2A482-PPFM11-1022APower Bank

Shenzhen Baseus Technology Co., Ltd.

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Jan 23, 2026
Application Purpose
Original Equipment
Equipment Note
Power Bank
Frequency Range
0.11050000 - 0.14850000
Company
Shenzhen Baseus Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

ShenzhenBaseusTechnologyCo.,Ltd. 2ndFloor,BuildingB,BaseusIntelligencePark,No.2008,XuegangRd,GangtouCommunity,BantianStreet,Longgang District,Shenzhen,China AttestationStatements NotCoveredEntityApplicant&NotCoveredEquipment To:FederalCommunicationsCommissionDate:Jan.12,2026 7435OaklandMillsRoad, Columbia,MD21046,USA Ref:InformationRequiredbySection2.911(d)(5)(i)&(ii) FCCID:2A482-PPFM11-1022A ShenzhenBaseusTechnologyCo.,Ltd.(“theapplicant”)certifiesthat,asofthedateofthefilingofthe application,theapplicantisnotidentifiedontheCoveredList,establishedpursuantto§1.50002of referencechapter,asanentityproducing“covered”communicationequipment.Theequipmentfor whichauthorizationissoughtisnot“covered”telecommunicationsequipmentandvideosurveillance equipmentproducedbyentitiesidentifiedontheCommission’sCoveredListthatprohibitedfrom receivinganequipmentauthorizationpursuanttosection§2.903oftheFCCrules. Sincerelyyours, ApplicantSignature PrintedName:TiffanyLuo Title:CertifiedEngineer Address:2ndFloor,BuildingB,BaseusIntelligencePark,No.2008,XuegangRd,GangtouCommunity, BantianStreet,LonggangDistrict,Shenzhen,China Tel.:+86-13480668369 ShenzhenBaseusTechnologyCo.,Ltd. 2ndFloor,BuildingB,BaseusIntelligencePark,No.2008,XuegangRd,GangtouCommunity,BantianStreet,Longgang District,Shenzhen,China Email:[email protected]

Attestation Statements

ShenzhenBaseusTechnologyCo.,Ltd. 2ndFloor,BuildingB,BaseusIntelligencePark,No.2008,XuegangRd,GangtouCommunity,BantianStreet,Longgang District,Shenzhen,China Date:Jan.12,2026 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 FCCID:2A482-PPFM11-1022A USAgent–AttestationStatement/Part2.911(d)(7) [ShenzhenBaseusTechnologyCo.,Ltd.]certifies,thatasof[Jan.12,2026],wehavedesignatedFCCUSAgent,LLC toacceptserviceofprocessonourbehalfforFCCID:2A482-PPFM11-1022A. [ShenzhenBaseusTechnologyCo.,Ltd.],acceptstomaintainanagentofserviceofprocessintheUnitedStatesforno lessthanoneyearaftereitherthegranteehaspermanentlyterminatedallmarketingandimportationoftheapplicable equipmentwithintheU.S.,ortheconclusionofanyCommission-relatedadministrativeorjudicialproceedinginvolving theequipment,whicheverislater. FCCUSAgent,LLC,acceptsasofthedateofthefilingofthisapplication,theobligationofbeingthedesignatedagent forthepurposeofacceptingserviceofprocessonbehalfof[ShenzhenBaseusTechnologyCo.,Ltd.]for FCCID:2A482-PPFM11-1022A. DesignatedAgentInformation: CompanyName:FCCUSAgent,LLC FRN:0033402884 Address:3722IllinoisAvenue,SaintCharles,IL,60174,USA ContactPerson:TimPayne Phone:708-571-3148 Email:[email protected] Sincerely, Company:[ShenzhenBaseusTechnologyCo., Ltd.] DesignatedAgent:FCCUSAgent,LLC CompanyRepresentative:[TiffanyLuo] Tel:+86-13480668369 Email:[email protected] FRN:0032035966 DesignatedAgentRepresentative:TimPayne Signature: Signature:

Attestation Statements

ShenzhenBaseusTechnologyCo.,Ltd. 2ndFloor,BuildingB,BaseusIntelligencePark,No.2008,XuegangRd,GangtouCommunity,BantianStreet,Longgang District,Shenzhen,China AttestationStatements NotCoveredEntityApplicant&NotCoveredEquipment To:FederalCommunicationsCommissionDate:Jan.12,2026 7435OaklandMillsRoad, Columbia,MD21046,USA Ref:InformationRequiredbySection2.911(d)(5)(i)&(ii) FCCID:2A482-PPFM11-1022A ShenzhenBaseusTechnologyCo.,Ltd.(“theapplicant”)certifiesthat,asofthedateofthefilingofthe application,theapplicantisnotidentifiedontheCoveredList,establishedpursuantto§1.50002of referencechapter,asanentityproducing“covered”communicationequipment.Theequipmentfor whichauthorizationissoughtisnot“covered”telecommunicationsequipmentandvideosurveillance equipmentproducedbyentitiesidentifiedontheCommission’sCoveredListthatprohibitedfrom receivinganequipmentauthorizationpursuanttosection§2.903oftheFCCrules. Sincerelyyours, ApplicantSignature PrintedName:TiffanyLuo Title:CertifiedEngineer Address:2ndFloor,BuildingB,BaseusIntelligencePark,No.2008,XuegangRd,GangtouCommunity, BantianStreet,LonggangDistrict,Shenzhen,China Tel.:+86-13480668369 ShenzhenBaseusTechnologyCo.,Ltd. 2ndFloor,BuildingB,BaseusIntelligencePark,No.2008,XuegangRd,GangtouCommunity,BantianStreet,Longgang District,Shenzhen,China Email:[email protected]

Cover Letter(s)

ShenzhenBaseusTechnologyCo.,Ltd. 2ndFloor,BuildingB,BaseusIntelligencePark,No.2008,XuegangRd,GangtouCommunity,BantianStreet, LonggangDistrict,Shenzhen,China OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:Jan.12,2026 Subject;RequestforConfidentiality FCCID:2A482-PPFM11-1022A ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram OperationalDescription Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely Contactperson:TiffanyLuo

Cover Letter(s)

Shenzhen Baseus Technology Co., Ltd. 2nd Floor, Building B, Baseus Intelligence Park, No.2008, Xuegang Rd, Gangtou Community, Bantian Street, Longgang District, Shenzhen, China Letter of Authorization Company: Shenzhen Baseus Technology Co., Ltd. Address: 2nd Floor, Building B, Baseus Intelligence Park, No.2008, Xuegang Rd, Gangtou Community, Bantian Street, Longgang District, Shenzhen, China Product Name: Power Bank Model Number(s): PPFM11-1022 Product Description: Power Bank We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: Jan. 12, 2026 Name: Tiffany Luo Title: Certified Engineer Company: Shenzhen Baseus Technology Co., Ltd.

ID Label/Location Info

FCC ID Label Location 50mm*5mm FCC ID: 2A482-PPFM11-1022A

RF Exposure Info

Page 1 of 20 RF Exposure Report Report No.: AGC11758251010FH01 FCC ID : 2A482-PPFM11-1022A APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : Power Bank BRAND NAME : baseus MODEL NAME : PPFM11-1022 APPLICANT : Shenzhen Baseus Technology Co., Ltd. DATE OF ISSUE : Dec. 15, 2025 STANDARD(S) : 47 CFR FCC Part 2.1091 47 CFR FCC Part 2.1093 KDB 680106 D01 v04 REPORT VERSION : V1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC11758251010FH01 Page 2 of 20 Report Revise Record Report Version Revise Time Issued Date Valid Version Notes V1.0 / Dec. 15, 2025 Valid Initial Release Report No.: AGC11758251010FH01 Page 3 of 20 Table of Contents 1. General Information ........................................................................................................................................ 4 2. Product Information ........................................................................................................................................ 5 2.1 Product Technical Description ................................................................................................................... 5 2.2 DUT Coil and Size Information ................................................................................................................. 6 2.3 Related Submittal(S)/Grant (S) ................................................................................................................. 7 2.4 Test Methodology ...................................................................................................................................... 7 2.5 Equipment Approval Considerations ......................................................................................................... 7 3. Test Environment ............................................................................................................................................ 8 3.1 Address of The Test Laboratory ................................................................................................................ 8 3.2 Test Facility ................................................................................................................................................ 8 3.3 Environmental Conditions ......................................................................................................................... 9 3.4 Measurement Uncertainty ......................................................................................................................... 9 3.5 List of Equipment Used ............................................................................................................................. 9 4.System Test Configuration ............................................................................................................................ 10 4.1 Configuration of Tested System .............................................................................................................. 10 4.2 Equipment Used in Tested System ........................................................................................................ 10 5. Description of Test Modes ........................................................................................................................... 11 6. Maximum Permissible Exposure ................................................................................................................. 12 6.1 Test Limits ............................................................................................................................................... 12 6.2 Test Setup (Block Diagram of Configuration).......................................................................................... 13 6.3 Test Procedures ...................................................................................................................................... 15 6.4 Test Result ............................................................................................................................................... 17 Appendix I: Photographs of Test Setup .......................................................................................................... 19 Appendix II: Photographs of Test EUT ........................................................................................................... 19 Report No.: AGC11758251010FH01 Page 4 of 20 1. General Information Applicant Shenzhen Baseus Technology Co., Ltd. Address 2nd Floor, Building B, Baseus Intelligence Park, No.2008, Xuegang Rd, Gangtou Community, Bantian Street, Longgang District, Shenzhen, China Manufacturer Shenzhen Baseus Technology Co., Ltd. Address 2nd Floor, Building B, Baseus Intelligence Park, No.2008, Xuegang Rd, Gangtou Community, Bantian Street, Longgang District, Shenzhen, China Factory N/A Address N/A Product Designation Power Bank Brand Name baseus Test Model PPFM11-1022 Series Model(s) N/A Difference Description N/A Date of receipt of test item Oct. 17, 2025 Date of Test Oct. 17, 2025 to Dec. 12, 2025 Deviation from Standard No any deviation from the test method Condition of Test Sample Normal Test Result Pass Test Report Form No AGCER-FCC-RFE-V1 Note: The test results of this report relate only to the tested sample identified in this report. Prepared By Jack Gui (Project Engineer) Dec. 15, 2025 Reviewed By Bibo Zhang (Reviewer) Dec. 15, 2025 Approved By Angela Li (Authorized Officer) Dec. 15, 2025 Report No.: AGC11758251010FH01 Page 5 of 20 2. Product Information 2.1 Product Technical Description Operation Frequency Band 110.5kHz-148.5kHz Hardware Version REV.B Software Version V1.0 Modulation Type ASK Antenna Designation Coil Antenna Input Rating 5V⎓3A; 9V⎓2.22A by adapter or DC 3.7V by battery Output Rating USB-C Output:5V⎓3A; 9V⎓2.22A; 10V⎓2.25A; 12V⎓1.5A Wireless Output::5W/7.5W/10W/15W Total Output:5V⎓3A Battery Information 1# Manufacturer: Tianjin Juyuan New Energy Technology Co., Ltd Model Name:126280 Ratings: DC 3.7V 1…

Text truncated - open the document above for the full version.

Test Report

Output Power for Each Coil 5W/7.5W/10W/15W Max Distance to transmitter: Top: 1.5mm;Bottom:17.5mm;Left:8.1mm;Right:8.1mm;Front:49.0mm Rear:6.2mm DUT Size (Unit: mm) A B C E F G -- 43.2±0.3 5.4±0.2 43±0.4 7±0.3 15.2±0.4 3±0.3 -- ShenZhen Chenxing Electronic Technology Co., Ltd. Room 510,Building NO. 1,Xinkecheng industrial park, 51 Dabao Road Baoan District Shenzhen City

Test Report

Page 1 of 37 FCC Test Report Report No.: AGC11758251010FR01 FCC ID : 2A482-PPFM11-1022A APPLICATION PURPOSE : Original Equipment PRODUCT DESIGNATION : Power Bank BRAND NAME : baseus MODEL NAME : PPFM11-1022 APPLICANT : Shenzhen Baseus Technology Co., Ltd. DATE OF ISSUE : Dec. 15, 2025 STANDARD(S) : FCC Part 15 Subpart C REPORT VERSION : V1.0 Attestation of Global Compliance (Shenzhen) Co., Ltd Report No.: AGC11758251010FR01 Page 2 of 37 Report Revise Record Report Version Revise Time Issued Date Valid Version Notes V1.0 / Dec. 15, 2025 Valid Initial Release Report No.: AGC11758251010FR01 Page 3 of 37 Table of Contents 1. General Information ........................................................................................................................................ 4 2. Product Information ........................................................................................................................................ 5 2.1 Product Technical Description ................................................................................................................... 5 2.2 Related Submittal(S) / Grant (S) ............................................................................................................... 6 2.3 Test Methodology ...................................................................................................................................... 6 2.4 Special Accessories .................................................................................................................................. 6 2.5 Equipment Modifications ........................................................................................................................... 6 2.6 Antenna Requirement................................................................................................................................ 6 3. Test Environment ............................................................................................................................................ 7 3.1 Address of The Test Laboratory ................................................................................................................ 7 3.2 Test Facility ................................................................................................................................................ 7 3.3 Environmental Conditions ......................................................................................................................... 8 3.4 Measurement Uncertainty ......................................................................................................................... 8 3.5 List of Equipment Used ............................................................................................................................. 9 4. System Test Configuration ........................................................................................................................... 10 4.1 EUT Configuration ................................................................................................................................... 10 4.2 EUT Exercise ........................................................................................................................................... 10 4.3 Configuration of Tested System .............................................................................................................. 10 4.4 Equipment Used in Tested System ......................................................................................................... 11 4.5 Summary of Test Results ........................................................................................................................ 12 5. Description of Test Modes ........................................................................................................................... 13 6. Field Strength of Fundamental .................................................................................................................... 14 6.1 Measurement Limits ................................................................................................................................ 14 6.2 Measurement Procedure ......................................................................................................................... 15 6.3 Field Strength Calculation ....................................................................................................................... 16 6.4 Measurement Setup ................................................................................................................................ 17 6.5 Measurement Result ............................................................................................................................... 18 7. -20 dB Bandwidth Measurement ................................................................................................................. 30 7.1 Provisions Applicable .............................................................................................................................. 30 7.2 Measurement Procedure ......................................................................................................................... 30 7.3 Measurement Setup ................................................................................................................................ 30 7.4 Measurement Result ............................................................................................................................... 30 8. AC Power Line Conducted Emission Test .................................................................................................. 32 8.1 Measurement Limits ................................................................................................................................ 32 8.2 Measurement Setup ..........................................................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Tiffany Luo(Certified Engineer)
[email protected]Fax: +86-18098946792

Technical Contact

FCC US Agent, LLCTim Payne
[email protected]

3722 Illinois Avenue, Saint Charles, IL, 60174, · Saint Charles, Illinois, 60174 · United States

Test Firm

Attestation of Global Compliance (Shenzhen) Co., LDoris Li
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.1105 MHz - 0.1485 MHz-
Confidentiality
Long Term

Other Applications from Shenzhen Baseus Technology Co., Ltd.

2A482-A0010J

Baseus True Wireless Earbuds

Jun 05, 2026

Equipment Class

DTS - Digital Transmission System
Power Bank - FCC ID 2A482-E00337 - Shenzhen Baseus Technology Co., Ltd.
2A482-E00337

Power Bank

May 14, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Power Bank - FCC ID 2A482-E00341 - Shenzhen Baseus Technology Co., Ltd.
2A482-E00341

Power Bank

May 13, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
2A482-A0102A

Baseus Open-Ear TWS Earbuds

Mar 17, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Power bank - FCC ID 2A482-E00334 - Shenzhen Baseus Technology Co., Ltd.
2A482-E00334

Power bank

Feb 10, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz