FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ShenZhen Zhongyi Technology CO., Ltd./
  3. 2A9Q9-M2116Q

2A9Q9-M2116Q10,000mAh Magnetic wireless powerbank

ShenZhen Zhongyi Technology CO., Ltd.
10,000mAh Magnetic wireless powerbank - FCC ID 2A9Q9-M2116Q - ShenZhen Zhongyi Technology CO., Ltd.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Sep 12, 2024
Application Purpose
Original Equipment
Date of Application
Sep 12, 2024
Equipment Note
10,000mAh Magnetic wireless powerbank
Frequency Range
0.11500000 - 0.20500000
Company
ShenZhen Zhongyi Technology CO., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

165x110mm 10,000mAh MAGNETIC WIRELESS POWERBANK Instruction Manual M2116Q What’s included: 1x 10,000mAh Wireless Power Bank 1x Instruction Manual To ensure product safety, ensure that identical replacement parts. 12. Attachments on the back of your phone can impede the effectiveness of the 13. before charging on this device. The strong magnetic fields of neodymium magnets can damage items such as television, computer monitors, credit cards, bank cards, computers, diskettes and other data carriers, video tapes, mechanical watches, hearing aids, loud speakers and VCRs. Pace-makers may be damaged or switch to “Test Mode” in the presence of a strong magnetic force, if a pace-maker or other electrical body implant is in use, keep a minimum of 3 feet distance. 14. Please remove attachments from the phone wireless charger, and lead to overheating. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. (1) (2) * FCC Statement: LED Screen: • Press the Powerbank ON/OFF button(1) once to light up the view the voltage remaining power capacity. Capacity:10000mAh Lightning input:5V 2A Type-C input:5V 2.6A/9V 2A/12V 1.5A 18Wmax Wireless output:15W/10W/7.5W/5W Type-C output:5V 2.4 /9V 2.2A/12V 1.67A 20Wmax • • Connect the provided charging cable to a power source and to the Type-C Input on the powerbank. Once fully charged, the power capacity will show 100% power capacity. 1. • INSTRUCTIONS: Charging the PowerBank: Charge the powerbank fully before usage. 2. • • Charging Electronic Devices with the Power Bank Connect the appropriate cable to your mobile phone/device. Connect the Type-C tip or USB-A tip of a cable to Type-C Output or USB-A Output. • Remove the charging cable from your mobile device when fully charged. on the screen, an unknown object is being detected between the wireless charging pad and the phone by FOD(Foreign Object Detection). Note: If the wireless charging symbol flashes ** 3. • Charging Electronic Devices with the Wireless Charging: Press Powerbank button the LED screen Place wireless charging enable device on Wireless Charging Pad. The device will begin to charge, the wireless charging symbol will show on the LED screen when charging. Remove your mobile device and powerbank once fully charged. • • will show the remaining power capacity, and the wireless charging symbol will flash once the power bank is in wireless charging standby mode. Do not overcharge your phone. The unit may become hot under excessive use. Remove your phone once it is fully charged. Never charge your phone for more than 7 hours at a time. The unit will only achieve full performance after 2 or 3 completed charge and discharge cycles. To reduce the risk of injury, close supervision is required when the product is used near children. Do not expose the device to moisture. Do not use the device in excess of its output rating. Overload outputs above the Do not use the device if damaged or explosion or risk of injury. Do not disassemble the device. For professional. Incorrect reassembly may or temperatures above 104°F (40°C) may result in explosion. 3. 4. 5. 6. 7. 8. 9. 10. 11. WARNING-When using this product, basic precautions should always be followed: Read all the instructions before use. Never store or use this product in temperatures below 32°F (0°C) or above 115°F (45°C). • 1. 2. SAFETY PRECAUTIONS: The powerbank will not begin to charge until object is removed. MADE IN CHINA The strong magnetic fields of neodymium magnets can damage items such as television, computer monitors, credit cards, bank cards, computers, diskettes and other data carriers, video tapes, mechanical watches, hearing aids, loudspeakers, and VCRs. Pacemakers may be damaged or switched to “test mode” in the presence of a strong magnetic force, if pacemaker or other electronical body implant is in use, keep a minimum of 3 feet distance. iPh input Type-C input output Power button Holde Magnetic Wireless Charging Digital Display

