FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Thermaltake Technology Co., Ltd./
  3. 2AAUCKBPZP

2AAUCKBPZPPOSEIDON Z PLUS

Thermaltake Technology Co., Ltd.
POSEIDON Z PLUS - FCC ID 2AAUCKBPZP - Thermaltake Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 15, 2015
Application Purpose
Original Equipment
Date of Application
Mar 15, 2015
Equipment Note
POSEIDON Z PLUS
Frequency Range
2402.00000000 - 2480.00000000
Company
Thermaltake Technology Co., Ltd.
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

Autho Rules the c r Part 1 Equi p Mode Brand Appli Addre Stand Rep o The te was ( accre techn samp orized under . The produ riteria limits 5, Subpart pment el Name d Name icant ess dard(s) ort(s) est data, da (were) obta dited by the ical standa le and item CE r Declaratio uct listed in Class B o f B, establish POSEIDO KB-PZP Tt eSPO R Thermalta 5F., No.18 FCC Part ANSI C63 ICES-003 CISPR 22 CAN/CS A BTL-FCC E ata evaluati ained utilizi e Authority rd(s). The t (s) tested. B N ERTIF on of Confo follows w a f conducted hed by the F ON Z PLUS RTS By The ake Techno 85, Sec. 2, T 15, Subpar .4-2009 Issue 5: 2 0 : 2008 A-CISPR 22 E-1-141222 on, and equ ng the tes of TAF acc est data co Aut 1, No. 37, L ei-Hu Distri TEL: FAX: ICATE rmity accor as (were) tes d and radia FCC, USA. ermaltake ology Co., L TIDING BLV rt B: 2013 012 -10 21 uipment co st procedure cording to th ontained in t Andy Chi horized Sig BTL INC Lane 365, Y ct, Taipei C +886-2-265 +886-2-265 EOF C rding to 47 sted in the ted emissi o LTD. VD, NEIHU nfiguration es, test ins he ISO-170 the referenc u natory C. Yang-Guang City 114, Taiw 57-3299 57-3331 COMP CFR, Part 2 BTL EMC L ons of the T DIST., TAI contained i struments, 025 quality a ced test rep g St., wan. PLIAN 2 and Part Laboratory Technical S PEI CITY 1 n our test r test sites t assessmen port relate o NCE 15 of the F to comply w Standards F 14, Taiwan report(s) ab that has b t standard only to the E FCC with FCC n ove een and EUT

Internal Photos

Project No.: 1412221 Page 3 of 8 Project No.: 1412221 Page 4 of 8 Antenna Project No.: 1412221 Page 5 of 8 Project No.: 1412221 Page 6 of 8 Project No.: 1412221 Page 7 of 8 Project No.: 1412221 Page 8 of 8

RF Exposure Info

FCC RF EXPOSURE REPORT FCC ID: 2AAUCKBPZP Project No. : 1412221 Equipment : POSEIDON Z PLUS Model : KB-PZP Applicant : Thermaltake Technology Co., LTD. Address : 5F., No.185, Sec. 2, TIDING BLVD, NEIHU DIST., TAIPEI CITY 114, Taiwan According: : FCC Guidelines for Human Exposure IEEE C95.1 BTL Inc. B1, No. 37, Lane 365, YangGuang St., NeiHu District 114, Taipei, Taiwan TEL : (0769) 8318-3000 FAX : (0769) 8319-6000 Table for Filed Antenna Ant. Brand Model NameAntenna TypeConnector Gain(dBi) 1 N/A N/A PCB N/A -3.46 GENERAL CONCULUSION: Maximum measured transmitter power: OutputPower (dBm) Output Power (mW) Limit (mW) -4.45 0.4 10 According to FCC KDB447498 V05, Appendix A, SAR Test Exclusion Thresholds for 100 MHz – 6 GHz and ≤ 50 mm The maximum measured output peak power of this EUT is 0.4mW, less than 10mW at 5mm distance. Conclusion: No SAR evaluation required since transmitter power is below FCC threshold

Test Report

Report No.: BTL-FCCP-1-1412221 Page 1 of 61 FCC Radio Test Report FCC ID: 2AAUCKBPZP This report concerns (check one): Original Grant Class II Change Project No. : 1412221 Equipment : POSEIDON Z PLUS Model Name : KB-PZP Applicant : Thermaltake Technology Co., LTD. Address : 5F., No.185, Sec. 2, TIDING BLVD, NEIHU DIST., TAIPEI CITY 114, Taiwan Date of Receipt : Dec. 31, 2014 Date of Test : Dec. 31, 2014 ~ Feb. 13, 2015 Issued Date : Feb. 16, 2015 Tested by : BTL Inc. Testing Engineer : (Gary Chou) Technical Manager : (Jeff Yang) Authorized Signatory : (Andy Chiu) BTL INC. B1, No.37, Lane 365, Yang Guang St., Nei-Hu District, Taipei City 114, Taiwan. TEL:+886-2-2657-3299 FAX: +886-2- 2657-3331 Report No.: BTL-FCCP-1-1412221 Page 2 of 61 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of R.O.C, or National Institute of Standards and Technology (NIST) of U.S.A. BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL shall have no liability for any declarations, inferences or generalizations drawn by the client or others from BTL issued reports. BTL’s reports must not be used by the client to claim product endorsement by the authorities or an y agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and BTL-self, extracts from the test report shall not be reproduced except in full with BTL’s authorized written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Report No.: BTL-FCCP-1-1412221 Page 3 of 61 Table of Contents Page 1 . CERTIFICATION 6 2 . SUMMARY OF TEST RESULTS 7 2.1 TEST FACILITY 8 2.2 MEASUREMENT UNCERTAINTY 8 3 . GENERAL INFORMATION 9 3.1 GENERAL DESCRIPTION OF EUT 9 3.2 DESCRIPTION OF TEST MODES 11 3.3 TABLE OF PARAMETERS OF TEXT SOFTWARE SETTING 11 3.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 12 3.5 DESCRIPTION OF SUPPORT UNITS 12 4 . EMC EMISSION TEST 13 4.1 CONDUCTED EMISSION MEASUREMENT 13 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 13 4.1.2 TEST PROCEDURE 13 4.1.3 DEVIATION FROM TEST STANDARD 13 4.1.4 TEST SETUP 14 4.1.5 EUT OPERATING CONDITIONS 14 4.1.6 EUT TEST CONDITIONS 14 4.1.7 TEST RESULTS 14 4.2 RADIATED EMISSION MEASUREMENT 15 4.2.1 RADIATED EMISSION LIMITS 15 4.2.2 TEST PROCEDURE 16 4.2.3 DEVIATION FROM TEST STANDARD 16 4.2.4 TEST SETUP 17 4.2.5 EUT OPERATING CONDITIONS 18 4.2.6 EUT TEST CONDITIONS 18 4.2.7 TEST RESULTS (9KHZ TO 30MHZ) 18 4.2.8 TEST RESULTS (BETWEEN 30MHZ TO 1000 MHZ) 19 4.2.9 TEST RESULTS (ABOVE 1000 MHZ) 19 5 . BANDWIDTH TEST 20 5.1 APPLIED PROCEDURES / LIMIT 20 5.1.1 TEST PROCEDURE 20 5.1.2 DEVIATION FROM STANDARD 20 5.1.3 TEST SETUP 20 5.1.4 EUT OPERATION CONDITIONS 20 5.1.5 EUT TEST CONDITIONS 20 5.1.6 TEST RESULTS 20 Report No.: BTL-FCCP-1-1412221 Page 4 of 61 Table of Contents Page 6 . MAXIMUM OUTPUT POWER TEST 21 6.1 APPLIED PROCEDURES / LIMIT 21 6.1.1 TEST PROCEDURE 21 6.1.2 DEVIATION FROM STANDARD 21 6.1.3 TEST SETUP 21 6.1.4 EUT OPERATION CONDITIONS 21 6.1.5 EUT TEST CONDITIONS 21 6.1.6 TEST RESULTS 21 7 . ANTENNA CONDUCTED SPURIOUS EMISSION 22 7.1 APPLIED PROCEDURES / LIMIT 22 7.1.1 TEST PROCEDURE 22 7.1.2 DEVIATION FROM STANDARD 22 7.1.3 TEST SETUP 22 7.1.4 EUT OPERATION CONDITIONS 22 7.1.5 EUT OPERATION CONDITIONS 22 7.1.6 TEST RESULTS 22 8 . POWER SPECTRAL DENSITY TEST 23 8.1 APPLIED PROCEDURES / LIMIT 23 8.1.1 TEST PROCEDURE 23 8.1.2 DEVIATION FROM STANDARD 23 8.1.3 TEST SETUP 23 8.1.4 EUT OPERATION CONDITIONS 23 8.1.5 EUT TEST CONDITIONS 23 8.1.6 TEST RESULTS 23 9 . MEASUREMENT INSTRUMENTS LIST 24 10 . EUT TEST PHOTO 26 ATTACHMENT A - CONDUCTED EMISSION 30 ATTACHMENT B - RADIATED EMISSION (9KHZ TO 30MHZ) 33 ATTACHMENT C - RADIATED EMISSION (30MHZ TO 1000MHZ) 35 ATTACHMENT D - RADIATED EMISSION (ABOVE 1000MHZ) 38 ATTACHMENT E - BANDWIDTH 51 ATTACHMENT F - MAXIMUM OUTPUT POWER TEST 54 ATTACHMENT G - ANTENNA CONDUCTED SPURIOUS EMISSION 55 ATTACHMENT H - POWER SPECTRAL DENSITY TEST 59 Report No.: BTL-FCCP-1-1412221 Page 5 of 61 REPORT ISSUED HISTORY Issued No. Description Issued Date BTL-FCCP-1-1412221 Original Issue. Feb. 16, 2015 Report No.: BTL-FCCP-1-1412221 Page 6 of 61 1. CERTIFICATION Equipment : POSEIDON Z PLUS Brand Name : Tt eSPORTS By Thermaltake Model Name : KB-PZP Applicant : Thermaltake Technology Co., LTD. Manufacturer : MONTEREY International Crop. Address : No.28, Wuquan 6th Rd. Wugu Dist., New Taipei City 24889 Taiwan (R.O.C.) Date of Test : Dec. 31, 2014 ~ Feb. 13, 2015 Test Sample : ENGINEERING SAMPLE Standard(s) : FCC Part15, Subpart C :2013 (15.247) / ANSI C63.4-2009 The above equipment has been tested and found compliance with the requirement of the relative standards by BTL Inc. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. BTL-FCCP-1-1412221) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of TAF according to the ISO-17025 quality assessment standard and technical standard(s). Report No.: BTL-FCCP-1-1412221 Page 7 of 61 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standard(s): Applied Standard(s): FCC Part15 (15.247) , Subpart C Standard(s) Section Test Item Judgment Remark 15.207 Conducted Emission PASS 15.247(d) Antenna conducted Spurious Emission PASS…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No.: BTL-FCCP-1-1412221 Page 26 of 61 10. EUT TEST PHOTO Conducted Measurement Photos Report No.: BTL-FCCP-1-1412221 Page 27 of 61 Radiated Measurement Photos 9KHz to 30MHz Report No.: BTL-FCCP-1-1412221 Page 28 of 61 Radiated Measurement Photos 30M to 1000MHz Report No.: BTL-FCCP-1-1412221 Page 29 of 61 Radiated Measurement Photos Above 1000MHz

Contact Information

Applicant

Michael Lin
[email protected]886-2-87975788Fax: 886-2-87975788

Technical Contact

BTL Inc.Steven Lu
[email protected]86-769-83183000

B1, No. 37, Lane 365, YangGuang St., · Taiwan

Non-Technical Contact

BTL Inc.Cathy Wang
[email protected]86-769-83183000

Test Firm

BTL Inc.Andy Chiu
[email protected]886-2-2657-3299Fax: 886-2-2657-3331

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz400.00 µW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Other Applications from Thermaltake Technology Co., Ltd.

Argent M5 Wireless RGB Gaming Mouse - FCC ID 2AAUCGMOTMF - Thermaltake Technology Co., Ltd.
2AAUCGMOTMF

Argent M5 Wireless RGB Gaming Mouse

Jul 08, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Argent M5 Wireless Dongle - FCC ID 2AAUCGMOTMFRX - Thermaltake Technology Co., Ltd.
2AAUCGMOTMFRX

Argent M5 Wireless Dongle

Jul 08, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Contour - FCC ID 2AAUCMGBLKAPBBBK - Thermaltake Technology Co., Ltd.
2AAUCMGBLKAPBBBK

Contour

Feb 25, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
TX-P2 10000mAh Wireless Charging Power Bank - FCC ID 2AAUCPOWPCPCP2BK - Thermaltake Technology Co., Ltd.
2AAUCPOWPCPCP2BK

TX-P2 10000mAh Wireless Charging Power Bank

Dec 21, 2014

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
THERON Plus smart mouse - FCC ID 2AAUCMOTRPWDLO - Thermaltake Technology Co., Ltd.
2AAUCMOTRPWDLO

THERON Plus smart mouse

Dec 21, 2014

Equipment Class

DTS - Digital Transmission System