Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
RF output power Bluetooth: BT: 3.37 dBm BLE: 2.56 dBm 2.4G WLAN: 13.99dBm 5.2G WLAN: 12.79dBm 5.8G WLAN: 10.53dBm NFC: -25.79 dBuA/m @10m GSM 900: 34.18 dBm, GSM 1800: 29.98 dBm WCDMA Band1: 23.66 dBm, WCDMA Band8: 23.88 dBm LTE: LTE Band 1: 23.45dBm, LTE Band 3: 23.24dBm, LTE Band 7: 24.71dBm, LTE Band 8: 23.91dBm, LTE Band 20: 24.36dBm, LTE Band 28: 23.66dBm
SAR REFERENCE DIPOLE CALIBRATION REPORT 2450 52.4 24 2600 55.3 24.6 3000 63.8 25.7 3500 67.1 25 7.3 BODY LIQUID MEASUREMENT Frequency MHz Relative permittivity ( r ’) Conductivity (σ) S/m requiredmeasuredrequiredmeasured 750 55.5 ±5 % PASS 0.96 ±5 % PASS 835 55.2 ±5 % 0.97 ±5 % 900 55.0 ±5 % 1.05 ±5 % 915 55.0 ±5 % 1.06 ±5 % 1450 54.0 ±5 % 1.30 ±5 % 1610 53.8 ±5 % 1.40 ±5 % 1800 53.3 ±5 % 1.52 ±5 % 1900 53.3 ±5 % 1.52 ±5 % 2000 53.3 ±5 % 1.52 ±5 % 2100 53.2 ±5 % 1.62 ±5 % 2450 52.7 ±5 % 1.95 ±5 % 2600 52.5 ±5 % 2.16 ±5 % 3000 52.0 ±5 % 2.73 ±5 % 3500 51.3 ±5 % 3.31 ±5 % 5200 49.0 ±10 % 5.30 ±10 % 5300 48.9 ±10 % 5.42 ±10 % 5400 48.7 ±10 % 5.53 ±10 % Page: 9/11 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Dipole vH Ref: ACR.262.4.2.MVGB.A 3 SAR REFERENCE DIPOLE CALIBRATION REPORT 5500 48.6 ±10 % 5.65 ±10 % 5600 48.5 ±10 % 5.77 ±10 % 5800 48.2 ±10 % 6.00 ±10 % 7.4 SAR MEASUREMENT RESULT WITH BODY LIQUID Software OPENSAR V4 Phantom SN 20/09 SAM71 Probe SN 18/11 EPG122 Liquid Body Liquid Values: eps’ : 56.6 sigma : 0.99 Distance between dipole center and liquid 15.0 mm Area scan resolution dx=8mm/dy=8mm Zoon Scan Resolution dx=8mm/dy=8m/dz=5mm Frequency 750 MHz Input power 20 dBm Liquid Temperature 21 °C Lab Temperature 21 °C Lab Humidity 45 % Frequency MHz 1 g SAR (W/kg/W) 10 g SAR (W/kg/W) measured measured 750 8.82 (0.88) 5.74 (0.57) Page: 10/11 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Dipole vH Ref: ACR.262.4.2.MVGB.A 3 SAR REFERENCE DIPOLE CALIBRATION REPORT 8 LIST OF EQUIPMENT Page: 11/11 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Equipment Summary Sheet Equipment Description Manufacturer / Model Identification No. Current Calibration Date Next Calibration Date Phantom MVG SN-20/09-SAM71 Validated. No cal required. Validated. No cal required. COMOSAR Test Bench Version 3 NA Validated. No cal required. Validated. No cal required. Network Analyzer Rhode & Schwarz ZVA SN100132 02/202 Calipers Carrera CALIPER-01 01/2023 01/202 Reference Probe MVG EPG122 SN 18/11 10/ 10/202 Signal Generator Agilent E4438C MY49070581 Amplifier Aethercomm SN 046 Characterized prior to test. No cal required. Characterized prior to test. No cal required. Power Meter HP E4418A US38261498 Power Sensor HP ECP-E26A US37181460 Directional Coupler Narda 4216-20 01386 Characterized prior to test. No cal required. Characterized prior to test. No cal required. Temperature and Humidity Sensor Control Company 15098832 11 SAM Multimeter Keithley 2000 1188656 /2023 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Dipole vH Ref: ACR.262.4.2.MVGB.A 3 02/2022 5 6 2022 3 01/2023 01/202 6 01/2023 01/202 6 01/2023 01/202 6 01/2023 01/202 6 11 /2020 ! "#$ " #% &'%()* $+$ ',-./01 2 34/5 4 0 6789 $#'$$'