FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. RUA Trading LLC/
  3. 2A8N5S1NAPOLI

2A8N5S1NAPOLIS1 Napoli

RUA Trading LLC
S1 Napoli - FCC ID 2A8N5S1NAPOLI - RUA Trading LLC
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Jul 05, 2023
Application Purpose
Original Equipment
Date of Application
Jul 05, 2023
Equipment Note
S1 Napoli
Frequency Range
1850.20000000 - 1909.80000000
Company
RUA Trading LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

RUA Trading LLC 8212 NW 30th Terr, Doral, FL 33122 USA Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2023-6-25 To whom it may concern: We, RUA Trading LLC, hereby certify that the equipment for which authorization is sought FCC ID: 2A8N5S1NAPOLI is not “covered” equipment prohibited from receiving an equipment authorization pursuant to § 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, we are not identified on the Covered List (https://www.fcc.gov/supplychain/coveredlist) as an entity producing “covered” equipment. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(b) and (d)(5) and (6). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. RUA Trading LLC 8212 NW 30th Terr, Doral, FL 33122 USA Sincerely, Signature Murtaza Panjwani RUA Trading LLC 62_[model] CoveredEqu_2.911(d)(5)(i) and (ii) - U, V03

Attestation Statements

RUA Trading LLC 8212 NW 30th Terr, Doral, FL 33122 United States Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2023-6-25 U.S. Agent Designation RUA Trading LLC acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought FCC ID: 2A8N5S1NAPOLI Name and company of U.S. agent: RUA Trading LLC Physical U.S. address of agent: 8212 NW 30th Terr, Doral, FL United States 33122 FRN of U.S. agent: 0032877219 Email address of U.S. agent: [email protected] RUA Trading LLC acknowledges their obligation to accept service of process on behalf of RUA Trading LLC. RUA Trading LLC with the FRN 0032877219 accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Sincerely, Signature Murtaza Panjwani RUA Trading LLC Signature Murtaza Panjwani RUA Trading LLC 48_[mo del] US_Agent_2.911(d)(7) - U, V0 5

Cover Letter(s)

CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date:<2023-6-25> Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2A8N5S1NAPOLI S1 Napoli For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below.

Cover Letter(s)

RUA Trading LLC 8212 NW 30th Terr Doral, FL 33122 United States Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2023-6-25 To whom it may concern: We, RUA Trading LLC the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2A8N5S1NAPOLI including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. By signing this application form, we agree to Eurofins’ current valid General Terms and Conditions (AGB),Testing and Certification Regulations (PZO) which can be viewed on following website www.eurofins.de/ee or retrieved on request. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name/Title: Murtaza Panjwani/Manager Company: RUA Trading LLC Address: 8212 NW 30th Terr. Doral, FL 33122 United States Phone: 1-305-372-9590 Fax: 1-305-372-9590 E-Mail: [email protected]

External Photos

FCC ID: 2A8N5S1NAPOLI TB-RF-074-1.0 Appendix III EUT External Photographs Photo 1 Appearance of EUT Photo 2 Appearance of Adapter FCC ID: 2A8N5S1NAPOLI TB-RF-074-1.0 Photo 3 Appearance of EUT Photo 4 Appearance of EUT

ID Label/Location Info

FCC ID: 2A8N5S1NAPOLI TB-RF-074-1.0 Appendix I Label FCC ID: 2A8N5S1NAPOLI Model: S1 Napoli FCC ID: 2A8N5S1NAPOLI TB-RF-074-1.0 Appendix II Label Location

Internal Photos

FCC ID: 2A8N5S1NAPOLI TB-RF-074-1.0 Appendix IV EUT Internal Photographs Photo 5 Internal of EUT Photo 6 Internal of EUT GSM Antenna FCC ID: 2A8N5S1NAPOLI TB-RF-074-1.0 Photo 7 Internal of EUT Photo 8 Appearance of PCB BT Antenna FCC ID: 2A8N5S1NAPOLI TB-RF-074-1.0 Photo 9 Appearance of PCB

RF Exposure Info

Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 1 of 47 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China SAR Test Report For Applicant Name: RUA Trading LLC Address: 8212 NW 30th Terr Doral, Florida 33122, United States EUT Name: S1 Napoli Model Number: S1 Napoli Brand Name: GOL Issued By Company Name: BTF Testing Lab (Shenzhen) Co., Ltd. Address: F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Report Number: BTF230613R00101 Test Standards: 47 CFR Part 2.1093 IEEE1528-2013 IEEE C95.1-2019 KDB447498 D01 KDB447498 D04 KDB865664 D01 KDB865664 D02 KDB941225 D01 KDB648474 D04 KDB690783 D01 FCC ID: 2A8N5S1NAPOLI Test Conclusion: Pass Test Date: 2023-06-16 Date of Issue: 2023-06-16 Prepared By: Monica Zhou / Project Engineer Date: 2023-06-16 Approved By: Ryan.CJ / EMC Manager Date: 2023-06-16 Note: All the test results in this report only related to the testing samples. Which can be duplicated completely for the legal use with approval of applicant; it shall not be reproduced except in full without the written approval of BTF Testing Lab (Shenzhen) Co., Ltd., All the objections should be raised within thirty days from the date of issue. To validate the report, you can contact us. Test Report Number: BTF230613R00101 Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 2 of 47 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Revision History Version Issue Date Revisions Content R_V0 2023-06-16 Original Note: Once the revision has been made, then previous versions reports are invalid. Test Report Number: BTF230613R00101 Total or partial reproduction of this document without permission of the Laboratory is not allowed. Page 3 of 47 BTF Testing Lab (Shenzhen) Co., Ltd. F101, 201 and 301, Building 1, Block 2, Tantou Industrial Park, Tantou Community, Songgang Street, Bao'an District, Shenzhen, China Table of Contents 1. Introduction ............................................................................................................................................................................................... 4 1.1 Identification of Testing Laboratory ............................................................................................................................................. 4 1.2 Identification of the Responsible Testing Location .................................................................................................................... 4 1.3 Laboratory Condition ..................................................................................................................................................................... 4 1.4 Announcement ............................................................................................................................................................................... 4 2. Product Information .................................................................................................................................................................................. 5 2.1 Application Information .................................................................................................................................................................. 5 2.2 Manufacturer Information .............................................................................................................................................................. 5 2.3 Factory Information ........................................................................................................................................................................ 5 2.4 General Description of Equipment under Test (EUT) ............................................................................................................... 5 2.5 Equipment under Test Ancillary Equipment ............................................................................................................................... 5 2.6 Technical Information .................................................................................................................................................................... 5 3. Summary of Test Results ........................................................................................................................................................................ 6 3.1 Test Standards ............................................................................................................................................................................... 6 3.2 Device Category and SAR Limit .................................................................................................................................................. 7 3.3 Test Result Summary .................................................................................................................................................................... 7 3.4 Test Uncertainty ............................................................................................................................................................................. 8 4. Measurement System ............................................................................................................................................................................ 10 4.1 Specific Absorption Rate (SAR) Definition ............................................................................................................................... 10 4.2 MVG SAR System ................................................................................................…

Text truncated - open the document above for the full version.

Test Report

天线测试数据报告 Antenna test data report 深圳麒鑫通达科技有限公司 custom:Kechao Daproject:K20EFrequency band:G4engineering:Ma Fei (134 1821 8312)date:May 15, 2023custom:Kechao Daproject:K20EFrequency band:G4engineering:Ma Fei (134 1821 8312)date:May 15, 2023 Shenzhen Qixin Tongda technology co., ltd 2 Test items and equipment 测试项目 设备 1. s-parameter 1. RL 2. VSWR) network analyzer: Agilent 5071B 2. Coupling power test 1. power2. level) Comprehensive me asuring instrument: CMW500/8960Darkroom:6*4*3微波暗室 3 Main board model and complete machine 4 Main signal source matching circuit diagram Element Value E1 Unchanged E2 Unchanged E3 Unchanged E4 Unchanged 5 Antenna radiation test data (active) 手机型号 1# Test items GSM900Measurement value DCS1800Measurement value Channel 1 62 124 512 698 885 TRP(dBm) 28.27 28.73 28.94 23.22 24.04 24.74 TIS(dBm) -104.04 -103.72 -103.47 -105.69 -105.43 -105.37 maximum power 30.48 30.97 31.27 26.03 26.49 27.24 Minimum receiving sensitivity -106.62 -106.34 -106.03 -109.7 -109.54 -109.31 (DBI) 0.5 0.5 0.5 0.7 0.7 0.7 Test items GSM850Measurement value PCS1900Measurement value Channel 128 190 251 512 661 810 TRP(dBm) 25.37 25.74 26.5 26.33 25.8 25.27 TIS(dBm) -104.81 -105.14 -105.42 -102.79 -102.24 -101.86 maximum power 27.48 28.0 28.88 29.25 29.03 28.78 Minimum receiving sensitivity -107.2 -107.53 -107.89 -106.22 -105.67 -105.19 (DBI) 0.5 0.5 0.5 0.8 0.8 0.8 6 GSM850-TRP GSM850-TIS GSM900-TRP GSM900-TIS 3D field strength map 7 DCS1800-TRP DCS1800-TIS PCS1900-TRP PCS1900-TIS 3D field strength map 8 NO. ITEMS DETAILS 1 Operatingband BT 2 Frequency range (2400~2500MHz) 3 Antenna Type Monopole antenna 4 Antenna material and implementation form Pure copper core wire 5 Impedance 50 ( Ω ) 6 Gain ≤ 1.5 dBi Bluetooth parameters 9 Bluetooth parameters Frequency Efficiency(%) Gain(db) 2400MHZ 43.1 1.4 2420MHZ 43.6 1.45 2440MHZ 40.8 1.3 2460MHZ 41.9 1.5 2480MHZ 43.7 1.6 2500MHZ 45.2 1.7 2400mhz Bluetooth parameters 2420mhz Bluetooth parameters 2440mhz Bluetooth parameters 2460mhz Bluetooth parameters 2480mhz Bluetooth parameters 2500mhz Bluetooth parameters 努力为客户提供更佳的服务 地址:深圳市福田区车公庙泰然工业区泰然九路211栋503室 联系电话:83443630 Address: Room 503, Building 211, Teran 9 Road, Teran Industrial Zone, Chegongmiao, Futian District, ShenzhenTel: 83443630

Test Report

Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0096-31 Page: 1 of 23 FCC ID: 2A8N5S1NAPOLI TB-RF-074-1.0 FCC GSM Test Data General Description of EUT Product Name: S1 Napoli Test Model: S1 Napoli Sample ID: 202207-0016-3-2# Environmental Conditions Temperature: 24°C Relative Humidity: 50% Test Voltage: DC 3.7V Test Engineer: Huang jian ping Note: For a more detailed features description, please refer to the report TBR-C-202305-0096-31 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0096-31 Page: 2 of 23 FCC ID: 2A8N5S1NAPOLI TB-RF-074-1.0 Appendix A: Conducted Output Power Data Test Result Band Channel PCL Conducted Power (dBm) Limit(dBm) Verdict GSM850 128 5 33.76 38.45 PASS GSM850 190 5 33.65 38.45 PASS GSM850 251 5 33.63 38.45 PASS GSM1900 512 0 30.04 33.00 PASS GSM1900 661 0 29.79 33.00 PASS GSM1900 810 0 29.58 33.00 PASS Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0096-31 Page: 3 of 23 FCC ID: 2A8N5S1NAPOLI TB-RF-074-1.0 Appendix B: Peak-to-Average Ratio(CCDF) Test Result Band Channel PCL Result(dB) Limit(dB) Verdict GSM850 128 5 2.66 13 PASS GSM850 190 5 2.66 13 PASS GSM850 251 5 2.66 13 PASS GSM1900 512 0 2.67 13 PASS GSM1900 661 0 2.68 13 PASS GSM1900 810 0 2.68 13 PASS Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0096-31 Page: 4 of 23 FCC ID: 2A8N5S1NAPOLI TB-RF-074-1.0 Test Graphs GSM850-128 GSM850-190 GSM850-251 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0096-31 Page: 5 of 23 FCC ID: 2A8N5S1NAPOLI TB-RF-074-1.0 GSM1900-512 GSM1900-661 GSM1900-810 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0096-31 Page: 6 of 23 FCC ID: 2A8N5S1NAPOLI TB-RF-074-1.0 Appendix C: 26dB Bandwidth and Occupied Bandwidth Test Result Band Channel PCL Occupied Bandwidth (MHz) 26dB Bandwidth (MHz) Limit (MHz) Verdict GSM850 128 5 0.24569 0.3127 --- PASS GSM850 190 5 0.24876 0.3144 --- PASS GSM850 251 5 0.24496 0.3084 --- PASS GSM1900 512 0 0.24679 0.3159 --- PASS GSM1900 661 0 0.24428 0.3108 --- PASS GSM1900 810 0 0.24420 0.3114 --- PASS Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0096-31 Page: 7 of 23 FCC ID: 2A8N5S1NAPOLI TB-RF-074-1.0 Test Graphs GSM850-128 GSM850-190 GSM850-251 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0096-31 Page: 8 of 23 FCC ID: 2A8N5S1NAPOLI TB-RF-074-1.0 GSM1900-512 GSM1900-661 GSM1900-810 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0096-31 Page: 9 of 23 FCC ID: 2A8N5S1NAPOLI TB-RF-074-1.0 Appendix D: Band Edge Test Result Band Channel PCL Freq (MHz) Result (dBm) Limit(dBm) Verdict GSM850 128 5 823.99 -22.47 -13 PASS GSM850 251 5 849.02 -20.67 -13 PASS GSM1900 512 0 1849.97 -27.20 -13 PASS GSM1900 810 0 1910.02 -25.25 -13 PASS Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0096-31 Page: 10 of 23 FCC ID: 2A8N5S1NAPOLI TB-RF-074-1.0 Test Graphs GSM850-128 GSM850-251 GSM1900-512 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0096-31 Page: 11 of 23 FCC ID: 2A8N5S1NAPOLI TB-RF-074-1.0 GSM1900-810 Shenzhen Toby Technology Co., Ltd. Http://www.tobylab.cn Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202305-0096-31 Page: 12 of 23 FCC ID: 2A8N5S1NAPOLI TB-RF-074-1.0 Appendix E: Conducted Spurious Emission Test Result Band Channel PCL Frequency Range(MHz) Max.Freq. (MHz) Result (dBm) Limit (dBm) Verdict GSM850 128 5 0.009~0.15MHz 0.01 -47.78 -33 PASS GSM850 128 5 0.15~30MHz 0.15 -38.59 -13 PASS GSM850 128 5 30~1000MHz 935.85 -44.48 -13 PASS GSM850 128 5 1000~10000MHz 1697.8 -32.06 -13 PASS GSM850 190 5 0.009~0.15MHz 0.01 -49.27 -33 PASS GSM850 190 5 0.15~30MHz 0.15 -39.06 -13 PASS GSM850 190 5 30~1000MHz 949.72 -44.41 -13 PASS GSM850 190 5 1000~10000MHz 2546.5 -32.25 -13 PASS GSM850 251 5 0.009~0.15MHz 0.01 -50.11 -33 PASS GSM850 251 5 0.15~30MHz 0.16 -39.35 -13 PASS GSM850 251 5 30~1000MHz 635.28 -44.27 -13 PASS GSM850 251 5 1000~10000MHz 2545.9 -32.25 -13 PASS GSM1900 512 0 0.009~0.15MHz 0.01 -48.43 -43 PASS GSM1900 512 0 0.15~30MHz 0.15 -37.79 -23 PASS GSM1900 512 0 30~1000MHz 930 -45.06 -13 PASS GSM1900 512 0 1000~18000MHz 17734.8 -15.99 -13 PASS GSM1900 661 0 0.009~0.15MHz 0.01 -48.64 -43 PASS GSM1900 661 0 0.15~30MHz 0.16 -40.07 -23 PASS GSM1900 661 0 30~1000MHz 836.13 -44.64 -13 PASS GSM1900 661 0 1000~18000MHz 17733.1 -15.75 -13 PASS GSM1900 810 0 0.009~0.15MHz 0.01 -50.49 -43 PASS GSM1900 810 0 0.15~30MHz 0.15 -39.16 -23 PASS GSM1900 810 0 30~1000MHz 775.67 -45.81 -13…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Toby Technology Co., Ltd. Report No.: TBR-C-202305-0096-31 Page: 1 of 28 TB-RF-074-1.0 1/F., Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China Tel: +86 75526509301 Fax: +86 75526509195 FCC Radio Test Report FCC ID: 2A8N5S1NAPOLI Original Grant Report No. : TBR-C-202305-0096-31 Applicant : RUA Trading LLC Equipment Under Test (EUT) EUT Name : S1 Napoli Model No. : S1 Napoli Series Model No. : ---- Brand Name : GOL Sample ID : RW-C-202305-0096-2-1#& RW-C-202305-0096-2-2# Receipt Date : 2023-05-25 Test Date : 2023-05-25 to 2023-06-10 Issue Date : 2023-06-16 Standards : FCC Part 2, FCC Part 22 Subpart H, FCC Part 24 Subpart E, FCC Part 27, ANSI/TIAC63.26: 2015 Conclusions : PASS In the configuration tested, the EUT complied with the standards specified above, The EUT technically complies with the FCC requirements Test/Witness Engineer : Seven Wu Engineer Supervisor : Ivan Su Engineer Manager : Ray Lai This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in the report. Report No.: TBR-C-202305-0096-31 Page: 2 of 28 TB-RF-074-1.0 Contents 1. GENERAL INFORMATION ABOUT EUT ............................................................................. 5 1.1 Client Information ................................................................................................................. 5 1.2 General Description of EUT (Equipment Under Test) ................................................... 5 1.3 Block Diagram Showing the Configuration of System Tested ...................................... 6 1.4 Description of Support Units .............................................................................................. 6 1.5 Description of Test Mode .................................................................................................... 7 1.6 Measurement Uncertainty .................................................................................................. 9 1.7 Test Facility ........................................................................................................................... 9 2. TEST SUMMARY ..................................................................................................................... 10 3. TEST EQUIPMENT .................................................................................................................. 11 4. FREQUENCY STABILITY ...................................................................................................... 13 4.1 Test Standard and Requirement ..................................................................................... 13 4.2 Test Setup ........................................................................................................................... 13 4.3 Test Procedure ................................................................................................................... 14 4.4 EUT Operating Condition ................................................................................................. 14 4.5 Deviation From Test Standard ......................................................................................... 14 4.6 Test Data ............................................................................................................................. 14 5. CONDUCTED RF OUTPUT POWER ................................................................................... 15 5.1 Test Standard and Limit .................................................................................................... 15 5.2 Test Setup ........................................................................................................................... 15 5.3 Test Procedure ................................................................................................................... 15 5.4 EUT Operating Condition ................................................................................................. 15 5.5 Deviation From Test Standard ......................................................................................... 15 5.6 Test Data ............................................................................................................................. 15 6. PEAK-AVERAGE RATIO ....................................................................................................... 16 6.1 Test Standard and Limit .................................................................................................... 16 6.2 Test Setup ........................................................................................................................... 16 6.3 Test Procedure ................................................................................................................... 16 6.4 EUT Operating Condition ................................................................................................. 16 6.5 Deviation From Test Standard ......................................................................................... 16 6.6 Test Data ............................................................................................................................. 16 RADIATED OUTPUT POWER .......................................................................................................... 17 7.1 Test Standard and Limit .................................................................................................... 17 Report No.: TBR-C-202305-0096-31 Page: 3 of 28 TB-RF-074-1.0 7.2 Test Setup ........................................................................................................................... 17 7.3 Test Procedure .....................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: 2A8N5S1NAPOLI TB-RF-074-1.0 Appendix V EUT Test Photographs Photo of Setup for Radiated Emission (30MHz~1GHz) Photo of Setup for Radiated Emission (Above 1 GHz) FCC ID: 2A8N5S1NAPOLI TB-RF-074-1.0 Photo of Setup for Conducted Emission -----END OF REPORT-----

Contact Information

Applicant

Murtaza Panjwani
[email protected]1-305-372-9590Fax: 1-305-372-9590

Test Firm

Shenzhen Toby Technology Co., Ltd.Ray Lai
[email protected]---

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
224E1.85 GHz - 1.91 GHz1.0139 W247KGXW2.5 ppm
Confidentiality
Long Term
Grant Notes
Output power listed is ERP below 1GHz and EIRP above 1GHz. This device contains functions that are not operational in U.S. and its territories. Filings under this FCC ID are approved only for U.S. operations. For body worn operation, the S1 Napoli has been tested and meets FCC RF exposure guidelines when used with an accessory that contains no metal and that positions the S1 Napoli a minimum of 10 mm from the body.Use of other accessories may not ensure compliance with FCC RF exposure guidelines. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values for head, body-worn accessory and simultaneous transmission use conditions are 0.92W/kg, 0.60 W/kg and 0.97 W/kg, respectively.

Other Applications from RUA Trading LLC

Z1 Roma JR - FCC ID 2A8N5Z1ROMAJR - RUA Trading LLC
2A8N5Z1ROMAJR

Z1 Roma JR

Jul 05, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
MOBILE PHONE - FCC ID 2A8N5S1PLUS - RUA Trading LLC
2A8N5S1PLUS

MOBILE PHONE

Jan 07, 2023

Equipment Class

PCE - PCS Licensed Transmitter held to ear
MOBILE PHONE - FCC ID 2A8N5G1PORTO - RUA Trading LLC
2A8N5G1PORTO

MOBILE PHONE

Nov 09, 2022

Equipment Class

PCE - PCS Licensed Transmitter held to ear