Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Ningbo Fulman Communication Technology Co., Ltd 2025-12-02 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2A7Z4-FKQ) [Ningbo Fulman Communication Technology Co., Ltd] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, Lingyun Shen General manager Ningbo Fulman Communication Technology Co., Ltd No.98, Yuanzhong Road, Economic Development Zone, Xiang shan County, Zhejiang, China Ningbo Fulman Communication Technology Co., Ltd 2025-12-02 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2A7Z4-FKQ) [Ningbo Fulman Communication Technology Co., Ltd] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Lingyun Shen General manager Ningbo Fulman Communication Technology Co., Ltd No.98, Yuanzhong Road, Economic Development Zone, Xiang shan County, Zhejiang, China
Attestation Statements (2025-12-02) TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA RE: Attestation Statements Part 2.911(d)(7) request for (FCC ID: 2A7Z4-FKQ) (Ningbo Fulman Communication Technology Co., Ltd), the undersigned, hereby authorize (VENTION Tech Inc) to act as our designated U.S. agent for service of process,( Ningbo Fulman Communication Technology Co., Ltd) accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. (VENTION Tech Inc) accepts the responsibility to act as designated U.S. agent for service of process. Applicant Information : Company name: Ningbo Fulman Communication Technology Co., Ltd Contact Name: Lingyun Shen Address: No.98, Yuanzhong Road, Economic Development Zone, Xiang shan County, Zhejiang, China FRN: 0032681140 Telephone No: 0574-88121853 Email: [email protected] Signature [Lingyun Shen] U.S. Agent Information: Company Name: VENTION Tech Inc Address: 100 NHOWARD ST STE R,SPOKANE, WA,99201,UNITED STATES FRN: 0033631284 Contact Name: SONGZHI HUANG Telephone No: 626-361-3045 Email: [email protected] Signature [SONGZHI HUANG]
Ningbo Fulman Communication Technology Co., Ltd Declaration on model difference We the undersigned hereby confirm that these models are identical, and all models have the same RF module and antenna, PCB layout, schematics and component. Only the models name and product appearance color are different. Product name Trademark FCC ID Model no. Power Bank VENTION 2A7Z4-FKQ FKQ, FKQH0, FKQH0-TY, FKQN0, FKQN0-TY, FKQO0, FKQO0-TY Sincerely, Lingyun Shen General manager Ningbo Fulman Communication Technology Co., Ltd No.98, Yuanzhong Road, Economic Development Zone, Xiang shan County, Zhejiang, China
Ningbo Fulman Communication Technology Co., Ltd 2025-12-02 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Guangdong Global Testing Technology Co., Ltd. to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Lingyun Shen General manager Ningbo Fulman Communication Technology Co., Ltd No.98, Yuanzhong Road, Economic Development Zone, Xiang shan County, Zhejiang, China
Ningbo Fulman Communication Technology Co., Ltd 2025-12-02 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR (EUT Name: Power Bank /Model: FKQ, FKQH0, FKQH0-TY, FKQN0, FKQN0-TY, FKQO0, FKQO0-TY/FCC ID: 2A7Z4- FKQ) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the (Block Diagram, Operational Description, Schematics) required to be submitted with this application be permanently withheld from public review. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Please contact me if there is any information you may need. Sincerely, Lingyun Shen General manager Ningbo Fulman Communication Technology Co., Ltd No.98, Yuanzhong Road, Economic Development Zone, Xiang shan County, Zhejiang, China
External Photographs View of EUT-1 View of EUT-2 Page 2 of 4 View of EUT-3 View of EUT-4 Page 3 of 4 View of EUT-5 View of EUT-6 Page 4 of 4 View of EUT-7
视图 关键尺寸 技术要求 1. 表面无披风 / 毛刺等不良 2. 保证带公差和带 *尺寸 \ P 3. 未标公差按: GB/T14486-2008} 公差表 4. 未标尺寸按3D,未标圆 / 倒角为 R 0.25 / C 0.25 5. 所有材质都要能通过环保认证 修改标识 版本 变更内容 变更日期 变更担当 机种 1/1 MM 页数 单位 核准 审核 材质 比例 表面处理 子件编号 子件名称 制图 ±0.80 ±0.50 >400-1000>120-400 ±2 ±1° >30-120 ±0.30±0.20 ±1 >6-30 ±2° ±0.10 ±0.25 >0.5-6 线性 C角/R角 角度 公差范围 宁波福茂通讯科技有限公司 公差表 GB/T1804-2000 级别 M 1:1 FKQ 带线 充电宝 中文版 塑料 邹春详 FKQ 彭龙 V00 首次发行 2025-10-10 V01 修改参数 2025-10-13 V02 修改文案 2025-10-14 V02 改接口文案 2025-11-11 15.00 mm 居中 对接口居中 0.50 mm 对接口居中 0.50 mm 0.50 mm 6.00 mm 居中 3.50 mm ANTONE Warm Gray 3 C 30.00 mm 3.16 mm 54.00 mm 88.49 mm 米色壳:字符丝印: PANTONEWarm Gray 7C 标识内容:橙壳 米色壳:字符丝印: PANTONE 474C 30.00 mm 3.16 mm 54.00 mm 88.49 mm 橙色壳:字符丝印: PANTONE7578C SN: VXXXGNXX SN: VXXXGNXXSN: VXXXGNXX 7.55 mm 42.11 mm 7.55 mm 42.11 mm
Internal Photographs Internal View of EUT-1 Internal View of EUT-2 Page 2 of 3 Internal View of EUT-3 Internal View of EUT-4 Page 3 of 3 Internal View of EUT-5 Internal View of EUT-6
RF EXPOSURE EVALUATION EUT Specification FCC ID: 2A7Z4-FKQ Characteristics Description Product Name Power Bank Model number FKQ Series Model FKQH0, FKQH0-TY, FKQN0, FKQN0-TY, FKQO0, FKQO0-TY Model difference The difference of the models are model name and product appearance color, others are the same. Power Supply AC 120V/60Hz DC 5V/9V/12V Battery 3.85V Operating Frequency Range 110-205KHz for phone charging Modulation Technique ASK Antenna Type Coil Antenna Device category Portable (<20cm separation) Mobile (>20cm separation) Others ___ Antenna diversity Single antenna Multiple antennas Tx diversity Rx diversity Tx/Rx diversity Evaluation applied MPE Evaluation SAR Evaluation Applicable Standard: FCC Part 1(1.1310), Part 2(2.1093) and KDB 680106 D01 Wireless Power Transfer v04 Page 2 of 9 Applicable Requirement: Three different categories of transmitters are defined by the FCC in OET Bulletin 65. These categories are fixed installation, mobile, and portable and are defined as follows: Fixed Installations: fixed location means that the device, including its antenna, is physically secured at a permanent location and is not able to be easily moved to another location. Additionally, distance to humans from the antenna is maintained to at least 2 meters. Mobile Devices: a mobile device is defined as a transmitting device designed to be used in other than fixed locations and to be generally used in such a way that a separation distance of at least 20 centimeters is normally maintained between the transmitter's radiating structures and the body of the user or nearby persons. Transmitters designed to be used by consumers or workers that can be easily re-located, such as a wireless modem operating in a laptop computer, are considered mobile devices if they meet the 20 centimeter separation requirement. The FCC rules for evaluating mobile devices for RF compliance are found in 47 CFR ß2.1091. Portable Devices: a portable device is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. Portable device requirements are found in Section 2.1093 of the FCC's Rules (47 CFRß2.1093). The FCC also categorizes the use of the device as based upon the user’s awareness and ability to exercise control over his or her exposure. The two categories defined are Occupational/ Controlled Exposure and General Population/Uncontrolled Exposure. These two categories are defined as follows: Occupational/controlled exposure limits apply in situations in which persons are exposed as a consequence of their employment provided those persons are fully aware of the potential for exposure and can exercise control over their exposure. Limits for occupational/controlled exposure also apply in situations when a person is transient through a location where occupational/controlled limits apply provided he or she is made aware of the potential for exposure. The phrase fully aware in the context of applying these exposure limits means that an exposed person has received written and/or verbal information fully explaining the potential for RF exposure resulting from his or her employment. With the exception oftransient persons, this phrase also means that an exposed person has received appropriate training regarding work practices relating to controlling or mitigating his or her exposure. Such training is not required for transient persons, but they must receive written and/or verbal information and notification (for example, using signs) concerning their exposure potential and appropriate means available to mitigate their exposure. The phrase exercise control means that an exposed person is allowed to and knows how to reduce or avoid exposure by administrative or engineering controls and work practices, such as use of personal protective equipment or time averaging of exposure. Page 3 of 9 General population/uncontrolled exposure limits apply in situations in which the general public may be exposed, or in which persons who are exposed as a consequence of their employment may not be fully aware of the potential for exposure or cannot exercise control over their exposure. Licensees and applicants are responsible for compliance with both the occupational/controlled exposure limits and the general population/uncontrolled exposure limits as they apply to transmitters under their jurisdiction. Licensees and applicants should be aware that the occupational/controlled exposure limits apply especially in situations where workers may have access to areas in very close proximity to antennas and access to the general public may be restricted. In lieu of evaluation with the general population/uncontrolled exposure limits, amateur licensees authorized under part 97 of this chapter and members of his or her immediate household may be evaluated with respect to the occupational/controlled exposure limits in this section, provided appropriate training and information has been provided to the amateur licensee and members of his/her household. Other nearby persons who are not members of the amateur licensee's household must be evaluated with respect to the general population/uncontrolled exposure limits. Test Setup Block Page 4 of 9 Test Procedure 1.Connect the EUT and equipment as above diagram of test configuration. 2.EUT was placed on a table, and the measure probe was placed at a measurement distance of 20cm from the EUT to the center of the probe. 3.Power on the measuring probe, the EUT was set at the maximum field strength emission state. 4.The EUT was put in different directions (Left, Right, Front, Rear, Top and Bottom) toward to the measure probe. The distance from the top of the EUT to the probe is 20cm, and the distance from other directions is 20cm.Measure the value of field strength. 5.Record the worst data of the different directions. Measuring Device and Test Equipment Used Equipment Manufacturer Model No. Serial No. Last Cal. Due Date E&H…
Text truncated - open the document above for the full version.
FY-GZ001 1 SPECIFICATION FOR APPROVAL Acceptance status Trial production Trial production Supplier name Shenzhen Taoruan Electronics Co., Ltd. Product model A11 magnetic coil Code Assembly plant code name of material A11 single coil Specification Description A11 magnetic coil, 6.3uH±10% magnet diameter 43.5mm double groove thickness 0.8mm center hole diameter 5.0mm coil inner diameter 20.5mm outer diameter 40mm Hot air wire 0.08×24×2P 10TS total coil thickness <1.7mm 50mm coil length 3mm lead-in tin immersion back-coated adhesive ROHS certified Acknowledgement Version Environmental requirements ROHS Date of acceptance 2023/08/20 Supplier address Room 701, Building 10, Zone B, Wulian Team Industrial Park, Shangcun Community, Gongming Sub-district, Guangming District, Shenzhen City Supplier phone/ fax number 13824883512 Supplier email/website [email protected] Approved by RD/Engineering Department Business Sales Quality ratify engineering recognition ratify Quality purchase address : telephone : Website: Supplier signature Customer signature FY-GZ001 2 Page 2 of4 Page 1of 16 Fine Version Change History Version Change History Version Rev. Before Change After Change Change Date Ratify Approved By A.0 new issue ---- 2023/08/20 Qian Limou FY-GZ001 3 Fine Page 3 of4 Product type: DESC 20.5x40-10Ts-0.08*24*2P-50mm Version Rev:A 0 C u s to me r C U S T: Fine P/N: Customer part number CUST P/N: 1 . D i m e n s i o n s ( m m ) : 2 . S c h e m a t i c D i a g r a m : 3 . W i n d i n g S p e c i f i c a t i o n s : A 40.0±1 B 20.5±0.5 C 0.8+/-0.1 D1 52±2 D2 50±2 E 3mm±1.5 F 43.5±0.5 G 11.0 ref H 1.5±0.2 Max I 5.0 ref Notice: 1. Coil with magnet attached, magnet size 43.5±0.5mm, inner hole 5.0 mm, thickness 0.8+/-0.1 mm, single groove 2. Wrap high -temperature adhesive tape (width: 8mm ± 0.5mm) around the coil's lead -out position. 3. Attach ordinary double - sided tape (circular, diameter: 38mm (ref), inner hole: 7.0mm (re f)) with a tear tab to the back of the magnet NO. TERMINAL r WIRE Turns Winding Direction 1 S F Hot Air Line 0.08*24*2P 10Ts CCW 4 . E l e c t r i c a l C h a r a c t e r i s t i c s : Temperature: 2 5 ± 10 ° C, RELATIVE HUMIDITY: 6 5 ± 20% NO. ITEM TERMINAL Standard SPECIFICATION TEST FREQUENCY TEST EQUIPMENTS 1 IND. S-F 3.8 uH ± 20% single coil 100KHz/ 1.0V LC Z ME TER 1 0 62 B 2 IND. S-F 6.5 uH ± 10% with magnet 100KHz/ 1.0V LC Z ME TER 1 0 62 B 3 Q Factor S-F ≤60 (ref) Magnet 100KHz/ 1.0V LC Z ME TER 1 0 62 B 4 DCR S-F ≤70m Ω L C Z M E T E R 5 0 2 B PREPARED BY/ DATE CHECKED BY/DATE Feng Boqun 2023/08/20 Su Yanping 2023/08/20 FY-GZ001 4 Fine Page4 of4 Product type: DESC 20.5x40-10Ts-0.08*24*2P-50mm-CLB Version R ev:A 0 Custo me r CUS T: Fine P/N: Customer part number CUST P/N: 5 . P a c k a g i n g : P A C K O N G : 5.1 Packing pictures: 5 . 2 P a c k i n g Q u a n t i t y a n d S p e c i f i c a t i o n s Item Quantity Material Specifications Box 350 Pcs 370*265*55mm Big Carton 1400 Pcs 390*270*245mm 5.3 . The packaging shall be based on the existing packing plate and the actual delivery package shall prevail. If there is any requirement, we can customize it. V I . M a t e r i a l L i s t : number Material name Description Manufacturer 1 hot air line Hot Air Enamel Wire 0.08*24*2P D o n g g u a n J i n j i e yu a n E l e c t r o n i c M a t e r i a l s C o . , L t d . 2 lead-free solder lead-free solder S h e n z h e n D a o q i n T i n I n d u s t r y C o . , L t d . 3 magnetic sheet Φ43.5*5.0*0.8 mm Manganese-zinc hard magnetic sheet G u a n g z h o u R u i j i n g N e w M a t e r i a l s T e c h n o l o g y C o . , L t d . 4 glue 201 glue D o n g g u a n F e i q u a n E l e c t r o n i c M a t e r i a l s C o . , L t d . 5 high temperature adhesive tape 8 mm wide high temperature adhesive tape D o n g g u a n Z h i x i n g T a p e N e w M a t e r i a l s C o . , L t d . 6 Double-sided tape with holes H a n d - st ri p p ed r ou n d , 3 8 m m d i a m e t e r ( r e f ) , a d h e s i v e - b a c k ed S h e n z h e n H o n g w e i d a T e c h n o l o g y C o . , L t d . PREPARED BY/ DATE CHECKED BY/DATE Feng Boqun 2023/08/20 Su Yanping 2023/08/20
TRF No.: 04-E001-0B TRF Originator: GTG TRF Date: 2023-12-13 Web: www.gtggroup.com E-mail: [email protected] Tel.: 86-400 755 8988 CFR 47 FCC PART 15 SUBPART C TEST REPORT For Power Bank MODEL NUMBER: FKQ, FKQH0, FKQH0-TY, FKQN0, FKQN0-TY, FKQO0, FKQO0-TY REPORT NUMBER: E04A25100822F00701 ISSUE DATE: December 1, 2025 FCC ID: 2A7Z4-FKQ Prepared for Ningbo Fulman Communication Technology Co., Ltd No.98, Yuanzhong Road, Economic Development Zone, Xiang shan County, Zhejiang, China Prepared by Guangdong Global Testing Technology Co., Ltd. Room 101-105, 203-210, Building 1, No.2, Keji 8 Road, Songshan Lake Park, Dongguan city, Guangdong, People’s Republic of China, 523808 This report is based on a single evaluation of the submitted sample(s) of the above mentioned Product, it does not imply an assessment of the production of the products. This report shall not be reproduced, except in full, without the written approval ofGuangdong Global Testing Technology Co., Ltd. REPORT NO.: E04A25100822F00701 Page 2 of 27 TRF No.: 04-E001-0B Global Testing , Great Quality. Revision History Rev. Issue Date Revisions Revised By V0 December 1, 2025 Initial Issue REPORT NO.: E04A25100822F00701 Page 3 of 27 TRF No.: 04-E001-0B Global Testing , Great Quality. Summary of Test Results Test Item Limit/Requirement Result Antenna Requirement FCC Part 15.203 Pass AC Power Line Conducted Emission FCC Part 15.207 Pass 20dB Bandwidth FCC Part 15.215 Pass Radiated Emission FCC Part 15.205/15.209 Pass Note: 1. N/A: In this whole report not applicable. *This test report is only published to and used by the applicant, and it is not for evidence purpose in China. *The measurement result for the sample received is <Pass> according to <CFR 47 FCC PART 15 SUBPART C> when <Accuracy Method> decision rule is applied. REPORT NO.: E04A25100822F00701 Page 4 of 27 TRF No.: 04-E001-0B Global Testing , Great Quality. CONTENTS 1. ATTESTATION OF TEST RESULTS ..................................................................................... 5 2. TEST METHODOLOGY ......................................................................................................... 6 3. FACILITIES AND ACCREDITATION ..................................................................................... 6 4. CALIBRATION AND UNCERTAINTY ................................................................................... 7 4.1. MEASURING INSTRUMENT CALIBRATION ........................................................... 7 4.2. MEASUREMENT UNCERTAINTY ............................................................................ 7 5. EQUIPMENT UNDER TEST .................................................................................................. 8 5.1. DESCRIPTION OF EUT ........................................................................................... 8 5.2. TEST MODE ............................................................................................................. 8 5.3. SUPPORT UNITS FOR SYSTEM TEST ................................................................... 9 5.4. SETUP DIAGRAM .................................................................................................... 9 6. MEASURING EQUIPMENT AND SOFTWARE USED......................................................... 10 7. RADIATED TEST RESULTS ............................................................................................... 11 7.1. Radiated Spurious Emission ................................................................................... 15 8. AC POWER LINE CONDUCTED EMISSION ...................................................................... 21 9. 20DB BANDWIDTH ............................................................................................................. 24 10. ANTENNA REQUIREMENT ................................................................................... 27 REPORT NO.: E04A25100822F00701 Page 5 of 27 TRF No.: 04-E001-0B Global Testing , Great Quality. 1. ATTESTATION OF TEST RESULTS Applicant Information Company Name: Ningbo Fulman Communication Technology Co., Ltd Address: No.98, Yuanzhong Road, Economic Development Zone, Xiang shan County, Zhejiang, China Manufacturer Information Company Name: Dongguan Ganner Electronic Technology Co., Ltd Address: 199 Yuanshanbei Avenue, Changping Town, Dongguan City, Guangdong Province.China. EUT Information Product Description: Power Bank Model: FKQ Series Model: FKQH0, FKQH0-TY, FKQN0, FKQN0-TY, FKQO0, FKQO0-TY Brand: VENTION Sample Received Date: November 3, 2025 Sample Status: Normal Sample ID: A25100822 001 Date of Tested: November 3, 2025 to November 21, 2025 APPLICABLE STANDARDS STANDARD TEST RESULTS CFR 47 FCC PART 15 SUBPART C Pass Prepared By: Checked By: Jok Yang Alan He Project Engineer Laboratory Leader Approved By: Shawn Wen Laboratory Manager REPORT NO.: E04A25100822F00701 Page 6 of 27 TRF No.: 04-E001-0B Global Testing , Great Quality. 2. TEST METHODOLOGY All tests were performed in accordance with the standard CFR 47 FCC PART 15 SUBPART C 3. FACILITIES AND ACCREDITATION Accreditation Certificate A2LA (Certificate No.: 6947.01) Guangdong Global Testing Technology Co., Ltd. has been assessed and proved to be in compliance with A2LA. FCC (FCC Designation No.: CN1343) Guangdong Global Testing Technology Co., Ltd. has been recognized to perform compliance testing on equipment subject to Supplier's Declaration of Conformity (SDoC) and Certification rules ISED (Company No.: 30714) Guangdong Global Testing Technology Co., Ltd. has been registered and fully described in a report filed with ISED. The Company Number is 30714 and the test lab Conformity Assessment Body Identifier (CABID) is CN0148. Note: All tests measurement facilities use to collect the measurement data are located at Room 101-105, 203-210, Building 1, No.2, Keji 8 Road, Songshan Lake Park, Dongguan city, Guangdong, People’s Republic of China, 523808 REPORT NO.: E04A25100822F00701 Page 7 of 27 TRF No.: 04-E001-0…
Text truncated - open the document above for the full version.
Radiated Spurious Emission AC Power Line Conducted Emission RF Exposure Evaluation
Room 101-105,203-210, Building 1, No.2, Keji 8 Roa · Dongguan, 523808 · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.11 MHz - 0.205 MHz | - |

Selfie Monitor Screen
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Wireless HDMI Video Transmitter and Receiver
Equipment Class
NII - Unlicensed National Information Infrastructure TX
10000mAh Power Bank
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Wireless CarPlay Adapter
Equipment Class
NII - Unlicensed National Information Infrastructure TX
10000mAh Power Bank
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz