Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Nov 09, 2022
Application Purpose
Original Equipment
Date of Application
Nov 09, 2022
Equipment Note
MOBILE PHONE
Frequency Range
1852.40000000 - 1907.60000000
Company
RUA Trading LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

MOBILE PHONE

Cover Letter(s)

RUA TradingLLC Office of EngineeringTechnology FederalCommunicationsCommission 7435 OaklandMills Road Columbia,MD 21046 USA Subject;Requestfor Long Term Confidentiality FCC ID: 2A8N5G1PORTO Date: 2022-11-02 To WhomIt May Concern, Pursuantto the provisionsof the Commission’s rules Title 47 Sections§0.457 and §0.459,we are requestingthe Commissionto withholdthe followingattachment(s)as confidential documentsfrom public disclosureindefinitely. Thesedocumentscontaindetailedsystemand equipmentdescriptionsand are consideredas proprietaryinformationin operationof the equipment.The public disclosureof these documents might be harmfulto our companyand would give competitorsan unfair advantagein the market. SchematicDiagram Block Diagram Parts List OperationalDescription Tune-upProcedure It is our understandingthat all measurementtest reports,FCC ID label formatand correspondenceduringthe certificationreviewprocesscannotbe grantedas confidential documentsand this informationwill be availablefor public reviewonce the grant of equipment authorizationis issued. Sincerely, Signature: Name:MurtazaPanjwani Title: Manager

Cover Letter(s)

RUATradingLLC AgentAuthorization Company:RUATradingLLC Address:8212NW30thTerr,Doral,Florida33122,UnitedStates ProductName:MOBILEPHONE ModelNumber(s):G1Porto ProductDescription:MOBILEPHONE WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown. Signature:Date:2022-11-02 Name:MurtazaPanjwani Title:Manager Company:RUATradingLLC

External Photos

Page 1 of 4 Appendix C: Photographs of EUT Product: MOBILE PHONE Model: G1 Porto External Photos Page 2 of 4 Page 3 of 4 Page 4 of 4

ID Label/Location Info

LabelArtworkandLocation Model:G1Porto Label: Size:L*W=20*25mm Location

Internal Photos

Page 1 of 6 Appendix C: Photographs of EUT Product: MOBILE PHONE Model: G1 Porto Internal Photos GSM/WCDMA ANT Page 2 of 6 Page 3 of 6 Page 4 of 6 BT ANT Page 5 of 6 Page 6 of 6

RF Exposure Info

Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com SAR TEST REPORT FCC ID. ............................ : 2A8N5G1PORTO Test Report No. ............... : TCT220920E020 Date of issue ................... : Oct. 28, 2022 Testing laboratory .......... : SHENZHEN TONGCE TESTING LAB Testing location/ address: 2101 & 2201, Zhenchang Factory Renshan Industrial Zone, Fuhai Subdistrict, Bao'an District, Shenzhen, Guangdong, 518103, People's Republic of China Applicant's name ............ : RUA Trading LLC Address ........................... : 8212 NW 30th Terr, Doral, Florida 33122, United States Manufacturer's name ... : RUA Trading LLC Address ........................... : 8212 NW 30th Terr, Doral, Florida 33122, United States Product Name ................. : MOBILE PHONE Trade Mark ...................... : GOL Model/Type reference..... : G1 Porto SAR Max. Values..............: 0.491 W/Kg (1g) for head; 1.550 W/Kg (1g) for Body-worn Date of receipt of test item ......................................... : Sep. 20, 2022 Date (s) of performance of test ................................... : Sep. 20, 2022 ~ Oct. 28, 2022 Tested by (+signature) ... : Una LI Check by (+signature) .... : Beryl ZHAO Approved by (+signature): Tomsin General disclaimer: This report shall not be reproduced except in full, without the written approval of SHENZHEN TONGCE TESTING LAB. This document may be altered or revised by SHENZHEN TONGCE TESTING LAB personnel only, and shall be noted in the revision section of the document. The test results in the report only apply to the tested sample. Report No.: TCT220920E020 Page 2 of 108 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com TABLE OF CONTENTS 1. General Product Information ............................................................................................................. 4 1.1. EUT description .......................................................................................................................... 4 1.2. Model(s) list ................................................................................................................................. 4 2. Test standard ....................................................................................................................................... 5 3. Facilities and Accreditations ............................................................................................................. 5 3.1. Facilities ....................................................................................................................................... 5 3.2. Location ....................................................................................................................................... 5 3.3. Environment Condition: ............................................................................................................. 5 4. Test Result Summary ......................................................................................................................... 6 5. RF Exposure Limit .............................................................................................................................. 7 6. SAR Measurement System Configuration ....................................................................................... 8 6.1. SAR Measurement Set-up .......................................................................................................... 8 6.2. E-field Probe ................................................................................................................................ 9 6.3. Phantom ....................................................................................................................................... 9 6.4. Device Holder ............................................................................................................................ 10 6.5. Data Storage and Evaluation ................................................................................................... 11 6.6. Position of the wireless device in relation to the phantom ................................................. 12 6.7. Tissue Dielectric Parameters .................................................................................................. 15 6.8. Tissue-equivalent Liquid Properties ...................................................................................... 16 6.9. System Check ........................................................................................................................... 17 7. Measurement Procedure .................................................................................................................. 18 8. Conducted Output Power ................................................................................................................. 21 9. Exposure Position Consideration ................................................................................................... 25 9.1. EUT Antenna Location ............................................................................................................. 25 9.2. Test Position Consideration .................................................................................................... 25 10. SAR Test Results Summary............................................................................................................. 26 10.1. Head 1g SAR Data .................................................................................................................... 26 10.2. Body-Worn 1g SAR Data .......................................................................................................... 27 10.3. Simultaneous Transmission Conclusion ............................................................................... 28 10.4. SAR Simultaneous Transmission Analysis ........................................................................... 30 10.5. …

Text truncated - open the document above for the full version.

RF Exposure Info

Report No.: TCT220920E020 Page 87 of 108 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT220920E020 Page 88 of 108 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT220920E020 Page 89 of 108 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT220920E020 Page 90 of 108 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT220920E020 Page 91 of 108 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT220920E020 Page 92 of 108 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT220920E020 Page 93 of 108 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT220920E020 Page 94 of 108 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT220920E020 Page 95 of 108 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com SID1900 Report No.: TCT220920E020 Page 96 of 108 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT220920E020 Page 97 of 108 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT220920E020 Page 98 of 108 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT220920E020 Page 99 of 108 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT220920E020 Page 100 of 108 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT220920E020 Page 101 of 108 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT220920E020 Page 102 of 108 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT220920E020 Page 103 of 108 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT220920E020 Page 104 of 108 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT220920E020 Page 105 of 108 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Report No.: TCT220920E020 Page 106 of 108 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Appendix E: SAR SYSTEM VALIDATION Per FCC KDB 865664 D02v01, SAR system validation status should be documented to confirm measurement accuracy. The SAR systems (including SAR probes, system components and software versions) used for this device were validated against its performance specifications prior to the SAR measurements. Reference dipoles were used with the required tissue- equivalent media for system validation, according to the procedures outlined in FCC KDB 865664 D01 v01 and IEEE 1528-2013. Since SAR probe calibrations are frequency dependent, each probe calibration point was validated at a frequency within the valid frequency range of the probe calibration point, using the system that normally operates with the probe for routine SAR measurements and according to the required tissue-equivalent media. A tabulated summary of the system validation status including the validation date(s), measurement frequencies, SAR probes and tissue dielectric parameters has been included. SAR System Validation Summary Date Freq. [MHz] Probe S/N Tissu e type COND. PERM. COND. PERM. CW Validation Mod. Validation (σ) (εr) sensitivity Probe linearity Probe isotropy Mod. type Duty factor Peak to average power ratio 05/27/2022 835 SN 36/20 EPGO3 46 Head 42.3 0.89 PASS PASS PASS GMSK PASS N/A 05/31/2022 835 SN 36/20 EPGO3 46 Body 55.13 0.95 PASS PASS PASS GMSK PASS N/A 05/27/2022 1900 SN 36/20 EPGO3 46 Head 40.31 1.38 PASS PASS PASS GMSK PASS N/A 05/31/2022 1900 SN 36/20 EPGO3 46 Body 53.11 1.56 PASS PASS PASS GMSK PASS N/A NOTE: While the probes have been calibrated for both a CW and modulated signals, all measurements were performed using communication systems calibrated for CW signals only. Modulations in the table above represent test configurations for which the measurement system has been validated per FCC KDB Publication 865664 D01v01 for scenarios when CW probe calibrations are used with other signal types. SAR systems were validated for modulated signals with a periodic duty cycle, such as OFDM according to KDB 865664. Report No.: TCT220920E020 Page 107 of 108 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Appendix F: The Check Data of Impedance and Return Loss The information are included in the SAR report to qualify for the three-year extended calibration interval; Impedance in head liquid Date: 05/27/2022 Freq. (MHz) Temp (°C) Dipole Impedance Re(z) Dipole Impedance Im(z) measured Target △(±5Ω) measured Target △(±5Ω) 835 22 52.30 51.60 0.7 2.30 1.70 0.6 1900 22 50.30 51.70 -1.4 4.20 4.90 -0.7 Impedance in body liquid Date: 05/31/2022 Freq. (MHz) Temp (°C) Dipole Impedance Re(z) Dipole Impedance Im(z) measured Target △(±5Ω) measured Target △(±5Ω) 835 22 49.3 47.1 2.2 6.3 5.60 0.7 1900 22 50.3 48.1 2.2 5.3 6.40 -1.1 Return loss in head liquid Date: 05/27/2022 Freq. (MHz) Temp (°C) Return loss(dB) measured Target △(±20%) 835 22 -30.35 -32.78 -7.41 1900 22 -24.33 -25.64 -5.11 Return loss in body liquid Date: 05/31/2022 Freq. (MHz) Temp (°C) Return loss(dB) measured Target △(±20%) 835 22 -25.99 -23.99 8.34 1900 22 -21.65 -23.50 -7.87 Report No.: TCT220920E020 Page 108 of 108 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com liquid Freq. (MHz) Temp (°C) εr / relative permittivity σ(s/m) / conductivity ρ (kg/m3) measured Target △(±5%) measured Target △(±5%) Head 835 22 42.30 41.50 1.93 0.89 0.90 …

Text truncated - open the document above for the full version.

Test Report

Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com TEST REPORT FCC ID. ............................ : 2A8N5G1PORTO Test Report No. ............... : TCT220920E022 Date of issue ................... : Oct. 26, 2022 Testing laboratory .......... : SHENZHEN TONGCE TESTING LAB Testing location/ address: 2101 & 2201, Zhenchang Factory Renshan Industrial Zone, Fuhai Subdistrict, Bao'an District, Shenzhen, Guangdong, 518103, People's Republic of China Applicant's name ............ : RUA Trading LLC Address ........................... : 8212 NW 30th Terr, Doral, Florida 33122, United States Manufacturer's name ... : RUA Trading LLC Address ........................... : 8212 NW 30th Terr, Doral, Florida 33122, United States Standard(s) ..................... : FCC CFR Title 47 Part 2 FCC CFR Title 47 Part22 FCC CFR Title 47 Part24 Product Name ................. : MOBILE PHONE Trade Mark ...................... : GOL Model/Type reference..... : G1 Porto Rating(s).......................... : Refer to EUT description of page 3 Date of receipt of test item ......................................... : Sep. 20, 2022 Date (s) of performance of test ................................... : Sep. 20, 2022 - Oct. 26, 2022 Tested by (+signature) ... : Brews XU Check by (+signature) .... : Beryl ZHAO Approved by (+signature): Tomsin General disclaimer: This report shall not be reproduced except in full, without the written approval of SHENZHEN TONGCE TESTING LAB. This document may be altered or revised by SHENZHEN TONGCE TESTING LAB personnel only, and shall be noted in the revision section of the document. The test results in the report only apply to the tested sample. Report No.: TCT220920E022 Page 2 of 54 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Table of Contents 1. General Product Information .................................................................. 3 1.1. EUT description ..................................................................................................... 3 1.2. Model(s) list ............................................................................................................ 3 1.3. Operation Frequency ............................................................................................ 4 2. Test Result Summary .............................................................................. 5 3. General Information ................................................................................. 6 3.1. Test environment and mode ................................................................................. 6 3.2. Description of Support Units ................................................................................ 7 3.3. Configuration of Tested System .......................................................................... 8 3.4. Measurement Results Explanation Example ....................................................... 8 4. Facilities and Accreditations .................................................................. 9 4.1. Facilities ................................................................................................................. 9 4.2. Location ................................................................................................................. 9 4.3. Measurement Uncertainty ..................................................................................... 9 5. Test Results and Measurement Data ................................................... 10 5.1. Conducted Output Power Measurement ........................................................... 10 5.2. Peak to Average Ratio ......................................................................................... 12 5.3. 99% Occupied Bandwidth and 26dB Bandwidth Measurement ...................... 18 5.4. Band Edge and Conducted Spurious Emission Measurement ....................... 23 5.5. Effective Radiated Power and Effective Isotropic Radiated Power Measurement .............................................................................................................. 34 5.6. Field Strength of Spurious Radiation Measurement ........................................ 41 5.7. Frequency Stability Measurement ..................................................................... 49 Appendix B: Photographs of Test Setup Appendix C: Photographs of EUT Report No.: TCT220920E022 Page 3 of 54 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 1. General Product Information 1.1. EUT description Product Name ....................... : MOBILE PHONE Model/Type reference........... : G1 Porto Sample Number....................: TCT220920E021-0101 3G Version ............................ : WCDMA: R99 HSDPA: Release 5 HSUPA: Release 6 Tx Frequency ........................ : GSM/GPRS 850: 824.2MHz ~ 848.8MHz GSM/GPRS 1900: 1850.2MHz ~ 1909.8MHz WCDMA Band V: 826.4MHz ~ 846.6MHz WCDMA Band II: 1852.4MHz ~ 1907.6MHz Rx Frequency ....................... : GSM/GPRS/EGPRS 850: 869.2MHz ~ 893.8MHz GSM/GPRS/EGPRS 1900: 1930.2MHz ~ 1989.8MHz WCDMA Band V: 871.4MHz ~ 891.6MHz WCDMA Band II: 1932.4MHz ~ 1987.6MHz Maximum Output Power to Antenna ................. : GSM850: 32.66dBm GSM1900: 28.12Bm GPRS850: 32.64dBm GPRS1900: 28.10dBm WCDMA Band V: 22.04dBm WCDMA Band II: 21.38dBm 99% Occupied Bandwidth ............................. : GSM850: 248KGXW GSM1900: 247KGXW GPRS850 Class 8: 248KGXW GPRS1900 Class 8: 247KGXW WCDMA Band V RMC 12.2Kbps: 4M11F9W WCDMA Band II RMC 12.2Kbps: 4M10F9W Type of Modulation............... : GSM/GPRS: GMSK WCDMA/HSDPA/HSUPA: QPSK Antenna Type ........................ : Internal Antenna Antenna Gain ........................ : GSM/GPRS 850: -2.9dBi GSM/GPRS 1900: -0.9dBi WCDMA Band V: -2.9dBi WCDMA Band II: -0.9dBi Rating(s)................................ : Adapter Information: Model: G1 Porto Input: AC 110-240V, 50/60Hz, 0.12A Output: DC 5.0V, 500mA Recharg…

Text truncated - open the document above for the full version.

Test Report

High gain Omani-directional Wide bandwidth Main Antenna Application: GSM850/900/1800/1900 WCDMAB2/B5 BT communication applications Main Antenna BT Antenna Antenna length 28mm Antenna material lead Antenna picture

Test Setup Photos

Page 1 of 1 Appendix B: Photographs of Test Setup Product: MOBILE PHONE Model: G1 Porto Radiated Emission

Contact Information

Applicant

Murtaza Panjwani
[email protected]1-305-372-9590Fax: 1-305-372-9590

Technical Contact

RUA Trading LLC
[email protected]

United States

Test Firm

SHENZHEN TONGCE TESTING LABBeryl Zhao
[email protected]+8675527208735

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
424E1.85 GHz - 1.91 GHz130.00 mW4M10F9W0.021 ppm
Confidentiality
Long Term
Grant Notes
Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, and simultaneous transmission use conditions is 0.49W/kg, 1.55W/kg and 1.59W/kg respectively. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.

Other Applications from RUA Trading LLC

S1 Napoli - FCC ID 2A8N5S1NAPOLI - RUA Trading LLC
2A8N5S1NAPOLI

S1 Napoli

Jul 05, 2023

Equipment Class

PCE - PCS Licensed Transmitter held to ear