures ......................................................................... 3 二、Productparameters ......................................................................... 3 三、S11data ................................................................................................................... 4 四、AntennaDimension ........................................................................... 5 五、 RadiationPattern ................................................................. 6 http://www.szgdtrf.com Page3 一、Productpictures 二、Product parameters Product parameters Name FPC Antenna Model Type GDT-2PWIFI-001 Electrical Specifications Frenquency Range 2400-2500MHz Polarizationperpendicular Impedance 50 Ω Radiation directionomnidirectional VSWR ≦2Power 50W Gain 3.00dBi Bandwidth 100/600MHz Mechanical Specifications Dimensions41.40*12±1mm Chassis Color black ConnectorIPEX Cable Length 60MM FPC Chassis Material Working Temperature -40°C-+85°C Limit Temperature -40°C-+85°C http://www.szgdtrf.com Page4 三、S11(VSWR、Returnloss、Smith) http://www.szgdtrf.com Page5 四、AntennaDimension http://www.szgdtrf.com Page6 五、RadiationPattern http://www.szgdtrf.com Page7
Page 1 of 44 FCC ID: 2A3W8BDB100WF-3 Report No.: LCSA032023207EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A RF Test Data for 2.4G WIFI (Conducted Measurement) Product Name: LED smart floodlight Test Model: BDB100WF-3 Environmental Conditions Temperature: 23.8 C Relative Humidity: 52.1% ATM Pressure: 100.0 kPa Test Engineer: Mening Su Supervised by: Ling Zhu Page 2 of 44 FCC ID: 2A3W8BDB100WF-3 Report No.: LCSA032023207EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.1 -6dB Bandwidth Condition Mode Frequency (MHz) Antenna -6 dB Bandwidth (MHz) Limit -6 dB Bandwidth (MHz) Verdict NVNT b 2412 Ant1 8.642 0.5 Pass NVNT b 2437 Ant1 9.516 0.5 Pass NVNT b 2462 Ant1 8.503 0.5 Pass NVNT g 2412 Ant1 15.913 0.5 Pass NVNT g 2437 Ant1 15.747 0.5 Pass NVNT g 2462 Ant1 15.106 0.5 Pass NVNT n20 2412 Ant1 17.558 0.5 Pass NVNT n20 2437 Ant1 17.551 0.5 Pass NVNT n20 2462 Ant1 13.688 0.5 Pass Page 3 of 44 FCC ID: 2A3W8BDB100WF-3 Report No.: LCSA032023207EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -6dB Bandwidth NVNT b 2412MHz Ant1 -6dB Bandwidth NVNT b 2437MHz Ant1 Page 4 of 44 FCC ID: 2A3W8BDB100WF-3 Report No.: LCSA032023207EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT b 2462MHz Ant1 -6dB Bandwidth NVNT g 2412MHz Ant1 Page 5 of 44 FCC ID: 2A3W8BDB100WF-3 Report No.: LCSA032023207EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT g 2437MHz Ant1 -6dB Bandwidth NVNT g 2462MHz Ant1 Page 6 of 44 FCC ID: 2A3W8BDB100WF-3 Report No.: LCSA032023207EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT n20 2412MHz Ant1 -6dB Bandwidth NVNT n20 2437MHz Ant1 Page 7 of 44 FCC ID: 2A3W8BDB100WF-3 Report No.: LCSA032023207EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT n20 2462MHz Ant1 Page 8 of 44 FCC ID: 2A3W8BDB100WF-3 Report No.: LCSA032023207EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.2 Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Total Power (dBm) Limit (dBm) Verdict NVNT b 2412 Ant1 12.64 30 Pass NVNT b 2437 Ant1 12.62 30 Pass NVNT b 2462 Ant1 12.30 30 Pass NVNT g 2412 Ant1 13.56 30 Pass NVNT g 2437 Ant1 13.55 30 Pass NVNT g 2462 Ant1 12.02 30 Pass NVNT n20 2412 Ant1 12.69 30 Pass NVNT n20 2437 Ant1 12.66 30 Pass NVNT n20 2462 Ant1 13.17 30 Pass Page 9 of 44 FCC ID: 2A3W8BDB100WF-3 Report No.: LCSA032023207EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.3 Maximum Power Spectral Density Level Condition Mode Frequency (MHz) Antenna Total PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNT b 2412 Ant1 -12.3 8 Pass NVNT b 2437 Ant1 -12.02 8 Pass NVNT b 2462 Ant1 -11.6 8 Pass NVNT g 2412 Ant1 -14.75 8 Pass NVNT g 2437 Ant1 -13.19 8 Pass NVNT g 2462 Ant1 -15.04 8 Pass NVNT n20 2412 Ant1 -15.33 8 Pass NVNT n20 2437 Ant1 -14.44 8 Pass NVNT n20 2462 Ant1 -15.19 8 Pass Page 10 of 44 FCC ID: 2A3W8BDB100WF-3 Report No.: LCSA032023207EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs PSD NVNT b 2412MHz Ant1 PSD NVNT b 2437MHz Ant1 Page 11 of 44 FCC ID: 2A3W8BDB100WF-3 Report No.: LCSA032023207EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity PSD NVNT b 2462MHz Ant1 PSD NVNT g 2412MHz Ant1 Page 12 of 44 FCC ID: 2A3W8BDB100WF-3 Report No.: LCSA032023207EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial P…
Text truncated - open the document above for the full version.
Page1of36FCCID:2A3W8BDB100WF-3ReportNo.:LCSA032023207EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT For ShenZhenShiMengZhiTuoKeJiYouXianGongSi LEDsmartfloodlight TestModel:BDB100WF-3 AdditionalModelNo.:BDB55WF-3 Preparedfor:ShenZhenShiMengZhiTuoKeJiYouXianGongSi Address:QianWanyilu1haoAdong201shi,qianhaishenganghezuoqu shenzhen,guangdong,518000China Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:April12,2023 Numberoftestedsamples:2 Samplenumber:A032023207-1,A032023207-2 Serialnumber:Prototype DateofTest:April12,2023~April27,2023 DateofReport:April27,2023 Page2of36FCCID:2A3W8BDB100WF-3ReportNo.:LCSA032023207EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C(15.247) ReportReferenceNo......................:LCSA032023207EA DateofIssue.......................................:April27,2023 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China TestingLocation/Procedure............:FullapplicationofHarmonisedstandards■ PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................:ShenZhenShiMengZhiTuoKeJiYouXianGongSi Address................................................:QianWanyilu1haoAdong201shi,qianhaishenganghezuoqu shenzhen,guangdong,518000China TestSpecification Standard..............................................: FCCCFR47PART15C(15.247) TestReportFormNo......................:LCSEMC-1.0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. EUTDescription...............................:LEDsmartfloodlight TradeMark..........................................:Onforu TestModel...........................................:BDB100WF-3 Ratings.................................................:Input:AC100-120V,0.83A,60Hz,100W Result..................................................:Positive Compiledby:Supervisedby:Approvedby: KevinHuang/AdministratorCaryLuo/TechniqueprincipalGavinLiang/Manager Page3of36FCCID:2A3W8BDB100WF-3ReportNo.:LCSA032023207EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCC--TESTREPORT EUT.........................................:LEDsmartfloodlight TestModel...............................:BDB100WF-3 Applicant...............................:ShenZhenShiMengZhiTuoKeJiYouXianGongSi Address..................................:QianWanyilu1haoAdong201shi,qianhaishenganghezuoqu shenzhen,guangdong,518000China Telephone...............................:/ Fax..........................................:/ Manufacturer........................:ShenZhenShiMengZhiTuoKeJiYouXianGongSi Address...................................:QianWanyilu1haoAdong201shi,qianhaishenganghezuoqu shenzhen,guangdong,518000China Telephone...............................: / Fax..........................................: / Factory...................................:ShenZhenShiMengZhiTuoKeJiYouXianGongSi Address...................................:QianWanyilu1haoAdong201shi,qianhaishenganghezuoqu shenzhen,guangdong,518000China Telephone...............................:/ Fax..........................................:/ TestResultPositive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetes…
Text truncated - open the document above for the full version.
Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 22.70 mW |

Floodlight Camera
Equipment Class
DTS - Digital Transmission System
Bluetooth LED Floodlight
Equipment Class
DTS - Digital Transmission System
Bluetooth LED Floodlight
Equipment Class
DTS - Digital Transmission System
LED smart floodlight
Equipment Class
DTS - Digital Transmission System
Floodlight Camera
Equipment Class
DTS - Digital Transmission System