Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC Warning: An y Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including in terference that may cause undesired operation Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable p rotection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause h armful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. — Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. — Consult the dealer or an experienced radio/TV technician for help. Specific Absorption Rate (SAR) information- SAR tests are conducted using standard operating positions accepted by the FCC with the phone transmitting at its highest certified power level in all tested frequency bands, although the SAR is determined at the highest certified power level, the actual SAR level of the phone while operating can be well below the maximum value. Before a new model phone is a available for sale to the public, it must be tested and certified to the FCC that it does not exceed the exposure limit established by the FCC, tests for each phone are performed in p ositions and locations as required by the FCC. For body worn operation, this model phone has been tested and meets the FCC RF exposure guidelines when used with an accessory designated for this product or when used with an accessory that contains no metal and that positions the handset a minimum of 1mm fro m the body. Non-compliance with the above restrictions may result in violation of RF exposure guidelines
THREE STONES MEDIA LLC U.S. Agent Letter of Attestation To: Federal Communications Commission 7435 Oakland Mills Road, Columbia, MD 21046, USA Date: 8/25/2023 Ref: Attestation Statement – Part2.911(d)(7) filing FCC ID:2A7DX-BV6200 DOKE COMMUNICATION (HK) LIMITED (“the applicant”) certifies that, as of the date of the filing of the application, THREE STONES MEDIA LLC(“the agent”) is our designated U.S. agent for service of process for the abovereference FCC ID. The applicant accepts to maintain an agent for service of process in the United States forno less than one year after either the grantee has permanently terminated all marketing and importation of theapplicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicialproceeding involving the equipment, whichever is later. The applicant further acknowledges it is ourresponsibility to inform the FCC whenever the agent information changes. THREE STONES MEDIA LLC ("the agent) understand it is the agent's obligation to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address. Designated U.S. Agent Company Name: THREE STONES MEDIA LLC FRN: 0033401761 GC: 2A99E Address: 1200 Broadway St. APT 329, Los Angeles, CA90015 Signature: Contact Person: Sijie Zhang Tel: +1 267 909 3692 Email: [email protected] Applicant Company Name: DOKE COMMUNICATION (HK) LIMITED Address: RM 1902 EASEY COMM BLDG 253-261 HENNESSY ROAD WANCHAI HK CHINA Signature: Contact Person: Lynne Chen Tel: 18825230528 Email: [email protected]
(DOKE COMMUNICATION (HK) LIMITED) (2023.09.13) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2A7DX- BV6200) [DOKE COMMUNICATION (HK) LIMITED] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Lynne Chen) (DOKE COMMUNICATION (HK) LIMITED) (2023.09.13) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2A7DX-BV6200) [DOKE COMMUNICATION (HK) LIMITED] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Lynne Chen)
DOKE COMMUNICATION (HK) LIMITED Agent Authorization Letter (2023-09-13) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Shenzhen NTEK Testing Technology Co., Ltd. 1/F, Building E, Fenda Science Park Sanwei, Xixiang, Bao'an District, Shenzhen, Guangdong, China Alex.li [email protected] to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Lynne Chen / Manager Date/City: 2023-09-13 / HONG KONG Phone: 18825230528 Fax: 0755-6668278 E-mail: [email protected]
DOKE COMMUNICATION (HK) LIMITED Long Term Confidentiality Request Letter (2023-09-13) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR Product: Mobile Phone Model No.: BV6200 FCC ID: 2A7DX-BV6200 To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the Schematic Diagram Block Diagram Operational Description Software Security Requirements for UNII devices Tune up procedure Required to be submitted with this application be permanently withheld from public review. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Please contact me if there is any information you may need. Sincerely, Lynne Chen / Manager Date/City: 2023-09-13 / HONG KONG Phone: 18825230528 Fax: N/A E-mail: [email protected]
DOKE COMMUNICATION (HK) LIMITED Short Term Confidentiality Request Letter (2023-09-13) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Short Term Confidentiality Request For Product: Mobile Phone Model No.: BV6200 FCC ID: 2A7DX-BV6200 To Whom It May Concern: In accordance with sections 0.457 and 0.459 of CFR 47, <DOKE COMMUNICATION (HK) LIMITED>. requests short-term Confidentiality of following sections of this application for a period of 180 days after grant is issued. Test setup photos Internal photos External Photo User’s manual These documents contain detailed system and equipment descriptions and related information about the product, which <DOKE COMMUNICATION (HK) LIMITED> considers to be proprietary, confidential, and a custom design and otherwise, would not release to the general public. Since this design is a basis from which future technological products will evolve, <DOKE COMMUNICATION (HK) LIMITED> feels that this information would be of benefit to its competitors, and that the disclosure of the information in these documents would give our competitors an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Lynne Chen / Manager Date/City: 2023-09-13 / HONG KONG Phone: 18825230528 Fax: N/A E-mail: [email protected]
Photo 9 Photo 10 Photo 11 Photo 12 Photo 13 Photo 14 Photo 15 Photo 16 Photo 17 Photo 18 Photo 19 Photo 20 Photo 21 Photo 22 BT/WIFI ANT 4G DIV ANT Photo 23 2/3/4G Main ANT
Page 1 of 240 Report No.: S23081002902001 FCC SAR EVALUATION REPORT In accordance with the requirements of FCC 47 CFR Part 2(2.1093), ANSI/IEEE C95.1-1992 and IEEE Std 1528-2013 Product Name: Mobile Phone Brand Name: Blackview Model Name: BV6200 Family Model: N/A Report No.: S23081002902001 FCC ID: 2A7DX-BV6200 Prepared for DOKE COMMUNICATION (HK) LIMITED RM 1902 EASEY COMM BLDG 253-261 HENNESSY ROAD WANCHAI HK CHINA Prepared by Shenzhen NTEK Testing Technology Co., Ltd. 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street, Bao'an District, Shenzhen 518126 P.R.China. Tel. 400-800-6106, 0755-2320 0050, 0755-2320 0090 Website: http://www.ntek.org.cn Page 2 of 240 Report No.: S23081002902001 TEST RESULT CERTIFICATION Applicant’s name ................. : DOKE COMMUNICATION (HK) LIMITED Address .................................. : RM 1902 EASEY COMM BLDG 253-261 HENNESSY ROAD WANCHAI HK CHINA Manufacturer's Name .......... : Shenzhen DOKE Electronic Co., Ltd Address .................................. : 801, Building3, 7th Industrial Zone, Yulv Community, Yutang Road, Guangming District, Shenzhen, China. Product description Product name ........................ : Mobile Phone Brand Name ......................... : Blackview Model and/or type reference .............................. : BV6200 Family Model ......................... : N/A Standards ............................. : FCC 47 CFR Part 2(2.1093) ANSI/IEEE C95.1-1992 IEEE Std 1528-2013 Published RF exposure KDB procedures This device described above has been tested by Shenzhen NTEK. In accordance with the measurement methods and procedures specified in IEEE Std 1528-2013 and KDB 865664 D01. Testing has shown that this device is capable of compliance with localized specific absorption rate (SAR) specified in FCC 47 CFR Part 2(2.1093) and ANSI/IEEE C95.1-1992. The test results in this report apply only to the tested sample of the stated device/equipment. Other similar device/equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. This report shall not be reproduced except in full, without the written approval of Shenzhen NTEK, this document may be altered or revised by Shenzhen NTEK, personal only, and shall be noted in the revision of the document. Test Sample Number ............................. S230810029002 Date of Test Date (s) of performance of tests .............. : Aug. 14, 2023 ~ Aug. 24, 2023 Date of Issue ........................................... : Sep. 11, 2023 Test Result ............................................... : Pass Prepared By (Test Engineer) : (Jack Li) Approved By (Lab Manager) : (Alex Li) Page 3 of 240 Report No.: S23081002902001 ※ ※ Revision History ※ ※ REV. DESCRIPTION ISSUED DATE REMARK Rev.1.0 Initial Test Report Release Sep. 11, 2023 Jack Li Page 4 of 240 Report No.: S23081002902001 TABLE OF CONTENTS 1. General Information ............................................................................................ 6 1.1. RF exposure limits .................................................................................... 6 1.2. Statement of Compliance ........................................................................ 7 1.3. EUT Description ....................................................................................... 7 1.4. Test specification(s) .................................................................................. 9 1.5. Ambient Condition ................................................................................... 9 2. SAR Measurement System ................................................................................. 10 2.1. SATIMO SAR Measurement Set-up Diagram .......................................... 10 2.2. Robot ..................................................................................................... 11 2.3. E-Field Probe .......................................................................................... 12 2.3.1. E-Field Probe Calibration ................................................................. 12 2.4. SAM phantoms ...................................................................................... 13 2.4.1. Technical Data .................................................................................. 14 2.5. Device Holder ........................................................................................ 15 2.6. Test Equipment List ................................................................................ 16 3. SAR Measurement Procedures .......................................................................... 19 3.1. Power Reference ................................................................................... 19 3.2. Area scan & Zoom scan .......................................................................... 19 3.3. Description of interpolation/extrapolation scheme .............................. 21 3.4. Volumetric Scan ..................................................................................... 21 3.5. Power Drift ............................................................................................ 21 4. System Verification Procedure .......................................................................... 22 4.1. Tissue Verification ................................................................................. 22 4.1.1. Tissue Dielectric Parameter Check Results ...................................... 23 4.2. System Verification Procedure .............................................................. 24 4.2.1. System Verification Results .............................................................. 25 5. SAR Measurement variability and uncertainty .................................................. 26 5.1. SAR measurement variability ................................................................. 26 5.2. SAR measurement uncertainty .............................................................. 26 6. RF Expos…
Text truncated - open the document above for the full version.
Page 181 of 240 Report No.: S23081002902001 Page 182 of 240 Report No.: S23081002902001 Page 183 of 240 Report No.: S23081002902001 Page 184 of 240 Report No.: S23081002902001 Page 185 of 240 Report No.: S23081002902001 Page 186 of 240 Report No.: S23081002902001 Page 187 of 240 Report No.: S23081002902001 Page 188 of 240 Report No.: S23081002902001 Page 189 of 240 Report No.: S23081002902001 Page 190 of 240 Report No.: S23081002902001 Page 191 of 240 Report No.: S23081002902001 Page 192 of 240 Report No.: S23081002902001 Page 193 of 240 Report No.: S23081002902001 Page 194 of 240 Report No.: S23081002902001 Page 195 of 240 Report No.: S23081002902001 Page 196 of 240 Report No.: S23081002902001 Page 197 of 240 Report No.: S23081002902001 Page 198 of 240 Report No.: S23081002902001 Page 199 of 240 Report No.: S23081002902001 Page 200 of 240 Report No.: S23081002902001 Page 201 of 240 Report No.: S23081002902001 Page 202 of 240 Report No.: S23081002902001 Page 203 of 240 Report No.: S23081002902001 Page 204 of 240 Report No.: S23081002902001 Page 205 of 240 Report No.: S23081002902001 Page 206 of 240 Report No.: S23081002902001 Page 207 of 240 Report No.: S23081002902001 Page 208 of 240 Report No.: S23081002902001 Page 209 of 240 Report No.: S23081002902001 Page 210 of 240 Report No.: S23081002902001 Page 211 of 240 Report No.: S23081002902001 Page 212 of 240 Report No.: S23081002902001 Page 213 of 240 Report No.: S23081002902001 Page 214 of 240 Report No.: S23081002902001 Page 215 of 240 Report No.: S23081002902001 Page 216 of 240 Report No.: S23081002902001 Page 217 of 240 Report No.: S23081002902001 Page 218 of 240 Report No.: S23081002902001 Page 219 of 240 Report No.: S23081002902001 Page 220 of 240 Report No.: S23081002902001 Page 221 of 240 Report No.: S23081002902001 Page 222 of 240 Report No.: S23081002902001 Page 223 of 240 Report No.: S23081002902001 Page 224 of 240 Report No.: S23081002902001 Page 225 of 240 Report No.: S23081002902001 Page 226 of 240 Report No.: S23081002902001 Page 227 of 240 Report No.: S23081002902001 Page 228 of 240 Report No.: S23081002902001 Page 229 of 240 Report No.: S23081002902001 Page 230 of 240 Report No.: S23081002902001
Test report Shenzhen Xinbinuo Communication Co. , Ltd. The full text of this report shall not be reproduced without the written approval of Shenzhen Sinopinol Communications Co. , Ltd. Page1 Test report Applicant Shenzhen Xinbinuo Communication Co. , Ltd. ProductMulti-branch DK054 Issue Date 202311 August The equipment was tested according to the ANTI/IEEE Standard 149-2008. The results of the tests indicate that the equipment tested has proved to be in compliance with the requirements recorded in this report. Prepared by: Jiang Cheng Approved by: Wang Peng Shenzhen Xinbinuo Communication Co. , Ltd. 3rd floor, building 25, Feipeng Industrial Park, Pinghu Street, Longgang District, Shenzhen City Test report Shenzhen Xinbinuo Communication Co. , Ltd. The full text of this report shall not be reproduced without the written approval of Shenzhen Sinopinol Communications Co. , Ltd. Page2 1. Test Laboratory 1.1 Notes of the Test report This report shall not be reproduced in full or partial. The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. Measurement Uncertainties were not taken into account and are published for informational purposesonly. This report is written to support regulatory compliance of applicable standards stated above. 1.2 Test facility Wide-screen microwave anechoic chamber: the Test frequency range is 600 to 6GHZ. 1.3 Testing Location Company: Shenzhen Xinbinuo Communication Co. , Ltd. Address: 3F, 25 Feipeng Industrial Park, Longgang District Shenzhen, P.R. China Contact: Jiang Cheng Telephone: 18682131070 E-mail: [email protected] 1.4 Laboratory Environment Temperature Min.= 19°C, Max.=30°C Relative humidity Min.=40%,Max.=72% Shield effect 0.6-7GHz >100dB Ground resistance <0.5Ω Test report Shenzhen Xinbinuo Communication Co. , Ltd. The full text of this report shall not be reproduced without the written approval of Shenzhen Sinopinol Communications Co. , Ltd. Page3 2. General Description of Equipment under Test 2.1 Applicant and Manufacturer information Applicant Name Shenzhen Xinbinuo Communication Co. , Ltd. Applicant address 3F, 25 Feipeng Industrial Park, Longgang District Shenzhen, P.R. China Manufacturer Name Shenzhen Xinbinuo Communication Co. , Ltd. Manufacturer address 3F, 25 Feipeng Industrial Park, Longgang District Shenzhen, P.R. China 2.2 General information EUT Description Product Name DK054 Model BV6200 Version 20230720V01 Version Antenna Type PIFA antenna Antenna Manufacturer Shenzhen Xinbinuo Communication Co. , Ltd. Test Frequency 600MHz-6GHz 2.3 Applied Standards According to the specifications of the manufacturer, it must comply with the requirements of the following standards: Test Method: ANSI/IEEE Std 149-2008 3. Test Conditions 3.1 Test Configuration The method is used to measure the antenna 3D GAIN of EUT in OTA qualified anechoic chamber. Equipment Under Test (EUT) geometry centre vertical projection at the centre of platform, the distance from EUT to measurement antenna is 1m. 3.2 Test Measurement Spherical coordinate system Test report Shenzhen Xinbinuo Communication Co. , Ltd. The full text of this report shall not be reproduced without the written approval of Shenzhen Sinopinol Communications Co. , Ltd. Page4 Figure 1 Test coordinate system Note: Theta is from 0-360degree.Phi is from EUT and record the Date, the step of rotation is 30 degree. Test Setup 4. Test Results 4.1 Gain and Efficiency Test report Shenzhen Xinbinuo Communication Co. , Ltd. The full text of this report shall not be reproduced without the written approval of Shenzhen Sinopinol Communications Co. , Ltd. Page5 Model Test State Frequency (MHz) Efficiency (%) Gain (dBi) Frequency (MHz) Efficiency (%) Gain (dBi) Note Free Space 700 12.85 -5.14 1912 21.32 -1.75 710 16.7 -4.28 1932 22.92 -1.23 720 17.36 -4.09 1952 21.97 -1.37 730 16.15 -4.8 1972 17.82 -2.08 740 15.74 -4.97 1992 17.54 -1.96 750 13.74 -5.18 2013 16.58 -2.19 760 13.36 -5.22 2033 13.3 -3.04 770 11.74 -5.67 2053 12.54 -3 780 10.35 -5.93 2073 11.31 -3.49 790 9.73 -6.23 2093 10.04 -4.17 800 7.59 -7.38 2114 8.57 -4.47 810 9.58 -7.3 2134 7.56 -4.8 820 10.53 -6.65 2154 7.51 -4.73 830 11.14 -6.34 2174 8.39 -4.09 840 10.75 -6.4 2194 7.78 -4.22 850 10.98 -6.11 2215 8.83 -3.56 860 11.58 -5.68 2235 9.09 -3.48 870 11.39 -5.92 2255 7.09 -4.58 880 10.4 -5.99 2275 8.46 -4.12 890 9.18 -6.32 2295 8.18 -4.51 900 7.48 -6.77 2316 7.35 -5.56 910 6.39 -7.13 2336 9.79 -4.98 920 5.84 -7.4 2356 8.24 -6.01 930 5.66 -8.01 2437 11.38 -6.49 940 5.34 -8.61 2457 14.12 -5.11 950 4.84 -9.5 2477 15.95 -4.46 960 4.06 -10.81 2497 20.61 -3.29 1710 18.45 -0.83 2518 20.04 -3.19 1730 19.55 -0.89 2538 19.55 -3.23 1750 18.24 -1.46 2558 20.64 -2.89 1770 20.91 -0.91 2578 16.48 -3.93 1790 21.72 -0.96 2598 15.35 -3.67 1811 20.8 -1.21 2619 16.08 -3.18 1831 23.04 -1 2639 11.8 -4.95 1851 22.57 -1.59 2659 11.38 -4.98 1871 23.41 -1.7 2679 11.96 -4.5 1891 24.79 -1.37 2700 8.18 -6.67 Test report Shenzhen Xinbinuo Communication Co. , Ltd. The full text of this report shall not be reproduced without the written approval of Shenzhen Sinopinol Communications Co. , Ltd. Page6 Model Test State Frequency (MHz) Efficiency (%) Gain (dBi) Frequency (MHz) Efficiency (%) Gain (dBi) Note Free Space 1560 44.81 -0.35 5150 17.73 -2.73 1564 46.1 -0.19 5174 14.96 -3.08 1568 45.08 -0.2 5198 13.79 -2.74 1573 44.34 -0.26 5222 15.99 -2.21 1577 45.64 -0.17 5246 11.74 -3.32 1582 47.2 -0.05 5270 16.66 -1.56 1586 46.24 0.06 5294 12.99 -2.47 1591 45.35 -0.11 5318 17.18 -1.03 5343 17.73 -0.97 2400 28.55 0.39 5367 13.7 -2.06 2411 31.39 0.75 5391 21.55 -0.04 2422 32.58 0.86 5415 16.75 -1.03 2433 32.04 0.82 5439 24.38 0.89 2444 31.99 0.78 5463 21.44 0.41 2455 34.96 1.08 5487 18.55 -0.19 2466 36.09 1.08 5512 23.61 0.56 2477 37.23 1.11 5584 19.11 -0.05 2488 36.16 0.9 5608 20.32 -0.19 5632 20.33 0.21 5656 19.96 -0.4 5753 17.29 -1.36 5777 13.67 -3 5801 15.41 -2.43 5825 10.89 -3.57 5849 12.31 -3.28 Note: WIFI and BT sh…
Text truncated - open the document above for the full version.
Report No.: S23081002901001 Version.1.3 Page 1 of 95 RADIO TEST REPORT FCC ID: 2A7DX-BV6200 Product: Mobile Phone Trade Mark: Blackview Model No.: BV6200 Family Model: N/A Report No.: S23081002901001 Issue Date: Sep 01, 2023 Prepared for DOKE COMMUNICATION (HK) LIMITED RM 1902 EASEY COMM BLDG 253-261 HENNESSY ROAD WANCHAI HK CHINA Prepared by Shenzhen NTEK Testing Technology Co., Ltd. 1/F, Building E, Fenda Science Park, Sanwei Community,Xixiang StreetBao’an District, Shenzhen 518126 P.R. China Tel. 400-800-6106, 0755-2320 0050, 0755-2320 0090 Website: http://www.ntek.org.cn Report No.: S23081002901001 Version.1.3 Page 2 of 95 Table of Contents Page 1 TEST RESULT CERTIFICATION ...................................................................................................................... 3 2 SUMMARY OF TEST RESULTS ......................................................................................................................... 4 3 FACILITIES AND ACCREDITATIONS ............................................................................................................. 5 3.1 FACILITIES ..................................................................................................................................................... 5 3.2 LABORATORY ACCREDITATIONS AND LISTINGS ................................................................................. 5 3.3 MEASUREMENT UNCERTAINTY ............................................................................................................... 5 4 GENERAL DESCRIPTION OF EUT .................................................................................................................. 6 5 DESCRIPTION OF TEST MODES...................................................................................................................... 8 6 SETUP OF EQUIPMENT UNDER TEST ........................................................................................................... 9 6.1 BLOCK DIAGRAM CONFIGURATION OF TEST SYSTEM ....................................................................... 9 6.2 SUPPORT EQUIPMENT ............................................................................................................................... 10 6.3 EQUIPMENTS LIST FOR ALL TEST ITEMS .............................................................................................. 11 7 TEST REQUIREMENTS .................................................................................................................................... 13 7.1 CONDUCTED EMISSIONS TEST ............................................................................................................... 13 7.2 RADIATED SPURIOUS EMISSION ............................................................................................................ 16 7.3 NUMBER OF HOPPING CHANNEL ........................................................................................................... 25 7.4 HOPPING CHANNEL SEPARATION MEASUREMENT ........................................................................... 26 7.5 AVERAGE TIME OF OCCUPANCY (DWELL TIME)................................................................................. 27 7.6 20DB BANDWIDTH TEST ........................................................................................................................... 29 7.7 PEAK OUTPUT POWER .............................................................................................................................. 30 7.8 CONDUCTED BAND EDGE MEASUREMENT ......................................................................................... 31 7.9 SPURIOUS RF CONDUCTED EMISSION .................................................................................................. 32 7.10 ANTENNA APPLICATION .......................................................................................................................... 33 7.11 FREQUENCY HOPPING SYSTEM (FHSS) EQUIPMENT REQUIREMENTS.......................................... 34 8 TEST RESULTS ................................................................................................................................................... 35 8.1 DWELL TIME ................................................................................................................................................... 35 8.2 MAXIMUM CONDUCTED OUTPUT POWER ....................................................................................................... 45 8.3 -20DB BANDWIDTH......................................................................................................................................... 51 8.4 OCCUPIED CHANNEL BANDWIDTH .................................................................................................................. 57 8.5 CARRIER FREQUENCIES SEPARATION .............................................................................................................. 63 8.6 NUMBER OF HOPPING CHANNEL ..................................................................................................................... 69 8.7 BAND EDGE .................................................................................................................................................... 72 8.8 BAND EDGE(HOPPING) ................................................................................................................................... 79 8.9 CONDUCTED RF SPURIOUS EMISSION ............................................................................................................. 86 Report No.: S23081002901001 Version.1.3 Page 3 of 95 1 TEST RESULT CERTIFICATION Applicant’s name ........................ : DOKE COMMUNICATION (HK) LIMITED Address ....................................... : RM 1902 EASEY COMM BLDG 253-261 HENNESSY ROAD WANCHAI HK CHINA Manufacturer's Name ................. : Shenzhen DOKE Electronic Co., Ltd Address ....................................... : 801, Buil…
Text truncated - open the document above for the full version.
Radiated Measurement Photos Conducted Measurement Photos
Test Positions Left Cheek Left Tilt 15 Degree Right Cheek Right Tilt 15 Degree Front Side (Separation distance of 10mm) Back Side (Separation distance of 10mm) Left Side (Separation distance of 10mm) Right Side (Separation distance of 10mm) Top Side (Separation distance of 10mm) Bottom Side (Separation distance of 10mm) END
1/F, Building E, Fenda Science Park Sanwei, · Shenzhen, Guangdong · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 7.93 mW |

Mobile Phone
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Bluetooth Speaker
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterBluetooth Speaker
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Mini PC
Equipment Class
DTS - Digital Transmission System
Smart phone
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter