Document Title Document No. Version PUB XRPAD 4336 MED - USER MANUAL TBA 1 This document is confidential and proprietary to PerkinElmer The following pages contain the “User Manual” T B A , V e r . 0 1 P U B X R p a d 4 3 3 6 M E D U s e r M a n u a l P r i n t e d d o c u m e n t i s v a l i d f o r u s e w i t h i n t h e d a y p ri n t e d . U s e o r v e r i f y t h e l a t e s t r e v i s i o n o f d o c u m e n t i n D oc u m e n t C o n t r o l D i r e c t o r y P a g e 0 o f 3 4 REVISION SECTIONS CHANGED ORIGINATOR CN DATE 1 Initial release S. Arnold TBA 2013-11-29 www.perkinelmer.com DIGITAL IMAGING U S E R M A N U A L XRpad™ 4336 MED Digital X-Ray Detector System Before using the detector, be sure to read this manual thoroughly along with any other manuals for the software and other system components. Keep this manual where it is easily accessible. www.perkinelmer.com XRpad™ 4336 MED 2 U S E R M A N U A L PLEASE NOTE To avoid personal injury or product damage, read the manual and all accompanying information carefully before installation or use of the XRpad™ 4336 MED detector. The detector is intended for use by trained and qualified professional personnel who are knowledgeable with the use of x-ray detectors, x-ray systems, and electrical equipment. The user is responsible for using and maintaining the detector according to prescribed installation, usage, maintenance, handling and storage specifications. To keep the detector and its accessories in a safe and proper condition, only trained and qualified professional person(s) shall be in charge of maintenance. X-ray imaging, image processing, image acquisition, and data storage must be performed in accordance with the applicable laws. The user is also responsible for compliance to laws pertaining to the privacy of image data. In no event is PerkinElmer liable for direct, indirect, or consequential injury, damage, or loss of equipment operation time or image data arising from the use of the x-ray detector, its components, and or accessories. Protection against Ionizing Radiation Exposure of any part of the human body to x-radiation may be harmful to health. Whenever x-ray equipment or radioactive sources are in use, appropriate safety precautions and measures shall be instituted, and all regulatory requirements must be met. It is the responsibility of the x-ray system installer, operator, and user to comply with applicable requirements. The x-ray detector is intended to be installed, maintained, and used by qualified professional personnel who are trained and qualified in the installation, maintenance, and use of x-ray equipment. The x-ray detector does not contain a primary barrier for x-rays or Gamma rays. The x-ray system installer or manufacturer must provide the necessary protection based on the x-ray system’s intended use. For portable applications the x-ray system installer or manufacturer must provide the necessary training for the operator to protect them self, the patient, or surrounding persons. www.perkinelmer.com XRpad™ 4336 MED 3 U S E R M A N U A L FOR YOUR SAFETY To avoid personal injury or product damage, read this manual and all accompanying information carefully before handling, installing, or using the XRpad™ 4336 MED detector. Follow all instructions, warnings, and cautions in this manual and all warnings and cautions printed on the warning label. Ignoring instructions, warnings, or cautions in the handling, installing, or using of the detector may result in personal injury, death, or product damage. Keep this manual for future reference. Meaning of Caution Signs DANGER This indicates a potentially hazardous situation which, if ignored, will result in severe personal injury, death, or substantial product damage. WARNING This indicates a potentially hazardous situation which, if ignored, may result in severe personal injury, death, or substantial product damage. Caution This indicates a potential hazardous situation which, if ignored, may result in minor or moderate personal injury or damage to the product. Note: This emphasizes or supplements important information about the main text. Installation and Environmental Use WARNING Do not operate the x-ray detector in or around flammable gases, gas mixtures, liquids, chemicals, or other substances. Ignoring this warning may result in explosion, fire, or electric shock, which may result in severe personal injury, death, or substantial product damage. Caution Do not operate the x-ray detector in a location with the following conditions. • Close to fluid or places where fluid is used • Close to heat sources, such as a heater • High temperature environment • High humidity environment • High condensation environment • Extreme cold environment • Dusty environment • Salty or sulphurous environment • Near a vibrating environment Ignoring this caution may result in personal injury or damage to the product. WARNING Do not connect the x-ray detector to any component or accessory, other than manufacturer’s specified components and accessories. Ignoring this warning may result in explosion, fire, or electric shock, which may result in severe personal injury, death, or substantial product damage. WARNING Do not modify or alter the x-ray detector, its components, or accessories. Ignoring this warning may result in explosion, fire, or electric shock, which may result in severe personal injury, death, or substantial product damage. www.perkinelmer.com XRpad™ 4336 MED 4 U S E R M A N U A L Interface and Power Unit and Cables WARNING Be sure to turn OFF the power of the XRpad™ 4336 MED detector, including turning off the power supply and or removal of the XRpad™ LBP (Lithium Battery Pack) before servicing, maintaining, connecting, or disconnecting the cables or accessories. Do not touch the power supply, Lithium Battery Pack, detector, cable, connector, or any other electrical component or equipment with wet hands. Ignoring this warning may cause electrical shock, which may result …
Text truncated - open the document above for the full version.
Bank/Bank Account: Commerzbank Wiesbaden – 1243 883 00 (BLZ 510 80060) – S.W.I.F.T. Code COBADEFFXXX – IBAN: DE 42 5108 0060 01243 883000 Registergericht/Registered at Amtsgericht Wiesbaden HRA 5064 – Geschäftsführer/Managing Director: Dirk Schimmelschulze Steuernummer/Tax No. 43 355 60 116 – Ust.-Ident.-Nr./VAT.Reg.-No.: DE 144 602 639 Pers.haftender Gesellschafter /General Partner: PerkinElmer Cellular Technologies Germany GmbH Geschäftsführer/Managing Director: Dr. Jürgen Müller, Dirk Schimmelschulze – Registergericht/Registered at Amtsgericht Hamburg HRB 101440 PerkinElmer Technologies GmbH & Co. KG In der Rehbach 22 65396 Walluf , Germany P: +49 6123 971 300 F: +49 6123 971 600 www.perkinelmer.com PerkinElmer Technologies GmbH & Co. KG · P.O. Box 4622 · 65036 Wiesbaden Attention: Application Examiner December 23 th , 2013 Re: Request for confidentiality Applicant: PerkinElmer Technologies GmbH & Co. KG FCC ID: 2AA8Z-XRPAD4336 To whom it may concern, Permanent Confidentiality Request is hereby submitted by PerkinElmer to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept permanently confidential:  Schematics  Detailed Block diagrams  Detailed Operational/Functional Description  Parts list The referenced product is a non-consumer device inaccessible to general public. It is only serviceable by the licensee or designated technicians. Short-term Confidentiality Request is hereby submitted by PerkinElmer to withhold from public review for a period of 180 days from the Grant of Equipment Authorization and prior marketing, certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept confidential for a period of 180 days from the date of Authorization: Page 2 of 2 Bank/Bank Account: Commerzbank Wiesbaden – 1243 883 00 (BLZ 510 80060) – S.W.I.F.T. Code COBADEFFXXX – IBAN: DE 42 5108 0060 01243 883000 Registergericht/Registered at Amtsgericht Wiesbaden HRA 5064 – Geschäftsführer/Managing Director: Dirk Schimmelschulze Steuernummer/Tax No. 43 355 60 116 – Ust.-Ident.-Nr./VAT.Reg.-No.: DE 144 602 639 Pers.haftender Gesellschafter /General Partner: PerkinElmer Cellular Technologies Germany GmbH Geschäftsführer/Managing Director: Dr. Jürgen Müller, Dirk Schimmelschulze – Registergericht/Registered at Amtsgericht Hamburg HRB 101440  Test setup photos  Internal photos  External photos  User manual PerkinElmer has invested considerable time and materials in research and development to produce the referenced product. Disclosure of the permanently confidential portions of this application to competitors would not only give them significant competitive advantages in developing similar products, but would also disclose successful implementation of unpublished, leading edge technology developed by us. Disclosure of the short-term confidential portions of this application during the period of importation and/or distribution would reveal key aspects of proprietary technology to competitors and diminish the value of our investment in research and development. If you have questions or need further information, please contact the undersigned. Sincerely, Richard Knispel Sr. Design Engineer, Electronics PerkinElmer Technologies GMbH & Co. KG
An Independent Organization Testing for Safety and Performance Page 1 of 1 This report is for the exclusive use of Intertek’s Client and is provided pursuant to the agreement between Intertek and its Client. Intertek’s responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report by itself does not imply that the material, product or service is or has ever been under an Intertek certification program. Intertek Testing Services NA, Inc. 1365 Adams Ct., Menlo Park CA 94025 Telephone: 1-650-463-2900 Fax: 1-650-463-2910 Web: www.intertek-etlsemko.com SD 12.1.2 (2/21/07) Informative April 24, 2014 Federal Communications Commission Office of Engineering and Technology Laboratory Division Inquiry to modify Grant of Equipment Authorization FCC ID: 2AA8Z-XRPAD4336 Date of Grant: 12/23/2013 To whom it may concern, This letter is in regards to TCB certification of the PerkinElmer Medical Imaging, Digital X-Ray Detector System, operating in the 5.15 – 5.25 GHz UNII band. The frequency range on the Grant has been mistakenly written as 5.18 – 5.32 GHz. The correct frequency range is 5.18 – 5.24 GHz. TCB is requesting that the application be put into audit mode to make the necessary correction. This Inquiry is made according to the KDB 546630. The Tracking Number: 562507 Thank you. TCB Reviewer
External Photos 1 XRpad 4336 and XRpad 4336 MED Front side view Back side view
XRpad Digital X-ray Detector System Model:#Name? Input: REF SN #Name? Made in Germany PerkinElmer Technologies GmbH & Co. KG In der Rehbach 22 65396 Walluf, Germany #Name? MAC Address: +12.5V...15V / 2.2A ................ XRpad 4336 95510zzz zzz- yyyyy WLAN: nnnnnnnnnnnn MM / YYYY LAN: pppppppppppp +35°C +10°C 90% 10% no condensation FCC ID: 2AA8Z-XRPAD4336 IC: 11552A-XRPAD4336 31739 Rev. 01 IP42 TM This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any inter- ference received, including interference that may cause undesired operation. XRpad Digital X-ray Detector System Model:#Name? Input: REF SN #Name? Made in Germany PerkinElmer Technologies GmbH & Co. KG In der Rehbach 22 65396 Walluf, Germany #Name? MAC Address: +12.5V...15V / 2.2A ................ XRpad 4336 MED 95510zzz zzz- yyyyy WLAN: nnnnnnnnnnnn MM / YYYY LAN: pppppppppppp +35°C +10°C 90% 10% no condensation FCC ID: 2AA8Z-XRPAD4336 IC: 11552A-XRPAD4336 34818 Rev. 01 IP42 TM This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any inter- ference received, including interference that may cause undesired operation. 0050 Weitergabe sowie Vervielfältigung dieser Unterlage, Ver-wertung und Mitteilung ihres Inhalts nicht gestattet, soweitnicht ausdrücklich zugestanden. Zuwiderhandlungen ver-pflichten zu Schadenersatz. Alle Rechte vorbehalten, insbe-sondere für den Fall der Patenterteilung oder GM-Eintragung. The reproduction, transmission or use of this document or its contentsis not permitted without express written authority.Offenders will be liable for damages. All rights including rightscreated by patend grand or registration of a utillity model or design,are reserved. 12345678910 13456710289 A B C D E F G A B C D E F G 0 0 Index No. Änderung Revision Datum Date Name Name A2 Zeichnungs-Nr.: Drawing-No.: 0,333 SAP NR./No.: XRpad 4336 Productdrawing Maßstab Scale Benennung/Title : Gepr. von Checked by RoHS&REACH compliant Gez. von Drawn by Datum Date Name Name Werkstoff Material Freimaßtoleranzen nach DIN ISO 2768-1f Form-u. Lagetoleranzen nach DIN 7168 H-E Dimension Tolerances Änderungen im Zuge des technischen Fortschrittes vorbehalten. Specifications are subject to modification and revision without notice. ACHTUNG: Maßstabsänderungen durch Ausdruck möglich Note: Printing may change scale Oberflächen nach DIN ISO 1302 Surfaces DIN ISO 1302 Kantenzustände nach DIN 6784 Edgepreparations DIN 6784 Beschichtung und Sonderangaben: Coating and special information: Active Area: 432mm x 355,6mm A A A A Pushbutton 40 Connector 101,3 Display 173,8 Antenna 403,8 15 383,6 460 Antenna 41,8 Battery 192,4 Antenna 341,8 214 Weitergabe sowie Vervielfältigung dieser Unterlage, Ver-wertung und Mitteilung ihres Inhalts nicht gestattet, soweitnicht ausdrücklich zugestanden. Zuwiderhandlungen ver-pflichten zu Schadenersatz. Alle Rechte vorbehalten, insbe-sondere für den Fall der Patenterteilung oder GM-Eintragung. The reproduction, transmission or use of this document or its contentsis not permitted without express written authority.Offenders will be liable for damages. All rights including rightscreated by patend grand or registration of a utillity model or design,are reserved. 12345678910 13456710289 A B C D E F G A B C D E F G Index No. Änderung Revision Datum Date Name Name A2 Zeichnungs-Nr.: Drawing-No.: LAE-001417-PRODUCTDRAWING_02 0,333 SAP NR./No.: XRpad 4336 Productdrawing Maßstab Scale Benennung/Title : Gepr. von Checked by RoHS compliant Gez. von Drawn by Datum Date Name Name Werkstoff Material Freimaßtoleranzen nach DIN ISO 2768-1f Form-u. Lagetoleranzen nach DIN 7168 H-E Dimension Tolerances Änderungen im Zuge des technischen Fortschrittes vorbehalten. Specifications are subject to modification and revision without notice. ACHTUNG: Maßstabsänderungen durch Ausdruck möglich Note: Printing may change scale Oberflächen nach DIN ISO 1302 Surfaces DIN ISO 1302 Kantenzustände nach DIN 6784 Edgepreparations DIN 6784 Beschichtung und Sonderangaben: Coating and special information: Battery case this side Place label here PerkinElmer Logo this corner 10±2 156,8±2
Internal Photos 1 XRpad 4336 and XRpad 4336 MED Analog Electronics Board Interface Board Digital Electronics Board Radio Module Internal Photos 2 Radio Module
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. 731 Enterprise Drive Lexington, KY 40510 Telephone: 859-226-1000 Facsimile: 859-226-1040 www.intertek-etlsemko.com TEST REPORT Report Number: 101309482LEX-001 Project Number: G101309482 Evaluation of Model Number: XRpad 4336 and XRpad 4336 MED FCCID: 2AA8Z-XRPAD4336 ICID: 11552A-XRPAD4336 Tested to the SAR Criteria in FCC OET Bulletin 65, Supplement C (Edition 01-01) Industry Canada RSS-102 Issue 4 For Perkin Elmer Medical Imaging Test Performed by: Test Authorized by: Intertek 731 Enterprise Drive Lexington, KY 40510 Perkin Elmer Medical Imaging In der Rehbach 22 65396 Walluf Germany, Prepared By:_______________________________Date:____12/18/2013________ Bryan Taylor, Team Leader Approved By:______________________________Date:____12/18/2013_________ Jason Centers, Senior Project Engineer 731 Enterprise Drive, Lexington KY 40510 Evaluation For:Perkin Elmer Medical Imaging Model Number: XRpad 4336 and XRpad 4336 MED Report Number: 101309482LEX-001 Page 2 of 50 TABLE OF CONTENTS 1.0 DOCUMENT HISTORY ................................................................................................................ 3 2.0 INTRODUCTION ............................................................................................................................ 4 M ODIFICATIONS MADE TO TEST SAMPLE .................................................................................................. 4 3.0 TEST SITE DESCRIPTION ........................................................................................................... 5 MEASUREMENT EQUIPMENT ..................................................................................................................... 6 MEASUREMENT UNCERTAINTY ................................................................................................................ 7 4.0 JOB DESCRIPTION ....................................................................................................................... 9 5.0 SYSTEM VERIFICATION .......................................................................................................... 10 S YSTEM VALIDATION.............................................................................................................................. 10 TISSUE SIMULATING LIQUID DESCRIPTION AND VALIDATION ............................................................... 11 6.0 EVALUATION PROCEDURES .................................................................................................. 13 TEST POSITIONS: ..................................................................................................................................... 13 REFERENCE POWER MEASUREMENT: ..................................................................................................... 13 AREA SCAN: ............................................................................................................................................ 13 Z OOM SCAN: ........................................................................................................................................... 13 I NTERPOLATION, EXTRAPOLATION AND DETECTION OF MAXIMA: ........................................................ 15 P OWER DRIFT MEASUREMENT: .............................................................................................................. 16 RF AMBIENT ACTIVITY:.......................................................................................................................... 16 7.0 CRITERIA ...................................................................................................................................... 17 8.0 TEST CONFIGURATION ............................................................................................................ 17 9.0 TABULAR TEST RESULTS ........................................................................................................ 17 10.0 REFERENCES ........................................................................................................................... 19 11.0 APPENDIX – SAR PLOTS ....................................................................................................... 20 12.0 APPENDIX – SYSTEM VALIDATION DIPOLE PLOTS .................................................... 48 13.0 APPENDIX – SYSTEM VALIDATION SUMMARY ............................................................ 50 731 Enterprise Drive, Lexington KY 40510 Evaluation For:Perkin Elmer Medical Imaging Model Number: XRpad 4336 and XRpad 4336 MED Report Number: 101309482LEX-001 Page 3 of 50 1.0 DOCUMENT HISTORY Revision/ Project Number Writer Initials Date Change 1.0 /G101309482 BCT 12/18/2013 Original document 731 Enterprise Drive, Lexington KY 40510 Evaluation For:Perkin Elmer Medical Imaging Model Number: XRpad 4336 and XRpad 4336 MED Report Number: 101309482LEX-001 Page 4 of 50 2.0 INTRODUCTION At the request of Perkin Elmer Medical Imaging, the XRpad 4336 was evaluated for SAR in accordance with the requirements for RF Exposure compliance testing defined in FCC OET Bulletin 65, Supplement C (Edi…
Text truncated - open the document above for the full version.
EMC Report for PerkinElmer Medical Imaging on the XRpad 4336 and XRpad 4336 MED File: 101287079MPK-003 Page 1 of 96 TEST REPORT Report Number: 101287079MPK-003 Project Number: G101287079 September 29, 2013 Testing performed on the Digital X-Ray Detector System Model Numbers: XRpad 4336 and XRpad 4336 MED FCC ID: 2AA8Z-XRPAD4336 IC: 11552A-XRPAD4336 to FCC Part 15, Subpart E RSS-210 Issue 8 FCC Part 15, Subpart B Industry Canada ICES-003 For PerkinElmer Medical Imaging Test Performed by: Test Authorized by: Intertek 1365 Adams Court Menlo Park, CA 94025 USA PerkinElmer Medical Imaging In der Rehbach 22 65396 Walluf Germany Prepared by: Date: September 29, 2013 Minh Ly Reviewed by: Date: September 29, 2013 Krishna K Vemuri This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. This report must not be used to claim product endorsement by A2LA, NIST nor any other agency of the U.S. Government. EMC Report for PerkinElmer Medical Imaging on the XRpad 4336 and XRpad 4336 MED File: 101287079MPK-003 Page 2 of 96 VERIFICATION OF COMPLIANCE Report No. 101287079MPK-003 Verification is hereby issued to the named APPLICANT and is VALID ONLY for the equipment identified hereon for use under the rules and regulations listed below. Equipment Under Test: Digital X-Ray Detector System Trade Name: PerkinElmer Medical Imaging Model No.: XRpad 4336 Serial No.: zzz – E0019 Applicant: PerkinElmer Medical Imaging Contact: Richard L Knispel Address: In der Rehbach 22 65396 Walluf Country Germany Tel. Number: +496123971507 Email: [email protected] Applicable Regulation: FCC Part 15, Subpart E RSS-210 Issue 8 FCC Part 15, Subpart B Industry Canada ICES-003 Date of Test: July 31 to September 13, 2013 We attest to the accuracy of this report: Minh Ly EMC Project Engineer Krishna K Vemuri EMC Senior Staff Engineer EMC Report for PerkinElmer Medical Imaging on the XRpad 4336 and XRpad 4336 MED File: 101287079MPK-003 Page 3 of 96 TABLE OF CONTENTS 1.0 Introduction .................................................................................................................................... 4 1.1 Summary of Tests ............................................................................................................... 4 2.0 General Description ....................................................................................................................... 5 2.1 Product Description ............................................................................................................ 5 2.2 Related Submittal(s) Grants ................................................................................................ 7 2.3 Test Methodology ............................................................................................................... 7 2.4 Test Facility ........................................................................................................................ 7 2.5 Measurement Uncertainty ................................................................................................... 7 3.0 System Test Configuration ............................................................................................................ 8 3.1 Support Equipment ............................................................................................................. 8 3.2 Block Diagram of Test Setup .............................................................................................. 8 3.3 Justification ......................................................................................................................... 9 3.4 Mode of Operation During Test .......................................................................................... 9 3.5 Modifications required for Compliance .............................................................................. 9 3.6 Additions, deviations and exclusions from standards ......................................................... 9 4.0 Measurement Results ................................................................................................................... 10 4.1 26-dB Bandwidth and Occupied Bandwidth .................................................................... 10 4.2 Conducted Output Power .................................................................................................. 27 4.3 Peak Power Spectral Density ............................................................................................ 44 4.4 Ratio of the peak excursion of the modulation envelope .................................................. 51 4.5 Transmitter Radiated Emissions ....................................................................................... 57 4.6 Radiated Emissions from Digital Parts and Receiver ....................................................... 85 4.7 Frequency stability ............................................................................................................ 92 4.8 AC Line Conducted Emission .......................................................................................... 94 5.0 List of Test Equipment .........................…
Text truncated - open the document above for the full version.
Setup Photographs FCC ID: 2AA8Z-XRPAD4336 IC: 11552A-XRPAD4336 Radiated Emissions Radiated Emissions Side A Side B Side C
1365 Adams Court · Menlo Park · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15E | 5.18 GHz - 5.24 GHz | 23.00 mW |

802.11n 3T3R Mini PCIe Module
Equipment Class
NII - Unlicensed National Information Infrastructure TX
802.11n 3T3R Mini PCIe Module
Equipment Class
NII - Unlicensed National Information Infrastructure TX