FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Varex Imaging Deutschland AG/
  3. 2AA8Z-XRPAD

2AA8Z-XRPAD802.11n 3T3R Mini PCIe Module

Varex Imaging Deutschland AG
802.11n 3T3R Mini PCIe Module - FCC ID 2AA8Z-XRPAD - Varex Imaging Deutschland AG
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Dec 12, 2013
Application Purpose
Original Equipment
Date of Application
Dec 12, 2013
Equipment Note
802.11n 3T3R Mini PCIe Module
Frequency Range
5500.00000000 - 5700.00000000
Company
Varex Imaging Deutschland AG
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

WPEA-127NI PRODUCT SPECIFICATION Standard IEEE802.11 abgn Chipset Atheros AR9390-AL1B Radio stream [Note1] 3T3R Antenna Type / con. 3 U.FL connectors (diversity ant) Bus Interface PCI Express Form Factor Mini PCIe Data Rate 802.11b: 11, 5.5,2,1Mbps 802.11g: 54, 48, 36, 24, 18, 12, 9, 6Mbps 802.11a: 54, 48, 36, 24, 18, 12, 9, 6 Mbps 802.11n: MCS 0 to 23 for HT20MHz MCS 0 to 23 for HT40MHz Media Access Control CSMA/CA with ACK Spreading /Modulation Techniques 802.11a: OFDM (BPSK, QPSK, 16-QAM, 64-QAM) 802.11b: DSSS (DBPSK, DQPSK, CCK) 802.11g: OFDM (BPSK,QPSK,16-QAM,64-QAM) 802.11n: OFDM (BPSK,QPSK,16-QAM,64-QAM) Frequency Range [Note2] 2.4GHz 11b/g/n: 2.400 ~ 2.4835GHz 5GHz 11a/n: 5.150GHz ~ 5.825GHz Transmit Output Power (Tolerance: +/-2dBm) 802.11a: 11dBm ± 2dBm@54Mbps 802.11b: 19dBm ± 2dBm@11Mbps 802.11g: 16dBm ± 2dBm@54Mbps 802.11gn HT20: 15dBm ± 2dBm@MCS7 802.11gn HT40: 15dBm ± 2dBm@MCS7 802.11an HT20: 11dBm ± 2dBm@MCS7 802.11an HT40: 11dBm ± 2dBm@MCS7 Receiver Sensitivity (Tolerance: +/-2dBm) 802.11a: -78dBm ± 2dBm@54Mbps 802.11b: -95dBm ± 2dBm@11Mbps 802.11g: -79dBm ± 2dBm@54Mbps 802.11gn HT20: -76dBm ± 2dBm@MCS7 802.11gn HT40: -74dBm ± 2dBm@MCS7 802.11an HT20: -75dBm ± 2dBm@MCS7 802.11an HT40: -72dBm ± 2dBm@MCS7 Operating Voltage 3.3V ±10% I/O supply voltage Power Consumption TX Mode: 970mA RX Mode: 300mA Associated Idle: 50 mA Temperature Range -40~+80°C (Operating) [Note3] Humidity (non-condensing) 20~80%(Operating), 5~95%(Storing) [Note3] Security WEP / WPA / WPA2 OS supported Windows XP/Vista/Win7, Linux Note: 1. For Radio stream with diversity or MIMO design, all RF connectors on the module must be fitting antennas in order to guarantee the module performance. 2. The frequency range need to local regulations. 3. The storing condition is only for product functionality, no included for parts appearance. Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. IMPORTANT NOTE: FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Operations in the 5.15-5.25GHz band are restricted to indoor usage only. This device is intended only for OEM integrators under the following conditions: 1) The antenna must be installed such that 20 cm is maintained between the antenna and users, and 2) The transmitter module may not be co-located with any other transmitter or antenna. As long as 2 conditions above are met, further transmitter test will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed IMPORTANT NOTE: In the event that these conditions can not be met (for example certain laptop configurations or co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID can not be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC authorization. End Product Labeling This transmitter module is authorized only for use in device where the antenna may be installed such that 20 cm may be maintained between the antenna and users. The final end product must be labeled in a visible area with the following: “Contains FCC ID: 2AA8Z-XRPAD”. The grantee's FCC ID can be used only when all FCC compliance requirements are met. Manual Information To the End User The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module. The end user manual shall include all required regulatory information/warning as show in this manual. Industry Canada statement: This device complies with RSS-210 of the Industry Canada Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Ce dispositif est conforme à la norme CNR-210 d'Industrie Canada applicable aux appareils radio exempts de licence. Son fonctionnement est sujet aux deux conditions suivantes: (1) le disposi…

Text truncated - open the document above for the full version.

Cover Letter(s)

FCC ID: 2AA8Z-XRPAD Report No. : RF 131105C14 Modular Approval Request Letter Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch December 9, 2013 Dear Application Examiner, PerkinElmer Medical Imaging, 802.11n 3T3R Mini PCIe Module, FCC ID: 2AA8Z-XRPAD would like to have your authorization as a modular approval specific to the mobile RF exposure condition. 1. “The modular transmitter must have its own RF shielding.”: The radio portion of this module has been shielded, please see exhibition External Photo. 2. “The modular transmitter must have buffered modulation/data inputs.” The EUT has buffered data inputs, it is integrated in chip AR9592. 3. “The modular transmitter must have its own power supply regulation part no.:. AR9592. 4. “The modular transmitter must comply with the antenna requirements of section 15.203 and 15.204(C).” The EUT meets the FCC antenna requirements. The spurious emission, unique antenna connector and photo of antennas are shown in the test report. 5. “The modular transmitter must be tested in a stand-alone configuration”. The EUT is tested in a stand-alone configuration Mini PCI extender. Please see section Photographs of Test Configuration in the test report. 6. “The modular transmitter must be labeled with its own FCC ID number.” Please see exhibition Label Sample for the FCC ID of this module. And also in the exhibition Users Manual, there are instructions give to the OEM on how to label the end product. FCC ID: 2AA8Z-XRPAD Report No. : RF 131105C14 7. “The modular transmitter must comply with any specific rule or operating requirements applicable to the transmitter and the manufacturer must provide adequate instructions along with the module to explain any such requirements.” The EUT is compliant with all applicable FCC rules. Detail instructions for maintaining compliance are given in the Users Manual. 8. “The modular transmitter must comply with any applicable RF exposure requirements.” The EUT is compliant with all applicable RF exposure requirements. RF Exposure is addressed in the RF exposure exhibition. Please contact me if you have any further questions. Thanks for your attention. Best Regards, Robert Huang Senior Engineer Bureau Veritas Consumer Products Services (H.K.) Ltd., Hsinchu Branch

External Photos

Page 1 CONSTRUCTION PHOTOS OF EUT Page 2

Internal Photos

Page 3 Page 4

RF Exposure Info

Report No.: SA120328C12F 1 of 6 Report Format Version 5.0.0 Reference No.: 131105C14 RF EXPOSURE REPORT REPORT NO.: SA120328C12F MODEL NO.: WPEA-127NI FCC ID: 2AA8Z-XRPAD RECEIVED: Mar. 28, 2012 TESTED: Aug. 31 ~ Sep. 05, 2013 ISSUED: Nov. 14, 2013 APPLICANT: PerkinElmer Medical Imaging ADDRESS: In der Rehbach 22, Walluf, Germany, 65396 ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan ( R.O.C. ) TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-com pliance to the specification. Report No.: SA120328C12F 2 of 6 Report Format Version 5.0.0 Reference No.: 131105C14 TABLE OF CONTENTS RELEASE CONTROL RECORD .............................................................................................................. 3 1. CERTIFICATION ........................................................................................................................... 4 2. RF EXPOSURE ............................................................................................................................. 5 2.1 LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) ...................................................... 5 2.2 MPE CALCULATION FORMULA .................................................................................................. 5 2.3 CLASSIFICATION ......................................................................................................................... 5 2.4 CALCULATION RESULT OF MAXIMUM CONDUCTED POWER ............................................... 6 Report No.: SA120328C12F 3 of 6 Report Format Version 5.0.0 Reference No.: 131105C14 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED SA120328C12F Original release Nov. 14, 2013 Report No.: SA120328C12F 4 of 6 Report Format Version 5.0.0 Reference No.: 131105C14 1. CERTIFICATION PRODUCT: 802.11a/b/g/n 3T3R Mini PCIe Module MODEL: WPEA-127NI BRAND: PerkinElmer APPLICANT: PerkinElmer Medical Imaging TESTED: Aug. 31 ~ Sep. 05, 2013 TEST SAMPLE: ENGINEERING SAMPLE STANDARDS: FCC Part 2 (Section 2.1091) FCC OET Bulletin 65, Supplement C (01-01) IEEE C95.1 The above equipment (Model: WPEA-127NI) has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. PREPARED BY : , DATE:Nov. 14, 2013 Pettie Chen / Senior Specialist APPROVED BY : , DATE: Nov. 14, 2013 Ken Liu / Senior Manager Report No.: SA120328C12F 5 of 6 Report Format Version 5.0.0 Reference No.: 131105C14 2. RF EXPOSURE 2.1 LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) FREQUENCY RANGE (MHz) ELECTRIC FIELD STRENGTH (V/m) MAGNETIC FIELD STRENGTH (A/m) POWER DENSITY (mW/cm 2 ) AVERAGE TIME (minutes) LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE 300-1500 ... ... F/1500 30 1500-100,000 ... ... 1.0 30 F = Frequency in MHz 2.2 MPE CALCULATION FORMULA Pd = (Pout*G) / (4*pi*r 2 ) where Pd = power density in mW/cm 2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm 2.3 CLASSIFICATION The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So, this device is classified as Mobile Device. Report No.: SA120328C12F 6 of 6 Report Format Version 5.0.0 Reference No.: 131105C14 2.4 CALCULATION RESULT OF MAXIMUM CONDUCTED POWER FREQUENCY BAND (MHz) MAX POWER (dBm) ANTENNA GAIN (dBi) DISTANCE (cm) POWER DENSITY (mW/cm 2 ) LIMIT (mW/cm 2 ) 5180-5240 14.36 4.58 20 0.016 1 5260-5320 17.12 4.58 20 0.029 1 5500-5700 17.11 4.58 20 0.029 1 5745-5825 20.64 4.58 20 0.066 1

Test Report

Report No.: RF120328C12F-2 1 of 23 Report Format Version 5.0.0 Reference No.: 131105C14 DFS TEST REPORT REPORT NO.: RF120328C12F-2 MODEL NO.: WPEA-127NI FCC ID: 2AA8Z-XRPAD RECEIVED: Aug. 13, 2013 TESTED: Sep. 11, 2013 ISSUED: Nov. 14, 2013 APPLICANT: PerkinElmer Medical Imaging ADDRESS: In der Rehbach 22, Walluf, Germany, 65396 ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan ( R.O.C. ) TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the com pliance or non-compliance to the specification. This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Report No.: RF120328C12F-2 2 of 23 Report Format Version 5.0.0 Reference No.: 131105C14 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................... 3 1 CERTIFICATION ............................................................................................. 4 2 EUT INFORMATION ....................................................................................... 5 2.1 OPERATING FREQUENCY BANDS AND MODE OF EUT ............................ 5 2.2 EUT SOFTWARE AND FIRMWARE VERSION .............................................. 5 2.3 DESCRIPTION OF AVAILABLE ANTENNAS TO THE EUT............................ 5 2.4 EUT MAXIMUM AND MINIMUM CONDUCTED POWER ............................... 6 2.5 EUT MAXIMUM AND MINIMUM E.I.R.P. POWER .......................................... 7 2.6 TRANSMIT POWER CONTROL (TPC) .......................................................... 8 2.7 STATEMENT OF MAUNFACTURER .............................................................. 8 3 U-NII DFS RULE REQUIREMENTS ............................................................... 9 3.1 WORKING MODES AND REQUIRED TEST ITEMS ...................................... 9 3.2 TEST LIMITS AND RADAR SIGNAL PARAMETERS ................................... 10 4 TEST & SUPPORT EQUIPMENT LIST ........................................................ 12 4.1 TEST INSTRUMENTS .................................................................................. 12 4.2 DESCRIPTION OF SUPPORT UNITS ......................................................... 12 5 TEST PROCEDURE ..................................................................................... 13 5.1 ADT DFS MEASUREMENT SYSTEM: ......................................................... 13 5.2 CALIBRATION OF DFS DETECTION THRESHOLD LEVEL: ...................... 14 5.3 DEVIATION FROM TEST STANDARD ......................................................... 14 5.4 CONDUCTED TEST SETUP CONFIGURATION ......................................... 15 5.4.1 CLIENT WITHOUT RADAR DETECTION MODE ......................................... 15 6 TEST RESULTS ........................................................................................... 16 6.1 SUMMARY OF TEST RESULTS .................................................................. 16 6.2 TEST RESULTS ........................................................................................... 17 6.2.1 TEST MODE: DEVICE OPERATING IN CLIENT WITHOUT RADAR DETECTION MODE. .................................................................................... 17 6.2.2 CHANNEL CLOSING TRANSMISSION AND CHANNEL MOVE TIME ........ 18 6.2.3 NON- OCCUPANCY PERIOD ...................................................................... 20 6.2.4 NON-ASSOCIATED TEST ............................................................................ 22 6.2.5 NON- CO-CHANNEL TEST .......................................................................... 22 7 INFORMATION ON THE TESTING LABORATORIES .................................. 23 Report No.: RF120328C12F-2 3 of 23 Report Format Version 5.0.0 Reference No.: 131105C14 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED RF120328C12F-2 Original release Nov. 14, 2013 Report No.: RF120328C12F-2 4 of 23 Report Format Version 5.0.0 Reference No.: 131105C14 1 CERTIFICATION PRODUCT: 802.11a/b/g/n 3T3R Mini PCIe Module MODEL: WPEA-127NI BRAND: PerkinElmer APPLICANT: PerkinElmer Medical Imaging TEST SAMPLE: ENGINEERING SAMPLE TESTED: Sep. 11, 2013 STANDARDS: FCC Part 15, Subpart E (Section 15.407) FCC 06-96 The above equipment (Model: WPEA-127NI) has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristi…

Text truncated - open the document above for the full version.

Test Report

Report No.: RF120328C12F 1 of 52 Report Format Version 5.2.0 Reference No.: 131105C14 FCC TEST REPORT (15.247) REPORT NO.: RF120328C12F MODEL NO.: WPEA-127NI FCC ID: 2AA8Z-XRPAD RECEIVED: Aug. 13, 2013 TESTED: Aug. 31 ~ Sep. 05, 2013 ISSUED: Nov. 14, 2013 APPLICANT: PerkinElmer Medical Imaging ADDRESS: In der Rehbach 22, Walluf, Germany, 65396 ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan, R.O.C. TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the com pliance or non-compliance to the specification. This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Report No.: RF120328C12F 2 of 52 Report Format Version 5.2.0 Reference No.: 131105C14 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................................. 4 1. CERTIFICATION .......................................................................................................... 5 2. SUMMARY OF TEST RESULTS ................................................................................. 6 2.1 MEASUREMENT UNCERTAINTY ............................................................................... 6 3. GENERAL INFORMATION .......................................................................................... 7 3.1 GENERAL DESCRIPTION OF EUT ............................................................................ 7 3.2 DESCRIPTION OF TEST MODES .............................................................................. 8 3.2.1 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL .............................. 9 3.3 DUTY CYCLE OF TEST SIGNAL .............................................................................. 11 3.4 DESCRIPTION OF SUPPORT UNITS ...................................................................... 12 3.4.1 CONFIGURATION OF SYSTEM UNDER TEST ....................................................... 12 3.5 GENERAL DESCRIPTION OF APPLIED STANDARDS ........................................... 13 4. TEST TYPES AND RESULTS ................................................................................... 14 4.1 RADIATED EMISSION MEASUREMENT ................................................................. 14 4.1.1 LIMITS OF RADIATED EMISSION MEASUREMENT ............................................... 14 4.1.2 TEST INSTRUMENTS ............................................................................................... 15 4.1.3 TEST PROCEDURES ............................................................................................... 16 4.1.4 DEVIATION FROM TEST STANDARD...................................................................... 16 4.1.5 TEST SETUP ............................................................................................................. 17 4.1.6 EUT OPERATING CONDITIONS .............................................................................. 18 4.1.7 TEST RESULTS ........................................................................................................ 19 4.2 CONDUCTED EMISSION MEASUREMENT ............................................................ 28 4.2.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT .......................................... 28 4.2.2 T EST INSTRUMENTS .............................................................................................. 28 4.2.3 TEST PROCEDURES ............................................................................................... 29 4.2.4 DEVIATION FROM TEST STANDARD...................................................................... 29 4.2.5 TEST SETUP ............................................................................................................. 29 4.2.6 EUT OPERATING CONDITIONS .............................................................................. 29 4.2.7 TEST RESULTS ........................................................................................................ 30 4.3 6dB BANDWIDTH MEASUREMENT ......................................................................... 32 4.3.1 LIMITS OF 6dB BANDWIDTH MEASUREMENT ...................................................... 32 4.3.2 TEST SETUP ............................................................................................................. 32 4.3.3 TEST INSTRUMENTS ............................................................................................... 32 4.3.4 TEST PROCEDURE .................................................................................................. 32 4.3.5 DEVIATION FROM TEST STANDAR…

Text truncated - open the document above for the full version.

Test Report

Report No.: RF120328C12F-1 1 of 73 Report Format Version 5.2.0 Reference No.: 131105C14 FCC TEST REPORT (15.407) REPORT NO.: RF120328C12F-1 MODEL NO.: WPEA-127NI FCC ID: 2AA8Z-XRPAD RECEIVED: Aug. 13, 2013 TESTED: Aug. 31 ~ Sep. 05, 2013 ISSUED: Nov. 14, 2013 APPLICANT: PerkinElmer Medical Imaging ADDRESS: In der Rehbach 22, Walluf, Germany, 65396 ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan, R.O.C. TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the com pliance or non-compliance to the specification. This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Report No.: RF120328C12F-1 2 of 73 Report Format Version 5.2.0 Reference No.: 131105C14 TABLE OF CONTENTS RELEASE CONTROL RECORD .............................................................................................................. 4 1. CERTIFICATION .................................................................................................................... 5 2. SUMMARY OF TEST RESULTS ............................................................................................ 6 2.1 MEASUREMENT UNCERTAINTY ......................................................................................... 6 3. GENERAL INFORMATION ..................................................................................................... 7 3.1 GENERAL DESCRIPTION OF EUT ....................................................................................... 7 3.2 DESCRIPTION OF TEST MODES ......................................................................................... 8 3.2.1 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL ........................................ 9 3.3 DUTY CYCLE OF TEST SIGNAL ........................................................................................ 11 3.4 DESCRIPTION OF SUPPORT UNITS ................................................................................. 15 3.4.1 CONFIGURATION OF SYSTEM UNDER TEST .................................................................. 15 3.5 GENERAL DESCRIPTION OF APPLIED STANDARDS ...................................................... 16 4. TEST TYPES AND RESULTS .............................................................................................. 17 4.1 RADIATED EMISSION AND BANDEDGE MEASUREMENT .............................................. 17 4.1.1 LIMITS OF RADIATED EMISSION AND BANDEDGE MEASUREMENT ........................... 17 4.1.2 LIMITS OF UNWANTED EMISSION OUT OF THE RESTRICTED BANDS ....................... 17 4.1.3 TEST INSTRUMENTS ......................................................................................................... 18 4.1.4 TEST PROCEDURES .......................................................................................................... 19 4.1.5 DEVIATION FROM TEST STANDARD ................................................................................ 19 4.1.6 TEST SETUP ...........................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Richard L Knispel(Sr. Design Engineer, Electronics)
[email protected]+496123971Fax: +496123971600

Test Firm

Bureau Veritas CPS (H.K.) Ltd., Taoyuan BranchRichard Chen
[email protected]+886-3-2600884Fax: +886-3-2115834

Technical Specifications

#Rule PartsFrequency RangePower Output
315E5.50 GHz - 5.70 GHz51.00 mW
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
Power listed is the maximum combined conducted output power. Single Modular Approval for mobile RF Exposure condition. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except the collocation as described in this filing or in accordance with FCC multi-transmitter product guidelines. Approval is limited to OEM installation only. OEM integrators must be provided with antenna installation instructions. OEM integrators and end-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Operations in the 5.15-5.25GHz band are restricted to indoor usage only. This device complies with the Dynamic Frequency Selection (DFS) requirements of Report and Order FCC 03-287 as a Client only without Radar Detection.

Other Applications from Varex Imaging Deutschland AG

802.11n 3T3R Mini PCIe Module - FCC ID 2AA8Z-XRPAD2 - Varex Imaging Deutschland AG
2AA8Z-XRPAD2

802.11n 3T3R Mini PCIe Module

Nov 10, 2015

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Digital X-Ray Detector System - FCC ID 2AA8Z-XRPAD4336 - Varex Imaging Deutschland AG
2AA8Z-XRPAD4336

Digital X-Ray Detector System

Dec 22, 2013

Equipment Class

NII - Unlicensed National Information Infrastructure TX