Attestation Statements

(ShenZhen Zhongyi Technology CO., Ltd.) (2024.9.3) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2A9Q9-M2116Q) [ShenZhen Zhongyi Technology CO., Ltd.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Client’s signature: Client’s name : Merry Yu (ShenZhen Zhongyi Technology CO., Ltd.) (2024.9.3) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2A9Q9-M2116Q) [ShenZhen Zhongyi Technology CO., Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Client’s signature: Client’s name : Merry Yu

Attestation Statements

Attestation Statements (2024/9/3) TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA RE: Attestation Statements Part 2.911(d)(7) request for (FCC ID: 2A9Q9-M2116Q) (ShenZhen Zhongyi Technology CO., Ltd.), the undersigned, hereby authorize AOCE Corporation Inc. to act as our designated U.S. agent for service of process, (ShenZhen Zhongyi Technology CO., Ltd.) accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. AOCE Corporation Inc. accepts the responsibility to act as designated U.S. agent for service of process. Applicant Information: Company Name: ShenZhen Zhongyi Technology CO., Ltd. Address: Room 401, No.4 Road One, Shangxue Science and Technology City, Xinxue Community, Bantian Street, Longgang District, Shenzhen, China Contact Name: Merry Yu FRN: 0033187147 Telephone No: 0755-89501773 Email: [email protected] Signature [Merry Yu] U.S. Agent Information: Company Name: AOCE Corporation Inc. Address: 6547 N Academy Bivd #2266, Colorado Springs, CO, 80918 United States FRN: 0033401381 Contact Name: Johnson.wang Telephone No: +1-346-582-5234 Email: [email protected] Signature [Johnson.wang]

Cover Letter(s)

ShenZhen Zhongyi Technology CO., Ltd. 2024.9.3 Eurofins Electrical and Electronic Testing NA, Inc. 914 W. Patapsco Avenue Baltimore, MD 21230 USA RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Shenzhen BCTC Testing Co., Ltd to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Client’s signature: Client’s name / title : Merry Yu/ Manager Contact information / address: Room 401, No.4 Road One, Shangxue Science and Technology City, Xinxue Community, Bantian Street, Longgang District, Shenzhen, China

Cover Letter(s)

ShenZhen Zhongyi Technology CO., Ltd. 2024.9.3 Eurofins Electrical and Electronic Testing NA, Inc. 914 W. Patapsco Avenue Baltimore, MD 21230 USA RE: CONFIDENTIALITY REQUEST FOR EUT NAME: MAGNETIC WIRELESS POWERBANK Trademark: N/A MODEL: M2116Q FCC ID: 2A9Q9-M2116Q To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the - Block Diagram - Schematics - Operational Description required to be submitted with this application be permanently withheld from public review. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Please contact me if there is any information you may need. Sincerely, Client’s signature: Client’s name / title : Merry Yu/ Manager Contact information / address: Room 401, No.4 Road One, Shangxue Science and Technology City, Xinxue Community, Bantian Street, Longgang District, Shenzhen, China

External Photos

External Photos

ID Label/Location Info

Location Label FCC ID: 2A9Q9-M2116Q

Internal Photos

Internal Photos Antenna

RF Exposure Info

No.:BCTC/RF-EMC-005 Page 1 of 16 Edition:B.2 TEST REPORT Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC2409321240-2E Applicant: ShenZhen Zhongyi Technology CO., Ltd. Product Name: 10,000mAh Magnetic wireless powerbank Test Model: M2116Q Tested Date: 2024-09-06 to 2024-09-11 Issued Date: 2024-09-11 Report No.: BCTC2409321240-2E No.:BCTC/RF-EMC-005 Page 2 of 16 Edition:B.2 FCC ID: 2A9Q9-M2116Q The test report is effective only with both signature and specialized stamp.This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen BCTC Testing Co., Ltd, this report can’t be reproduced except in full.The tested sample(s) and the sample information are provided by the client. Product Name: 10,000mAh Magnetic wireless powerbank Trademark: N/A Model/Type Reference: M2116Q Prepared For: ShenZhen Zhongyi Technology CO., Ltd. Address: Room 401, No.4 Road One, Shangxue Science and Technology City, Xinxue Community, Bantian Street, Longgang District, Shenzhen, China Manufacturer: ShenZhen Zhongyi Technology CO., Ltd. Address: Room 401, No.4 Road One, Shangxue Science and Technology City, Xinxue Community, Bantian Street, Longgang District, Shenzhen, China Prepared By: Shenzhen BCTC Testing Co., Ltd. Address: 1-2/F., Building B, Pengzhou Industrial Park, No.158, Fuyuan 1st Road, Zhancheng, Fuhai Subdistrict, Bao'an District, Shenzhen, Guangdong, China. Sample Received Date: 2024-09-06 Sample Tested Date: 2024-09-06 to 2024-09-11 Issue Date: 2024-09-11 Report No.: BCTC2409321240-2E Test Standards: FCC CFR 47 part1, 1.1307(b), 1.1310 Test Results: PASS Tested by: Approved by: Shanshan. Zhang / Project Handler Zero Zhou/Reviewer Report No.: BCTC2409321240-2E No.:BCTC/RF-EMC-005 Page 3 of 16 Edition:B.2 Table Of Content Test Report Declaration Page 1. Version .................................................................................................................. 4 2. Product Information ............................................................................................... 5 2.1 Product Information ............................................................................................... 5 2.2 Support Equipment ............................................................................................... 5 2.3 Test Mode ............................................................................................................. 6 3. Test Facility And Test Instrument Used ................................................................. 7 3.1 Test Facility ........................................................................................................... 7 3.2 Test Instrument Used ............................................................................................ 7 4. Method Of Measurement ....................................................................................... 8 4.1 Applicable Standard .............................................................................................. 8 4.2 Block Diagram Of Test Setup ................................................................................ 8 4.3 Limit ...................................................................................................................... 9 4.4 Test procedure ...................................................................................................... 9 4.5 Equipment Approval Considerations ................................................................... 10 4.6 E and H field Strength ......................................................................................... 11 5. Photographs Of Test Set-Up ............................................................................... 15 (Note: N/A Means Not Applicable) Report No.: BCTC2409321240-2E No.:BCTC/RF-EMC-005 Page 4 of 16 Edition:B.2 1. Version Report No. Issue Date Description Approved BCTC2409321240-2E 2024-09-11 Original Valid Report No.: BCTC2409321240-2E No.:BCTC/RF-EMC-005 Page 5 of 16 Edition:B.2 2. Product Information 2.1 Product Information Model/Type Reference: M2116Q Model Differences: N/A Hardware Version: N/A Software Version: N/A Modulation: ASK Operation Frequency: 115kHz-205kHz Antenna installation: loop coil antenna Ratings: Lightning input:5V 2A Type-C input:5V/2.6A, 9V/2A, 12V/1.5A, 18Wmax Wireless output:15W/10W/7.5W/5W Type-C output:5V/2.4A, 9V/2.2A, 12V/1.67A, 20Wmax Battery: DC 3.85V 2.2 Support Equipment No. Device Type Brand Model Series No. Note E-1 10,000mAh Magnetic wireless powerbank N/A M2116Q N/A EUT E-2 ADAPTER Hoco. N18 N/A Auxiliary E-3 Dummy load N/A DL01 N/A Auxiliary Notes: 1. All the equipment/cables were placed in the worst-case configuration to maximize the emission during the test. 2. Grounding was established in accordance with the manufacturer’s requirements and conditions for the intended use. Report No.: BCTC2409321240-2E No.:BCTC/RF-EMC-005 Page 6 of 16 Edition:B.2 2.3 Test Mode AC Mode Mode 1 Type C Input Charging+Full load(115-205kHz, 5W) Mode 2 Lightning Input Charging+Full load(115-205kHz, 5W) Mode 3 Type C Input Charging+Half load Mode 4 Lightning Input Charging+Half load Mode 5 Type C Input Charging+Null load Mode 6 Lightning Input Charging+Null load DC Mode Mode 7 Full Load(115-205kHz, 15W) Mode 8 Half Load Mode 9 Null Load Note: All test mode were tested and passed, only shows the worst case mode which were recorded in this report. Report No.: BCTC2409321240-2E No.:BCTC/RF-EMC-005 Page 7 of 16 Edition:B.2 3. Test Facility And Test Instrument Used 3.1 Test Facility All measurement facilities used to collect the measurement data are located at Shenzhen BCTC Testing Co., Ltd. Address:1-2/F., Building B, Pengzhou Industrial Park, No.158, Fuyuan 1st Road, Zhancheng, Fuhai Subdistrict, Bao'an District, Shenzhen, Guangdong, China. The site and apparatus are constructed in conformance with the requirements of ANSI C63.4 and CISPR 16-1-1 other equivalent standards. FCC Test Firm Registration Number: 712850 …

Text truncated - open the document above for the full version.

Test Report

承 認 書 SPECIFICATION FOR APPROVAL 客戶: CUSTOMER: 客 戶 料 號: CUST P/N: 言之行 料 號: Y Z X P/N: 産 品 型 號: DESC: Φ42MMX5.0MM 日 期: DATE: 2024/2/28 版本: Version: A.0 擬制 PREPARED BY 審核 CHECKED BY 批准 APPROVED BY 客戶承認 CUSTOMER APPROVE 李墨 万楼 李建波 东 莞市言之行电子科技有限公司 Dongguan Yanzhixing Electronic Technology Co., Ltd 工廠地址:东莞市塘厦镇石马新围8号 李生TEL:18033336905 SPECIFICATION 産 品 型 號: DESC Φ42MMX5.0MM 版本 Rev:A.0 客戶CUST: 客户料号CUST P/N: 一、尺寸DIMENSION:(mm) 二、原理图SCHEMATIC DIAGRAM: A 39.5±1.5 B 20.5±0.5 D ±3 E 2-5 F 42.5±2 G 10.0 ref H 2.5Max J 42±1 注: 1.交叉出线; 2.中心位置贴20*1圆形硬磁 3.具体参数以实物为准 三、绕线参数Winding Specification: 序号 NO. 端子 TERMINAL 线径 WIRE 圈数 Turns 绕线方向 Winding Direction 1 S F 1.0±0.15 10Ts CCW 四、电气特性ELECTRICAL CHARACTERISTICS: 温度TEMPERATURE:25±10°C, 湿度RELATIVE HUMIDITY:65±20% 序号 NO. 项目 ITEM 端子 TERMINAL 标准 SPECIFICATION 测试条件 TEST FREQUENCY 测试仪器 TEST EQUIPMENTS 1 IND. S-F 3.8uH ±20%单独线圈 100KHz/1.0V LCZ METER 1062B 2 IND. S-F 6.5uH ±10%加磁片 100KHz/1.0V LCZ METER 1062B 3 DCR S-F ≤55mΩLCZ METER 502B 擬制/日期PREPARED BY/DATE 審核/日期CHECKED BY/DATE

Test Report

No.:BCTC/RF-EMC-005 Page 1 of 29 Edition:B.2 TEST REPORT Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC2409321240-1E Applicant: ShenZhen Zhongyi Technology CO., Ltd. Product Name: 10,000mAh Magnetic wireless powerbank Test Model: M2116Q Tested Date: 2024-09-06 to 2024-09-11 Issued Date: 2024-09-11 Report No.: BCTC2409321240-1E No.:BCTC/RF-EMC-005 Page 2 of 29 Edition:B.2 FCC ID: 2A9Q9-M2116Q The test report is effective only with both signature and specialized stamp.This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen BCTC Testing Co., Ltd, this report can’t be reproduced except in full.The tested sample(s) and the sample information are provided by the client. Product Name: 10,000mAh Magnetic wireless powerbank Trademark: N/A Model/Type Reference: M2116Q Prepared For: ShenZhen Zhongyi Technology CO., Ltd. Address: Room 401, No.4 Road One, Shangxue Science and Technology City, Xinxue Community, Bantian Street, Longgang District, Shenzhen, China Manufacturer: ShenZhen Zhongyi Technology CO., Ltd. Address: Room 401, No.4 Road One, Shangxue Science and Technology City, Xinxue Community, Bantian Street, Longgang District, Shenzhen, China Prepared By: Shenzhen BCTC Testing Co., Ltd. Address: 1-2/F., Building B, Pengzhou Industrial Park, No.158, Fuyuan 1st Road, Zhancheng, Fuhai Subdistrict, Bao'an District, Shenzhen, Guangdong, China. Sample Received Date: 2024-09-06 Sample Tested Date: 2024-09-06 to 2024-09-11 Issue Date: 2024-09-11 Report No.: BCTC2409321240-1E Test Standards: FCC Part15.209 ANSI C63.10-2013 Test Results: PASS Tested by: Approved by: Shanshan. Zhang / Project Handler Zero Zhou/Reviewer Report No.: BCTC2409321240-1E No.:BCTC/RF-EMC-005 Page 3 of 29 Edition:B.2 Table Of Content Test Report Declaration Page 1. Version .................................................................................................................. 4 2. Test Summary ....................................................................................................... 5 3. Measurement Uncertainty ..................................................................................... 6 4. Product Information And Test Setup ..................................................................... 7 4.1 Product Information ............................................................................................... 7 4.2 Support Equipment ............................................................................................... 7 4.3 Test Setup Configuration ...................................................................................... 8 4.4 Test Mode ............................................................................................................. 9 5. Test Facility And Test Instrument Used ............................................................... 10 5.1 Test Facility ......................................................................................................... 10 5.2 Test Instrument Used .......................................................................................... 10 6. Conducted Emissions .......................................................................................... 12 6.1 Block Diagram Of Test Setup .............................................................................. 12 6.2 Limit .................................................................................................................... 12 6.3 Test procedure .................................................................................................... 12 6.4 EUT operating Conditions ................................................................................... 12 6.5 Test Result .......................................................................................................... 13 7. Radiated Emissions ............................................................................................. 15 7.1 Block Diagram Of Test Setup .............................................................................. 15 7.2 Limit .................................................................................................................... 16 7.3 Test procedure .................................................................................................... 16 7.4 Test Result .......................................................................................................... 17 8. Bandwidth Test .................................................................................................... 23 8.1 Test Procedure ................................................................................................... 23 8.2 Test Setup ........................................................................................................... 23 8.3 Test Result .......................................................................................................... 24 9. Antenna Requirements ........................................................................................ 25 9.1 Limit .................................................................................................................... 25 9.2 Test Result .......................................................................................................... 25 10. EUT Photographs ................................................................................................ 26 11. EUT Test Setup Photographs.............................................................................. 27 (Note: N/A Means Not Applicable) Report No.: BCTC2409321240-1E No.:BCTC/RF-EMC-005 Page 4 of 29 Edition:B.2 1. Version Report No. Issue Date Description Approved BCTC2409321240-1E 2024-09-11 Original Valid Report No.: BCTC2409321240-1E No.:BCTC/RF-EMC-005 Page 5 of 29 Edition:B.2 2. Test Summary The Product has been tested according to the following specifications: No. Test Parameter Clause No. Results 1 Conducted Emission 15.207 PASS 2…

Text truncated - open the document above for the full version.

Test Setup Photos

Conducted emissions Radiated Measurement Photos 30MHz-1GHz 9kHz-30MHz

Contact Information

Applicant

Merry Yu
[email protected]0755-89501773Fax: 0755-89501773

Test Firm

Shenzhen BCTC Testing Co., Ltd.Sally He
[email protected]15999690624

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.115 MHz - 0.205 MHz-
Confidentiality
Long Term

Other Applications from ShenZhen Zhongyi Technology CO., Ltd.

10000mAh Wireless Power Bank - FCC ID 2A9Q9-M2319Q - ShenZhen Zhongyi Technology CO., Ltd.
2A9Q9-M2319Q

10000mAh Wireless Power Bank

Jun 05, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
5000mAh Wireless Power Bank - FCC ID 2A9Q9-M2359Q - ShenZhen Zhongyi Technology CO., Ltd.
2A9Q9-M2359Q

5000mAh Wireless Power Bank

Jun 05, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Slimline 5000mAh 20W PD Aluminum Power Bank - FCC ID 2A9Q9-EPB-SL26 - ShenZhen Zhongyi Technology CO., Ltd.
2A9Q9-EPB-SL26

Slimline 5000mAh 20W PD Aluminum Power Bank

Mar 18, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Array 15000mAh 20W Magnetic Wireless Power Bank - FCC ID 2A9Q9-EPB-AR26 - ShenZhen Zhongyi Technology CO., Ltd.
2A9Q9-EPB-AR26

Array 15000mAh 20W Magnetic Wireless Power Bank

Mar 16, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Diplomat 10000mAh 20W PD Power Bank - FCC ID 2A9Q9-EPB-DP26 - ShenZhen Zhongyi Technology CO., Ltd.
2A9Q9-EPB-DP26

Diplomat 10000mAh 20W PD Power Bank

Mar 05, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz