FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RF Exposure Information This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
Shenzhen Anxin Taihe Technology Co., ltd Agent Authorization Company: Shenzhen Anxin Taihe Technology Co., ltd Address: Room 201, No. 7, Baolongjun Industrial Zone, Jiuwo, Longping Community, Dalang Street, Longhua District, Shenzhen, China Product Name: MINIPC Trade Mark: KOOSMILE Model Number(s): KSM1 FCC ID: 2A8WM-KSM1 We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2022-11-01 Name: Dunzhang sun Title: project manager Company: Shenzhen Anxin Taihe Technology Co., ltd
Shenzhen Anxin Taihe Technology Co., ltd Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2022-11-01 Subject; Request for Confidentiality FCC ID: 2A8WM-KS95 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description Software Security Requirements For U-NII Devices In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Dunzhang sun Title: project manager
Page 1 of 5 FCC ID: 2A8WM-KSM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 5 FCC ID: 2A8WM-KSM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 5 FCC ID: 2A8WM-KSM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 5 FCC ID: 2A8WM-KSM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 5 FCC ID: 2A8WM-KSM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10
Page 1 of 1 FCC ID: 2A8WM-KSM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L: 3.0cm x W: 2.0cm) Label Location MINIPC Model: KSM1 FCC ID: 2A8WM-KSM1
Page 1 of 8 FCC ID: 2A8WM-KSM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 8 FCC ID: 2A8WM-KSM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 BT/WIFI ANT0 Page 3 of 8 FCC ID: 2A8WM-KSM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 WIFI ANT1 Page 4 of 8 FCC ID: 2A8WM-KSM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 8 FCC ID: 2A8WM-KSM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10 Page 6 of 8 FCC ID: 2A8WM-KSM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 11 Fig. 12 Page 7 of 8 FCC ID: 2A8WM-KSM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 13 Fig. 14 Page 8 of 8 FCC ID: 2A8WM-KSM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 15
Page 1 of 13 FCC ID: 2A8WM-KSM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Maximum Permissible Exposure Report 1. Product Information EUT : MINIPC Test Model : KSM1 Power Supply : Input: 12V2A For Adapter Input: 100-240V~, 50/60Hz, 0.8A For Adapter Output: 12V2000mA Hardware Version : / Software Version : / Bluetooth : Frequency Range : 2402MHz ~ 2480MHz Channel Number : 79 channels for Bluetooth V4.2(DSS) 40 channels for Bluetooth V4.2 (DTS) Channel Spacing : 1MHz for Bluetooth V4.2 (DSS) 2MHz for Bluetooth V4.2 (DTS) Modulation Type : GFSK, π/4-DQPSK, 8-DPSK for Bluetooth V4.2(DSS) GFSK for Bluetooth V4.2 (DTS) Bluetooth Version : V4.2 Antenna Description : FPC Antenna, 2.94dBi(Max.) 2.4G WLAN Frequency Range : 2412MHz~2462MHz Channel Spacing : 5MHz Channel Number : 11 Channels for 20MHz bandwidth (2412~2462MHz) 7 Channels for 40MHz bandwidth (2422~2452MHz) Modulation Type : IEEE 802.11b: DSSS (CCK, DQPSK, DBPSK) IEEE 802.11g: OFDM (64QAM, 16QAM, QPSK, BPSK) IEEE 802.11n: OFDM (64QAM, 16QAM, QPSK, BPSK) Antenna Description : Antenna 0: FPC Antenna, 2.94dBi(Max.) Antenna 1: FPC Antenna, 4.45dBi(Max.) 5.2G WLAN Frequency Range : 5180MHz~5240MHz Channel Number : 4 Channels for 20MHz bandwidth(5180MHz~5240MHz) 2 channels for 40MHz bandwidth(5190MHz~5230MHz) 1 channels for 80MHz bandwidth(5210MHz) Modulation Type : IEEE 802.11a/n/ac: OFDM (256QAM, 64QAM, 16QAM, QPSK, BPSK) Antenna Description : Antenna 0: FPC Antenna, 4.78dBi(Max.) Antenna 1: FPC Antenna, 0.93dBi(Max.) Page 2 of 13 FCC ID: 2A8WM-KSM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 5.8G WLAN Frequency Range : 5745MHz-5825MHz Channel Number : 5 channels for 20MHz bandwidth(5745MHz~5825MHz) 2 channels for 40MHz bandwidth(5755MHz~5795MHz) 1 channels for 80MHz bandwidth(5775MHz) Modulation Type : IEEE 802.11a/n/ac: OFDM (256QAM, 64QAM, 16QAM, QPSK, BPSK) Antenna Description : Antenna 0: FPC Antenna, 6.11dBi(Max.) Antenna 1: FPC Antenna, 3.63dBi(Max.) 2. Evaluation Method Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device whereby a distance of 0.2m normally can be maintained between the user and the device, and below RF Permissible Exposure limit shall comply with. In accordance with KDB447498D01 for Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the calculated/estimated, numerically modelled or measured field strengths or power density, is ≤ 1.0. The MPE ratio of each antenna is determined at the minimum test separation distance required by the operating configurations and exposure conditions of the host device, according to the ratio of field strengths or power density to MPE limit, at the test frequency. Either the maximum peak or spatially averaged results from measurements or numerical simulations may be used to determine the MPE ratios. Spatial averaging does not apply when MPE is estimated using simple calculations based on far-field plane-wave equivalent conditions. The antenna installation and operating requirements for the host device must meet the minimum test separation distances required by all antennas, in both standalone and simultaneous transmission operations, to satisfy compliance. 3. Limit 3. 1 Refer Evaluation Method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 447498 D01 General 1 RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: Mobile Devices Page 3 of 13 FCC ID: 2A8WM-KSM1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity 3. 2 Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100) * (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100) * (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequency in MHz *=Plane-wave equivalent power density 4. MPE Calculation Method Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna 5. Antenna Information EUT can only use antenn…
Text truncated - open the document above for the full version.
深圳市宝安区西乡街道润东晟工业区13栋4楼A A, floor 4, building 13, rundongsheng Industrial Zone, Xixiang street, Bao'an District, Shenzhen City, Guangdong Province WIFI Main ant WIFI Div ant 深圳市宝安区西乡街道润东晟工业区13栋4楼A A, floor 4, building 13, rundongsheng Industrial Zone, Xixiang street, Bao'an District, Shenzhen City, Guangdong Province WIFI Main antenna S11 深圳市宝安区西乡街道润东晟工业区13栋4楼A A, floor 4, building 13, rundongsheng Industrial Zone, Xixiang street, Bao'an District, Shenzhen City, Guangdong Province WIFI Div antenna S11 深圳市宝安区西乡街道润东晟工业区13栋4楼A A, floor 4, building 13, rundongsheng Industrial Zone, Xixiang street, Bao'an District, Shenzhen City, Guangdong Province WIFI&BT Main antenna Passive Test For 2.4Gwifi FreqEffiEffiGainGainUHISDHISMaxMin (MHz)(%)(dB)(dBi)(dBd)(%)(%)(dB)(dB) 240035.91-4.450.84-1.3119.11716.7930.84-17.66 241037.62-4.251.18-0.9720.38717.2341.18-17.02 242039.53-4.031.24-0.9121.8717.661.24-16.25 243041.86-3.781.42-0.7323.39418.4641.42-15.59 244046.28-3.351.46-0.6926.17720.0991.46-14.69 245050.05-3.011.7-0.4528.33821.7111.7-13.84 246052.07-2.831.63-0.5229.59422.4781.63-13.73 247054.05-2.671.92-0.2330.5723.4831.92-13.33 248058.75-2.312.310.1633.43325.3172.31-13 249062.6-2.032.910.7635.85526.7492.91-12.53 250060.8-2.162.940.7935.42425.3812.94-13.02 深圳市宝安区西乡街道润东晟工业区13栋4楼A A, floor 4, building 13, rundongsheng Industrial Zone, Xixiang street, Bao'an District, Shenzhen City, Guangdong Province 5GWIFI Passive Test For 5Gwifi FreqEffiEffiGainGainUHISDHISMaxMin (MHz)(%)(dB)(dBi)(dBd)(%)(%)(dB)(dB) 500048.37-3.154.111.9617.50630.8644.11-18.06 510046.44-3.334.192.0416.92329.5134.19-20.15 520048.61-3.134.782.6317.67830.9354.78-14.92 530046.87-3.294.32.1517.11729.7564.3-15.51 540062.17-2.065.453.321.57640.5935.45-14.97 550064.89-1.885.173.0223.85941.0295.17-14.81 560065.85-1.815.453.325.62840.2215.45-16.74 570072.09-1.425.163.0127.70944.3765.16-18 580072.77-1.386.113.9627.05445.7216.11-17.26 590066.95-1.745.112.9625.87141.0795.11-13.88 600071.36-1.475.333.1827.83343.5255.33-14.43 深圳市宝安区西乡街道润东晟工业区13栋4楼A A, floor 4, building 13, rundongsheng Industrial Zone, Xixiang street, Bao'an District, Shenzhen City, Guangdong Province WIFI Div Antenna Passive Test For 2.4Gwifi FreqEffiEffiGainGainUHISDHISMaxMin (MHz)(%)(dB)(dBi)(dBd)(%)(%)(dB)(dB) 240039.11-4.083.271.1215.7223.3943.27-18.58 241038.85-4.113.070.9215.61323.2393.07-17.29 242040.32-3.943.291.1415.75224.573.29-15.77 243041.99-3.773.371.2216.17125.8233.37-14.24 244045.68-3.43.871.7216.99328.6853.87-12.72 245048.21-3.174.051.917.74330.4694.05-11.34 246048.94-3.14.252.117.54131.4014.25-11.99 247048.92-3.14.162.0117.50831.4174.16-13.02 248051.59-2.874.452.318.24633.3454.45-13.37 249053.02-2.764.452.318.9934.034.45-13.57 250050.09-34.242.0917.8232.2684.24-12.85 深圳市宝安区西乡街道润东晟工业区13栋4楼A A, floor 4, building 13, rundongsheng Industrial Zone, Xixiang street, Bao'an District, Shenzhen City, Guangdong Province 5GWIFI Passive Test For 5G-WiFi FreqEffiEffiGainGainUHISDHISMaxMin (MHz)(%)(dB)(dBi)(dBd)(%)(%)(dB)(dB) 500036.11-4.420.68-1.4719.716.4150.68-13.71 510041.23-3.851.02-1.1322.84418.3841.02-13.24 520044.14-3.550.93-1.2224.09420.0470.93-14.34 530044.5-3.521.6-0.5524.5719.9321.6-15.27 540056.96-2.442.840.6932.19424.7622.84-13.6 550054.19-2.662.550.429.93824.252.55-16.01 560056.61-2.473.271.1230.51426.0943.27-15.88 570064.85-1.883.491.3432.25132.5953.49-16.44 580070.34-1.533.631.4835.6834.6553.63-14.64 590069.34-1.594.222.0734.21935.1184.22-11.33 600076.79-1.154.172.0239.08337.7044.17-11.29 深圳市宝安区西乡街道润东晟工业区13栋4楼A A, floor 4, building 13, rundongsheng Industrial Zone, Xixiang street, Bao'an District, Shenzhen City, Guangdong Province WIFI 深圳市宝安区西乡街道润东晟工业区13栋4楼A A, floor 4, building 13, rundongsheng Industrial Zone, Xixiang street, Bao'an District, Shenzhen City, Guangdong Province RF 2 1 3 5 4 6 深圳市宝安区西乡街道润东晟工业区13栋4楼A A, floor 4, building 13, rundongsheng Industrial Zone, Xixiang street, Bao'an District, Shenzhen City, Guangdong Province
Page 1 of 54 FCC ID: 2A8WM-KSM1 Report No.: LCSA100822005EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A RF Test Data for BT (Conducted Measurement) Product Name: MINIPC Test Model: KSM1 Environmental Conditions Temperature: 23.8 C Relative Humidity: 52.1% ATM Pressure: 100.0 kPa Test Engineer: Nick Peng Supervised by: Li Huan Page 2 of 54 FCC ID: 2A8WM-KSM1 Report No.: LCSA100822005EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.1 -20dB Bandwidth Condition Mode Frequency (MHz) Antenna -20 dB Bandwidth (MHz) Limit -20 dB Bandwidth (MHz) Verdict NVNT 1-DH5 2402 Ant1 0.943 N/A Pass NVNT 1-DH5 2441 Ant1 0.96 N/A Pass NVNT 1-DH5 2480 Ant1 0.953 N/A Pass NVNT 2-DH5 2402 Ant1 1.43 N/A Pass NVNT 2-DH5 2441 Ant1 1.429 N/A Pass NVNT 2-DH5 2480 Ant1 1.491 N/A Pass NVNT 3-DH5 2402 Ant1 1.482 N/A Pass NVNT 3-DH5 2441 Ant1 1.478 N/A Pass NVNT 3-DH5 2480 Ant1 1.479 N/A Pass Page 3 of 54 FCC ID: 2A8WM-KSM1 Report No.: LCSA100822005EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -20dB Bandwidth NVNT 1-DH5 2402MHz Ant1 -20dB Bandwidth NVNT 1-DH5 2441MHz Ant1 Page 4 of 54 FCC ID: 2A8WM-KSM1 Report No.: LCSA100822005EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -20dB Bandwidth NVNT 1-DH5 2480MHz Ant1 -20dB Bandwidth NVNT 2-DH5 2402MHz Ant1 Page 5 of 54 FCC ID: 2A8WM-KSM1 Report No.: LCSA100822005EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -20dB Bandwidth NVNT 2-DH5 2441MHz Ant1 -20dB Bandwidth NVNT 2-DH5 2480MHz Ant1 Page 6 of 54 FCC ID: 2A8WM-KSM1 Report No.: LCSA100822005EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -20dB Bandwidth NVNT 3-DH5 2402MHz Ant1 -20dB Bandwidth NVNT 3-DH5 2441MHz Ant1 Page 7 of 54 FCC ID: 2A8WM-KSM1 Report No.: LCSA100822005EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -20dB Bandwidth NVNT 3-DH5 2480MHz Ant1 Page 8 of 54 FCC ID: 2A8WM-KSM1 Report No.: LCSA100822005EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.2 Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Total Power (dBm) Limit (dBm) Verdict NVNT 1-DH5 2402 Ant1 2.81 21 Pass NVNT 1-DH5 2441 Ant1 2.96 21 Pass NVNT 1-DH5 2480 Ant1 2.39 21 Pass NVNT 2-DH5 2402 Ant1 0.62 21 Pass NVNT 2-DH5 2441 Ant1 1.04 21 Pass NVNT 2-DH5 2480 Ant1 0.5 21 Pass NVNT 3-DH5 2402 Ant1 0.78 21 Pass NVNT 3-DH5 2441 Ant1 1.27 21 Pass NVNT 3-DH5 2480 Ant1 0.73 21 Pass Page 9 of 54 FCC ID: 2A8WM-KSM1 Report No.: LCSA100822005EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs Power NVNT 1-DH5 2402MHz Ant1 Power NVNT 1-DH5 2441MHz Ant1 Page 10 of 54 FCC ID: 2A8WM-KSM1 Report No.: LCSA100822005EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power NVNT 1-DH5 2480MHz Ant1 Power NVNT 2-DH5 2402MHz Ant1 Page 11 of 54 FCC ID: 2A8WM-KSM1 Report No.: LCSA100822005EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power NVNT 2-DH5 2441MHz Ant1 Power NVNT 2-DH5 2480MHz Ant1 Page 12 of 54 FCC ID: 2A8WM-KSM1 Report No.: LCSA100822005EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Power NVNT 3-DH5 2402MHz Ant1 Power NVNT 3-DH5 2441MHz Ant1 Page 13 of 54 FCC ID: 2A8WM-KSM1 Report No.: LCSA100822005EA Shenzhen LCS Comp…
Text truncated - open the document above for the full version.
Page 1 of 37 FCC ID: 2A8WM-KSM1 Report No.: LCSA100822005EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FOR Shenzhen Anxin Taihe Technology Co., ltd MINIPC Test Model: KSM1 Prepared for : Shenzhen Anxin Taihe Technology Co., ltd Address : Room 201, No. 7, Baolongjun Industrial Zone, Jiuwo, Longping Community, Dalang Street, Longhua District, Shenzhen, China Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : October 08, 2022 Number of tested samples : 2 Sample No. : A100822005-1, A100822005-2 Serial number : Prototype Date of Test : October 08, 2022 ~ October 20, 2022 Date of Report : October 21, 2022 Page 2 of 37 FCC ID: 2A8WM-KSM1 Report No.: LCSA100822005EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15 C (15.247) Report Reference No. ................. : LCSA100822005EA Date of Issue ................................... : October 21, 2022 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure ........... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name .......................... : Shenzhen Anxin Taihe Technology Co., ltd Address ........................................... : Room 201, No. 7, Baolongjun Industrial Zone, Jiuwo, Longping Community, Dalang Street, Longhua District, Shenzhen, China Test Specification Standard.......................................... : FCC CFR 47 PART 15 C (15.247) Test Report Form No. ..................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. .................. : MINIPC Trade Mark ...................................... : KOOSMILE Test Model ...................................... : KSM1 Ratings ............................................ : Input: 12V2A For Adapter Input: 100-240V~, 50/60Hz, 0.8A For Adapter Output: 12V2000mA Result ........................................... : Positive Compiled by: Supervised by: Approved by: Vera Deng/ Administrator Cary Luo/ Technique principal Gavin Liang/ Manager Page 3 of 37 FCC ID: 2A8WM-KSM1 Report No.: LCSA100822005EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC -- TEST REPORT Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCSA100822005EA October 21, 2022 Date of issue Test Model.............................. : KSM1 EUT......................................... : MINIPC Applicant............................... : Shenzhen Anxin Taihe Technology Co., ltd Address................................... : Room 201, No. 7, Baolongjun Industrial Zone, Jiuwo, Longping Community, Dalang Street, Longhua District, Shenzhen, China Telephone............................... : / Fax.......................................... : / Manufacturer......................... : Shenzhe…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.00 mW |

Android Table
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Mini PC
Equipment Class
DTS - Digital Transmission System
Laptop
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Android tablet pc
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
NoteBook
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter