FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Zhejiang General Light Curtain Co.,LTD./
  3. 2A839-PEM102

2A839-PEM102Remote Control

Zhejiang General Light Curtain Co.,LTD.
Remote Control - FCC ID 2A839-PEM102 - Zhejiang General Light Curtain Co.,LTD.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Dec 06, 2022
Application Purpose
Original Equipment
Date of Application
Dec 06, 2022
Equipment Note
Remote Control
Frequency Range
433.92000000 - 433.92000000
Company
Zhejiang General Light Curtain Co.,LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

P button Up Stop Down Product introduction Technical data • Power : 3V (CR2032) • Frequency : 433.92MHz • Working current : ≤ 20MA • Operating temperature : - 20 °C~+60 °C • Distance : ≥ 100m (open space) -20°C 60°C Working temperature Warning PEM 102 Remote Control Manual Bracket • The remote contorl shall not be affected by moisture or impact, so as to avoid affecting its life. • In the process of use, when you find that the remote control distance is obviously close or not sensitive, please check whether the battery needs to be replaced. • Press any button for more than 10 seconds, and the transmitter will stop sending wireless ignals. • Please properly dispose of the used battery according to the instructions. FCC STATEMENT: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limitsfor a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation . If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. The user that changes or modifications not expressly approved by the party responsible for compliance could void the user`s authority to operate the equipment.

External Photos

Page 1 of 4 ReportNo.:SHATBL2210013 ShanghaiATBLTechnologyCo.,Ltd. PHOTOGRAPHSOFTHEEUTEXTERNALCONSTRUCTIONALDETAILS Photo1 Photo2 Page 2 of 4 ReportNo.:SHATBL2210013 ShanghaiATBLTechnologyCo.,Ltd. Photo3 Photo4 Page 3 of 4 ReportNo.:SHATBL2210013 ShanghaiATBLTechnologyCo.,Ltd. Photo5 Photo6 Page 4 of 4 ReportNo.:SHATBL2210013 ShanghaiATBLTechnologyCo.,Ltd. Photo7

ID Label/Location Info

PEM10 2 Battery: 3V(CR2032) Channel FCC ID :2A839-PEM102 Double

Test Report

"ShanghaiATBLTechnologyCo.,Ltd."herebycertifiesthataccordingtoactualtestingconditions.Thetestresultsorobservationsare providedinaccordancewithmeasuredvalue,withouttakingriskscausedbyuncertaintyintoaccount.Withoutexplicitstipulationinspecial agreements,standardsorregulations,ATBLshallnotassumeanyresponsibility.Thetestresultsorobservationsareapplicableonlytotested sample.Clientshallberesponsibleforrepresentativenessofthesampleandauthenticityofthematerial.Thisreportwillbevoidwithout authorizedsignatureorspecialsealfortestingreport.Donotcopiedwithoutauthorization. Tel:+86(0)21-51298625Web:www.atbl-lab.comEmail:[email protected] ReportNo.:SHATBL2210013W01 Applicant: ZhejiangGeneralLightCurtainCo.,LTD. Address: XinTangTouVillage,XinJieTown,XiaoShanDistrict, HangZhouCity,ZheJiangProvince,China ProductName:RemoteControl BrandName: ModelName:PEM102 SeriesModel:N/A FCCID:2A839-PEM102 TestStandard:FCCPart15.231 RADIOTESTREPORT Page2of31 ReportNo.:SHATBL2210013W01 ShanghaiATBLTechnologyCo.,Ltd.Number:SHATBL-W-05Releasedate:2022-03-01VersionNo.A/1 GENERALDESCRIPTION Applicant’sName....................: ZhejiangGeneralLightCurtainCo.,LTD. Address......................................: XinTangTouVillage,XinJieTown,XiaoShanDistrict, HangZhouCity,ZheJiangProvince,China Manufacture'sName .............. : ZhejiangGeneralLightCurtainCo.,LTD. Address ...................................... : XinTangTouVillage,XinJieTown,XiaoShanDistrict, HangZhouCity,ZheJiangProvince,China ProductDescription ProductName ........................... : RemoteControl BrandName ............................... : ModelName .............................. : PEM102 SeriesModel...............................: N/A TestStandards........................: FCCPart15.231 TestProcedure .......................... : ANSIC63.10-2013 ThisdevicedescribedabovehasbeentestedbyATBL,thetestresultsshowthattheequipmentunder test(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlytothetestedsample identifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofATBL,thisdocument maybealteredorrevisedbyATBL,personalonly,andshallbenotedintherevisionofthedocument. Dateofreceiptoftestitem ........................ : 2022.10.18 Date(s)ofperformanceoftests...............: 2022.11.23-2022.11.24 DateofIssue..............................................: 2022.11.23 TestResult..................................................:Pass TestingEngineer: (ChrisXu/JackSuo) TechnicalManager: (GhostLi) AuthorizedSignatory: (TerryYang) / Page3of31 ReportNo.:SHATBL2210013W01 ShanghaiATBLTechnologyCo.,Ltd.Number:SHATBL-W-05Releasedate:2022-03-01VersionNo.A/1 TableofContents 1.SUMMARYOFTESTRESULTS..............................................................................................6 2.GENERALINFORMATION.......................................................................................................7 2.1GENERALDESCRIPTIONOFTHEEUT..........................................................................7 2.2DESCRIPTIONOFTHETESTMODES............................................................................8 2.3BLOCKDIAGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED.............8 2.4DESCRIPTIONOFNECESSARYACCESSORIESANDSUPPORTUNITS..................9 2.5LABORATORYINFORMATION.........................................................................................9 2.6MEASUREMENTUNCERTAINTY.....................................................................................9 2.7EQUIPMENTSLIST.........................................................................................................10 3.EMCEMISSIONTEST............................................................................................................12 3.1CONDUCTEDEMISSIONMEASUREMENT..................................................................12 3.2TESTPROCEDURE........................................................................................................12 3.3TESTSETUP...................................................................................................................13 3.4EUTOPERATINGCONDITIONS....................................................................................13 3.5TESTRESULTS................................................................................................................13 4.RADIATEDEMISSIONMEASUREMENT..............................................................................14 4.1RADIATEDEMISSIONLIMITS........................................................................................14 4.2TESTPROCEDURE........................................................................................................16 4.3TESTSETUP...................................................................................................................17 4.4EUTOPERATINGCONDITIONS....................................................................................17 4.5FIELDSTRENGTHCALCULATION................................................................................18 5.BANDWIDTHTEST................................................................................................................24 5.1LIMIT................................................................................................................................24 5.2TESTSETUP...................................................................................................................24 5.3EUTOPERATIONCONDITIONS....................................................................................24 5.4TESTRESULTS...............................................................................................................25 6.DUTYCYCLE..........................................................................................................................26 6.1TESTPROCEDURE........................................................................................................26 6.2TESTSETUP.......................................................…

Text truncated - open the document above for the full version.

Test Report

ReportNo.:SHATBL2210011 "ShanghaiATBLTechnologyCo.,Ltd."herebycertifiesthatthetestresultsdescribedinthecompany'sstandardtestsitetest reportandthestructureofthetestequipmentarerecordedindetailbasedontheactualtestsituation.Thetestresultsofthis reportareonlyapplicabletotheabove-mentionedtestedprototypesandtheequipmentdescribedinthereport.Thisreportis notallowedtobecopiedwithoutthewrittenconsentofShanghaiATBLTechnologyCo., Ltd.;ShanghaiATBLTechnologyCo.,Ltd. Building8,No.160Bashengroad,WaigaoqiaoFreeTradeZone,PudongNewArea,Shanghai Tel:+86(0)21-51298625Web:www.atbl-lab.com OTATESTREPORT ............: .............: ReportPreparedby ClientInformation: Applicant...............................:Zhejiang General Light Curtain Co.,LTD. Addressadd.............................:Xin Tang Tou Village, Xin Jie Town, Xiao Shan District, Hang Zhou City, Zhe Jiang Province, China oduct Description...............:PCB antenna Product Name..........................: P CB antenna Model Name.............................: P EM Date of Test...................................18 Nov. 2022 Date of Issue................................18 Nov. 2022 : (qiyaozhao) ReportApprovedby: (leoLi) AuthorizedSignatory: (Terryyang) Page2of7ReportNo.:SHATBL2210011 ShanghaiATBLTechnologyCo.,Ltd. RevisionHistory Rev.IssueDateReportNo.EffectPageContents 00 18Nov.2022 SHATBL2210011ALLInitialIssue Page3of7ReportNo.:SHATBL2210011 ShanghaiATBLTechnologyCo.,Ltd. 1. Samplephoto Page4of7ReportNo.:SHATBL2210011 ShanghaiATBLTechnologyCo.,Ltd. 2.Testlayout Page5of7ReportNo.:SHATBL2210011 ShanghaiATBLTechnologyCo.,Ltd. 3.ResultsSummary(2D/3DRadiationPattern/Efficiency) Frequency(MHz)Gain(dB)Efficiency(dB)Efficiency(%) 400-4.303-8.51714.067 405-4.367-8.65513.627 410-4.162-8.62713.718 415-3.893-8.69213.512 420-3.536-9.01112.556 425-3.788-9.19912.025 430-4.148-9.37711.541 433-4.886-9.63810.868 435-5.182-9.70310.707 440-5.311-9.66110.810 445-5.724-9.82010.422 450-6.012-9.99610.0075 Overview Page6of7ReportNo.:SHATBL2210011 ShanghaiATBLTechnologyCo.,Ltd. 2/3D方向图带壳 Page7of7ReportNo.:SHATBL2210011 ShanghaiATBLTechnologyCo.,Ltd. 4. SWR

Test Setup Photos

APPENDIX-PHOTOSOFTEST RadiatedEmissionsfor9kHz~30MHzRadiatedEmissionsfor30MHz~1GHz RadiatedEmissionsfor1GHz~5GHz N/A ※※※※※ENDOFTHEREPORT※※※※※

Contact Information

Applicant

Guo Lei
[email protected]13958152062Fax: 13958152062

Test Firm

Shanghai ATBL Technology Co., Ltd.Haofei Huang
[email protected]13818033377

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from Zhejiang General Light Curtain Co.,LTD.

Button Transmitter - FCC ID 2A839-PE3015 - Zhejiang General Light Curtain Co.,LTD.
2A839-PE3015

Button Transmitter

Mar 23, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Rechargeable Transmitter - FCC ID 2A839-PE5115-C - Zhejiang General Light Curtain Co.,LTD.
2A839-PE5115-C

Rechargeable Transmitter

Jan 28, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
TUBULAR MOTOR - FCC ID 2A839-PD25TEQ - Zhejiang General Light Curtain Co.,LTD.
2A839-PD25TEQ

TUBULAR MOTOR

Sep 29, 2025

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter
TUBULAR MOTOR - FCC ID 2A839-PD28TEQ - Zhejiang General Light Curtain Co.,LTD.
2A839-PD28TEQ

TUBULAR MOTOR

Sep 29, 2025

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter
Remote Control - FCC ID 2A839-PEM202 - Zhejiang General Light Curtain Co.,LTD.
2A839-PEM202

Remote Control

May 22, 2023

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter