Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Frequency band of operation is 2400 to 2483.5 MHz. Maximum transmit power less than 20 dBm EIRP. [Shenzhen Typhur Technology Co., Ltd] hereby declares that the radio equipment type [WT03] is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following Internet address: https://explore.typhur.com/ce-declaration [Shenzhen Typhur Technology Co., Ltd] hereby declares that the radio equipment type [WT03] is in compliance with Radio Equipment Regulations 2017. The full text of the declaration of conformity is available at the following internet address: https://explore.typhur.com/ce-declaration. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference (2) This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. CAUTION: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC Radiation Exposure Statement: The device complies with RF specifications when used near your body at a distance of 10 mm. Ensure that the device accessories, such as a device case and device holster, are not composed of metal components. Keep the device away from your body to meet the distance requirement. FCC Supplier’s Declaration of Conformity Product Name: Typhur Sync Wireless Thermometer Model number: W T03 Suppliers Name: Typhur Inc. Suppliers Address (USA): 2890 Zanker Rd, Suite 120, San Jose, CA 95134 Suppliers contact mail: [email protected] ISED Statement This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: 1This device may not cause interference. 2This device must accept any interference, including interference that may cause undesired operation of the device. This equipment complies with Industry Canada radiation exposure limits set forth for an uncontrolled environment. Using for the First Time: Before using your Typhur Sync, ensure the product is fully charged and you have reviewed the important safety information. Download the free Typhur App for iOS or Android. Insert the probe completely into the meat, ensuring that it passes the Safe Notch and that the 4 internal sensors are in the center of the meat. UKUS 1. 2. 3. For Europe: Temperature Adjustment While cooking, you can press the "O" button to access the "Settings" to adjust the target temperature. FCC Statement: Temperature Setting Unplug either Probe to be used, and the Device Base's screen will display the "Set Temp" prompt. Stopping Cooking Press the "O" button, access the "Settings" menu, and select "Stop the Current Cooking". Cooking States Remove from heat: This state indicates that the food should be removed from the heat source. Resting: The food has entered a resting state, allowing the residual heat to continue to rise. Ready: The food is cooked and ready to be served. Click "O" button to end the cooking process. Support Please contact our Customer Support Team if you have any questions. : 1(888) 838-6563 (USA) : [email protected] : www.typhur.com/contact-us (USA), uk.typhur.com/contact-us (UK) User Manual v1.0 Typhur Sync Certifications Trouble Shooting Device Base Prompt "Probe Battery Low" The Probe's battery power is at a low level. Plug the Probe into the Device Base to charge it. Use the included Type-C USB cable to charge the Device Base. Unplug both probes and tap "Repair" on the base. Tap "Search" on the base. Remove the Probe from the heat source and allow it to cool down before using it again. Contact our customer support team for assistance. They will be able to help you diagnose and resolve the issue. "Device Battery Low" The Device Base's battery power is at a low level. The Probe has been exposed to an overheated environment. "Overheating" "Error 403" "Probe Lost" "Probe Disconnected" There may be a software, hardware, sensor, or communication failure. The Probe and the base need to be repaired. The Probe is disconnected from the base. Possible CauseSolution 01020304 05060708 09101112 16 Important Safeguards Diagram SAVE THESE INSTRUCTIONS Please read this entire manual before using your Typhur Sync. Failure to follow these instructions could result in property damage or bodily injury. CAUTION DO NOT use the Probe when cooking at temperatures above 572°F / 300°C or directly above hot coals or open flame. DO NOT place the Device Base unit directly on the grill cover or close to any hot surface. DO NOT use the Probe in a microwave or pressure cooker. DO NOT use cleaning products containing alcohol, ammonium, benzene, or abrasives, all of which could damage the device. DO NOT submerge the Probe in wa…
Text truncated - open the document above for the full version.
Shenzhen Typhur Technology Co., Ltd. Attestation Statements Not Covered Entity Applicant To: Federal Communications Commission Date: 07/05/2023 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(ii) filing FCC ID: 2A6RN-WTP1000 Shenzhen Typhur Technology Co., Ltd. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely yours, Applicant Signature Printed Name: Wilson Huang Title: Certification Engineer Email: [email protected]
Shenzhen Typhur Technology Co., Ltd. Attestation Statements Not Covered Equipment To: Federal Communications Commission Date: 07/05/2023 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(i) filing FCC ID: 2A6RN-WTP1000 Shenzhen Typhur Technology Co., Ltd. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section § 2.903 of the FCC rules. Sincerely yours, Applicant Signature Printed Name: Wilson Huang Title: Certification Engineer Email: [email protected]
TCB Authority to Act as Agent Number: MS-0045317 Revision: 0 Effective date: Oct 8, 2021 Page 1 of 1 Shenzhen Typhur Technology Co., Ltd. Authority to Act as Agent Date: 07/05/2023 TUV Rheinland of North America, Inc. 1279 Quarry Lane., Suite. A Pleasanton, CA 94566 To Whom It May Concern: I appoint TÜV Rheinland (Shenzhen) Co., Ltd. to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the FCC or Industry Canada’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by TUV Rheinland Group, still resides with Shenzhen Typhur Technology Co., Ltd., 22 Floor, Prince Plaza, 51 Taizi Road Shuiwan Community, Zhaoshang Street, Nanshan, Shenzhen, China. For TCB applications, We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Date: 07/05/2023 Agreement is valid for 12 months from the above date. Applicant Signature Printed Name: Wilson Huang Title: Certification Engineer Email: [email protected] On behalf of Shenzhen Typhur Technology Co., Ltd.
Standard Form Sample Request for Confidentiality Letter MS-0044715 Page 1 of 1 Revision 0 Shenzhen Typhur Technology Co., Ltd. Date: 07/05/2023 Subject: Confidentiality Request for FCC ID: 2A6RN-WTP1000 and IC: 28517-WTP1000 Pursuant to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 10, the applicant requests that a part of the subject FCC/IC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term n/a External Photo Short Term Permanent Internal Photos *** Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Schematics Short Term Permanent Test Setup*** Short Term Permanent Tune-Up Procedure Short Term Permanent User’s Manual*** Shenzhen Typhur Technology Co., Ltd. has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. (*** PAG only) Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify TUV Rheinland in the event information regarding the product or the product is made available to the public. TUV Rheinland will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, Applicant Signature Printed Name: Wilson Huang Title: Certification Engineer Email: [email protected]
Label Location Due to the probe material and size of product, according to FCC KDB 784748 D01, the certification number are included in the user guide and packaging. Below is a screenshot of the screen from user guide and packaging. Instructions Label information: Packaging Label information:
深圳市安特通讯科技有限公司 ANT Communication Technology(Shenzhen) Co., LTD. Project content : 2400-2500MHZ Antenna commissioning report Tester : Li Yuanhao Approval : Liu Feng Date : 2023 / 07 / 10 701, Building A, No. 10 Jiangfu Road, Xinzhuang Community, Matian Street, Guangming District, Shenzhen, China 深圳市安特通讯科技有限公司 ANT Communication Technology(Shenzhen) Co., LTD. SATIMO-16XH-24-5GCUM GOCMU RUN Agilent 8960 R&S CMW500 Anritsu MT8820C Agilent 5071C Test the systemTest the environmentActive testingPassive testing SATIMO-16 temperature 22°C±3°C humidity 50%±15% 2G/3G/4G/5G GPS/WIFI/BT 400M-8.5G XH-24 星河亮点SP9500 深圳市安特通讯科技有限公司 ANT Communication Technology(Shenzhen) Co., LTD. Passive Test For 2.4G WIFI/BT Frequency/MhzEfficiency/dBEfficiency/%MaxGain/dBi 2400 -5.925.4 0.3 2410 -5.825.9 0.5 2420 -5.826.3 0.9 2430 -5.726.7 1.1 2440 -5.627.5 1.5 2450 -5.527.9 1.6 2460 -5.428.6 2.0 2470 -5.329.5 2.3 2480 -5.230.1 2.4 2490 -5.329.4 2.1 2500 -5.527.9 1.8 深圳市安特通讯科技有限公司 ANT Communication Technology(Shenzhen) Co., LTD. Remark: The above is the test data, please know! Please feel free to contact if you have any questions, thank you!! 深圳市安特通讯科技有限公司 ANT Communication Technology(Shenzhen) Co., LTD. THANK YOU!
Safety Human Exposure 1.1 Radio Frequency Exposure Compliance 1.1.1 Electromagnetic Fields RESULT: Pass Report No. : CN23LRWL 004 Test Specification Test item : Typhur Wireless Thermometer Identification / Type No. : WT03 FCC ID : 2A6RN-WTP1000 IC : 28517-WTP1000 HVIN : WT03 Test standard : CFR47 FCC Part 2: Section 2.1093 FCC KDB Publication 447498 v06 RSS-102 Issue 5 February 2021 Measurement Record: The minimum distance for the EUT is less than 5mm. For FCC: Since maximum average output power of the transmitter is 5.90 dBm ≈ 3.89 mW < 3*d f = 9.52 mW. Hence the EUT is excluded from SAR evaluation according to FCC KDB Publication 447498 D01 General RF Exposure Guidance v06. For IC: The higher of the maximum e.i.r.p. or conducted power of the transmitter is 5.90 dBm ≈ 3.89 mW, which is below the SAR exclusion threshold level 4 mW ≈ 6.02 dBm. Hence the EUT is exempted from routine evaluation limits (SAR Evaluation) according to clause 2.5.1 of RSS-102 Issue 5.
Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN23LRWL 003 Auftrags-Nr.: Order no.: 168431635 Seite 1 von 22 Page 1 of 22 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2023-06-19 Auftraggeber: Client: Shenzhen Typhur Technology Co., Ltd. Prince Plaza 2201-2206, 51 Taizi Road, Shuiwan Community, Zhaoshang Street, Nanshan District, Shenzhen, Guangdong, China Prüfgegenstand: Test item: Typhur Wireless Thermometer Bezeichnung / Typ-Nr.: Identification / Type no.: WT03 Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: CFR47 FCC Part 15: Subpart C Section 15.247 RSS-247 Issue 2 February 2017 RSS-Gen Issue 5 April 2018 Wareneingangsdatum: Date of sample receipt: 2023-07-04 Please refer to Photo Document Prüfmuster-Nr.: Test sample no: A003497474-001~003 Prüfzeitraum: Testing period: 2023-07-06 - 2023-07-25 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: genehmigt von: authorized by: Datum: Date: 2023-08-02 Ausstellungsdatum: Issue date: 2023-08-02 Stellung / Position: Sachverständige(r)/Expert Stellung / Position: Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2A6RN-WTP1000 IC: 28517-WTP1000, HVIN: WT03 Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shenzhen) Co., Ltd., 1601-1604, 17-18F, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen 518052, P. R. China Mail: [email protected] · Web: www.tuv.com Lin Lin Hardy Suo Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN23LRWL 003 Test report no.: Seite 2 von 22 Page 2 of 22 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2021, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos durch diese Entscheidungsregel siehe ILAC G8:2019. The decision rule for statements of conformity, based on numerical measurement results, in this test report is based on the “Zero Guard Band Rule” and “Simple Acceptance” in accordance with ILAC G8:2019 and IEC Guide 1…
Text truncated - open the document above for the full version.
Prüfbericht - Produkte Test Report - Products Appendix A CN23LRWL 003 Page 1 of 39 Appendix A: Test Results of Bluetooth LE & Conducted Emission APPENDIX A: TEST RESULTS OF BLUETOOTH LE & CONDUCTED EMISSION .................................................................... 1 APPENDIX A.1: TEST RESULTS OF CONDUCTED POWER SPECTRAL DENSITY ..................................................................................... 2 APPENDIX A.2: TEST RESULTS OF 6DB BANDWIDTH ................................................................................................................... 5 APPENDIX A.3: TEST RESULTS OF 99% BANDWIDTH ................................................................................................................... 8 APPENDIX A.4: TEST RESULTS OF CONDUCTED SPURIOUS EMISSIONS MEASURED IN 100 KHZ BANDWIDTH ...................................... 11 Band Edge ................................................................................................................................................................... 11 Conducted Spurious Emission ..................................................................................................................................... 13 APPENDIX A.5: TEST RESULTS OF RADIATED SPURIOUS EMISSIONS ............................................................................................. 20 30 MHz - 1GHz ............................................................................................................................................................ 20 1GHz - 18GHz .............................................................................................................................................................. 22 APPENDIX A.6: TEST RESULTS OF RADIATED EMISSIONS IN RESTRICTED BANDS ............................................................................. 34 APPENDIX A.7: TEST RESULTS OF CONDUCTED EMISSION ON AC MAINS...................................................................................... 38 Prüfbericht - Produkte Test Report - Products Appendix A CN23LRWL 003 Page 2 of 39 Appendix A.1: Test Results of Conducted Power Spectral Density TestMode Antenna Channel Result[dBm/3kHz] Limit[dBm/3kHz] Verdict BLE_1M Ant1 2402 -11.21 ≤8.00 PASS 2440 -12.37 ≤8.00 PASS 2480 -14.11 ≤8.00 PASS BLE_2M Ant1 2402 -13.7 ≤8.00 PASS 2440 -14.85 ≤8.00 PASS 2480 -16.56 ≤8.00 PASS Prüfbericht - Produkte Test Report - Products Appendix A CN23LRWL 003 Page 3 of 39 BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Prüfbericht - Produkte Test Report - Products Appendix A CN23LRWL 003 Page 4 of 39 BLE_2M_Ant1_2402 BLE_2M_Ant1_2440 BLE_2M_Ant1_2480 Prüfbericht - Produkte Test Report - Products Appendix A CN23LRWL 003 Page 5 of 39 Appendix A.2: Test Results of 6dB Bandwidth TestMode Antenna Channel DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 0.696 2401.680 2402.376 0.5 PASS 2440 0.672 2439.700 2440.372 0.5 PASS 2480 0.688 2479.676 2480.364 0.5 PASS BLE_2M Ant1 2402 1.120 2401.468 2402.588 0.5 PASS 2440 1.100 2439.476 2440.576 0.5 PASS 2480 1.140 2479.476 2480.616 0.5 PASS Prüfbericht - Produkte Test Report - Products Appendix A CN23LRWL 003 Page 6 of 39 BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Prüfbericht - Produkte Test Report - Products Appendix A CN23LRWL 003 Page 7 of 39 BLE_2M_Ant1_2402 BLE_2M_Ant1_2440 BLE_2M_Ant1_2480 Prüfbericht - Produkte Test Report - Products Appendix A CN23LRWL 003 Page 8 of 39 Appendix A.3: Test Results of 99% Bandwidth TestMode Antenna Channel OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 1.0629 2401.5065 2402.5694 --- PASS 2440 1.0675 2439.5059 2440.5734 --- PASS 2480 1.0598 2479.5107 2480.5705 --- PASS BLE_2M Ant1 2402 2.0628 2401.0198 2403.0826 --- PASS 2440 2.0756 2439.0092 2441.0848 --- PASS 2480 2.0656 2479.0196 2481.0852 --- PASS Prüfbericht - Produkte Test Report - Products Appendix A CN23LRWL 003 Page 9 of 39 BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Prüfbericht - Produkte Test Report - Products Appendix A CN23LRWL 003 Page 10 of 39 BLE_2M_Ant1_2402 BLE_2M_Ant1_2440 BLE_2M_Ant1_2480 Prüfbericht - Produkte Test Report - Products Appendix A CN23LRWL 003 Page 11 of 39 Appendix A.4: Test Results of Conducted Spurious Emissions Measured in 100 kHz Bandwidth Band Edge TestMode Antenna ChName Channel RefLevel[dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 Low 2402 3.84 -43.37 ≤-16.16 PASS High 2480 0.39 -41.17 ≤-19.61 PASS BLE_2M Ant1 Low 2402 3.89 -28.95 ≤-16.11 PASS High 2480 1.18 -44.98 ≤-18.82 PASS BLE_1M_Ant1_Low_2402 BLE_1M_Ant1_High_2480 Prüfbericht - Produkte Test Report - Products Appendix A CN23LRWL 003 Page 12 of 39 BLE_2M_Ant1_Low_2402 BLE_2M_Ant1_High_2480 Prüfbericht - Produkte Test Report - Products Appendix A CN23LRWL 003 Page 13 of 39 Conducted Spurious Emission TestMode Antenna Channel FreqRange [MHz] RefLevel [dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 2402 Reference 3.79 3.79 --- PASS 30~1000 3.79 -40.85 ≤-16.21 PASS 1000~26500 3.79 -32.36 ≤-16.21 PASS 2440 Reference 2.56 2.56 --- PASS 30~1000 2.56 -41.71 ≤-17.44 PASS 1000~26500 2.56 -32.35 ≤-17.44 PASS 2480 Reference 1.16 1.16 --- PASS 30~1000 1.16 -41.59 ≤-18.84 PASS 1000~26500 1.16 -32.05 ≤-18.84 PASS BLE_2M Ant1 2402 Reference 3.48 3.48 --- PASS 30~1000 3.48 -40.67 ≤-16.52 PASS 1000~26500 3.48 -32.49 ≤-16.52 PASS 2440 Reference 2.40 2.40 --- PASS 30~1000 2.40 -40.72 ≤-17.6 PASS 1000~26500 2.40 -32.05 ≤-17.6 PASS 2480 Reference 1.16 1.16 --- PASS 30~1000 1.16 -41.27 ≤-18.84 PASS 1000~26500 1.16 -32.19 ≤-18.84 PASS Prüfbericht - Produkte Test Report - Products Appendix A CN23LRWL 003 Page 14 of 39 BLE_1M_Ant1_2402_0~Reference BLE_1M_Ant1_2402_30~1000 BLE_1M_Ant1_2402_1000~26500 BLE_1M_Ant1_2440_0~Reference Prüfbericht - Produkte Test Report - Products Appendix A CN23LRWL 003 Page 15 of 39 BLE_1M_Ant1_2440_30~1000 BLE_1M_Ant1_2440_1000~26500 BLE_1M_Ant1_2480_0~Reference Prüfbericht - Produkte Test Report - Products Appendix A CN23LRWL 003 Page 16 of …
Text truncated - open the document above for the full version.
Prüfbericht - Produkte Test Report - Products Appendix B CN23LRWL 003 Page 1 of 3 Appendix B: Photographs of the Test Set-Up APPENDIX B: PHOTOGRAPHS OF THE TEST SET-UP ....................................................................................................... 1 PHOTOGRAPH 1: SET-UP PHOTO FOR RADIATED SPURIOUS EMISSION, BELOW 1GHZ ......................................................................... 2 PHOTOGRAPH 2: SET-UP PHOTO FOR RADIATED SPURIOUS EMISSION, ABOVE 1GHZ .......................................................................... 2 PHOTOGRAPH 3: SET-UP PHOTO FOR CONDUCTED EMISSION ON AC MAINS ..................................................................................... 3 Prüfbericht - Produkte Test Report - Products Appendix B CN23LRWL 003 Page 2 of 3 Photograph 1: Set-up photo for Radiated Spurious Emission, below 1GHz Photograph 2: Set-up photo for Radiated Spurious Emission, above 1GHz Prüfbericht - Produkte Test Report - Products Appendix B CN23LRWL 003 Page 3 of 3 Photograph 3: Set-up photo for Conducted Emission on AC Mains
Prince Plaza 2201-2206, 51 Taizi Road, Shuiwan · Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.70 mW |
2.4GHz Wi-Fi & BT IoT Module
Equipment Class
DTS - Digital Transmission System
Sous Vide
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzT1 Wireless
Equipment Class
DTS - Digital Transmission System