2ABQ3-SSM003MWireless Scanner Mouse

Systech Electronics Ltd.
Wireless Scanner Mouse - FCC ID 2ABQ3-SSM003M - Systech Electronics Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 14, 2015
Application Purpose
Original Equipment
Date of Application
Jan 14, 2015
Equipment Note
Wireless Scanner Mouse
Frequency Range
2412.00000000 - 2462.00000000
Company
Systech Electronics Ltd.
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

Appendix B Date: 2015-01-06 Report No.: 60.870.14.021.04F Model No.: Zcan Wireless Page 1 of 3 TÜV SÜD Hong Kong Ltd. 3/F, West Wing, Phase 2, 10 Science Park West Avenue, Shatin, Hong Kong. Appendix B Date: 2015-01-06 Report No.: 60.870.14.021.04F Model No.: Zcan Wireless Page 2 of 3 TÜV SÜD Hong Kong Ltd. 3/F, West Wing, Phase 2, 10 Science Park West Avenue, Shatin, Hong Kong. Appendix B Date: 2015-01-06 Report No.: 60.870.14.021.04F Model No.: Zcan Wireless Page 3 of 3 TÜV SÜD Hong Kong Ltd. 3/F, West Wing, Phase 2, 10 Science Park West Avenue, Shatin, Hong Kong.

ID Label/Location Info

Location

Internal Photos

Appendix C Date: 2015-01-06 Report No.: 60.870.14.021.04F Model No.: Zcan Wireless Page 1 of 8 TÜV SÜD Hong Kong Ltd. 3/F, West Wing, Phase 2, 10 Science Park West Avenue, Shatin, Hong Kong. Appendix C Date: 2015-01-06 Report No.: 60.870.14.021.04F Model No.: Zcan Wireless Page 2 of 8 TÜV SÜD Hong Kong Ltd. 3/F, West Wing, Phase 2, 10 Science Park West Avenue, Shatin, Hong Kong. Appendix C Date: 2015-01-06 Report No.: 60.870.14.021.04F Model No.: Zcan Wireless Page 3 of 8 TÜV SÜD Hong Kong Ltd. 3/F, West Wing, Phase 2, 10 Science Park West Avenue, Shatin, Hong Kong. Appendix C Date: 2015-01-06 Report No.: 60.870.14.021.04F Model No.: Zcan Wireless Page 4 of 8 TÜV SÜD Hong Kong Ltd. 3/F, West Wing, Phase 2, 10 Science Park West Avenue, Shatin, Hong Kong. Appendix C Date: 2015-01-06 Report No.: 60.870.14.021.04F Model No.: Zcan Wireless Page 5 of 8 TÜV SÜD Hong Kong Ltd. 3/F, West Wing, Phase 2, 10 Science Park West Avenue, Shatin, Hong Kong. Appendix C Date: 2015-01-06 Report No.: 60.870.14.021.04F Model No.: Zcan Wireless Page 6 of 8 TÜV SÜD Hong Kong Ltd. 3/F, West Wing, Phase 2, 10 Science Park West Avenue, Shatin, Hong Kong. Appendix C Date: 2015-01-06 Report No.: 60.870.14.021.04F Model No.: Zcan Wireless Page 7 of 8 TÜV SÜD Hong Kong Ltd. 3/F, West Wing, Phase 2, 10 Science Park West Avenue, Shatin, Hong Kong. Appendix C Date: 2015-01-06 Report No.: 60.870.14.021.04F Model No.: Zcan Wireless Page 8 of 8 TÜV SÜD Hong Kong Ltd. 3/F, West Wing, Phase 2, 10 Science Park West Avenue, Shatin, Hong Kong.

RF Exposure Info

Date: 2015-01-06 Report No.: 60.870.14.021.01S Model No.:Zcan Wireless Page 1 of 1 TÜV SÜD Hong Kong Ltd. 3/F, West Wing, Phase 2, 10 Science Park West Avenue, Shatin, Hong Kong. SAR Evaluation Exemption Compliance Information The device has a standalone transmission. According to KDB 447498 section 4.3.1, the 1-g SAR test exclusion thresholds at test separation distances ” 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]·[ ¥f(GHz)] ” 3.0 The maximum tune-up limit power is 7.762mW @ 2.412GHz For the head and body SAR, use 50mm as the conservative minimum test separation distance, [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]·[ ¥f(GHz)] = 0.01 ” 3.0 So standalone SAR measurements are not required for both head and body

Test Report

TEST REPORT Date: 2015-01-06 Report No.: 60.870.14.021.04F Page 1 of 35 TUV SUD Hong Kong Ltd. 3/F, West Wing, Phase 2, 10 Science Park West Avenue, Shatin, Hong Kong Applicant:Systech Electronics Ltd. 26/F Lever Tech Centre, 69-71 King Yip Street, Kwun Tong, Kowloon, Hong Kong. Description of Samples:Model name: Wireless Scanner Mouse Brand name: Model no.: Zcan Wireless FCCID:2ABQ3-SSM003M Date Samples Received:2014-11-24 Date Tested:2014-11-24 to 2015-01-05 Investigation Requested:FCC Part 15 Subpart C, Section 15.247 Conclusions:The submitted product COMPLIED with the requirements of Federal Communications Commission [FCC] Rules and Regulations Part 15. The tests were performed in accordance with the standards described above and on Section 2.2 in this Test Report. Remarks:--- Checked by:Approved by:- Ray CheungJeff Pong Project EngineerManager Wireless & Telecom departmentWireless & Telecom department Report No.:60.870.14.021.04F Page 2 of 35 TÜV SÜD Hong Kong Ltd. 3/F, West Wing, Phase 2, 10 Science Park West Avenue, Shatin, Hong Kong CONTENT: Cover Page 1 of 35 Content Page 2-3 of 35 1.0General Details 1.1Test Laboratory Page 4 of 35 1.2Applicant Details Page 4 of 35 1.3Equipment Under Test [EUT] Page 5 of 35 1.4 Related Submittal(s) Grants Page 5 of 35 2.0Technical Details 2.1Investigations Requested Page 6 of 35 2.2Test Standards and Results Summary Page 6 of 35 3.0Test Methodology 3.1Radiated Emission Page 7 of 35 3.2Field Strength Calculation Page 7 of 35 3.3Conducted Emission Page 7 of 35 4.0Test Results 4.1 6dB Bandwidth MeasurementPage 9-14 of 35 4.2 Power Spectral Density Page 15-21 of 35 4.3 Band Edge MeasurementPage 22-24 of 35 4.4 Maximum Output Power Page 25-26 of 35 4.5 Out of Band Emissions and Emissions in Restricted BandsPage 27-33 of 35 4.6 Conducted Emission on AC MainsPage 34 of 35 Report No.:60.870.14.021.04F Page 3 of 35 TÜV SÜD Hong Kong Ltd. 3/F, West Wing, Phase 2, 10 Science Park West Avenue, Shatin, Hong Kong 5.0List of Measurement Equipments Page 35 of 35 Appendix A Photos of Test Setup Appendix B External EUT Photos Appendix C Internal EUT Photos Report No.:60.870.14.021.04F Page 4 of 35 TÜV SÜD Hong Kong Ltd. 3/F, West Wing, Phase 2, 10 Science Park West Avenue, Shatin, Hong Kong 1.0General Details 1.1Test Laboratory STC (Dongguan) Company Ltd. 68 Fumin Nan Rd, Dalang, Dongguan, Guangdong, PRC. Tested By: John Zhi 1.2Applicant Details Applicant Systech Electronics Ltd. 26/F Lever Tech Centre, 69 – 71 King Yip Street, Kwun Tong, Kowloon, Hong Kong. Manufacturers K-Mark Industrial Ltd. Flat A, 7/F., Mai On Ind. Bldg., 17 – 21, Kung Yip St., Kwai Chung, Hong Kong. Report No.:60.870.14.021.04F Page 5 of 35 TÜV SÜD Hong Kong Ltd. 3/F, West Wing, Phase 2, 10 Science Park West Avenue, Shatin, Hong Kong 1.3Equipment Under Test [EUT] Description of EUT Product Description:Wireless Scanner Mouse Model No.:Zcan Wireless Brand Name: FCCID:2ABQ3-SSM003M Rating: DC 3.7V 650mAh Li-ion battery Operated Frequency:2412–2462MHz No. of Operated Channel:11 CH / (802.11b/g/n – HT20) Data Rate:802.11b: 1, 2, 5.5, 11Mbps 802.11g: 6, 9, 12, 18, 24, 36, 48, 54Mbps 802.11n: MCS0-7, up to 150Mbps Modulation:DSSS (BPSK, QPSK, CCK) and OFDM (BPSK/QPSK/16-QAM/ 64-QAM) Accessories and Auxiliary Equipments: ThinkPad Notebook Antenna Type:PCB Antenna Manufacture of Antenna:--- Antenna Gain:2 dBi Antenna Model:--- General Operation of EUT The Equipment Under Test (EUT) is aMousewith scanning function,which include ofan 802.11b/g/n module. Report No.:60.870.14.021.04F Page 6 of 35 TÜV SÜD Hong Kong Ltd. 3/F, West Wing, Phase 2, 10 Science Park West Avenue, Shatin, Hong Kong Description of Test Modes The EUT has been tested under operating condition. Software used to control the EUT for staying in continuous transmitting and receiving mode is programmed. IEEE802.11b: Channel 1(2412MHz), Channel 6(2437MHz) and Channel 11(2462MHz) with 1Mbps data rate (worst case) are chosen for the final testing. IEEE802.11g: Channel 1(2412MHz), Channel 6(2437MHz) and Channel 11(2462MHz) with 6Mbps data rate (the worst case) are chosen for the final testing. IEEE802.11n – HT20: Channel 1(2412MHz), Channel 6 (2437MHz) and Channel 11 (2462MHz) with MSC0 (worst case) are chosen for the final testing. IEEE802.11n – HT40: Channel 3(2422MHz), Channel 6 (2437MHz) and Channel 9 (2452MHz) with MSC0 (worst case) are chosen for the final testing. 1.4Related Submittal(s) Grants This is a signal application subject to Certificate Authorization. Report No.:60.870.14.021.04F Page 7 of 35 TÜV SÜD Hong Kong Ltd. 3/F, West Wing, Phase 2, 10 Science Park West Avenue, Shatin, Hong Kong 2.0Technical Details 2.1Investigations Requested Perform ElectroMagnetic Interference measurement in accordance with FCC 47CFR [Codes of Federal Regulations] Part 15 and ANSI C63.4: 2009 2.2Test Standards and Results Summary Tables Test ConditionTest RequirementTest Result PassN/A Number of Frequency Hopping Section 15.247 ( a1 ) 6dB Bandwidth MeasurementSection 15.247 ( a2 ) Power Spectral Density Section 15.247 ( e ) Pseudorandom Hopping AlgorithmSection 15.247 ( a1 ) Band Edge Measurement Section 15.247 Maximum Output PowerSection 15.247 ( b3 ) Out of Band EmissionSection 15.247 ( d ) Radiated Emission in Restricted BandSection 15.247 ( d ) Conducted Emission on AC MainsSection 15.207 RF ExposureSection 15.247 ( i ) Antenna RequirementSection 15.203 See note 1 Note 1 :The EUT uses a permanently attached antenna, which in accordance to Section 15.203, is considered sufficient to comply with the provisions of this section. Remark: N/A - Not Applicable Report No.:60.870.14.021.04F Page 8 of 35 TÜV SÜD Hong Kong Ltd. 3/F, West Wing, Phase 2, 10 Science Park West Avenue, Shatin, Hong Kong 3.0Test Methodology 3.1Radiated Emission The samplewas placed 0.8m above the ground plane on astandard emission test site *. Measurements in both horizontal and vertical polarities were performed. During the test, each emission was maximized by: having the EUT c…

Text truncated - open the document above for the full version.

Test Setup Photos

Appendix A Date: 2015-01-06 Report No.: 60.870.14.021.04F Model No.:Zcan Wireless Page 1 of 1 TÜV SÜD Hong Kong Ltd. 3/F, West Wing, Phase 2, 10 Science Park West Avenue, Shatin, Hong Kong. Radiated Emission

Contact Information

Applicant

Patrick Lee(C.E.O.)
[email protected]852-2199 5399Fax: 852-2389 0979

Test Firm

STC (Dongguan) Company Ltd.Wilson Wong
[email protected]85226661888Fax: 85226644353

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz8.00 mW
Confidentiality
Long Term
Grant Notes
Output power is conducted. This device and its antenna(s) must not be co-located or operated in conjunction with any antenna or transmitter except in accordance with FCC multi-transmitter RF exposure procedures.

Other Applications from Systech Electronics Ltd.

Wireless Scanner Mouse (Dongle) - FCC ID 2ABQ3-SSM003R - Systech Electronics Ltd.
2ABQ3-SSM003R

Wireless Scanner Mouse (Dongle)

Jan 14, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wireless Tracker - FCC ID 2ABQ3-STG001 - Systech Electronics Ltd.
2ABQ3-STG001

Wireless Tracker

Apr 08, 2014

Equipment Class

DTS - Digital Transmission System