FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Inspectron Inc./
  3. 2AADC-RCMA

2AADC-RCMAROCAM mini HD

Inspectron Inc.
ROCAM mini HD - FCC ID 2AADC-RCMA - Inspectron Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 18, 2023
Application Purpose
Original Equipment
Date of Application
Nov 18, 2023
Equipment Note
ROCAM mini HD
Frequency Range
2412.00000000 - 2462.00000000
Company
Inspectron Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ROCAM mini HD AMPShare rothenberger.com ROCAM mini HD AMPShare DE Bedienungsanleitung EN Instructions for use FR Instruction d’utilisation ES Instrucciones de uso IT Istruzioni d’uso NL Gebruiksaanwijzing PT Instruções de serviço DA Brugsanvisning SV Bruksanvisning NO Bruksanvisning FI Käyttöohje PL Instrukcja obsługi CS Návod k používání TR Kullanim kilavuzu HU Kezelési útmutató SL Navodilo za uporabo SK Návod na obsluhu HR Upute za uporabu BG Инструкция за експлоатация RO Manualului de utilizare ET Kasutusjuhend läbi LT Naudojimo instrukciją LV Lietošanas pamācība EL Οδηγίες χρήσεως RU Инструкция по использованию UK Інструкція з експлуатації AR ZH 使用说明书 JA マニュアル Overview A 1 10 8 2 3 4 5 9 5.1 11 12 6 7 no. 1300007159 ROLOC Plus AMPShare no. 1300007160 Basis Modul no. 1300007165 Modul 25/22 HD Intro DEUTSCH - Originalbetriebsanleitung! Bedienungsanleitung bitte lesen und aufbewahren! Nicht wegwerfen! Bei Schäden durch Bedienun gsfehler erlischt die Garantie! Technische Änderungen vorbehalten! Seite 2 ENGLISH Please read and retain these directions for use. Do not throw them away! The warranty does not cover dama ge caused by incorrect use of the equipment! Subject to technical modifications! Page 14 FRANÇAIS Lire attentivement le mode d’emploi et le ranger à un endroit sûr! Ne pas le jeter! La garantie est annulée lors de dommages dûs à une manipulation erronée! Sous réserve de modifications techniques! Page 26 ESPAÑOL ¡Por favor, lea y conserve el manual de instrucciones! ¡No lo tire! ¡En caso de daños por errores de mane jo, la garantía queda sin validez! Modificaciones técnicas reservadas! Página 38 ITALIANO Per favore leggere e conservare le istruzioni per l ́uso! Non gettarle via! In caso di danni dovuti ad errori nell ́uso, la garanzia si estingue! Ci si riservano modifiche tecniche! Pagina 50 NEDERLANDS Lees de handleiding zorgvuldig door en bewaar haar goed! Niet weggooien! Bij schade door bedieningsfouten komt de garantieverlening te vervallen! Technische wijzigingen voorbehouden! Bladzijde 62 PORTUGUES Queiram ler e guardar o manual de instruções! Não deitar fora! Em caso de avarias por utilização incorrecta, extin gue-se a garantia! Reservado o direito de alterações técnicas! Pagina 74 DANSK Læs betjeningsvejledningen, og gem den til senere brug! Smid den ikke ud! Skader, som måtte opstå som følge af betjeningsfejl, medfører, at garantien mister sin gyldighed! Ret til tekniske ændrin ger forbeholdes! Side 86 SVENSKA Läs igenom bruksanvisningen och förvara den väl! Kasta inte bort den! Garantin upphör om apparaten har använts eller betjänats på ett felaktigt sätt! Med reservation för tekniska ändringar! Sida 97 NORSK Les bruksanvisningen og oppbevar den vel! Ikke kast den! Oppstår skader på grunn av bet jeningsfeil opphører garantiens gyldighet! Tekniske forandringer forbeholdes! Side 108 SUOMI Lue ja säilytä tämä käyttöohje! Älä heitä pois! Takuu ei kata käyttövirheistä aiheutuvia vahinkoja! Oikeudet teknisiin muutoksiin pidätetään! Sivulta 119 POLSKI Instrukcję obslugi proszę przeczytać i zachować! Nie wyrzucać! Przy uszkodzeniach wynikajacych z blędów obsłu gi wygasa gwarancja! Zmiany techniczne zastrzeżone! Strony 130 CESKY Navod k obsluze si prosim přečtěte a uschovejte jej! Nevyhazujte jej! V pripade poškozeni zpusobenem ch ybnou obsluhou zanika zaruka! Technicke změny jsou vyhrazeny! Stránky 142 TÜRKÇE Kullanim açiklamalarini lütfen dikkatlice okuyunuz ve bir yerde muhafaza ediniz! Çöpe atmayiniz! Kullaniminda yapilan hatalar, garantinin silinmesine neden olur! Teknik deðiþiklikler yapma hakkimiz saklidir! Sayfa 153 MAGYAR Kérjük, olvassa el és őrizze meg a kezelési utasítást! Ne dobja el! A helytelen kezelésből származó károsodások esetén megszûnik a jótállás! Mûszaki változtatások fenntartva! Oldaltól 164 SLOVENSKO Preberite navodila za uporabo in jih shranite! Ne odvrzite jih! Ob poškodbah zaradi napak v uporabi preneha vel jati garancija! Pridržujemo si pravico do tehničnih sprememb! Stran 176 SLOVENSKÝ Prečítajte si prosím návod na obsluhu a uschovajte ho! Návod nezahadzujte! Pri poškodeniach v dôsledku chýb pri obsluhe zaniká záruka! Technické zmeny vyhradené! Strana 187 HRVATSKI Molimo da pročitate i spremite upute za uporabu! Nemojte ih baciti! Kod kvarova zbog po grešne uporabe odbacuje se jamstvo! Zadržavamo pravo tehničkih izmjena! Stranica 199 БЪЛГАРСКИ Прочетете внимателно и запазете инструкцията за експлоатация! Не я захвърляйте или унищожавайте! При настъпили дефекти вследствие на неправилно обслужване гаранцията отпада! Технически изменения по уреда са изключително в компетенцията на фирмата производител! Страница 210 Intro ROMÂNESC Vă rugăm să citiţi şi să păstraţi manualul de utilizare! Nu îl aruncaţi! În cazul deteriorărilor cauzate de erori de operare, garanţia se pierde! Ne rezervăm dreptul de a efectua modificări tehnice! Pagina 222 ESTU Palun lugege kasutusjuhend läbi ja hoidke alles! Ärge visake ära! Kä-sitsemisvigadest tingitud kah justuste korral kaotab garantii kehtivuse! Õigus tehnilisteks muudatusteks reserveeritud! Lehekülg 234 LIETUVOS Perskaitykite naudojimo instrukciją ir pasilikite ją! Neišmeskite! Garan-tija nebus taikoma gedimams, atsiradusiems dėl netinkamo naudojimo! Pasiliekama teisė daryti techninius pakeitimus! Pusla-pis 245 LATVIEŠU Lūdzu, izlasiet un uzglabājiet lietošanas instrukciju! Nemest prom! Ja ir bojājumi ekspluatācijas k ļūdas dēļ, garantija zaudē spēku! Paturēt tehniskas izmaiņas! Lappuse 256 ΕΛΛΗΝΙΚΑ Οδηγίες χειρισμού παρακαλείσθε να τις διαβάσετε και να τις φυλάσσετε! Μην τις πετάξετε! Σε ζημιες από σφάλματα χειρισμού παυει να ισχύει η εγγύηση! Με επιφύλα ξη για τεχνικές αλλαγές! Σελίδα 268 PУCCKИЙ Прочтите инструкцию по эксплуатации и сохраняйте её для дальнейшего использования! B случае поломки инструмента из-за несоблюдения инструкции клиент теряет право на обсл уживание по гарантии! Bозможны технические изменения! Страница 280 УКРАЇНСЬКА Уважно прочитайте і дотримуйтеся інструкції з експлуатації! Не викидайте ї…

Text truncated - open the document above for the full version.

Attestation Statements

Rev 1/26/2023 Inspectron Inc. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 06‐20‐2023 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2AADC‐RCMA [Insert applicant name] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Robert James Till Compliance Manager Inspectron Inc. Rev 1/26/2023 Inspectron Inc. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 06‐20‐2023 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2AADC‐RCMA [Insert applicant name] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. The applicant is not a named entity or any of its subsidiaries or affiliates to the attestation. Sincerely, Robert James Till Compliance Manager Inspectron Inc.

Attestation Statements

Rev 1/26/2023 Inspectron Inc. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 06‐20‐2023 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: 2AADC‐RCMA Inspectron Inc. (“the applicant”) certifies that, as of the date of the filing of the application, we designate ourselves as the U.S. agent for service of process. Designated U.S. Agent Information: FRN: 0022715650 Name: Inspectron Inc. Address: 29108 Lorie Lane, Wixom MI 48393, USA Contact: Robert James Till Tel.: +1(248)702‐6600 Email: [email protected] Sincerely, Robert James Till Compliance Manager Inspectron Inc.

External Photos

Appendix-ROCAM mini HD-Basis AMP-Photos Page 3 of 10 2. Photographs –Constructional Details 2.1. EUT – External View Model ROCAM mini HD-Basis AMP FCC ID: 2AADC-RCMA Appendix-ROCAM mini HD-Basis AMP-Photos Page 4 of 10 Appendix-ROCAM mini HD-Basis AMP-Photos Page 5 of 10 Appendix-ROCAM mini HD-Basis AMP-Photos Page 6 of 10

Internal Photos

Appendix-ROCAM mini HD-Basis AMP-Photos Page 7 of 10 2.2. EUT – Internal View Model ROCAM mini HD-Basis AMP FCC ID: 2AADC-RCMA ANT Appendix-ROCAM mini HD-Basis AMP-Photos Page 8 of 10 Appendix-ROCAM mini HD-Basis AMP-Photos Page 9 of 10 Appendix-ROCAM mini HD-Basis AMP-Photos Page 10 of 10

RF Exposure Info

Page: 1/13 Ref : ACR.104.1.23.SATU.A Calibrated at MVG Z.I. de la pointe du diable Technopôle Brest Iroise – 295 avenue Alexis de Rochon 29280 PLOUZANE - FRANCE Calibration date: 08/20/2023 Accreditations #2-6789 and #2-6814 Scope available on www.cofrac.fr The use of the Cofrac brand and the accreditation references is prohibited from any reproduction. Summary: This document presents the method and results from an accredited SAR reference dipole calibration performed in MVG using the COMOSAR test bench. All calibration results are traceable to nationa l metrology institutions. SAR Reference Dipole Calibration Report Waltek Testing Group (Shenzhen) Co., Ltd. 1/F, Building A, Hongwei Industrial Park, Liuxian 2 nd Road BAO'AN DISTRICT SHENZHEN, P.R.C. (518101) MVG COMOSAR REFERENCE DIPOLE FREQUENCY: 2450 MHZ SERIAL NO.: SN 13/15 DIP 2G450-364 SAR REFERENCE DIPOLE CALIBRATION REPORT Ref: ACR.104.1.23.SATU.A Page: 2/13 Template_ACR.DDD.N.YY.MVGB.ISSUE_SAR Reference Dipole vJ This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. NameFunctionDateSignature Prepared by :Jérôme LucTechnical Manager 08/20/2023 Checked by :Jérôme LucTechnical Manager 08/20/2023 Approved by:Yann ToutainLaboratory Director 08/20/2023 Customer Name Distribution : IssueNameDateModifications AJérôme Luc 08/20/2023 Initial release 2023.08.20 11:56:55 +01'00' Waltek Testing Group (Shenzhen) Co., Ltd. SAR REFERENCE DIPOLE CALIBRATION REPORT Ref: ACR.104.1.23.SATU.A Page: 3/13 Template_ACR.DDD.N.YY.MVGB.ISSUE_SAR Reference Dipole vJ This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. TABLE OF CONTENTS 1 Introduction ................................................................................................................ 4 2 Device Under Test ..................................................................................................... 4 3 Product Description ................................................................................................... 4 3.1 General Information _______________________________________________________ 4 4 Measurement Method ................................................................................................ 5 4.1 Return Loss Requirements __________________________________________________ 5 4.2 Mechanical Requirements ___________________________________________________ 5 5 Measurement Uncertainty .......................................................................................... 5 5.1 Return Loss ______________________________________________________________ 5 5.2 Dimension Measurement ___________________________________________________ 5 5.3 Validation Measurement ____________________________________________________ 5 6 Calibration Measurement Results .............................................................................. 6 6.1 Return Loss and Impedance In Head Liquid ____________________________________ 6 6.2 Return Loss and Impedance In Body Liquid ____________________________________ 6 6.3 Mechanical Dimensions ____________________________________________________ 7 7 Validation measurement ............................................................................................ 7 7.1 Head Liquid Measurement __________________________________________________ 8 7.2 SAR Measurement Result With Head Liquid ____________________________________ 8 7.3 Body Liquid Measurement _________________________________________________ 11 7.4 SAR Measurement Result With Body Liquid __________________________________ 12 8 List of Equipment .................................................................................................... 13 SAR REFERENCE DIPOLE CALIBRATION REPORT Ref: ACR.104.1.23.SATU.A Page: 4/13 Template_ACR.DDD.N.YY.MVGB.ISSUE_SAR Reference Dipole vJ This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. 1 INTRODUCTION This document contains a summary of the requirements set forth by the IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards for reference dipoles used for SAR measurement system validations and the measurements that were performed to verify that the product complies with the fore mentioned standards. 2 DEVICE UNDER TEST Device Under Test Device Type COMOSAR 2450 MHz REFERENCE DIPOLE Manufacturer MVG Model SID2450 Serial Number SN 13/15 DIP 2G450-364 Product Condition (new / used) New 3 PRODUCT DESCRIPTION 3.1 GENERAL INF ORMATION MVG’s COMOSAR Validation Dipoles are built in accordance to the IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards. The product is designed for use with the COMOSAR test bench only. Figure 1 – MVG COMOSAR Validation Dipole SAR REFERENCE DIPOLE CALIBRATION REPORT Ref: ACR.104.1.23.SATU.A Page: 5/13 Template_ACR.DDD.N.YY.MVGB.ISSUE_SAR Reference Dipole vJ This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. 4 MEASUREMENT METHOD The IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards provide requirements for reference dipoles used for system validation measurements. The following measurements were performed to verify that the product complies with the fore mentioned standards. 4.1 RETURN LOSS REQUIREMENTS The dipole used for SAR system validati…

Text truncated - open the document above for the full version.

RF Exposure Info

Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Page 1 of 44 TEST REPORT Reference No. .................... : WTD23X06128904W003 FCC ID ................................ : 2AADC-RCMA Applicant ........................... : Inspectron Inc. Address.............................. : 29108 Lorie Lane, Wixom, MI 48393 USA Manufacturer ..................... Inspectron Inc. Address.............................. 29108 Lorie Lane, Wixom, MI 48393 USA Product Name ................... : ROCAM mini HD Model No.. .......................... : ROCAM mini HD-Basis AMP Standards .......................... : FCC Part 2.1093, IEEE Std C95.1: 2019 IEEE Std C95.3: 2002 + Rev. 2008 IEC/IEEE 62209-1528 Ed. 1.0 (2020-10) Date of Receipt sample .... : 2023-09-27 Date of Test........................ : 2023-09-27 to 2023-10-09 Date of Issue ..................... : 2023-10-10 Test Report Form No. ....... : WTX_Part2_1093W Test Result ......................... : Pass Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of approver. Prepared By: Waltek Testing Group (Shenzhen) Co., Ltd. Address: 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70 Bao'an District, Shenzhen, Guangdong, China Tel.: +86-755-33663308 Fax.: +86-755-33663309 Email: [email protected] Tested by: Approved by: Jack Sun Silin Chen Reference No.: WTD23X06128904W003 Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Page 2 of 44 TABLE OF CONTENTS 1. General Information ...................................................................................................................................................4 1.1 Product Description for Equipment Under Test (EUT) .........................................................................................4 1.2 Test Standards ....................................................................................................................................................6 1.3 Test Methodology ................................................................................................................................................6 1.4 Test Facility .........................................................................................................................................................6 2. Summary of Test Results ..........................................................................................................................................7 3. Specific Absorption Rate (SAR) ................................................................................................................................8 3.1 Introduction ..........................................................................................................................................................8 3.2 SAR Definition .....................................................................................................................................................8 4. SAR Measurement System ........................................................................................................................................9 4.1 The Measurement System ..................................................................................................................................9 4.2 Probe ...................................................................................................................................................................9 4.3 Probe Calibration Process ................................................................................................................................. 11 4.4 Phantom ............................................................................................................................................................ 11 4.5 Device Holder .................................................................................................................................................... 12 4.6 Test Equipment List ........................................................................................................................................... 13 5. Tissue Simulating Liquids ....................................................................................................................................... 14 5.1 Composition of Tissue Simulating Liquid ........................................................................................................... 14 5.2 Tissue Dielectric Parameters for Head and Body Phantoms ............................................................................. 15 5.3 Tissue Calibration Result ................................................................................................................................... 16 6. SAR Measurement Evaluation ................................................................................................................................ 17 6.1 Purpose of System Performance Check ............................................................................................................ 17 6.2 System Setup .................................................................................................................................................... 17 6.3 Validation Results .............................................................................................................................................. 18 7. EUT Testing Position ............................................................................................................................................... 19 7.1 EUT Antenna Position ....................................................................................................................................... 19 7.2 EUT Testing Posit…

Text truncated - open the document above for the full version.

Test Report

Waltek Testing Group Co., Ltd. http://www.waltek.com.cn Page 1 of 29 TEST REPORT Referen ce No. .................... : WTD23D06128854W003 V1 FCC ID ................................ : 2AADC-RCMA Applicant ............................ : Inspectron Inc. Address .............................. : 29108 Lorie Lane Wixom, MI 48393 USA Manufacturer .................... : Inspectron Inc. Address .............................. : 29108 Lorie Lane Wixom, MI 48393 USA Product ............................... : ROCAM mini HD Model(s). ............................ : ROCAM mini HD-Basis AMP Brand Name. ...................... : Standa rds........................... : FCC 47CFR Part 15.247 Date of Receipt sample .... : 2023-06-15 Date of Test ....................... : 2023-06-15 to 2023-10-23 Date of Issue ...................... : 2023-10-23 Test Result ......................... : Pass Remarks: The re sults shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group Co., Ltd. Address: No. 77, Houjie Section, Guantai Road, Houjie Town, Dongguan City, Guangdong, China Tel: +86-769-2267 6998 Fax: +86-769-2267 6828 Compiled by: Approved by: Estel Qian / Project Engineer Deval Qin / Designated Reviewer Reference No.: WTD23D06128854W003 V1Page 2 of 29 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 2 Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2 CONTENTS ............................................................................................................................................... 2 3 REVISION HISTORY ................................................................................................................................. 3 4 GENERAL INFORMATION ....................................................................................................................... 4 4.1 General Description of E.U.T. ....................................................................................................... 4 4.2 Details of E.U.T. ............................................................................................................................ 4 4.3 Channel List .................................................................................................................................. 4 4.4 Test Facility ................................................................................................................................... 5 4.5 Subcontracted ............................................................................................................................... 5 4.6 Abnormalities from Standard Conditions ...................................................................................... 5 4.7 Test Mode ..................................................................................................................................... 5 5 TEST SUMMARY ...................................................................................................................................... 6 6 EQUIPMENT USED DURING TEST ......................................................................................................... 7 6.1 Equipments List ............................................................................................................................ 7 6.2 Description of Support Units ......................................................................................................... 8 6.3 Measurement Uncertainty ............................................................................................................ 8 6.4 Test Equipment Calibration .......................................................................................................... 8 7 DUTY CYCLE ............................................................................................................................................ 9 8 RADIATED EMISSIONS ......................................................................................................................... 10 8.1 EUT Operation ............................................................................................................................ 10 8.2 Test Setup .................................................................................................................................. 11 8.3 Spectrum Analyzer Setup ........................................................................................................... 12 8.4 Test Procedure ........................................................................................................................... 13 8.5 Corrected Amplitude & Margin Calculation ................................................................................ 13 8.6 Summary of Test Results ........................................................................................................... 14 9 CONDUCTED SPURIOUS EMISSIONS ................................................................................................. 17 9.1 Test Procedure ........................................................................................................................... 17 9.2 Test Result .................................................................................................................................. 18 10 BAND EDGE MEASUREMENT .............................................................................................................. 21 10.1 Test Produce .............................................................................................................................. 21 10.2 Test Result ..............................................................…

Text truncated - open the document above for the full version.

Test Report

Waltek Testing Group Co., Ltd. http://www.waltek.com.cn Page 1 of 59 TEST REPORT Referen ce No. .................... : WTD23D06128854W004 V1 FCC ID ................................ : 2AADC-RCMA Applicant ............................ : Inspectron Inc. Address .............................. : 29108 Lorie Lane Wixom, MI 48393 USA Manufacturer .................... : Inspectron Inc. Address .............................. : 29108 Lorie Lane Wixom, MI 48393 USA Product ............................... : ROCAM mini HD Model(s). ............................ : ROCAM mini HD-Basis AMP Brand Name. ...................... : Standa rds........................... : FCC 47CFR Part 15.247 Date of Receipt sample .... : 2023-06-15 Date of Test ....................... : 2023-06-15 to 2023-10-23 Date of Issue ...................... : 2023-10-23 Test Result ......................... : Pass Remarks: The re sults shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group Co., Ltd. Address: No. 77, Houjie Section, Guantai Road, Houjie Town, Dongguan City, Guangdong, China Tel: +86-769-2267 6998 Fax: +86-769-2267 6828 Compiled by: Approved by: Estel Qian / Project Engineer Deval Qin / Designated Reviewer Reference No.: WTD23D06128854W004 V1 Page 2 of 59 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 2 Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2 CONTENTS ............................................................................................................................................... 2 3 REVISION HISTORY ................................................................................................................................. 3 4 GENERAL INFORMATION ....................................................................................................................... 4 4.1 GENERAL DESCRIPTION OF E.U.T.................................................................................................... 4 4.2 DETAILS OF E.U.T. ......................................................................................................................... 4 4.3 CHANNEL LIST ................................................................................................................................ 4 4.4 TEST FACILITY ................................................................................................................................ 5 4.5 SUBCONTRACTED ........................................................................................................................... 5 4.6 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................ 5 4.7 TEST MODE .................................................................................................................................... 6 5 TEST SUMMARY ...................................................................................................................................... 7 6 EQUIPMENT USED DURING TEST ......................................................................................................... 8 6.1 EQUIPMENTS LIST .................................................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Robert James Till
[email protected]2487026600Fax: 2487026605

Test Firm

WALTEK TESTING GROUP CO., LTD.Joy Zhou
[email protected]0769-22676998

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz58.00 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum conducted output power. The highest reported SAR is 0.39 W/kg. This device supports 20 and 40 MHz bandwidth modes.

Other Applications from Inspectron Inc.

Remote Inspection Tool - FCC ID 2AADC-INS003 - Inspectron Inc.
2AADC-INS003

Remote Inspection Tool

Feb 05, 2015

Equipment Class

DTS - Digital Transmission System
Handheld Inspection Device - FCC ID 2AADC-INS002 - Inspectron Inc.
2AADC-INS002

Handheld Inspection Device

May 15, 2014

Equipment Class

DTS - Digital Transmission System
Digital Wireless Video Scope TX - FCC ID 2AADC-INS001 - Inspectron Inc.
2AADC-INS001

Digital Wireless Video Scope TX

Jul 30, 2013

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter