Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Complete Genomics, Inc. Hotline:+1 (888) 811-9644 E-mail: [email protected]; Address:2904 Orchard Parkway San Jose, CA 95134 Website: www.completegenomics.com RFID Module(EC-RF200-DLT7) The RFID module(model EC-RF200-DLT7) is prepared by Complete Genomics, Inc. Used to identify chip and kit serial numbers in Genetic Sequencer . It is consists of a RFID Controller and an antenna. Specifications describe: RFID controller Model:EC-RF200 Power supply: 9-30VDC, 1A Antenna Planar RFID antenna Model: EC-UHF-ANT-NF0003 Comply with GB/T 9410-2008; ANSI/IEEE Std149-1979 Size: 113mm × 23mm × 4.5mm Weight: 100g (excluding mounting bracket) Material: Engineering plastic ABS Connector type: SMA type RF coaxial connector Voltage standing wave ratio: ≤ 1.2:1 Gain: -15 dBi Polarization method: linear polarization Antenna impedance: 50 Ω Protection level: IP 65 Working frequency band: 902MHz~928MHz Support protocol: Supports EPC class Gen2 (ISO 18000-6-c), GB/T29768 Working mode: frequency hopping/fixed frequency; Output power: maximum 0.5W, configurable; Working temperature: -25 °C -+70 °C; Storage temperature: -40 °C -+85 °C Working humidity: 10% -95% RH without condensation; Safety regulations: Complete Genomics, Inc. Hotline:+1 (888) 811-9644 E-mail: [email protected]; Address:2904 Orchard Parkway San Jose, CA 95134 Website: www.completegenomics.com 1) Radio License: • EN 302 208; • FCC 47 FCR Part 15C; • SRRC; 2) EMC: EN 301 489; 3) Safety: EN 60 950; 4) ROHS certification: Passed relevant tests according to IEC 62321 standard; Interface definition: 1) POWER interface, external DC9-36V power adapter 2) LAN interface, RJ45 connector definition 8PIN RJ45 Interface Definition Pin Definition Description 1 TX+Transceive Data+ 2 TX - Traceive Data - 3 RX+Receive Data+ 4 NC suspended 5 NC suspended 6 RX - Receive Data - 7 NC suspended 8 NC suspended 3) ANT1, ANT2, ANT3 interfaces, SMA connectors, connecting antennas Complete Genomics, Inc. Hotline:+1 (888) 811-9644 E-mail: [email protected]; Address:2904 Orchard Parkway San Jose, CA 95134 Website: www.completegenomics.com FCC Statement This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: --Reorient or relocate the receiving antenna. --Increase the separation between the equipment and receiver. --Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. --Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. IC Note: This device complies with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme aux CNR exemptes de licence d’Innovation, Sciences et Développement économique Canada . Son fonctionnement est soumis aux deux conditions suivantes : (1) Ce dispositif ne peut causer d'interférences ; et (2) Ce dispositif doit accepter toute interférence , y compris les interférences qui peuvent causer un mauvais fonctionnement de l'appareil. Radiation Exposure Statement This equipment complies with FCC/IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. Cet équipement est conforme aux limites d'exposition aux radiations FCC/IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec une distance minimale de 20 cm entre le radiateur et votre corps. Complete Genomics, Inc. Hotline:+1 (888) 811-9644 E-mail: [email protected]; Address:2904 Orchard Parkway San Jose, CA 95134 Website: www.completegenomics.com Integration instructions for host product manufacturers according to KDB 996369 D03 OEM Manual v01 2.2 List of applicable FCC rules CFR 47 FCC PART 15 SUBPART C and RSS-247 isue2 has been investigated. It is applicable to the modular transmitter. 2.3 Specific operational use conditions This Modular Approval is limited to OEM installation for mobile and fixed applications only. The antenna installation and operating configurations of this transmitter, including any applicable source-based time averaging duty factor, antenna gain, and cable loss must satisfy MPE categorical Exclusion Requirements of 2.1091. 2.4 Limited module procedures This module will only use in Complete Genomics, Inc.’s host device only. We will retain control over the final installation of the modular such that compliance of the end product is assured. In such cases, an operating condition on the limit modular approval for the module must be only approved for use when installed in devices produced by a specific manuf…
Text truncated - open the document above for the full version.
Complete Genomics, Inc. 2904 ORCHARD PARKWAY SAN JOSE, CA 95134, US Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2023-7-13 U.S. Agent Designation Complete Genomics, Inc. acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2A92Z-ECRF200DLT7): Name and company of U.S. agent: Complete Genomics, Inc. Physical U.S. address of agent: 2904 ORCHARD PARKWAY SAN JOSE, CA 95134, US FRN of U.S. agent: 0033289026 Email address of U.S. agent: [email protected] Complete Genomics, Inc. acknowledges their obligation to accept service of process on behalf of Complete Genomics, Inc.. Complete Genomics, Inc. with the FRN [0033289026] accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. Sincerely, Signature Miaoli Yan Manager Complete Genomics, Inc. Signature Miaoli Yan Manager Complete Genomics, Inc. 48_[mo del] US_Agent_2.911(d)(7) - U, V0 5
FCC ID: 2A92Z-ECRF200DLT7 IC: 29863-ECRF200DLT7
FCC ID: 2A92Z-ECRF200DLT7 IC: 29863-ECRF200DLT7
RF Exposure evaluation FCC ID: 2A92Z-ECRF200DLT7 Exposure category: General population/uncontrolled environment EUT Type: Production Unit Device Type: Mobile Device 1. Reference According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to §1.1310 and §2.1091 RF exposure is calculated. KDB447498 D01: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies 2. Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100) * (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100) * (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequency in MHz *=Plane-wave equivalent power density 3. MPE Calculation Method Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna 4. Antenna Information The device can use antennas certificated as follows provided by manufacturer; Type Antenna type Frequency Range Antenna Gain EC-UHF-ANT-NF0003 External Planar RFID antenna 840-960MHz -8.02dBi 5. Conducted power and Manufacturing Tolerance RFID Channel Channel 01 Channel 27 Channel 52 Target (dBm) 15.0 15.0 15.0 Tolerance ±(dB) 1.0 1.0 1.0 6. Standalone MPE Result As declared by the Applicant, the EUT is a wireless device used in a fix application, at least 20 cm from any body part of the user or nearby persons; from the maximum EUT RF output power, the minimum separation distance, r =20cm, as well as the max. gain of the used antenna, the RF power density can be obtained. Modulation Type Max tune up power tolerance(dBm) Max Output power to antenna (mW) Antenna Gain (Numeric) Power Density at R=20cm (mW/cm2) Limit (mW/cm2) Result ASK 16 39.8107 0.1578 0.0012 0.6185 Pass 7. Conclusion The measurement results comply with the FCC Limit per 47 CFR 2.1091 for the uncontrolled RF Exposure of mobile device. ----------------THE END OF REPORT---------------
ReportNo.:RFI-LAB-RF-202306-FF06 QP030-E41 Page1of10 TestingReport CustomerName:EC-LINKAutomation(Shenzhen)Co.Ltd. ProductName:PlanarRFIDantenna SampleModel:EC-UHF-ANT-NF0003 ReferenceStandard:GB/T9410-2008;ANSI/IEEEStd149-1979 IssueDate:2023.6.9 Engineer:Date: Auditor:Date: Approver:Date: ReportNo.:RFI-LAB-RF-202306-FF06 QP030-E41 Page2of10 Version VersionNo.DateDescriptionFormulateApproval A02023.6.9Forthefirsttime,formulateZkrisEason Contents 1.GeneralInformation.........................................................................................................................3 1.1Generalinformationoftestinginstitutions...........................................................................3 1.2Testingprinciple...................................................................................................................3 1.3Testequipment......................................................................................................................4 1.4Testenvironment...................................................................................................................4 1.5Statement..............................................................................................................................4 2.SampleInformation.........................................................................................................................5 2.1Clientinformation.................................................................................................................5 2.2DescriptionofEUT(S)..........................................................................................................5 2.3EUTappearance....................................................................................................................6 2.4EUTsetupphotooffreespaceOTAtesting.........................................................................6 3.TestResults.....................................................................................................................................7 3.1Teststandard.........................................................................................................................7 3.2Testuncertainty.....................................................................................................................7 3.3Testdata................................................................................................................................8 3.3.1VSWRparameters.....................................................................................................8 3.3.2VSWRdata................................................................................................................8 3.3.3Typicalfreespaceefficiencyandgain......................................................................8 3.3.4Typicalfreespaceradiationpattern...........................................................................9 (Thefollowingisblank)..............................................................................................................10 ReportNo.:RFI-LAB-RF-202306-FF06 QP030-E41 Page3of10 1.GeneralInformation 1.1Generalinformationoftestinginstitutions Name ShenzhenRFI-LABCommunicationTechnologyCo.,Ltd. Address 10/FA,LingyunBld,LiufangRd,BaoanDistrict,SZ Tel 13682621346 E-mail [email protected] Equipment AlltheequipmentusedinthereportisfixedinZoneB,WestSideof1/F,Building1, TingweiIndustrialPark,No.6LiufangRoad,Bao'anDistrict,Shenzhen 1.2Testingprinciple ReportNo.:RFI-LAB-RF-202306-FF06 QP030-E41 Page4of10 1.3Testequipment EquipmentModelNo.SerialNo.Manufacturer Calibration date Next calibration date OTATest System RayZone-5000 RFI-LAB-RF -D00 GTS2023.3.142025.3.13 Network Analyzer E5071C RFI-LAB-RF -D01 KEYSIGHT2023.5.112024.5.10 Network Analyzer E5071C RFI-LAB-RF -C02 KEYSIGHT2023.5.112024.5.10 1.4Testenvironment Temperature 24.2°C Humidity 59%RH Pressure 100.15kPa 1.5Statement (1)Thetestresultsinthereportareonlyapplicabletothetestedsamplesandthetestedsamples workundertheenvironmentdescribedinthereport. (2)OnlyShenzhenRFI-LABCommunicationTechnologyCo.,Ltd.havetherighttomodifythe report,andthemodificationinformationshallbeannotatedintherevisionform. (3)Anyobjectiontothisreportshallberaisedwithin30daysafterformalconfirmationofthe report. (4)Thisreportisinvalidifthereisanyevidencethatthesampleinformationprovidedisfalsified. (5)Thereportisinvalidwithoutthesignatureoftheauditorandapprover. ReportNo.:RFI-LAB-RF-202306-FF06 QP030-E41 Page5of10 2.SampleInformation 2.1Clientinformation Name EC-LINKAutomation(Shenzhen)Co.Ltd. Address Room2206,BlockB,ShixiaXintianCentury,BusinessCenter,Futian District,ShenzhenCity,China Contacts / Tel / E-mail / Manufacturer / Manufacturer Address / 2.2DescriptionofEUT(S) ProductName PlanarRFIDantenna SampleModel EC-UHF-ANT-NF0003 AntennaSize / SerialNo. / AntennaType PCBAntenna TestItem VSWR;Antennagain;Efficiency;Radiationpattern FrequencyRange 840-960MHz ReceivedDate 2023.6.8 TestDate 2023.6.8 Remark / ReportNo.:RFI-LAB-RF-202306-FF06 QP030-E41 Page6of10 2.3EUTappearance 2.4EUTsetupphotooffreespaceOTAtesting Planform Frontview ReportNo.:RFI-LAB-RF-202306-FF06 QP030-E41 Page7of10 3.TestResults 3.1Teststandard NameParameterMethodStandardno. Mobile communication antenna Antennagain Genericspecification forantennasusedinthe mobilecommunications GB/T 9410-2008 Radiationpattern VSWR Antenna Radiationefficiency IEEEStandardTest ProceduresforAntennas ANSI/IEEEStd 149-1979 Gainanddirectivity 3.2Testuncertainty TheuncertaintywascalculatedonthebasisoftheGUMpublishedbyISO,usingthe inclusionfactorofK=2andthe95%confidenceleveltoexpresstheextended uncertainty. ItemUncertainty VSWR±0.3 Antennagain±0.72dB Radiationefficiency±0.72dB ReportNo.:RFI-LAB-RF-202306-FF06 QP030-E41 Page8of10 3.3Testdata 3.3.1VSWRparameters 3.3.2VSWRdata 3.3.3Typicalfreespaceefficiencyandgain Frequency/MHz 840900960 VSWR 10.1926.961229.488 Frequency/MHz 840850860870880890900910920930940950960 PeakGain/dBi -20.86…
Text truncated - open the document above for the full version.
Shenzhen CTL Testing Technology Co., Ltd. Tel: +86-755-89486194 E-mail: [email protected] TEST REPORT FCC PART 15 SUBPART C 15.247 & RSS-247 Report Reference No. ................ : CTL2304242042-WF Compiled by: ( position+printed name+signature) Happy Guo (File administrators) Tested by: ( position+printed name+signature) Gary Gao (Test Engineer) Approved by: ( position+printed name+signature) Ivan Xie (Manager) Product Name ............................ : RFID Module Model(HVIN) ............................... : EC-RF200-DLT7 List Model(HVIN) ........................ : N/A Trade Mark .................................. : N/A FCC ID ........................................ : 2A92Z-ECRF200DLT7 IC ................................................. : 29863-ECRF200DLT7 Applicant’s name ....................... : Complete Genomics, Inc. Address of applicant ................. : 2904 ORCHARD PARKWAY SAN JOSE, CA 95134 Test Firm ..................................... : Shenzhen CTL Testing Technology Co., Ltd. Address of Test Firm ................. : Floor 1-A, Baisha Technology Park, No.3011, Shahexi Road, Nanshan District, Shenzhen, China 518055 Test specification ....................... : Standard ...................................... : 47 CFR FCC Part 15 Subpart C 15.247 & RSS-247 Issue 2, February 2017 TRF Originator ............................. : Shenzhen CTL Testing Technology Co., Ltd. Master TRF .................................. : Dated 2011-01 Date of receipt of test item ........ : April 26, 2023 Date of sampling ........................ : April 27, 2023 Date of Test Date ........................ : April 27, 2023- July 12, 2023 Date of Issue .............................. : July 12, 2023 Result ......................................... : Pass Shenzhen CTL Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTL Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTL Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. V1.0 Page 2 of 46 Report No.: CTL2304242042-WF TEST REPORT Test Report No.: CTL2304242042-WF July 12, 2023 Date of issue Equipment under Test : RFID Module Sample No. : CTL230424204-2-S001(Normal sample) CTL230424204-2-S002(Engineer sample) Model (HVIN) : EC-RF200-DLT7 Listed Models(HVIN) : N/A Applicant : Complete Genomics, Inc. Address : 2904 ORCHARD PARKWAY SAN JOSE, CA 95134 Manufacturer : Complete Genomics, Inc. Address : 2904 ORCHARD PARKWAY SAN JOSE, CA 95134 Test result Pass * * In the configuration tested, the EUT complied with the standards specified page 5. The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the issuing testing laboratory. V1.0 Page 3 of 46 Report No.: CTL2304242042-WF ** Modified History ** Revisions Description Issued Data Report No. Remark Version 1.0 Initial Test Report Release 2023-07-12 CTL2304242042-WF Tracy Qi V1.0 Page 4 of 46 Report No.: CTL2304242042-WF Table of Contents Page 1. SUMMARY ................................................................................................................................... 5 1.1. TEST STANDARDS ............................................................................................................ 5 1.2. Test Description .................................................................................................................. 5 1.3. Test Facility ......................................................................................................................... 6 1.4. Statement of the measurement uncertainty ........................................................................ 6 2. GENERAL INFORMATION ........................................................................................................... 8 2.1. Environmental conditions .................................................................................................... 8 2.2. General Description of EUT ................................................................................................ 8 2.3. Special Accessories ............................................................................................................ 8 2.4. Description of Test Modes and Test Frequency ................................................................... 9 2.5. Equipments Used during the Test ....................................................................................... 9 2.6. Related Submittal(s) / Grant (s) ........................................................................................ 10 2.7. Modifications .................................................................................................................... 10 3. TEST CONDITIONS AND RESULTS .......................................................................................... 11 3.1. Conducted Emissions Test ................................................................................................ 11 3.2. Radiated Emissions and Band Edge ................................................................................. 14 3.3. Maximum Conducted Output Power ................................................................................. 25 3.4. 20dB Bandwidth ............................................................................................................... 27 3.5. Frequency Separation ...................................................................................................... 29 3.6. Number of hopping frequency ........................................................................................... 31 3.7. Time Of Occupancy(Dwell Time) ....................................................…
Text truncated - open the document above for the full version.
FCC ID: 2A92Z-ECRF200DLT7 IC: 29863-ECRF200DLT7
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 902.25 MHz - 927.75 MHz | 37.50 mW |

RFID Module
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Genetic Sequencer
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter