ADC-T2000 User Guide Hub Product Manual Hub Product Manual | 1 Indicator Lights White Flashing: no internet connection, or, not connected to the Building 36 servers Solid: internet connection, connected to the Building 36 servers Green Flashing: Inclusion mode Solid: Successful Inclusion Orange Flashing: Exclusion mode Solid: Successful Exclusion Required • Standard home router with active Internet connection • Z-Wave devices to be installed TIP: To exit Inclusion/Exclusion mode, press the Pairing button (). Set Up 2 | Hub Product Manual Installation Step 1: Install the Hub 1. Plug one end of the Ethernet cable into the LAN port on the Hub. Plug the other end of the Ethernet cable into the network router. 2. Plug in the power supply to the DC IN port on the Hub. • Indicator lights will initially flash and rotate colors during the first few seconds. Wait until only the White light stays solid or continues flashing. • The Hub will then take up to five minutes to register with Building 36 servers. TIP: During this time, install each Z-Wave device around the home. Step 2: Including Z-Wave Devices (adding them to the network) To include Z-Wave devices, each device must be within direct communication range of the Hub. For best results, we recommend having the Hub in the same room as the device you are Including. 1. If necessary, unplug the Hub to move it into direct range of the first Z-Wave device. Provide the Hub with power and wait until only a White Light stays solid or starts flashing. It is OK to disconnect the Ethernet cable during the Inclusion/Exclusion process. 2. Add Z-Wave Devices • Press Pairing button ( ) on the Hub once to put the Hub in Inclusion mode. The light will start flashing Green. • Follow the Z-Wave device’s instructions to put the device into Inclusion mode. Most devices have an Include/Exclude button. • Wait for the flashing Green light to stay solid for 5 seconds to indicated the device has been successfully included. An online account is required prior to installing your Hub. If you do not have an account, contact your Building 36 Professional Partner to create one for you. Hub Product Manual | 3 Troubleshooting Step 3: Complete the Installation 1. Once all devices are Included, reconnect the Hub to the network router with the Ethernet cable and plug in power supply to the Hub. 2. Log into you User Account and navigate to your dashboard. For help, please view our online tutorials at www.building36.com/videos Excluding Z-Wave Devices (removing them from the network) To exclude Z-Wave devices, each device must be within direct communication range of the Hub. For best results, we recommend having Hub in the same room as the device you are Excluding. 1. Press and hold the Pairing button ( ) for 5 seconds until the light flashes Orange to put the Hub in Exclusion mode. While you’re holding the Pairing button, the light will be flashing Green before it turns Orange. 2. Follow the Z-Wave device’s instructions to put the device into Exclusion mode. Most devices have an Include/Exclude button. 3. The flashing Orange light will turn solid to indicate the device has been successfully excluded. Unsuccessful Installation If the Z-Wave device does not add successfully, follow the device removal procedure and then try the Inclusion process again. 4 | Hub Product Manual Notices FCC NOTICE: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. –AND– 2. This device must accept any interference received, including Interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Hub Product Manual | 54 | Hub Product Manual Notices FCC RSS-GEN SEC 7.1.3 NOTICE: This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout broillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular inst…
Text truncated - open the document above for the full version.
! 460!Hillside!Ave! Needham,!MA!02494! ! Building!36!Technologies,!LLC! 460!Hillside!Ave! Needham,!MA!02492! 781B474B0500!/[email protected]!! February 18, 2014 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 To whom it may concern: This letter is to comply with Section 0.457(d)(2)(i) pertaining to confidential material. RF Laboratories would like the following documents regarding this submission for FCC ID: 2AC3T- H200BRA to be kept confidential. 1. All schematics 2. Block diagrams 3. Circuit descriptions The above material contains trade secrets or technical data, which would customarily be guarded from competitors. We do not want these documents to be accessible to the general public. Sincerely, Daniel Goodman
APPLICANT: BUILDING 36 TECHNOLOGIES, LLC FCC ID: 2AC3T-H200BRA IC: 12323A-H200BRA
PMS COOL GRAY 7 CDIE-LINE (DOES NOT PRINT)WHITE Building36 Gateway LABEL Artwork / Scale: 1 = 12-24-2015 Model: B36-H200-B • HW: B36-H200-BB-RA FCC: 2AC3T-H200BRA • IC: 12323A-H200BRA Designed in the USA | Made in China SERIAL/MAC ID LABEL Product Label Serial #: MAC ID: Date Code: Serial / MAC ID Label
PMS COOL GRAY 7 CDIE-LINE (DOES NOT PRINT)WHITE Reliant Gateway LABEL Artwork / Scale: 1 = 12-24-2015 Product Label Serial / MAC ID Label Model: B36-H200-B • HW: B36-H200-BB-RA FCC: 2AC3T-H200BRA • IC: 12323A-H200BRA Designed in the USA | Made in China SERIAL/MAC ID LABEL Serial #: MAC ID: Date Code:
Label affixed here
APPLICANT: BUILDING 36 TECHNOLOGIES, LLC FCC ID: 2AC3T-H200BRA IC: 12323A-H200BRA
RF Exposure Evaluation Report APPLICANT BUILDING 36 TECHNOLOGIES, LLC 35 HIGHLAND CIRCLE SUITE 300 NEEDHAM MA 02494 USA FCC ID 2AC3T-H200BRA MODEL NUMBER B36-H200-B PRODUCT DESCRIPTION GATEWAY STANDARD APPLIED CFR 47 Part 2.1091 PREPARED BY Cory Leverett We, TIMCO ENGINEERING, INC. would like to declare that the device has been evaluated in accordance with 47 CFR Part 2.1091 and meets the requirements. The attached report shall not be reproduced except in full without the written approval of TIMCO ENGINEERING, INC. 849 NW STATE ROAD 45 NEWBERRY, FL 32669 USA PH: 888.472.2424 OR 352.472.5500 FAX: 352.472.2030 EMAIL: [email protected] HTTP://WWW.TIMCOENGR.COM Applicant: BUILDING 36 TECHNOLOGIES, LLC FCC ID: 2AC3T-H200BRA Report: B\BUILDING 36\411AUT15\411AUT15TestReport.docxt Page 2 of 4 GENERAL REMARKS Attestations This equipment has been evaluated in accordance with the standards identified in this report. To the best of my knowledge and belief, these evaluations were performed using the procedures described in this report. I attest that the necessary evaluations were made, under my supervision, at: Timco Engineering Inc. 849 NW State Road 45 Newberry, Fl 32669 Authorized Signatory Name: Cory Leverett Engineering Project Manager Date: 4/16/2015 RF Exposure Requirements General information Device type: GATEWAY Devices that operate under Part 90 of this chapter are subject to RF exposure evaluation prior to equipment authorization or use. Antenna The manufacturer does not specify an antenna, but a typical antenna has a gain of 0 dBi. Configuration Antenna p/n Type Max. Gain (dBi) Integrated PCB Trace Di-Pole 2.15 Operating configuration and exposure conditions: The conducted output power is shown in the table below. Typical use qualifies for a maximum duty cycle factor of 100%. Operation: The EUT uses a fixed PCB trace antenna, therefore there is no cable loss. MPE Calculation: The minimum separation distance is calculated as follows: The limit for general uncontrolled exposure environment is shown in FCC rule Part 1.11310, Table 1. Applicant: BUILDING 36 TECHNOLOGIES, LLC FCC ID: 2AC3T-H200BRA Report: B\BUILDING 36\411AUT15\411AUT15TestReport.docx Max Power 0.0039WequalsMax Power 3.9mW Duty Cycle100%equalsDuty Factor1 numeric Antenna Gain2.81dBiequalsGain numeric1.909853numeric Coax Loss0 dBGain - Coax Loss1.909853numeric Power Density0.6 mW/cm 2 Frequency924MHzFrequency rangPower den Enter this value MHz mW/cm 2 mW/cm 2 0.3-1.34100100 1.34-30 180/f 2 0.0 30-3000.20.2 300-1,500f/15000.6 1,500-100,00011 f = frequency in MHz Minimum Separation Distance1 cm0.01m Minimum Seperation in Inches0.391008Inches Minimum Separation Distance for Mobile or Fixed Devices General Population/Uncontrolled Exposure Insert values in yellow highlighted boxes to determine Minimum Separation Distance Enter power Density from the chart to the rightRule Part 1.1310, Table 1
APPLICANT: BUILDING 36 TECHNOLOGIES, LLC FCC ID: 2AC3T-H200BRA IC Cert#: 12323A-H200BRA REPORT: B\BUILDING 36\411AUT15\411AUT15TestReport.docx Page 2 of 27 FCC PART 15.247 & RSS-210 DIGITAL SPREAD SPECTRUM COMBINED TEST REPORT Applicant BUILDING 36 TECHNOLOGIES, LLC Address 35 HIGHLAND CIRCLE SUITE 300 NEEDHAM MA 02494 USA FCC ID 2AC3T-H200BRA IC Cert # 12323A-H200BRA Model Number B36-H200-B Product Description GATEWAY Date Sample Received 2/27/2015 Date Tested 4/15/2015 Tested By Cory Leverett Approved By Sid Sanders Report Number Version Number Description Issue Date 411AUT15TestReport Rev.1 Initial Issue 4/17/2015 THE ATTACHED REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL WITHOUT THE WRITTEN APPROVAL OF TIMCO ENGINEERING, INC. 849 NW State Road 45 Newberry, FL 32669 USA Ph: 888.472.2424 or 352.472.5500 Fax: 352.472.2030 Email: [email protected] Website: www.timcoengr.com APPLICANT: BUILDING 36 TECHNOLOGIES, LLC FCC ID: 2AC3T-H200BRA IC Cert#: 12323A-H200BRA REPORT: B\BUILDING 36\411AUT15\411AUT15TestReport.docx Page 3 of 27 TABLE OF CONTENT GENERAL REMARKS ............................................................................................................................. 4 TABLE OF CONTENTS ........................................................................................................................... 4 GENERAL INFORMATION ...................................................................................................................... 5 SUMMARY ............................................................................................................................................. 6 POWER OUTPUT ................................................................................................................................... 7 POWER SPECTRAL DENSITY ................................................................................................................. 8 OCCUPIED BANDWIDTH ....................................................................................................................... 9 BANDEDGE ......................................................................................................................................... 13 SPURIOUS EMISSIONS AT ANTENNA TERMINALS .............................................................................. 14 RADIATION INTERFERENCE ............................................................................................................... 18 POWER LINE CONDUCTED INTERFERENCE ...................................................................................... 24 EMC EQUIPMENT LIST........................................................................................................................ 27 APPLICANT: BUILDING 36 TECHNOLOGIES, LLC FCC ID: 2AC3T-H200BRA IC Cert#: 12323A-H200BRA REPORT: B\BUILDING 36\411AUT15\411AUT15TestReport.docx Page 4 of 27 GENERAL REMARKS The attached report shall not be reproduced except in full without the written permission of Timco Engineering Inc. The test results relate only to the items tested. Summary The device under test does: Fulfill the general approval requirements as identified in this test report Not fulfill the general approval requirements as identified in this test report Attestations This equipment has been tested in accordance with the standards identified in this test report. To the best of my knowledge and belief, these tests were performed using the measurement procedures described in this report. All instrumentation and accessories used to test products for compliance to the indicated standards are calibrated regularly in accordance with ISO 17025: 2005 requirements. I attest that the necessary measurements were made, under my supervision, at: Timco Engineering Inc. 849 NW State Road 45 Newberry, FL 32669 Authorized Signatory Name: Cory Leverett Engineering Project Manager Date: 4/17/2015 Table of Contents APPLICANT: BUILDING 36 TECHNOLOGIES, LLC FCC ID: 2AC3T-H200BRA IC Cert#: 12323A-H200BRA REPORT: B\BUILDING 36\411AUT15\411AUT15TestReport.docx Page 5 of 27 GENERAL INFORMATION EUT Specification FCC Regulatory Standard Title 47 CFR Part 15.247 IC Regulatory Standard RSS-210 (i8) FCC ID 2AC3T-H200BRA IC Cert 12323A-H200BRA EUT Description GATEWAY Operating Frequency TX: 912 – 924 MHz RX: 912 – 924 MHz Number of channels 7 EUT Power Source 110–120Vac/50– 60Hz DC Power Battery Operated Exclusively Test Item Prototype Pre- Production Production Type of Equipment Fixed Mobile Portable Antenna Connector None Antenna Fixed 2.81 dBi gain PCB Trace Antenna Test Facility Timco Engineering Inc. located at 849 NW State Road 45 Newberry, FL 32669 USA. Test Conditions Temperature: 24-26ºC Relative humidity: 50-65% Measurement Standard KDB 558074 D01 v03r02 (DTS Meas Guidance) ANSI C63.10-2009 Test Exercise Multiple samples were used Test Supporting Equipment Supporting Device Manufacturer Model / FCC ID S/N Supplied By 100-240 VAC Power Supply JFEC JF006WR-0900066UH 4000161 Applicant APPLICANT: BUILDING 36 TECHNOLOGIES, LLC FCC ID: 2AC3T-H200BRA IC Cert#: 12323A-H200BRA REPORT: B\BUILDING 36\411AUT15\411AUT15TestReport.docx Page 6 of 27 SUMMARY Specification FCC Rules Part IC RSS Result Power Line Conducted Emissions 15.207(a) 210 2.1 Pass Occupied Bandwidth 15.247(a)(2) 210 A8.2(a) Pass Bandedge 15.205(a)(b) 210 2.2 N/A(1) Output Power 15.247(b)(3-4) 210 A8.4(4) Pass Power Spectral Density 15.247(e) 210 A8.2(b) Pass Antenna Conducted Emissions 15.247(d) 210 A8.5 Pass Radiated Emissions 15.205(a)(b) 210 2.2 Pass Antenna Requirements 15.203 NA Pass Notes: 1. The EUT’s band of operation does not have an adjacent restricted band as found in part 15.205 and RSS-Gen 8.10; no testing is required for Adjacent Restricted Bande dge compliance, only radiated emissions falling in restricted bands are required and are reported with the radiated emissions. Table of Contents APPLICANT: BUILDING 36 TECHNOLOGIES, LLC FCC ID: 2AC3T-H200BRA IC Cert#: 12323A-H200BRA REP…
Text truncated - open the document above for the full version.
APPLICANT: BUILDING 36 TECHNOLOGIES, LLC IC: 12323A-H200BRA FCC ID: 2AC3T-H200BRA REPORT: V:\B\BUILDING 36\411DUT15\411DUT15 CO LOCATION TESTREPORT_REV 1.DOCX Page 2 of 8 APPENDIX Radiation Emission Co-Location REPORT Applicant BUILDING 36 TECHNOLOGIES, LLC Address 35 HIGHLAND CIRCLE SUITE 300 NEEDHAM MA 02494 USA FCC ID 2AC3T-H200BRA IC Certification # 12323A-H200BRA Model Number B36-H200-B Product Description 908.4MHz (15.249) + 912–924MHz DSS Both Tx Date Sample Received 4/13/2015 Date Tested 4/13/2014 Tested By Cory Leverett Approved By Sid Sanders Test Results PASS FAIL Report Number Version Number Description Issue Date 411DUT15 Co Location TestReport.docx Rev.1 Initial Issue 4/13/2015 THE ATTACHED REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL WITHOUT THE WRITTEN APPROVAL OF TIMCO ENGINEERING, INC. 849 NW State Road 45 Newberry, FL 32669 USA Ph: 888.472.2424 or 352.472.5500 Fax: 352.472.2030 Email: [email protected] Website: www.timcoengr.com APPLICANT: BUILDING 36 TECHNOLOGIES, LLC IC: 12323A-H200BRA FCC ID: 2AC3T-H200BRA REPORT: V:\B\BUILDING 36\411DUT15\411DUT15 CO LOCATION TESTREPORT_REV 1.DOCX Page 3 of 8 GENERAL REMARKS The attached report shall not be reproduced except in full without the written permission of Timco Engineering Inc. The test results relate only to the items tested. Summary The device under test does: Fulfill the general approval requirements as identified in this test report Not fulfill the general approval requirements as identified in this test report Attestations This equipment has been tested in accordance with the standards identified in this test report. To the best of my knowledge and belief, these tests were performed using the measurement procedures described in this report. All instrumentation and accessories used to test products for compliance to the indicated standards are calibrated regularly in accordance with ISO 17025: 2005 requirements. I attest that the necessary measurements were made, under my supervision, at: Timco Engineering Inc. 849 NW State Road 45 Newberry, FL 32669 Authorized Signatory Name: Cory Leverett Engineering Project Manager Date: 4/13/2015 APPLICANT: BUILDING 36 TECHNOLOGIES, LLC IC: 12323A-H200BRA FCC ID: 2AC3T-H200BRA REPORT: V:\B\BUILDING 36\411DUT15\411DUT15 CO LOCATION TESTREPORT_REV 1.DOCX Page 4 of 8 CO-LOCATION RADIATION INTERFERENCE Rules Part No.: KDB662911 D01 Multiple Transmitter Output v02r01 METHOD OF MEASUREMENT: The procedure used was ANSI standard C63.4-2003 & the FCC/OET KDB662911 D01 Multiple Transmitter Output v02r01 Requirements: Frequency Limits Part 15.209 9 to 490 kHz 2400/F (kHz) μV/m @ 300 meters 490 to 1705 kHz 24000/F (kHz) μV/m @ 30 meters 1705 kHz to 30 MHz 29.54 dBμV/m @ 30 meters 30 – 88 40.0 dBμV/m @ 3 meters 80 – 216 43.5 dBμV/m @ 3 meters 216 – 960 46.0 dBμV/m @ 3 meters Above 960 54.0 dBμV/m @ 3 meters Part 15.247 Fundamental 902 – 928 MHz 127.37 dBμV/m @ 3 meters Fundamental 2.4 – 2.4835 MHz 127.37 dBμV/m @ 3 meters Harmonics 54.0 dBμV/m @ 3 meters Any emissions that fall in the restricted bands (15.205) must be less than or equal to 54 dBμV/m. Spurious emissions not in a restricted band must be 20 dBc. Harmonics were checked through the 10 th harmonic. APPLICANT: BUILDING 36 TECHNOLOGIES, LLC IC: 12323A-H200BRA FCC ID: 2AC3T-H200BRA REPORT: V:\B\BUILDING 36\411DUT15\411DUT15 CO LOCATION TESTREPORT_REV 1.DOCX Page 5 of 8 CO-LOCATION RADIATION INTERFERENCE Test Data: Table of Contents APPLICANT: BUILDING 36 TECHNOLOGIES, LLC IC: 12323A-H200BRA FCC ID: 2AC3T-H200BRA REPORT: V:\B\BUILDING 36\411DUT15\411DUT15 CO LOCATION TESTREPORT_REV 1.DOCX Page 6 of 8 CO-LOCATION RADIATION INTERFERENCE Test Data: APPLICANT: BUILDING 36 TECHNOLOGIES, LLC IC: 12323A-H200BRA FCC ID: 2AC3T-H200BRA REPORT: V:\B\BUILDING 36\411DUT15\411DUT15 CO LOCATION TESTREPORT_REV 1.DOCX Page 7 of 8 CO-LOCATION RADIATION INTERFERENCE Test Data: APPLICANT: BUILDING 36 TECHNOLOGIES, LLC IC: 12323A-H200BRA FCC ID: 2AC3T-H200BRA REPORT: V:\B\BUILDING 36\411DUT15\411DUT15 CO LOCATION TESTREPORT_REV 1.DOCX Page 8 of 8 CO-LOCATION RADIATION INTERFERENCE Test Results:
APPLICANT: BUILDING 36 TECHNOLOGIES, LLC. FCC ID: 2AC3T-H200BRA IC: 12323A-H200BRA TEST SET UP PHOTOS RADIATED EMISSIONS TEST SET UP PHOTOS POWERLINE CONDUCTED EMISSIONS TEST SET UP PHOTO
849 NW State Road 45 · Newberry, Florida · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 912 MHz - 924 MHz | 3.90 mW |

Wireless Thermostat
Equipment Class
DTS - Digital Transmission System
Wireless Water Sensor
Equipment Class
DTS - Digital Transmission System
Temperature sensor
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Thermostat
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Thermostat
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter