FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Baseus Technology Co., Ltd./
  3. 2A482-PPCXM06A1

2A482-PPCXM06A1Power Bank

Shenzhen Baseus Technology Co., Ltd.
Power Bank - FCC ID 2A482-PPCXM06A1 - Shenzhen Baseus Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Apr 07, 2024
Application Purpose
Original Equipment
Date of Application
Apr 07, 2024
Equipment Note
Power Bank
Frequency Range
0.11500000 - 0.20500000
Company
Shenzhen Baseus Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗
↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Shenzhen Baseus Technology Co., Ltd. 2.911 (d)(5)(i) Equipment Type Attestation v1.2 Section 2.911(d)(5)(i) Certification – Equipment Type Company name: Shenzhen Baseus Technology Co., Ltd. Address: 2nd Floor, Building B, Baseus Intelligence Park, No.2008, Xuegang Rd, Gangtou Community, Bantian Street, Longgang District, Shenzhen, China Product Name: Power Bank FCC ID: 2A482-PPCXM06A1 Model(s): PPCXM06A 2.911(d)(5)(i) Equipment Type We, [Shenzhen Baseus Technology Co., Ltd.] (“the applicant”) certify that the equipment for which authorization is sought through certification is not:  Prohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules.  Identified as an equipment type in the “Covered List” NOTE 1 Yours sincerely, Name: Tiffany Luo Date: 2024/1/23 Title and Company name: Certified Engineer / Shenzhen Baseus Technology Co., Ltd. NOTE 1 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Attestation Statements

Shenzhen Baseus Technology Co., Ltd. 2.911 (d)(5)(ii) Applicant Attestation v1.2 Section 2.911(d)(5)(ii) Certification – Applicant (Covered List ) Company name: Shenzhen Baseus Technology Co., Ltd. Address: 2nd Floor, Building B, Baseus Intelligence Park, No.2008, Xuegang Rd, Gangtou Community, Bantian Street, Longgang District, Shenzhen, China Product Name: Power Bank FCC ID: 2A482-PPCXM06A1 Model(s): PPCXM06A 2.911(d)(5)(ii) Applicant filing We, [Shenzhen Baseus Technology Co., Ltd.] (“the applicant”) certify that, as of the date of the filing of the application, the applicant is not identified NOTE 1 on the “Covered List” NOTE 2 , established pursuant to § 1.50002 of this chapter, as an entity producing covered communications equipment. Yours sincerely, Name: Tiffany Luo Date: 2024/1/23 Title and Company name: Certified Engineer / Shenzhen Baseus Technology Co., Ltd. NOTE 1 Delete option not applicable to this application. NOTE 2 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Attestation Statements

Attestation Statements (2024/1/23) TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA RE: Attestation Statements Part 2.911(d)(7) request for (FCC ID: 2A482-PPCXM06A1) (Shenzhen Baseus Technology Co., Ltd.), the undersigned, hereby authorize Oasis Compliance, Inc. to act as our designated U.S. agent for service of process, (Shenzhen Baseus Technology Co., Ltd.) accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Oasis Compliance, Inc. accepts the responsibility to act as designated U.S. agent for service of process. Applicant Information: Company Name: Shenzhen Baseus Technology Co., Ltd. Address: 2nd Floor, Building B, Baseus Intelligence Park, No.2008, Xuegang Rd, Gangtou Community, Bantian Street, Longgang District, Shenzhen, China Contact Name: Tiffany Luo FRN: 0032035966 Telephone No: +86-13480668369 Email: [email protected] Signature [Tiffany Luo] U.S. Agent Information: Company Name: Oasis Compliance, Inc. Address: 3313 Verdi Dr, San Jose, CA 95111, United States FRN: 0033464157 Contact Name: James He Telephone No: (202) 602-8330 Email: [email protected] Signature [James He]

Cover Letter(s)

Shenzhen Baseus Technology Co., Ltd. Agent Authorization Company: Shenzhen Baseus Technology Co., Ltd. Address: 2nd Floor, Building B, Baseus Intelligence Park, No.2008, Xuegang Rd, Gangtou Community, Bantian Street, Longgang District, Shenzhen, China Product Name: Power Bank Model Number(s): PPCXM06A We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Name: Tiffany Luo Date: 2024/1/23 Title: Certified Engineer Signature of applicant:

Cover Letter(s)

Shenzhen Baseus Technology Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2024/1/23 Subject; Request for Confidentiality FCC ID: 2A482-PPCXM06A1 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Tiffany Luo Title: Certified Engineer

Cover Letter(s)

Search|RSS |Updates |E-Filing |Initiatives |Consumers |Find People Office of Engineering and Technology FCC > FCC E-filing > Inquiry System Home Page > View InquiryFCC Site Map OET Home Page Site Options Basic KDB Search Advanced KDB Search Submit an Inquiry Reply to an Inquiry Response Category List FAQ Search Major Guidance Publications Draft Laboratory Division Publications Draft Laboratory Division Publications (Expired) Draft Publication Moderation Policy Related Sites Equipment Authorization Presentations Equipment Authorization System (EAS) Telecommunications Certification Bodies (TCB) Measurement Procedures Reply to an OET Inquiry Response Currently Displaying Inquiry Tracking Number: 871298 Contact Information: Customer First Name:Willem Customer Last Name:Wang Telephone Number: 18317957743 Extension: E-mail Address: [email protected] Address: Line 1: Line 2: P.O. Box: City: State: Zip Code: Country: Inquiry Details on 03/12/2024: First category: Equipment Compliance Review Second category: Wireless Power Transfe Third category: Subject:Seeking guidance for portable wireless chargers Inquiry:Dear officer, Nice day. We have a wireless charger which is subjected to part 15. The product can work as a portable, we have been tested according to the KDB 680106 D01 Wireless Power Transfer v04 standard, The device is power Bank; The device operate in the frequency range from 115-205kHz The maximum output power of the primary coil is 15W. Client device is placed directly in contact with the transmitter. The product can work as a portable, Wireless charging coil diameter distance is 41.5mm; Here's how we measure it? Mobile Mode : The H-field intensity was measured at 15cm around EUT and 20cm above the top surface of EUT Portable Mode : Since the diameter of our probe is 3.3cm, we can not directly measure 0cm, so we measured the field intensity at a distance of 2-20CM? in 2 cm maximum increment measured from the edge of the device?In the end?Using Biot-Savart Law, the value of 0cm can be estimated through the test results of 2cm? The attachment is<MPE test Report>< External Photos>< Internal Photos>< User Manual>< Antenna Spec> Please help me check whether MPE Report can accept? Waiting for your information. Thanks for your help in advance. Best Regards! FCC Response on 03/27/2024: Dear Inquirer, it looks like you are going in the right direction, but we still have a few questions. Is your product going to be authorized under Part 15? If so, the general procedures as for any product under Part 15 needs to be followed (regardless of whether it is a WPT or not). In this case, since the device operating frequency is below 4 MHz, the RF exposure compliance can be demonstrated via MPE testing, as discussed in the last TCB workshop as well as in KDB 680106, Section 3.2. If it is a Part 18 device, then the full KDB 680106 guidance does apply. The battery status is here reported as 99%: does that mean 99% charged or 99% discharged? We need to see testing when the battery is almost discharged, or the worst case scenario that corresponds to the largest current. In regard to the check for the estimated value via Biot-Savart law, the validation needs to be done according to the procedure is outlined in KDB 680106 Section 3.3. This just requires showing that the model used to estimate the field provides data within 30% accuracy for at least the two closest points to where the estimates were made. For instance, if the probe radius is R and the probe tip is in contact with the coil, the probe center is R cm from the coil surface. The probe then is measuring the field correctly at R cm from the surface, and only estimating the field at the surface. Let's assume that R=1 cm. Then the field at 0 cm can only be estimated, but the field at 1 cm is measured exactly (at the center of the probe). Then one moves the probe at 2 cm. The field at 1 cm can be estimated, and the result compared with the actual measurement at 1 cm. The difference needs to be no less than 30%. Then one shall measure one more point. Since the field at 2 cm was also measured exactly in the center of the probe, the probe can be moved to 3 cm; the field at 2 cm (on the probe tip) can then also be estimated; the agreement, again, shall be within 30%. This completes the validation. If your probe radius is different from 1 cm, then the procedure in the example needs to be corrected accordingly. Best regards, OET Staff ---Reply from Customer on 03/29/2024--- Dear officer, Nice day. 1. The product will apply for authorizationin accordance with PART15 2. The battery status is here reported as99%?This is 99% discharge?The writing of the report has been updated? 3. About verifying Biot-Savart LAWestimates, At the basis of the comparison between the 2cm test value and the2cm estimate value; Added comparison of 4cm test values and 4cm estimates; Thedifference values both meet the 30% limit?The estimation modelis verified? Finally, the test data of 2cm is used toestimate the result of 0cm Please help me to check again whether theMPE Report is acceptable. Waiting for your information. Thanks for your help in advance. Best Regards! ---Reply from Customer on 03/29/2024--- Dear officer, Nice day. 1. The product will apply for authorizationin accordance with PART15 2. The battery status is here reported as99%?This is 99% discharge?The writing of the report has been updated? 3. About verifying Biot-Savart LAWestimates, At the basis of the comparison between the 2cm test value and the2cm estimate value; Added comparison of 4cm test values and 4cm estimates; Thedifference values both meet the 30% limit?The estimation modelis verified? Finally, the test data of 2cm is used toestimate the result of 0cm Please help me to check again whether theMPE Report is acceptable. Waiting for your information. Thanks for your help in advance. Best Regards! FCC Response on 03/29/2024: Dear Inquirer, the information provided in this ECR for this particular WPT devic…

Text truncated - open the document above for the full version.

External Photos

External Photos

Internal Photos

Internal Photos Antenna

RF Exposure Info

No.:BCTC/RF-EMC-005 Page 1 of 15 Edition:B.1 TEST REPORT Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC2401501681-2E Applicant: Shenzhen Baseus Technology Co., Ltd. Product Name: Power Bank Test Model: PPCXM06A Tested Date: 2024-01-18 to 2024-03-05 Issued Date: 2024-03-05 Report No.: BCTC2401501681-2E No.:BCTC/RF-EMC-005 Page 2 of 15 Edition:B.1 FCC ID: 2A482-PPCXM06A1 The test report is effective only with both signature and specialized stamp.This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen BCTC Testing Co., Ltd, this report can’t be reproduced except in full.The tested sample(s) and the sample information are provided by the client. Product Name: Power Bank Trademark: baseus Model/Type Reference: PPCXM06A Prepared For: Shenzhen Baseus Technology Co., Ltd. Address: 2nd Floor, Building B, Baseus Intelligence Park, No.2008, Xuegang Rd, Gangtou Community, Bantian Street, Longgang District, Shenzhen, China Manufacturer: Shenzhen Baseus Technology Co., Ltd. Address: 2nd Floor, Building B, Baseus Intelligence Park, No.2008, Xuegang Rd, Gangtou Community, Bantian Street, Longgang District, Shenzhen, China Prepared By: Shenzhen BCTC Testing Co., Ltd. Address: 1-2/F., Building B, Pengzhou Industrial Park, No.158, Fuyuan 1st Road, Zhancheng, Fuhai Subdistrict, Bao'an District, Shenzhen, Guangdong, China. Sample Received Date: 2024-01-18 Sample Tested Date: 2024-01-18 to 2024-03-05 Issue Date: 2024-03-05 Report No.: BCTC2401501681-2E Test Standards: FCC CFR 47 part1, 1.1307(b), 1.1310 KDB 680106 D01 Wireless Power Transfer v04 Test Results: PASS Tested by: Approved by: Shanshan. Zhang / Project Handler Zero Zhou/Reviewer Report No.: BCTC2401501681-2E No.:BCTC/RF-EMC-005 Page 3 of 15 Edition:B.1 Table Of Content Test Report Declaration Page 1. Version .................................................................................................................. 4 2. Product Information ............................................................................................... 5 2.1 Product Information ............................................................................................... 5 2.2 Support Equipment ............................................................................................... 5 2.3 Test Mode ............................................................................................................. 5 3. Test Facility And Test Instrument Used ................................................................. 6 3.1 Test Facility ........................................................................................................... 6 3.2 Test Instrument Used ............................................................................................ 6 4. Method Of Measurement ....................................................................................... 7 4.1 Applicable Standard .............................................................................................. 7 4.2 Block Diagram Of Test Setup ................................................................................ 7 4.3 Limit ...................................................................................................................... 8 4.4 Test procedure ...................................................................................................... 8 4.5 Equipment Approval Considerations ..................................................................... 9 4.6 E and H field Strength ......................................................................................... 10 5. Photographs Of Test Set-Up ............................................................................... 14 (Note: N/A Means Not Applicable) Report No.: BCTC2401501681-2E No.:BCTC/RF-EMC-005 Page 4 of 15 Edition:B.1 1. Version Report No. Issue Date Description Approved BCTC2401501681-2E 2024-03-05 Original Valid Report No.: BCTC2401501681-2E No.:BCTC/RF-EMC-005 Page 5 of 15 Edition:B.1 2. Product Information 2.1 Product Information Model/Type Reference: PPCXM06A Model Differences: N/A Hardware Version: N/A Software Version: N/A Operation Frequency: 115kHz-205kHz Antenna installation: coil antenna Ratings: Type C Input: DC 5V/3A or DC 9V/2A Battery: DC 3.7V 2.2 Support Equipment No. Device Type Brand Model Series No. Note E-1 Power Bank N/A PPCXM06A N/A EUT E-2 ADAPTER Hoco. N18 N/A Auxiliary E-3 Dummy load N/A DL01 N/A Auxiliary Notes: 1. All the equipment/cables were placed in the worst-case configuration to maximize the emission during the test. 2. Grounding was established in accordance with the manufacturer’s requirements and conditions for the intended use. 2.3 Test Mode AC Mode Mode 1 Wireless Charging (Full load) Mode 2 Wireless Charging (Half load) Mode 3 Wireless Charging (Null load) DC Mode Mode 4 Wireless Charging (Full load) Mode 5 Wireless Charging (Half load) Mode 6 Wireless Charging (Null load) Note: All test mode were tested and passed, only shows the worst case mode which were recorded in this report. Report No.: BCTC2401501681-2E No.:BCTC/RF-EMC-005 Page 6 of 15 Edition:B.1 3. Test Facility And Test Instrument Used 3.1 Test Facility All measurement facilities used to collect the measurement data are located at Shenzhen BCTC Testing Co., Ltd. Address:1-2/F., Building B, Pengzhou Industrial Park, No.158, Fuyuan 1st Road, Zhancheng, Fuhai Subdistrict, Bao'an District, Shenzhen, Guangdong, China. The site and apparatus are constructed in conformance with the requirements of ANSI C63.4 and CISPR 16-1-1 other equivalent standards. FCC Test Firm Registration Number: 712850 A2LA certificate registration number is: CN1212 ISED Registered No.: 23583 ISED CAB identifier: CN0017 3.2 Test Instrument Used EMF Test Equipment Manufacturer Model# Serial# Last Cal. Next Cal. Electromagnet -ic radiation tester Wavecontrol SMP160 19SN0980 May 15, 2023 May 14, 2024 Electromagnet -ic field probe Wavecontrol WP400-3 20WP12008…

Text truncated - open the document above for the full version.

Test Report

深圳市深联宇电子有限公司 Shenzhen Shenlian Yu Electronics Co., LTD 产品规格承认书 客户名称: CUSTOMER 客户品名: Product Name ofCustomer 我方产品名(材质): Product Mame ofOurs(Ma tenial) A11双槽43*0.5MM正面贴黑膜出线43MM背胶 承 认: APPROVED 核准: 制表: 日期: APPROVED邓湘 DRAWN 赖伟DATE 2024.1.16 地址:深圳市宝安区松岗溪头社区工业1路3号 电话:15112322462 传真:0755-29909524 乔威 XM06A 变更记录 REVISED RECORD PEVISON NO 版次 DATE 日期 REVISE DESCRIPTION 变更内容描述 Change person 变更人 REV:01 REV:02 ESCRINED 拟制 CHECKED 审核 APPROVED 批准 PACE 页 码 赖伟 邓湘 陈展良 * Dimension without tolerance is approx. 3. Coils Specification 3-1. Connection (Bottom View) “●”START Note: * Dimension without tolerance is approx. 1. Connection (Bottom View) Spec. No.Spec. No. Specifcation 规 格 内 容 CUSTOMERP/N: 客户名称 PARTNUMBER: 制造商料号 5.WINDING DETAILS(绕线详细说明): 6.ELECTRICAL CHARACTERISTICS(电气特性): PARAMETERS UNIN LIMTI Inductance ls@100KHz/1v uh ±5% Q @100KHz/1v 55-90 DCR @100KHz/1v mΩ 60MAX Wdy.NO. 绕 组 Start 开始 Finish 结束 Turns 圈数 Wire Dia 线径 Wdg.TyepeSprad/lose 绕线方法疏/密绕 Wdg.Direction 绕线方向 Turns/Layer 层数/每层圈数 S F 11TS 0.08*72P 漆包线 单层密绕 逆时针 1层/11TS APPROVED BY 承 认 CHECKED BY 审 查 PREPARED BY 制 作 DATE 日期 PAGE 页码 赖伟 2023.1.16 6.8 MATERIAL LIST 材 料 清 单 CUSTOMER P/N: 客 户 品 名 PARTNUMBER: 制造商料号 NO. Material name 材料名称 Description 品名描述 Manufacturer 制造商 Material 材质 1 丝包线 0.08*72P 2 无铅锡条 高温 3 磁片 43*0.5 4 高温胶带 8mm APPROVED BY 承 认 CHECKED BY 审 查 PREPARED BY 制作 DATE 日期 PAGE 页码 赖伟 2024.1.16 5 黑膜 40*0.03mm

Test Report

No.:BCTC/RF-EMC-005 Page 1 of 29 Edition:B.1 TEST REPORT Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC2401501681-1E Applicant: Shenzhen Baseus Technology Co., Ltd. Product Name: Power Bank Test Model: PPCXM06A Tested Date: 2024-01-18 to 2024-01-24 Issued Date: 2024-01-25 Report No.: BCTC2401501681-1E No.:BCTC/RF-EMC-005 Page 2 of 29 Edition:B.1 FCC ID: 2A482-PPCXM06A1 The test report is effective only with both signature and specialized stamp.This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen BCTC Testing Co., Ltd, this report can’t be reproduced except in full.The tested sample(s) and the sample information are provided by the client. Product Name: Power Bank Trademark: baseus Model/Type Reference: PPCXM06A Prepared For: Shenzhen Baseus Technology Co., Ltd. Address: 2nd Floor, Building B, Baseus Intelligence Park, No.2008, Xuegang Rd, Gangtou Community, Bantian Street, Longgang District, Shenzhen, China Manufacturer: Shenzhen Baseus Technology Co., Ltd. Address: 2nd Floor, Building B, Baseus Intelligence Park, No.2008, Xuegang Rd, Gangtou Community, Bantian Street, Longgang District, Shenzhen, China Prepared By: Shenzhen BCTC Testing Co., Ltd. Address: 1-2/F., Building B, Pengzhou Industrial Park, No.158, Fuyuan 1st Road, Zhancheng, Fuhai Subdistrict, Bao'an District, Shenzhen, Guangdong, China. Sample Received Date: 2024-01-18 Sample Tested Date: 2024-01-18 to 2024-01-24 Issue Date: 2024-01-25 Report No.: BCTC2401501681-1E Test Standards: FCC Part15.209 ANSI C63.10-2013 Test Results: PASS Tested by: Approved by: Shanshan. Zhang / Project Handler Zero Zhou/Reviewer Report No.: BCTC2401501681-1E No.:BCTC/RF-EMC-005 Page 3 of 29 Edition:B.1 Table Of Content Test Report Declaration Page 1. Version .................................................................................................................. 4 2. Test Summary ....................................................................................................... 5 3. Measurement Uncertainty ..................................................................................... 6 4. Product Information And Test Setup ..................................................................... 7 4.1 Product Information ............................................................................................... 7 4.2 Support Equipment ............................................................................................... 7 4.3 Test Setup Configuration ...................................................................................... 8 4.4 Test Mode ............................................................................................................. 9 5. Test Facility And Test Instrument Used ............................................................... 10 5.1 Test Facility ......................................................................................................... 10 5.2 Test Instrument Used .......................................................................................... 10 6. Conducted Emissions .......................................................................................... 12 6.1 Block Diagram Of Test Setup .............................................................................. 12 6.2 Limit .................................................................................................................... 12 6.3 Test procedure .................................................................................................... 12 6.4 EUT operating Conditions ................................................................................... 12 6.5 Test Result .......................................................................................................... 13 7. Radiated Emissions ............................................................................................. 15 7.1 Block Diagram Of Test Setup .............................................................................. 15 7.2 Limit .................................................................................................................... 16 7.3 Test procedure .................................................................................................... 16 7.4 Test Result .......................................................................................................... 17 8. Bandwidth Test .................................................................................................... 23 8.1 Test Procedure ................................................................................................... 23 8.2 Test Setup ........................................................................................................... 23 8.3 Test Result .......................................................................................................... 23 9. Antenna Requirements ........................................................................................ 24 9.1 Limit .................................................................................................................... 24 9.2 Test Result .......................................................................................................... 24 10. EUT Photographs ................................................................................................ 25 11. EUT Test Setup Photographs.............................................................................. 26 (Note: N/A Means Not Applicable) Report No.: BCTC2401501681-1E No.:BCTC/RF-EMC-005 Page 4 of 29 Edition:B.1 1. Version Report No. Issue Date Description Approved BCTC2401501681-1E 2024-01-25 Original Valid Report No.: BCTC2401501681-1E No.:BCTC/RF-EMC-005 Page 5 of 29 Edition:B.1 2. Test Summary The Product has been tested according to the following specifications: No. Test Parameter Clause No. Results 1 Conducted Emission 15.207 PASS 2 Radiated Emission 15.209 PASS …

Text truncated - open the document above for the full version.

Test Setup Photos

Conducted emissions Radiated Measurement Photos 30MHz-1GHz Mode 1-3 Mode 4-6 9kHz-30MHz Mode 1-3 Mode 4-6

Contact Information

Applicant

Tiffany Luo(Certified Engineer)
[email protected]+86-13480668369Fax: +86-18098946792

Technical Contact

Shenzhen Baseus Technology Co., Ltd
[email protected]

China

Test Firm

Shenzhen BCTC Testing Co., Ltd.Sally He
[email protected]15999690624

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.115 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from Shenzhen Baseus Technology Co., Ltd.

2A482-A0010J

Baseus True Wireless Earbuds

Jun 05, 2026

Equipment Class

DTS - Digital Transmission System
Power Bank - FCC ID 2A482-E00337 - Shenzhen Baseus Technology Co., Ltd.
2A482-E00337

Power Bank

May 14, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Power Bank - FCC ID 2A482-E00341 - Shenzhen Baseus Technology Co., Ltd.
2A482-E00341

Power Bank

May 13, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
2A482-A0102A

Baseus Open-Ear TWS Earbuds

Mar 17, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Power bank - FCC ID 2A482-E00334 - Shenzhen Baseus Technology Co., Ltd.
2A482-E00334

Power bank

Feb 10, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz