Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
-1- ENG Product Manual Advanced Maintenance Tools Print Bed adjustment Service Code Informations P. 2 - P. 4 P. 5 P. 6 P. 7 ENG Product name: 3D Printer -2- ENG Filament Slot USB Port LAN Port Speaker Display Panel Extruder Module Z-Axis Front Door Print Bed Remove the print bed fi xing screws and printing module fi xers Power Switch Power Connector Remove the packaging supports Product Manual Overview Important safety Instruction This guide provides details on how to start off your da Vinci 2.1 Duo Plus 3D printer correctly. Please read the instructions before starting to print. • How to open the box safely • How to load fi lament • Getting to know XYZWare software • Do not place the printer in humid or dusty environment such as bathrooms and high traffic areas. • Do not place the printer on a rickety surface and/or inclined position. Printer may fall down/or tumble and it may cause serious injury. • Do not touch the interior of the printer while printing. As it may be hot and include moving parts. Please keep the front door closed during printing to avoid injury. GLUE STICK Ƒ User Quick Guide Ƒ USB Flash Driver Ƒ Decorative Plate x2 Ƒ Cleaning Wire x 5 Ƒ Power Cord Ƒ Glue Stick Ƒ Filament Cartridge x2 Ƒ Cartridge Locker x2 Ƒ USB Cable Ƒ Scraper Ƒ Copper Brush -3- ENG Open the box Initial Settings 1 2 3 4 5 6 7 8 9 Open the box and remove the accessories and the cushion. T ake out the printer by holding the grip holds. Remove plastic bag and tapes. Open the top door, then remove packaging supports and tapes. Remove the print bed fi xing tapes and cushion. Remove the tapes and cardboard. Remove the screw and plastic piece under print bed. Remove the drip tray fi xing tapes. Connect the printer to your PC first using USB cable then turn on the power switch. • After powering on the printer for the fi rst time, complete the simple setup as instructed on the screen. Then select language and press "Next" to proceed. Packing supports x2 Cable tie x1 Tapes x2 A B A B Product Manual G L U E S T I C K P R I N TI N G -4- ENG Install Cartridge 123 4 5 6 Remove the fi lament stopper. Install new fi lament cartridge into the empty slot. Place and push to fi x the cartridge locker to the slot. Select "Filament" > "Cartridge 1" > "Load". Insert fi lament into the guide hole until the printer starts to load fi lament. (When the loading begins, you will hear the sound of motor and can see the fi lament is pulled into the printer.) When fi lament is dripping off the nozzle, tape "OK" to fi nish. If fi lament loading failed, grasping the release arms may help to fi x the issue. Note: Do Not Touch.Do Not Touch. Product Manual Guide Hole 1 Guide Hole 2 Cartridge 2 Cartridge 1 Guide Hole 1 Guide Hole 2 -5- ENG Sample Print Apply glue to print bed before printing. Glued area depends on the flat measurement or object to be printed. 1 2 4 3 Select "Print" > "Sample" on the screen. Select a sample to print, and tap "Print". Finally use a damp cloth to clean the print bed. After the printing is completed and the print bed became cool, use a scraper to take out the object. P R I N T I NG Product Manual -6- ENG 234Filament is unloaded from extruder automatically. Pull fi lament out from the guide hole when prompted. When fi lament is pulled out, press "OK". Remove cartridge locker and the catridge. important safety Instruction Information and usage of the advanced maintenance tools The maintenance tools provided should be only handlde by an adult. Please keep tools away from children. Incorrect handling or maintenance of the printer may cause damage to the product or personal injury. Ý Scraper Scraper is used to remove printed object from print bed when printing fi nished. (Caution: Do not remove the printed object while the print bed is hot.) ï Copper Brush Cooper brush is used to clean and remove moiten filament left on the tip or surface of the extruder(s) and inside the drive gear. When the printer falls to "Calibrate" consistently, please use the cooper brush to clean and remove the fi lament pieces from the extruder(s). ï Cleaning Wire Cleaning wire is used to remove the fi lament left in the path inside the clogged nozzle when the moiten fi lament has affect printing quality. (Caution: Print bed may be hot during cleaning, please keep away from the platform to avoid personal injury.) When cleaning the print nozzle, gear or fi lament path please ensure to keep hands clear of the print bed which may be hot. PRINTING Unload fi lament 1Select "Filament" > "Cartridge1" (or "Cartridge 2") > "Uninstall" on the screen. Note: Please always complete the procedure for "FILAMENT UNLOADING" before changing a new cartridge. Never cut off the fi lament from the extruder to prevent extruders from clogged. Product Manual & Maintenance Tools -7- ENG Specifi cations Know about XYZware Print Technology Fused Filament Fabrication(FFF) Dual Head 15 x 20 x 20 cm 1.75 mm 0.4 mm Touch Panel Buzzer Speaker LED 28.5 Kg 100-240V, 50~60Hz Standard 200 microns Speed 300 microns Ultra fast 400 microns Custom 100-400 microns USB 2.0 x1 WiFi LAN USB Flash Driver Print Head Layer Resolution Setting Filament Diameter Nozzle Diameter Display Indicator Indicator Lighting Weight Connectivity AC Input Build Volume (W x D x H) Feature da Vinci 2.1 Duo Plus 3D Printer Import View Move Rotate Scale Info Remove ExportSavePrintSettingsHelp For Mac OS and Win8 / 8.1 user or software related topics, please visit following webpage for further information and download the proper XYZware version: http://support.xyzprinting.com/downloads ˥ XYZware ˦ is developed by XYZPrinting Inc. It is designed for everyone with or without modeling skill. You can view the model in various perspectives by importing (*.stl) fi le to it. It is also used to print objects from da Vinic 3D printer. XYZWare can be found in the bundle installation disc. To check our latest software updates and further information. Please go to: http://support.xyzprinting.com/manuals 澿 Notice: Some…
Text truncated - open the document above for the full version.
CERTIFICATE OF COMPLIANCE Authorized under Declaration of Conformity according to 47 CFR, Part 2 and Part 15 of the FCC Rules. The product listed in follows was (were) tested in the Neutron EMC Laboratory to comply with the criteria limits Class B of conducted and radiated emissions of the Technical Standards FCC Part 15, Subpart B, established by the FCC, USA. Equipment 3D Printer Model Name da Vinci 2.1 Duo Plus Brand Name XYZPrinting Applicant XYZprinting, Inc. Address 10F., No.99, Sec. 5, Nanjing E. Rd., Songshan Dist., Taipei City 10571, Taiwan (R.O.C.) Standard(s) FCC Part 15, Subpart B: 2013 ANSI C63.4-2009 ICES-003 Issue 5: 2012 CISPR 22: 2008 CAN/CSA-CISPR 22-10 Report(s) NEI-FCCE-1-1404171 The test data, data evaluation, and equipment configuration contained in our test report(s) above was (were) obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of TAF according to the ISO-17025 quality assessment standard and technical standard(s). The test data contained in the referenced test report relate only to the EUT sample and item(s) tested. Andy Chiu Authorized Signatory Neutron Engineering Inc. B1, No. 37, Lane 365, YangGuang St., NeiHu District 114, Taipei, Taiwan. TEL: +886-2-2657-3299 FAX: +886-2-2657-3331
RV-0000000 Project No.: 1404171 Page 2 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 3 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 4 of 59 Neutron Engineering Inc.
3URGXFWRI7KDLODQG ;<=SULQWLQJ,QF 6HULDO1R 噆⏞ ᳇䲭◉教䦉榒⃕∮䢏ᆴ佟ᶻ㗇攎⊶ 80mm 78mm Model No.( ❲噆 / ❲⏞ ) : da Vinci 2.1 Duo Plus AC INPUT( ẋ㴨弟⅌ẋ㴨彺⅌ ) : 100 - 127V~ 4.0A 50/60Hz200 - 240V~ 2.0A 50/60Hz FCC ID : 2AB9W-3F21XCMIIT ID : XXXXXXXXXX XXXXXXXXXXXXXX XXX-XXXXXX R This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received,including interference that may cause undesired operation . ŏŐŕņŔĻġĩŖŏōņŔŔġŐŕʼnņœŘŊŔņġŔőņńŊŇŊņŅĪIJįġńŐōŐœĻIJńĭŖŔņġŘłŕņœġŅŊŔŔŐōŗŊŏňġŊŏŌĭġġŊŏŌġńŐŏŕłŊŏŔġʼnņłŗŚġŎņŕłō ġŊŔġőœŐʼnŊŃŊŕņŅĭġ ġġġłŏŚġŔŊōŊńŐŏņġŐœġŔŊōŐřłŏņġńŐŏŕłŎŊŏłŕŊŐŏġŘŊōġŏŐŕġŃņġłōōŐŘņŅijįġŎłŕņœŊłōĻőņŕĭġŏŰůĮŤŰŷŦųŦťĭġłťũŦŴŪŷŦĭġŸŪŵũŰŶŵġœġŢůŨŭŦĴįġŏŰůĮũŪŨũĮųŪŴŬġŮŢŵŦųŪŢŭĻńŐŎőōŊłŏńņġŕŐġʼnŔŇġĩʼnŢŻŢųťŰŶŴġŔŶţŴŵŢůŤ ŦŴġŇųŦŦĪį ĵįġőŭŦŢŴŦġŪŮűŰųŵġŸŪŵũġŢġųŰŭŭ Label location
RV-0000000 Project No.: 1404171 Page 5 of 59 Neutron Engineering Inc. ANT RV-0000000 Project No.: 1404171 Page 6 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 7 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 8 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 9 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 10 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 11 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 12 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 13 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 14 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 15 of 59 Neutron Engineering Inc.
RV-0000000 Project No.: 1404171 Page 29 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 30 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 31 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 32 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 33 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 34 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 35 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 36 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 37 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 38 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 39 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 40 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 41 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 42 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 43 of 59 Neutron Engineering Inc.
RV-0000000 Project No.: 1404171 Page 16 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 17 of 59 Neutron Engineering Inc. Wi-Fi Module RV-0000000 Project No.: 1404171 Page 18 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 19 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 20 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 21 of 59 Neutron Engineering Inc. Wi-Fi Module RV-0000000 Project No.: 1404171 Page 22 of 59 Neutron Engineering Inc. Wi-Fi Module RV-0000000 Project No.: 1404171 Page 23 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 24 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 25 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 26 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 27 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 28 of 59 Neutron Engineering Inc.
RV-0000000 Project No.: 1404171 Page 44 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 45 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 46 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 47 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 48 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 49 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 50 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 51 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 52 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 53 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 54 of 59 Neutron Engineering Inc. RV-0000000 Project No.: 1404171 Page 55 of 59 Neutron Engineering Inc. ANT1 RV-0000000 Project No.: 1404171 Page 56 of 59 Neutron Engineering Inc. ANT1 RV-0000000 Project No.: 1404171 Page 57 of 59 Neutron Engineering Inc. ANT1 RV-0000000 Project No.: 1404171 Page 58 of 59 Neutron Engineering Inc. ANT2 RV-0000000 Project No.: 1404171 Page 59 of 59 Neutron Engineering Inc. ANT2
Neutron Engineering Inc. FCC RF EXPOSURE REPORT FCC ID: 2AB9W-3F21X Project No. : 1404171 Equipment : 3D Printer Model : da Vinci 2.1 Duo Plus Applicant : XYZprinting, Inc. Address : 10F., No.99, Sec. 5, Nanjing E. Rd., Songshan Dist., Taipei City 10571, Taiwan (R.O.C.) According: : FCC Guidelines for Human Exposure IEEE C95.1 Neutron Engineering Inc. B1, No. 37, Lane 365, YangGuang St., NeiHu District 114, Taipei, Taiwan TEL : (0769) 8318-3000 FAX : (0769) 8319-6000 Neutron Engineering Inc. MPE CALCULATION METHOD: Calculation Method of RF Safety Distance: where: S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Table for Filed Antenna Ant. Brand Model Name Antenna Type Connector Gain (dBi) 1 WIESON GY136HT0131A-001 PIFA IPEX 2.73 2 INPAQ WA-M-LA-02-042 PIFA IPEX 3.77 Neutron Engineering Inc. TEST RESULTS EUT: 3D Printer Model Name : da Vinci 2.1 Duo Plus Temperature: 26 °C Relative Humidity: 46 % Test Voltage : AC 120V/60Hz Test Mode : IEEE 802.11b/2412 MHz, 2437 MHz, 2462 MHz Antenna Gain (dBi) Antenna Gain (numeric) Peak Output Power (dBm) Peak Output Power (mW) Power Density (S) (mW/cm 2 ) Limit of Power Density (S) (mW/cm 2 ) Te s t Result 3.77 2.3823 13.69 23.3884 0.011090481 Complies 3.77 2.3823 13.63 23.0675 0.010938311 Complies 3.77 2.3823 13.17 20.7491 0.009838991 Complies EUT: 3D Printer Model Name : da Vinci 2.1 Duo Plus Temperature: 26 °C Relative Humidity: 46 % Test Voltage : AC 120V/60Hz Test Mode : IEEE 802.11g/2412 MHz, 2437 MHz, 2462 MHz Antenna Gain (dBi) Antenna Gain (numeric) Peak Output Power (dBm) Peak Output Power (mW) Power Density (S) (mW/cm 2 ) Limit of Power Density (S) (mW/cm 2 ) Te s t Result 3.77 2.3823 19.24 83.9460 0.039806171 Complies 3.77 2.3823 18.64 73.1139 0.034669721 Complies 3.77 2.3823 18.65 73.2825 0.034749641 Complies Neutron Engineering Inc. EUT: 3D Printer Model Name : da Vinci 2.1 Duo Plus Temperature: 26 °C Relative Humidity: 46 % Test Voltage : AC 120V/60Hz Test Mode : IEEE 802.11n (20 MHz)/2412 MHz, 2437 MHz, 2462 MHz Antenna Gain (dBi) Antenna Gain (numeric) Peak Output Power (dBm) Peak Output Power (mW) Power Density (S) (mW/cm 2 ) Limit of Power Density (S) (mW/cm 2 ) Te s t Result 3.77 2.3823 18.76 75.1623 0.035641041 Complies 3.77 2.3823 18.34 68.2339 0.032355671 Complies 3.77 2.3823 17.81 60.3949 0.028638511 Complies The calculated distance is 20 cm
RV-0000000 Report No.: NEI-FCCP-1-1404171 Page 1 of 109 Neutron Engineering Inc. Radio Test Report FCC ID: 2AB9W-3F21X This report concerns (check one) : Original Grant Class II Change Issued Date : May 08, 2014 Project No. : 1404171 Equipment : 3D Printer Model Name : da Vinci 2.1 Duo Plus Applicant : XYZprinting, Inc. Address : 10F., No.99, Sec. 5, Nanjing E. Rd., Songshan Dist., Taipei City 10571, Taiwan (R.O.C.) Tested by: Neutron Engineering Inc. EMC Laboratory Date of Receipt: Apr. 16, 2014 Date of Test: Apr. 16, 2014 ~ Apr. 24, 2014 Testing Engineer : (Josh Lin) Technical Manager : (Jeff Yang) Authorized Signatory : (Andy Chiu) Neutron Engineering Inc. B1, No. 37, Lane 365, YangGuang St., NeiHu District 114, Taipei, Taiwan. TEL: +886-2-2657-3299 FAX: +886-2-2657-3331 RV-0000000 Report No.: NEI-FCCP-1-1404171 Page 2 of 109 Neutron Engineering Inc. Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of R.O.C., or National Institute of Standards and Technology (NIST) of U.S.A. Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutron shall have no liability for any declarations, inferences or generalizations drawn by the client or others from Neutron issued reports. Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval. Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. RV-0000000 Report No.: NEI-FCCP-1-1404171 Page 3 of 109 Neutron Engineering Inc. Table of Contents REPORT ISSUED HISTORY 5 1 CERTIFICATION 6 2 . SUMMARY OF TEST RESULTS 7 2.1 TEST FACILITY 8 2.2 MEASUREMENT UNCERTAINTY 8 3 GENERAL INFORMATION 9 3.1 GENERAL DESCRIPTION OF EUT 9 3.2 DESCRIPTION OF TEST MODES 10 3.3 TABLE OF PARAMETERS OF TEXT SOFTWARE SETTING 11 3.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 12 3.5 DESCRIPTION OF SUPPORT UNITS 13 4 CONDUCTED EMISSION 14 4.1 LIMIT 14 4.2 MEASUREMENT INSTRUMENTS LIST 14 4.3 TEST PROCEDURES 15 4.4 TEST SETUP LAYOUT 15 4.5 DEVIATION FROM TEST STANDARD 15 4.6 EUT OPERATING CONDITIONS 16 4.7 TEST RESULTS 17 5 ANTENNA CONDUCTED SPURIOUS EMISSION 19 5.1 LIMIT 19 5.2 MEASUREMENT INSTRUMENTS LIST 19 5.3 TEST PROCEDURES 19 5.4 TEST SETUP LAYOUT 19 5.5 DEVIATION FROM TEST STANDARD 19 5.6 EUT OPERATING CONDITIONS 19 5.7 TEST RESULTS 20 6 6 DB BANDWIDTH 32 6.1 LIMIT 32 6.2 MEASUREMENT INSTRUMENTS LIST 32 6.3 TEST PROCEDURES 32 6.4 TEST SETUP LAYOUT 32 6.5 DEVIATION FROM TEST STANDARD 32 6.6 EUT OPERATING CONDITIONS 32 6.7 TEST RESULTS 33 7 MAXIMUM PEAK CONDUCTED OUTPUT POWER 39 7.1 LIMIT 39 7.2 MEASUREMENT INSTRUMENTS LIST 39 RV-0000000 Report No.: NEI-FCCP-1-1404171 Page 4 of 109 Neutron Engineering Inc. Table of Contents 7.3 TEST PROCEDURES 39 7.4 TEST SETUP LAYOUT 39 7.5 DEVIATION FROM TEST STANDARD 39 7.6 EUT OPERATING CONDITIONS 39 7.7 TEST RESULTS 40 8 RADIATED SPURIOUS EMISSION (9 KHZ TO 1 GHZ) 43 8.1 LIMIT 43 8.2 MEASUREMENT INSTRUMENTS LIST 44 8.3 MEASURING INSTRUMENTS SETTING 44 8.4 TEST PROCEDURES 45 8.5 DEVIATION FROM TEST STANDARD 45 8.6 TEST SETUP LAYOUT 45 8.7 EUT OPERATING CONDITIONS 46 8.8 TEST RESULTS 47 9 RADIATED SPURIOUS EMISSION (ABOVE 1 GHZ) 49 9.1 LIMIT 49 9.2 MEASUREMENT INSTRUMENTS LIST 50 9.3 MEASURING INSTRUMENTS SETTING 50 9.4 TEST PROCEDURES 51 9.5 DEVIATION FROM TEST STANDARD 51 9.6 TEST SETUP LAYOUT 51 9.7 EUT OPERATING CONDITIONS 52 9.8 TEST RESULTS 53 9.9 TEST RESULTS (RESTRICTED BANDS) 89 10 POWER SPECTRAL DENSITY 101 10.1 LIMIT 101 10.2 MEASUREMENT INSTRUMENTS LIST 101 10.3 TEST PROCEDURES 101 10.4 TEST SETUP LAYOUT 101 10.5 DEVIATION FROM TEST STANDARD 101 10.6 EUT OPERATING CONDITIONS 101 10.7 TEST RESULTS 102 11 EUT TEST PHOTO 108 RV-0000000 Report No.: NEI-FCCP-1-1404171 Page 5 of 109 Neutron Engineering Inc. REPORT ISSUED HISTORY Issue No. Description Issued Date NEI-FCCP-1-1404171 Original Issue. May 08, 2014 RV-0000000 Report No.: NEI-FCCP-1-1404171 Page 6 of 109 Neutron Engineering Inc. 1 CERTIFICATION E q u i p m e n t : 3D Printer Brand Name : XYZPrinting Model Name : da Vinci 2.1 Duo Plus A p p l i c a n t : XYZprinting, Inc. Date of Test : Apr. 16, 2014 ~ Apr. 24, 2014 Standards : FCC Part 15, Subpart C: 2013 ANSI C63.4-2009 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-FCCP-1-1404171) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of TAF according to the ISO-17025 quality assessment standard and technical standard(s). RV-0000000 Report No.: NEI-FCCP-1-1404171 Page 7 of 109 Neutron Engineering Inc. 2. SUMMARY OF TEST RESULTS Standard Clause Test Item Result 15.207 Conducted Emission PASS 15.247 (c) Antenna conducted Spurious Emission PASS 15.247 (a)(2) 6 dB Bandwidth PASS 15.247 (b) Maximum Peak Conducted Output Power PASS 15.247 (c) Radiated Spurious Emission PASS 15.247 (d)(e) Power Spectral Density PASS 15.205 Restricted Ba…
Text truncated - open the document above for the full version.
RV-0000000 Report No.: NEI-FCCP-1-1404171 Page 108 of 109 Neutron Engineering Inc. 11 EUT TEST PHOTO Conducted emission test photos RV-0000000 Report No.: NEI-FCCP-1-1404171 Page 109 of 109 Neutron Engineering Inc. Radiated spurious emission test photos
B1, No. 37, Lane 365, YangGang St., · Taiwan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 84.00 mW |

3D Printer
Equipment Class
DTS - Digital Transmission System
3D Printer
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
3D Printer
Equipment Class
DTS - Digital Transmission System
NFC Module
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
3D Printer
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter