Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Typhur Inc. U.S. Agent Letter of Attestation To: Federal Communications Commission Date: 2024-01-03 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Attestation Statement – Part 2.911(d)(7) filing FCC ID: 2A6RN-WT1000R Shenzhen Typhur Technology Co., Ltd. (“the applicant”) certifies that, as of the date of the filing of the application, Typhur Inc. (“the agent”) is our designated U.S. agent for service of process for the above reference FCC ID. The applicant accepts to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. The applicant further acknowledges it is our responsibility to inform the FCC whenever the agent information changes. Typhur Inc. (“the agent”) understand it is the agent's obligation to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address. APPLICANT Company Name: Shenzhen Typhur Technology Co., Ltd. Contact Person: Wilson Huang Address: Prince Plaza 2201-2206, 51 Taizi Road, Shuiwan Community, Zhaoshang Street, Nanshan District, Shenzhen, Guangdong, China Email: [email protected] U.S. Agent Company Name: Typhur Inc. Contact Person: Allen Fung Address: 2890 Zanker Rd, Suite 120, San Jose, CA 95134 Email: [email protected] Note1: Typhur Inc. does not do any other business with the FCC. Note2: This letter is to confirm that we have accepted the responsibility to act as US Agent on behalf of Shenzhen Typhur Technology Co., Ltd (“the applicant”) for the above Grantee code. Sincerely yours, The Applicant The Agent Company Name Shenzhen Typhur Technology Co., Ltd. Typhur Inc. Contact Person Wilson Huang Allen Fung Signature FRN: 0032366403
Shenzhen Typhur Technology Co., Ltd. Attestation Statements Not Covered Entity Applicant To: Federal Communications Commission Date: 2024-01-03 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(ii) filing FCC ID: 2A6RN-WT1000R Shenzhen Typhur Technology Co., Ltd. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely yours, Applicant Signature Printed Name: Wilson Huang Title: Certification Engineer Email: [email protected]
Shenzhen Typhur Technology Co., Ltd. Attestation Statements Not Covered Equipment To: Federal Communications Commission Date: 2024-01-03 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(i) filing FCC ID: 2A6RN-WT1000R Shenzhen Typhur Technology Co., Ltd. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section § 2.903 of the FCC rules. Sincerely yours, Applicant Signature Printed Name: Wilson Huang Title: Certification Engineer Email: [email protected]
TCB Authority to Act as Agent Number: MS-0045317 Revision: 0 Effective date: Oct 8, 2021 Page 1 of 1 Shenzhen Typhur Technology Co., Ltd. Authority to Act as Agent Date: 2024-01-03 TUV Rheinland of North America, Inc. 1279 Quarry Lane., Suite. A Pleasanton, CA 94566 To Whom It May Concern: I appoint TÜV Rheinland (Shenzhen) Co., Ltd. to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the FCC or Industry Canada’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by TUV Rheinland Group, still resides with Shenzhen Typhur Technology Co., Ltd., Prince Plaza 2201-2206, 51 Taizi Road, Shuiwan Community, Zhaoshang Street, Nanshan District, Shenzhen, Guangdong, China. For TCB applications, We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Date: 2024-01-03 Agreement is valid for 12 months from the above date. Applicant Signature Printed Name: Wilson Huang Title: Certification Engineer Email: [email protected] On behalf of Shenzhen Typhur Technology Co., Ltd.
Standard Form Sample Request for Confidentiality Letter MS-0044715 Page 1 of 1 Revision 0 Shenzhen Typhur Technology Co., Ltd. Date: 2024-01-03 Subject: Confidentiality Request for FCC ID: 2A6RN-WT1000R and IC: 28517-WT1000R Pursuant to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 10, the applicant requests that a part of the subject FCC/IC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term n/a External Photo Short Term Permanent Internal Photos *** Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Schematics Short Term Permanent Test Setup*** Short Term Permanent Tune-Up Procedure Short Term Permanent User’s Manual*** Short Term Permanent Part List/ Antenna Gain Information Datasheet Shenzhen Typhur Technology Co., Ltd. has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. (*** PAG only) Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify TUV Rheinland in the event information regarding the product or the product is made available to the public. TUV Rheinland will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, Applicant Signature Printed Name: Wilson Huang Title: Certification Engineer Email: [email protected]
Data reference Letter Page 1 of 1 Shenzhen Typhur Technology Co., Ltd. Prince Plaza 2201-2206, 51 Taizi Road, Shuiwan Community, Zhaoshang Street, Nanshan District, Shenzhen, Guangdong, China Date: 2024-05-07 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 USA Innovation, Science and Economic Development Canada 3701 Carling Avenue (Building 94), Ottawa, Ontario, K2H 8S2 To Whom It May Concern: Request for FCC and IC Data reference: Data reference request on: Product Model: WT1000R FCC ID: 2A6RN-WT1000R IC: 28517-WT1000R Original FCC and IC ID information Product Model: WT1000 FCC ID: 2A6RN-WT1000 (grant date: 08/21/2023) IC: 28517-WT1000 (grant date: 08/25/2023) For the above device and pursuant to KDB 484596 D01 Referencing Test Data v02r03, Shenzhen Typhur Technology Co., Ltd. Wireless module (WT1000R) hereby requests the data reference for FCC and IC certification, detail difference description refer below. *Single Modular Single Modular (updated Bluetooth firmware) Items Value Items Value Bluetooth Max. Conducted Output power: Bluetooth LE 1Mbps: 11.95dBm Bluetooth LE 2Mbps: 12.97dBm Bluetooth firmware Updated Bluetooth firmware only and the other are same as before. And the RF output power up to 20dBm. • The wireless module test data refers to test report FR1D1609A, FR1D1609B, CR1D1609ATX and CR1D1609BTX as issued by Sporton International Inc. (Kunshan). • There is no other change in hardware or in existing RF relevant portion of the product, and only updated the Bluetooth firmware. • There is no any software/firmware that can be modified by end-user. • Based on the above difference description, fully test on the Bluetooth LE mode, including the Wireless and EMF evaluation and additional spot check test for WiFi conducted output power. Sincerely, Applicant Signature Printed Name: Wilson Huang Title: Certification Engineer Email: [email protected] Note: original ID is transfered from FCC ID: 2AC7Z-ESPS3WROOM1U and IC: 21098-ESPS3WROOMU. 1. Reference device 1.1. General information of product • FCC ID: 2A6RN-WT1000 • Data of Grant: 08/21/2023 • Product Type: Single Modular • Equipment Class: DTS • FCC Rule: FCC Part 15.247 • Operation frequency: 2412-2462MHz for WiFi, 2402-2480MHz for Bluetooth LE • Wireless mode: 2.4GHz WiFi up to 802.11n40, Bluetooth LE mode (1Mbps, 2Mbps) • Refer test report: FR1D1609A and FR1D1609B as issued by Sporton International Inc.(Kunshan). • Product photos (Single Modular): Front view Rear view 1.2. 2.4GHz Wi-Fi RF Output Power 1.3. Bluetooth LE RF Output Power 2. Variant Device 2.1. General information of Variant Device • FCC ID: 2A6RN-WT1000R • Data of Grant: PAG firstly. • Product Type: Single Modular • Equipment Class: DTS • FCC Rule: FCC Part 15.247 • Operation frequency: 2412-2462MHz for WiFi, 2402-2480MHz for Bluetooth LE • Wireless mode: 2.4GHz WiFi up to 802.11n40, Bluetooth LE mode (1Mbps, 2Mbps) • Product photos (Single Modular): Front view Rear view 2.2. Data Referencing Applicability The variant model WT1000R are same as the FCC ID: 2A6RN-WT1000 hardware designed including PCB Layout, Circuit Diagram, Product size, and only difference on the Bluetooth mode firmware, As the Bluetooth LE upgraded with firmware to increase its power up to 20dBm. 2.3. Spot-Check Plan for 2.4GHz Wi-Fi mode 2.4GHz Wi-Fi mode Rule Part Test item Data Referencing Comments 15.203 Antenna Requirement Y *FCC Part 15.247(b)(3) Transmitter Output Power N Retest FCC Part 15.247(e) Transmitter Power Spectral Density Y FCC Part 15.247(a)(2) 6dB Bandwidth Y FCC Part 15.247(d) Band Edge / Out-of-Band Emissions Y FCC Part 15.205 & FCC Part 15.209 General Field Strength Limits (Restricted Bands and Radiated Emissions Limits) Y *Note: The 2.4GHz Wi-Fi power verification is used to ensure that the upgrading Bluetooth LE firmware does not affect the power of 2.4GHz Wi-Fi. 2.4GHz Wi-Fi spot check RF Output Power test data: Test Mode Test Channel (MHz) Measured Peak Power (dBm) 11B 2412 18.69 2437 15.43 2462 16.77 11G 2412 23.17 2437 24.94 2462 23.61 11N20 2412 23.28 2437 23.79 2462 23.31 11N40 2422 22.83 2437 23.52 2452 23.18 2.4. Additional testing with Bluetooth LE mode Bluetooth mode (1Mbps, 2Mbps) Rule Part Test item Data Referencing Comments 15.203 Antenna Requirement Y *FCC Part 15.247(b)(3) Transmitter Output Power N Retest FCC Part 15.247(e) Transmitter Power Spectral Density N Retest FCC Part 15.247(a)(2) 6dB Bandwidth N Retest FCC Part 15.247(d) Band Edge / Out-of-Band Emissions N Retest FCC Part 15.205 & FCC Part 15.209 General Field Strength Limits (Restricted Bands and Radiated Emissions Limits) N Retest *Note: The following data only shows the power of Bluetooth LE. Bluetooth RF output power Test Mode Test Channel (MHz) Measured Peak Power Limit (W) (dBm) (W) Bluetooth LE (1 Mbps) 2402 18.77 0.0753 < 1.0 2440 19.05 0.0804 2480 18.95 0.0785 Max. Measured Value 19.05 0.0804 Bluetooth LE (2 Mbps) 2402 18.97 0.0789 2440 19.48 0.0887 2480 19.37 0.0865 Max. Measured Value 19.48 0.0887
Label and Location
Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN23JYNK 002 Auftrags-Nr.: Order no.: 168454745 Seite 1 von 10 Page 1 of 10 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2023-12-01 Auftraggeber: Client: Shenzhen Typhur Technology Co., Ltd. Prince Plaza 2201-2206, 51 Taizi Road, Shuiwan Community, Zhaoshang Street, Nanshan District, Shenzhen, Guangdong, China Prüfgegenstand: Test item: 2.4GHz Wi-Fi & BT IoT Module Bezeichnung / Typ-Nr.: Identification / Type no.: WT1000R Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: CFR47 FCC Part 2.1091 RSS-102 Issue 5 February 2021 Wareneingangsdatum: Date of sample receipt: 2023-12-01 Please refer to Photo Document Prüfmuster-Nr.: Test sample no: A003612973-001~002 Prüfzeitraum: Testing period: 2023-12-04 - 2023-12-20 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: genehmigt von: authorized by: Datum: Date: 2024-05-31 Ausstellungsdatum: Issue date: 2024-05-31 Stellung / Position: Sachverständige(r)/Expert Stellung / Position: Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2A6RN-WT1000R IC: 28517-WT1000R, HVIN: WT1000R Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shenzhen) Co., Ltd., 1601-1604, 17-18F, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen 518052, P. R. China Mail: [email protected] · Web: www.tuv.com Lin Lin Hardy Suo Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN23JYNK 002 Test report no.: Seite 2 von 10 Page 2 of 10 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2021, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos durch diese Entscheidungsregel siehe ILAC G8:2019. The decision rule for statements of conformity, based on numerical measurement results, in this test report is based on the “Zero Guard Band Rule” and “Simple Acceptance” in accordance with ILAC G8:2019 and IEC Guide 115:2021, unless otherwise specified in the…
Text truncated - open the document above for the full version.
深圳市安特通讯科技有限公司 ANT Communication Technology(Shenzhen) Co., LTD. HUYI TECHNOLOGY LTD Antenna Test Report Tester : Li Yuanhao Approval : Liu Feng Date : 2023 / 07 / 5 深圳市安特通讯科技有限公司 ANT Communication Technology(Shenzhen) Co., LTD. 2.4G WIFI/BT Test Antenna: Monopole antenna Frequency: 2.4GHz 深圳市安特通讯科技有限公司 ANT Communication Technology(Shenzhen) Co., LTD. Passive Test For 2.4G WIFI/BT Frequency/MhzEfficiency/dBEfficiency/%MaxGain/dBi 2400 -4 39.21.7 2410 -3.8 41.11.8 2420 -3.9 40.11.8 2430 -3.5 43.92.2 2440 -3.7 41.72.0 2450 -3.7 42.22.1 2460 -3.9 40.21.9 2470 -3.8 41.32.0 2480 -3.5 43.72.2 2490 -4 39.81.8 2500 -3.8 41.41.9 深圳市安特通讯科技有限公司 ANT Communication Technology(Shenzhen) Co., LTD. OTA test data WIFI B(11M) channel1611 TRP(dBm) 12.112.212.1 TIS(dBm) -81.7-81.7-81.8 BLE channel0// TRP(dBm) -5.5// 深圳市安特通讯科技有限公司 ANT Communication Technology(Shenzhen) Co., LTD. Real machine testing Location: Our campus Distance: ≥70 meters 深圳市安特通讯科技有限公司 ANT Communication Technology(Shenzhen) Co., LTD. 深圳市安特通讯科技有限公司 ANT Communication Technology(Shenzhen) Co., LTD. THANK YOU!
Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN23JYNK 001 Auftrags-Nr.: Order no.: 168454745 Seite 1 von 23 Page 1 of 23 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2023-12-01 Auftraggeber: Client: Shenzhen Typhur Technology Co., Ltd. Prince Plaza 2201-2206, 51 Taizi Road, Shuiwan Community, Zhaoshang Street, Nanshan District, Shenzhen, Guangdong, China Prüfgegenstand: Test item: 2.4GHz Wi-Fi & BT IoT Module Bezeichnung / Typ-Nr.: Identification / Type no.: WT1000R Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: CFR47 FCC Part 15: Subpart C Section 15.247 RSS-247 Issue 3 August 2023 RSS-Gen Issue 5 February 2021 Wareneingangsdatum: Date of sample receipt: 2023-12-01 Please refer to Photo Document Prüfmuster-Nr.: Test sample no: A003612973-001~002 Prüfzeitraum: Testing period: 2023-12-04 - 2023-12-20 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: genehmigt von: authorized by: Datum: Date: 2024-05-31 Ausstellungsdatum: Issue date: 2024-05-31 Stellung / Position: Sachverständige(r)/Expert Stellung / Position: Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2A6RN-WT1000R IC: 28517-WT1000R, HVIN: WT1000R Note: This report based on the original wireless module (FCC ID: 2A6RN-WT1000 and IC: 28517-WT1000) to updated the bluetooth mode firmware and the other are same as original one, since these changed, re-test all test items of Bluetooth mode and spot check the WiFi output peak power. Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shenzhen) Co., Ltd., 1601-1604, 17-18F, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen 518052, P. R. China Mail: [email protected] · Web: www.tuv.com Lin Lin Hardy Suo Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN23JYNK 001 Test report no.: Seite 2 von 23 Page 2 of 23 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2021, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen …
Text truncated - open the document above for the full version.
Prüfbericht - Produkte Test Report - Products Appendix A CN23JYNK 001 Page 1 of 43 Appendix A: Test Results of Bluetooth LE & Conducted Emission APPENDIX A: TEST RESULTS OF BLUETOOTH LE & CONDUCTED EMISSION .................................................................... 1 APPENDIX A.1: TEST RESULTS OF CONDUCTED POWER SPECTRAL DENSITY ..................................................................................... 2 APPENDIX A.2: TEST RESULTS OF 6DB BANDWIDTH ................................................................................................................... 5 APPENDIX A.3: TEST RESULTS OF 99% BANDWIDTH ................................................................................................................... 8 APPENDIX A.4: TEST RESULTS OF CONDUCTED SPURIOUS EMISSIONS MEASURED IN 100 KHZ BANDWIDTH ...................................... 11 Band Edge ................................................................................................................................................................... 11 Conducted Spurious Emission ..................................................................................................................................... 13 APPENDIX A.5: TEST RESULTS OF RADIATED SPURIOUS EMISSIONS ............................................................................................. 20 30 MHz - 1GHz ............................................................................................................................................................ 20 1GHz - 18GHz .............................................................................................................................................................. 22 APPENDIX A.6: TEST RESULTS OF RADIATED EMISSIONS IN RESTRICTED BANDS ............................................................................. 34 APPENDIX A.7: TEST RESULTS OF CONDUCTED EMISSION ON AC MAINS...................................................................................... 42 Prüfbericht - Produkte Test Report - Products Appendix A CN23JYNK 001 Page 2 of 43 Appendix A.1: Test Results of Conducted Power Spectral Density TestMode Antenna Channel Result [dBm/3-100kHz] Limit [dBm/3kHz] Verdict BLE_1M Ant1 2402 3.21 ≤8.00 PASS 2440 3.57 ≤8.00 PASS 2480 3.45 ≤8.00 PASS BLE_2M Ant1 2402 1.71 ≤8.00 PASS 2440 2.30 ≤8.00 PASS 2480 2.10 ≤8.00 PASS Prüfbericht - Produkte Test Report - Products Appendix A CN23JYNK 001 Page 3 of 43 BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Prüfbericht - Produkte Test Report - Products Appendix A CN23JYNK 001 Page 4 of 43 BLE_2M_Ant1_2402 BLE_2M_Ant1_2440 BLE_2M_Ant1_2480 Prüfbericht - Produkte Test Report - Products Appendix A CN23JYNK 001 Page 5 of 43 Appendix A.2: Test Results of 6dB Bandwidth TestMode Antenna Channel DTS BW [MHz] FL [MHz] FH [MHz] Limit [MHz] Verdict BLE_1M Ant1 2402 0.628 2401.680 2402.308 0.5 PASS 2440 0.636 2439.672 2440.308 0.5 PASS 2480 0.616 2479.684 2480.300 0.5 PASS BLE_2M Ant1 2402 1.116 2401.444 2402.560 0.5 PASS 2440 1.252 2439.340 2440.592 0.5 PASS 2480 1.120 2479.448 2480.568 0.5 PASS Prüfbericht - Produkte Test Report - Products Appendix A CN23JYNK 001 Page 6 of 43 BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Prüfbericht - Produkte Test Report - Products Appendix A CN23JYNK 001 Page 7 of 43 BLE_2M_Ant1_2402 BLE_2M_Ant1_2440 BLE_2M_Ant1_2480 Prüfbericht - Produkte Test Report - Products Appendix A CN23JYNK 001 Page 8 of 43 Appendix A.3: Test Results of 99% Bandwidth TestMode Antenna Channel OCB [MHz] FL [MHz] FH [MHz] Limit [MHz] Verdict BLE_1M Ant1 2402 1.0361 2401.4835 2402.5196 --- PASS 2440 1.0208 2439.4852 2440.5060 --- PASS 2480 1.0266 2479.4823 2480.5089 --- PASS BLE_2M Ant1 2402 2.0501 2400.9885 2403.0386 --- PASS 2440 2.0315 2438.9931 2441.0246 --- PASS 2480 2.0332 2478.9864 2481.0196 --- PASS Prüfbericht - Produkte Test Report - Products Appendix A CN23JYNK 001 Page 9 of 43 BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Prüfbericht - Produkte Test Report - Products Appendix A CN23JYNK 001 Page 10 of 43 BLE_2M_Ant1_2402 BLE_2M_Ant1_2440 BLE_2M_Ant1_2480 Prüfbericht - Produkte Test Report - Products Appendix A CN23JYNK 001 Page 11 of 43 Appendix A.4: Test Results of Conducted Spurious Emissions Measured in 100 kHz Bandwidth Band Edge TestMode Antenna ChName Channel RefLevel [dBm] Result [dBm] Limit [dBm] Verdict BLE_1M Ant1 Low 2402 17.12 -38.2 ≤-2.88 PASS High 2480 15.98 -44.91 ≤-4.02 PASS BLE_2M Ant1 Low 2402 15.4 -35.16 ≤-4.6 PASS High 2480 18.12 -43.17 ≤-1.88 PASS BLE_1M_Ant1_Low_2402 BLE_1M_Ant1_High_2480 Prüfbericht - Produkte Test Rep…
Text truncated - open the document above for the full version.
Prince Plaza 2201-2206, 51 Taizi Road, Shuiwan · Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.41 GHz - 2.46 GHz | 324.30 mW |

Typhur Wireless Thermometer Probe
Equipment Class
DTS - Digital Transmission System
Sous Vide
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzT1 Wireless
Equipment Class
DTS - Digital Transmission System