Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
For Research Use Only. Complete Genomics, Inc. DNBSEQ-G800RS User Manual About this manual This manual is applicable to Genetic Sequencer (DNBSEQ-G800RS). The manual version is 1.0 and the software version is V1. This manual and the information contained herein are proprietary to Complete Genomics, Inc. (hereinafter referred to as CG), and are intended solely for the contractual use of its customers in the use of the products described herein and for no other purpose. This manual and its content shall not be reprinted, reproduced, modified, distributed, or disclosed to others, in whole or in part, without prior written consent from CG. CG makes no commitment to this manual, including (but not limited to) any special purpose commercial and any reasonable implied warranties. CG has taken measures to ensure the correctness of this manual. However, CG is not responsible for any missing parts of the manual, and reserves the right to revise the manual and modify the device, so as to improve the reliability, performance or design. Figures in this manual are for illustrative purpose only. The content might be slightly different from the device. For the most up to date details, refer to the device purchased. DNBSEQ TM is a trademark of CG or its affiliates in U.S. and/or other countries. Intelยฎ and Xeonยฎ are trademarks of Intel Corporation or its subsidiaries in the U.S. and/or other countries. Qubit TM is the trademark of Thermo Fisher Scientific, or its subsidiaries. ProClin TM is a trademark of the Dow Chemical Company (Dow) or an affiliated company of Dow. Other names and trademarks mentioned in this manual are the property of their respective companies and subsidiaries. ยฉ2023 Complete Genomics, Inc. All rights reserved. Revision history DateVersion Initial releaseMarch 15 , 20231.0 Contents I Contents Safety 1 Conventions used in this guide 2 General safety 2 Electrical safety 4 Mechanical safety 4 Components safety 4 Biological safety 5 Symbols 5 Packaging 5 Device 6 Label 7 User manual 8 Device overview 9 Intended use 10 Working principle 10 Sequencer overview 11 Structural composition 11 Basic components 12 Control software 20 Laboratory requirements 27 Site requirements 28 Network requirements 29 Device requirements 30 Power supply requirements 31 Peripheral device requirements 32 Sequencing 33 ContentsManual II Workflow 34 Preparing DNBs 34 Preparing the reagent cartridge and flow cell 35 Reagent cartridge and sequencing flow cell 35 Cleaning cartridge and washing flow cell 35 Preparing the device 35 Powering the device on 35 Logging in to the control software 36 Performing pre-run checks 36 Performing an auto wash 37 Loading the flow cell 37 Cleaning the flow cell satge 37 Loding new flow cell 37 Loading the sequencing reagent cartridge 39 Preparing the reagent cartridge compartment 39 Loding the reagent cartridge 40 Loading DNBs 40 Reviewing parameters 42 Performing sequencing run 42 Performing a regular wash 44 Disposing of the sequencing reagent cartridge and flow cell 44 (Optional) Powering the device off 45 Device maintenance 47 Service plan 48 Daily maintenance 48 Maintaining the power cord 48 Checking and cleaning the cooling fan 48 ContentsManual III Flow cell stage and flow cell maintenance 49 Introduction of flow cell stage and flow cell 49 Cleaning the flow cell stage and flow cell 50 Cleaning sealing gasket 51 Sequencer maintenance 51 Wash 51 Weekly maintenance 56 Monthly maintenance 57 Annual maintenance 58 Maintaining the software 58 FAQs 58 Storage and transportation 60 Disposal of the device 60 Device specifications 61 Compliance information 63 Manufacturer information 65 Order information 67 Acronyms and abbreviations 69 Index 71 ---This page is intentionally left blank.--- 1 01 Safety This chapter describes basic safety information about the device. Carefully read and understand the information before use to ensure correct operations, best performance, and personnel safety. Keep this guide at hand for reference at any time. SafetyConventions used in this guide 2 Conventions used in this guide The following table describes conventions that are used in this guide: ItemDescription shall Means compliance with a requirement or it is mandatory for compliance with this document should Means compliance with a requirement but it is not mandatory for compliance with this document mayUsed to describe possibility or probability canUsed to describe permission and capability mustUsed to express a constraint BoldfaceIndicates the printings and on-screen characters on the device General safety DANGER y Ensure that the device is operated under the conditions specified in this guide. Otherwise, it may cause altered experimental results, device malfunction, or even personal injury. y Ensure that the components of the device are completely installed before operation. Otherwise, it may cause in personal injury. y A laser is installed in the device. Laser radiation can cause eye injury and skin burns. Before performing a sequencing run, ensure that the flow cell compartment door of the device is closed. Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. y Maintain the device by following the instructions described in this manual to ensure best performance. Otherwise, it might result in device malfunction or even personal injury. y Do not operate the device in the presence of flammable or explosive liquids, vapors, or gases. Otherwise, it might result in device damage, or even personal injury. y Do not operate the device during maintenance or transportation. SafetyGeneral safety 3 WARNING y Only CG Technical Support or qualified and trained personnel can unpack, install, move, debug and maintain the device. Incorrect operations can cause altered experimental results or damage to the device. y Do not move the device after CG Technical Support have installed and debugged the device. Unauthorized moves of thโฆ
Text truncated - open the document above for the full version.
SequencingWorkfow 34 Workfow Circular ssDNA Maintenance Preparing the device Preparing DNBs Loading DNBs Loading the flow cell Performing a sequencing run Loading the sequencing reagent cartridge Preparing the reagent cartridge and flow cell y Chemicals in reagents and waste might cause personal injury through contact with the skin, eyes, or mucosa. Follow the safety standards of your laboratory and wear protective equipment (such as a laboratory coat, protective glasses, mask, gloves, and shoe covers) when using the device. y If you accidentally splash reagents or waste liquids on the skin or into eyes, immediately flush the affected area with large amounts of water, and then seek medical aid. y When disposing of expired reagents, waste liquids, waste DNBs, and consumables, comply with local regulations. Preparing DNBs It is recommended to use the library preparation system or reagent kit of the manufacturer to prepare DNBs. For details, refer to the relevant reagent kit user manual. SequencingPreparing the reagent cartridge and fow cell 35 Preparing the reagent cartridge and fow cell CAUTION y Use only the reagent cartridge and flow cell of the manufacturer for the sequencing process. You can purchase them as needed from the authorized sales representatives. y If the sequencing reagent cartridge is not used immediately, store the cartridge at appropriate temperatures as required. Thaw the cartridge thoroughly before performing sequencing. Reagent cartridge and sequencing fow cell Remove the sequencing reagent cartridge from storage and prepare it for sequencing. For details, refer to relevant reagent kit user manual. After preparing the sequencing reagent cartridge, place it at 2 ยฐC to 8 ยฐC (36 ยฐF to 46 ยฐF ). If the sequencing reagent cartridge is not used immediately, store the cartridge at appropriate temperatures as required. Thaw the cartridge thoroughly before performing a sequencing run. Cleaning cartridge and washing fow cell Cleaning cartridges are delivered with the device for wash procedures. A used flow cell without physical damage can be used as washing flow cell. About how to prepare the cleaning cartridge, refer to Cleaning cartridge and external cleaning module introduction on Page 52. About how to perform a wash manually, refer to Regular wash on Page 52. Preparing the device Powering the device on Perform the following steps: 1. Connect one end of the power cord to the power port of the device, and the other end to the mains supply. 2. (Optional) If a UPS is prepared, connect the one end of the UPS power cord to the device, and the other end to the mains supply. SequencingPreparing the device 36 3. Turn the power switch of the device to theposition. After you power the device on, self-t est begins. Logging in to the control software You can perform the sequencing and wash procedures only after you log in to the control software. Perform the following steps: 1. Power the device on. 2. Log in to the computer with the password that is provided by the manufacturer. 3. Select in the main interface. 4. Log in to the control software with the user name and password. Performing pre-run checks Before each sequencing run, perform the following checks: y Check whether the remaining space of storage drive is greater than 4.6 TB. If the remaining space is insufficient, clear history data according to Reviewing parameters on Page 42 . y Check the waste container, and solve the problem before sequencing. 1) If the waste level reaches 80% of the maximum volume of the waste container, empty the waste container. For details, refer to Maintaining the waste container on Page 56 . 2) If the waste container icon turns to , empty the waste container. For details, refer to Maintaining the waste container on Page 56 . 3) If the float of the waste level sensor is not properly placed at the lower position of the waste container, clean and move the sensor to the lower position. 4) If any problem occurs other than those mentioned above, restart the sequencer control software. 5) If the problem persists, contact CG Technical Support. y Check whether the environmental temperature and humidity meet the requirements mentioned in Device specifications on Page 61, and ensure that the temperature fluctuates within the specified range throughout the sequencing, and the humidity is constant. SequencingLoading the fow cell 37 Performing an auto wash Before each sequencing run, it is required to perform an auto wash. For details, refer to Auto wash on Page 51. Loading the fow cell Cleaning the fow cell satge The canned air duster can be replaced by a clean cloth moistened with 75% ethanol to remove dust in the following steps. Perform the following steps: 1. Open the flow cell compartment door. 2. Press both sides of the flow cell, and press the flow cell attachment button with the other hand. 3. After the vacuum is released, remove the flow cell from the stage. 4. Use a canned air duster to remove the dust on the flow cell stage and the back of the flow cell. Figure 11 Cleaning the flow cell stage If there are impurities on the stage surface, gently wipe the surface with wet dust- free paper to ensure that the flow cell can be held properly. Loding new fow cell Perform the following steps: 1. Take out a new flow cell. SequencingLoading the fow cell 38 2. There are two alignment holes on the left side and one hole on the right side. The label is on the right. Hold the edge of the flow cell with both hands. Figure 12 Loading the flow cell 3. Align the holes on the flow cell with the locating pins on the flow cell stage. Gently slide the flow cell at an angle of 45 degrees to the upper left corner to keep the flow cell aligned with the pin. 4. Press the flow cell attachment button. Press the left and right sides of the flow cell on the stage at the same time to ensure that the flow cell is properly seated on the stage. The flow cell is fragile, please operate with care. 5. Use a canned air duster to remove theโฆ
Text truncated - open the document above for the full version.
Complete Genomics, Inc. * the applicant must designate a contact located in the United States for purposes of acting as the applicantโs agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter 4/19/2023 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: 2A92ZDNBSEQG800R Per section 2.911(d)(7) of the FCC rules, Complete Genomics, Inc. (โthe applicantโ) certifies that the equipment for which authorization is sought is designated to the following U.S. agent* for service of process: Company Name: Complete Genomics, Inc. Physical U.S. Company Address: 2904 ORCHARD PARKWAY SAN JOSE, CA 95134, US Agent name: Miaoli Yan Agent Email Address : [email protected] FRN: 0033289026 The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Agent Signed (if different to Applicant ): Signed: Signed: Printed name: Miaoli Yan Printed name: Miaoli Yan Title: Manager Title: Manager Company Name: Complete Genomics, Inc. Company Name: Complete Genomics, Inc. Date: 4/19/2023 Date: 4/19/2023
Complete Genomics, Inc. Covered Equipment Certification Attestation Letter 4/19/2023 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: 2A92ZDNBSEQG800R Complete Genomics, Inc. (โthe applicantโ) certifies that the equipment for which authorization is sought is not โcoveredโ equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List , the applicant should include an explanation on why the equipment is not โcoveredโ equipment. Complete Genomics, Inc. (โthe applicantโ) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing โcoveredโ equipment. Signature: Name: Miaoli Yan Company: Complete Genomics, Inc. Address: 2904 ORCHARD PARKWAY SAN JOSE, CA 95134, US Phone: +86 18998996969 Fax: / E-Mail: [email protected]
Complete Genomics, Inc. Date: 2023.04.19 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2A92ZDNBSEQG800R Product Name: Genetic Sequencer Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: (List here the documents for which you are seeking confidentiality โ for example ...) โข Schematics โข Block Diagram โข Operation Description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. Signature: Name: Miaoli Yan Company: Complete Genomics, Inc. Address: 2904 ORCHARD PARKWAY SAN JOSE, CA 95134, US Phone: +86 18998996969 Fax: / E-Mail: [email protected]
CTC Laboratories, Inc. 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China Tel: +86-755- 27521059 Fax: +86-755- 27521011 Http://www.sz-ctc.org.cn Page 1 of 5 External Photographs Page 2 of 5 Page 3 of 5 Page 4 of 5 Page 5 of 5
CTC Laboratories, Inc. 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China Tel: +86-755- 27521059 Fax: +86-755- 27521011 Http://www.sz-ctc.org.cn Page 1 of 1 Label Label Location 1.
CTC Laboratories, Inc. 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China Tel: +86-755- 27521059 Fax: +86-755- 27521011 Http://www.sz-ctc.org.cn Page 1 of 13 Internal Photographs Page 2 of 13 Page 3 of 13 Page 4 of 13 Page 5 of 13 Rongke Server Rongke Server Page 6 of 13 Guoxin Server Guoxin Server Page 7 of 13 Fenghuo Server Fenghuo Server Page 8 of 13 RFModule 1 Page 9 of 13 RFModule2 Page 10 of 13 Page 11 of 13 Antenna Page 12 of 13 Page 13 of 13
CTC Laboratories, Inc. 1- 2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China Tel: +86-755- 27521059 Fax: +86-755- 27521011 Http://www.sz-ctc.org.cn CTC Laboratories, Inc. 1- 2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www. s z-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the Peopleโs Republic of China : yz.cnca.cn Maximum Permissible Exposure Evaluation FCC ID: 2A92ZDNBSEQG800R According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) Radiation as specified in ยง1.1307(b) EUT Specification Product Name: Genetic Sequencer Trade Mark: MGI Model/Type reference: DNBSEQ-G800RS Listed Model(s): / Frequency band (Operating) 902.75MHz ~ 927.25MHz Device category Portable (<5mm separation) Mobile (>20cm separation) Fixed (>20cm separation) Others ___ Exposure classification Occupational/Controlled exposure (S=5mW/cm2) General Population/Uncontrolled exposure (S=1mW/cm2) Antenna diversity Single antenna Multiple antennas Tx diversity Rx diversity Tx/Rx diversity Antenna gain: -0.3dBi Max Evaluation applied MPE Evaluation SAR Evaluation Limits for Maximum Permissible Exposure (MPE) Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density(mW/cm 2 ) Average Time (A) Limits for Occupational/Control Exposures 300-1500 -- -- F/300 6 1500-100000 -- -- 5 6 (B) Limits for General Population/Uncontrol Exposures 300-1500 -- -- F/1500 30 1500-100000 -- -- 1 30 Page 2 of 2 Report No.: CTC20230734E04 CTC Laboratories, Inc. 1- 2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the Peopleโs Republic of China : yz.cnca.cn Friis transmission formula: Pd=(Pout*G)\(4*pi*R 2 ) Where Pd= Power density in mW/cm 2 Pout= output power to antenna in mW G= gain of antenna in linear scale Pi= 3.1416 R= distance between observation point and center of the radiator in cm Pd the limit of MPE 1mW/cm 2 . I f we know the maximum gain of the antenna and total power input to the antenna, through the calculation, We will know the distance where the MPE limit is reached. Measurement Result Band Frequency (MHz) Antenna Gain (dBi) Maximum Power (dBm) Tune up tolerance (dBm) Max. Tune up Power (dBm) Power Density at 20cm (mW/cm2) Limit (mW/cm2) RF ID 902.75 -0.318.00 18ยฑ1 19 0.01475 0.602 915.25 -0.317.80 18ยฑ1 19 0.01475 0.602 927.25 -0.317.65 18ยฑ1 19 0.01475 0.602 Modu le 1 and m odule 2 transmit simultaneously Module 1 at 20cm (mW/cm 2 ) Module 2 at 20cm (mW/cm 2 ) Total Power density at 20cm(mW/cm 2 ) Limit (mW/cm2) 0.01475 0.01475 0.0295 0.602 Note: For a more detailed features description, Please refer to the RF Test Report. **********************THE END**********************
CTC Laboratories, Inc. 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China Tel: +86-755- 27521059 Fax: +86-755- 27521011 Http://www.sz-ctc.org.cn TEST REPORT Report No. ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท: CTC20230734E03 FCC IDยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท: 2A92ZDNBSEQG800R ICยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท: 29863-DNBSEQG800R Applicantยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท: Complete Genomics, Inc. Addressยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท: 2904 ORCHARD PARKWAY SAN JOSE, CA 95134, US Manufacturerยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท: Complete Genomics, Inc. Addressยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท: 2904 ORCHARD PARKWAY SAN JOSE, CA 95134, US Product Nameยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท: Genetic Sequencer Trade Markยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท: MGI Model/Type referenceยทยทยทยทยทยทยทยทยทยทยทยทยท: DNBSEQ-G800RS Listed Model(s) ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท: / Standardยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท: FCC CFR Title 47 Part 15 Subpart C Section 15.247 RSS 247 Issue 2 Date of receipt of test sample...: Mar. 23, 2023 Date of testing.......................: Mar. 24, 2023 ~ Apr. 23, 2023 Date of issue.........................: Apr. 23, 2023 Result.................................: PASS Compiled by: (Printed name+signature) Terry Su Supervised by: (Printed name+signature) Eric Zhang Approved by: (Printed name+signature) Totti Zhao Testing Laboratory Name......: CTC Laboratories, Inc. Address...............................: 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China This test report may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product endorsement by CTC. The test results in the report only apply to the tested sample. The test report shall be invalid without all the signatures of testing engineers, reviewer and approver. Any objections must be raised to CTC within 15 days since the date when the report is re- ceived. It will not be taken into consideration beyond this limit. The test report merely correspond to the test sample. Page 2 of 61 Report No.: CTC20230734E03 CTC Laboratories, Inc. 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Ac- creditation Administration of the Peopleโs Republic of China : yz.cnca.cn Table of Contents Page 1. TEST SUMMARY ............................................................................................................................................ 3 1.1. T EST STANDARDS ................................................................................................................................................. 3 1.2. R EPORT VERSION ................................................................................................................................................. 3 1.3. T EST DESCRIPTION ............................................................................................................................................... 4 1.4. T EST FACILITY ...................................................................................................................................................... 5 1.5. M EASUREMENT UNCERTAINTY ............................................................................................................................... 5 1.6. E NVIRONMENTAL CONDITIONS ............................................................................................................................... 6 2. GENERAL INFORMATION ............................................................................................................................... 7 2.1. C LIENT INFORMATION ........................................................................................................................................... 7 2.2. G ENERAL DESCRIPTION OF EUT ............................................................................................................................. 7 2.3. A CCESSORY EQUIPMENT INFORMATION .................................................................................................................... 8 2.4. O PERATION STATE ................................................................................................................................................ 9 2.5. M EASUREMENT INSTRUMENTS LIST ...................................................................................................................... 10 3. TEST ITEM AND RESULTS .............................................................................................................................. 12 3.1. C ONDUCTED EMISSION ....................................................................................................................................... 12 3.2. R ADIATED EMISSION ........................................................................................................................................... 19 3.3. B AND EDGE EMISSIONS (RADIATED) ...................................................................................................................... 33 3.4. B AND EDGE AND SPURIOUS EMISSIONS (CONDUCTED) ............................................................................................. 38 3.5. 20DB BANDWIDTH ............................................................................................................................................ 46 3.6. C HANNEL SEPARATION ........................................................................................................................................ 49 3.7. N UMBER OF HOPPING CHANNEL .......................................................................................................................... 51 3.8. D WELL TIME .....................................โฆ
Text truncated - open the document above for the full version.
ReportNo.:RFI-LAB-RF-202304-DD12 QP030-E41 Page1of9 TestingReport CustomerName:EC-LINKAutomation(Shenzhen)Co.Ltd. ProductName:PlanarRFIDantenna SampleModel:EC-UHF-ANT-NF0013 ReferenceStandard:GB/T9410-2008;ANSI/IEEEStd149-1979 IssueDate:2023.4.18 Engineer:Date: Auditor:Date: Approver:Date: ReportNo.:RFI-LAB-RF-202304-DD12 QP030-E41 Page2of9 Version VersionNo.DateDescriptionFormulateApproval A02023.4.18Forthefirsttime,formulateZkrisEason Contents 1.GeneralInformation.........................................................................................................................3 1.1Generalinformationoftestinginstitutions...........................................................................3 1.2Testingprinciple...................................................................................................................3 1.3Testequipment......................................................................................................................4 1.4Testenvironment...................................................................................................................4 1.5Statement..............................................................................................................................4 2.SampleInformation.........................................................................................................................5 2.1Clientinformation.................................................................................................................5 2.2DescriptionofEUT(S)..........................................................................................................5 2.3EUTappearance....................................................................................................................6 2.4EUTsetupphotooffreespaceOTAtesting.........................................................................6 3.TestResults......................................................................................................................................7 3.1Teststandard.........................................................................................................................7 3.2Testuncertainty.....................................................................................................................7 3.3Testdata................................................................................................................................7 3.3.1Typicalfreespaceefficiencyandgain......................................................................7 3.3.2Typicalfreespaceradiationpattern...........................................................................8 ๏ผThefollowingisblank๏ผ................................................................................................................9 ReportNo.:RFI-LAB-RF-202304-DD12 QP030-E41 Page3of9 1.GeneralInformation 1.1Generalinformationoftestinginstitutions Name ShenzhenRFI-LABCommunicationTechnologyCo.,Ltd. Address 10/FA,LingyunBld,LiufangRd,BaoanDistrict,SZ Tel 13682621346 E-mail [email protected] Equipment AlltheequipmentusedinthereportisfixedinZoneB,WestSideof1/F,Building1, TingweiIndustrialPark,No.6LiufangRoad,Bao'anDistrict,Shenzhen 1.2Testingprinciple ReportNo.:RFI-LAB-RF-202304-DD12 QP030-E41 Page4of9 1.3Testequipment EquipmentModelNo.SerialNo.Manufacturer Calibration date Next calibration date OTATest System RayZone-5000 RFI-LAB-RF -D00 GTS2023.3.142025.3.13 Network Analyzer E5071C RFI-LAB-RF -D01 KEYSIGHT2022.5.132023.5.12 1.4Testenvironment Temperature 24.5ยฐC Humidity 58%RH Pressure 100.16kPa 1.5Statement (1)Thetestresultsinthereportareonlyapplicabletothetestedsamplesandthetestedsamples workundertheenvironmentdescribedinthereport. (2)OnlyShenzhenRFI-LABCommunicationTechnologyCo.,Ltd.havetherighttomodifythe report,andthemodificationinformationshallbeannotatedintherevisionform. (3)Anyobjectiontothisreportshallberaisedwithin30daysafterformalconfirmationofthe report. (4)Thisreportisinvalidifthereisanyevidencethatthesampleinformationprovidedisfalsified. (5)Thereportisinvalidwithoutthesignatureoftheauditorandapprover. ReportNo.:RFI-LAB-RF-202304-DD12 QP030-E41 Page5of9 2.SampleInformation 2.1Clientinformation Name EC-LINKAutomation(Shenzhen)Co.Ltd. Address Room2206,BlockB,ShixiaXintianCentury,BusinessCenter,Futian District,ShenzhenCity,China Contacts / Tel / E-mail / Manufacturer / 2.2Descripโฆ
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 902.75 MHz - 927.25 MHz | 126.20 mW |

RFID Module
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
RFID Module
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter