FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. SHENZHEN SURE THING INDUSTRY AND COMMERCE DEVELOPMENT CO.,LTD/
  3. 2ABFFBTC01D

2ABFFBTC01DBluetooth Car Kit

SHENZHEN SURE THING INDUSTRY AND COMMERCE DEVELOPMENT CO.,LTD
Bluetooth Car Kit - FCC ID 2ABFFBTC01D - SHENZHEN SURE THING INDUSTRY AND COMMERCE DEVELOPMENT CO.,LTD
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jun 11, 2020
Application Purpose
Original Equipment
Date of Application
Jun 11, 2020
Equipment Note
Bluetooth Car Kit
Frequency Range
2402.00000000 - 2480.00000000
Company
SHENZHEN SURE THING INDUSTRY AND COMMERCE DEVELOPMENT CO.,LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

Cover Letter(s)

External Photos

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

ID Label/Location Info

Label Location

RF Exposure Info

FCC ID: 2ABFFBTC01D RF Exposure Applicable Standard According to §1.1307(b)(5), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commission’s guideline. This is a Portable device. The Section 4.3.1 and Appendix A of KDB447498 D01 V05 was used as the guidance. Calculation Result (Worse case) High Channel [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ꞏ [√f(GHz)] =0.21/5 * 1.57= 0.066, this value is less than 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR. The SAR measurement is not necessary.

Test Report

Report No.: FCC 2005214-01 File reference No.: 2020-06-05 Applicant: SHENZHEN SURE THING INDUSTRY AND COMMERCE DEVELOPMENT CO.,LTD. Product: Bluetooth Car Kit Model No.: BTC01D, BTC01A,BTC01B,BTC01C,BTC01E,BTC01F Trademark: N/A Test Standards: FCC Part 15.247 Test result: It is herewith confirmed and found to comply with the requirements set up by ANSI C63.10, FCC Part 15.247 for the evaluation of electromagnetic compatibility Approved By Jack Chung Manager Dated: June 05, 2020 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TESTING LABORATORIES Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China Tel (755) 83448688, Fax (755) 83442996, E-Mail:[email protected] Report No.: FCC2005214-01 Page 2 of 51 Date: 2020-06-05 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Special Statement: The testing quality ability of our laboratory meet with “Quality Law of People’s Republic of China” Clause 19. The testing quality system of our laboratory meet with ISO/IEC-17025 requirements, which is approved by CNAL. This approval result is accepted by MRA of APLAC. Our test facility is recognized, certified, or accredited by the following organizations: CNAL-LAB Code: L2292 The EMC Laboratory has been assessed and in compliance with CNAL/AC01:2002 accreditation criteria for testing Laboratories (identical to ISO/IEC 17025:2005 General Requirements) for the Competence of testing Laboratories. FCC-Registration No.: 744189 The EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.: 744189. Industry Canada (IC) —Registration No.:5205A The EMC Laboratory has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 5205A. A2LA (Certification Number:5013.01) The EMC Laboratory has been accredited by the American Association for Laboratory Accreditation (A2LA). Certification Number:5013.01 Report No.: FCC2005214-01 Page 3 of 51 Date: 2020-06-05 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Test Report Conclusion Content 1.0 General Details ................................................................................................ 4 1.1 Test Lab Details................................................................................................ 4 1.2 Applicant Details.............................................................................................. 4 1.3 Description of EUT ........................................................................................... 4 1.4 Submitted Sample.............................................................................................. 4 1.5 Test Duration................................................................................................... 5 1.6 Test Uncertainty............................................................................................... 5 1.7 Test By.......................................................................................................... 5 2.0 List of Measurement Equipment......................................................................... 6 3.0 Technical Details............................................................................................. 7 3.1 Summary of Test Results..................................................................................... 7 3.2 Test Standards.................................................................................................. 7 4.0 EUT Modification.............................................................................................7 5.0 Power Line Conducted Emission Test...................................................................... 8 5.1 Schematics of the Test........................................................................................ 8 5.2 Test Method and Test Procedure............................................................................ 8 5.3 Configuration of the EUT.............................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Conducted Emission Te s t Setup: Radiated Emission Te s t Setup:

Contact Information

Applicant

Xin Chen
[email protected]86-755-26617270Fax: 86-755-26617270

Test Firm

Shenzhen Timeway Testing LaboratoriesTerry Tang
[email protected]+86-755-83448688

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz209.00 µW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted

Other Applications from SHENZHEN SURE THING INDUSTRY AND COMMERCE DEVELOPMENT CO.,LTD

Bluetooth Transmitter and Receiver - FCC ID 2ABFFBTC21 - SHENZHEN SURE THING INDUSTRY AND COMMERCE DEVELOPMENT CO.,LTD
2ABFFBTC21

Bluetooth Transmitter and Receiver

Nov 15, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Bluetooth Receiver - FCC ID 2ABFFBTC21RCA - SHENZHEN SURE THING INDUSTRY AND COMMERCE DEVELOPMENT CO.,LTD
2ABFFBTC21RCA

Bluetooth Receiver

Jun 14, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Bluetooth car speaker phone - FCC ID 2ABFFBTC26 - SHENZHEN SURE THING INDUSTRY AND COMMERCE DEVELOPMENT CO.,LTD
2ABFFBTC26

Bluetooth car speaker phone

Jan 21, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Bluetooth Car Kit - FCC ID 2ABFFBTC01 - SHENZHEN SURE THING INDUSTRY AND COMMERCE DEVELOPMENT CO.,LTD
2ABFFBTC01

Bluetooth Car Kit

Dec 29, 2014

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Bluetooth Headset - FCC ID 2ABFFSH26 - SHENZHEN SURE THING INDUSTRY AND COMMERCE DEVELOPMENT CO.,LTD
2ABFFSH26

Bluetooth Headset

Dec 28, 2014

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter