Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC STATEMENT 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/ TV technician for help. FCC Radiation Exposure Statement: The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without RF striction.
GUANGZHOU SHANGKE INFORMATION TECHNOLOGY CO., LTD 2014-05-24 To: SIEMIC, INC. 775 Montague Expressway Milpitas , CA 95035 USA Dear Sir/Madam, Re: Project and Product Certification Representative Authorization Letter We , GUANGZHOU SHANGKE INFORMATION TECHNOLOGY CO., LTD. hereby authorize SIEMIC, INC. to act as a Certification Body for certifying for the following project(s): Product Description: Tpad Model name: A80se, A80se Quad, A80 se, P19, G19, X19, P98, G98, X98, P90, G90, X90, P89, G18, X89, P86, X86, P79, G17, X79, P70, A78, A88 FCC ID: 2ACGT-A80SE We affirm that between SIEMIC and GUANGZHOU SHANGKE INFORMATION TECHNOLOGY CO., LTD , any difference in understanding, including test plan, measurement methods, applicable standards and relevant procedures and processes have been resolved prior to commencement of testing activities. Sincerely, Client’s signature Client’s name / title : Tony Liang / Engineering Manager Contact address: A1, E1, C2 Room, 17/F No. 689, GuangDa Bank Bldg., North-Tianhe Road, Tianhe District, GUANGZHOU, China. Contact telephone: 020-38731000-1608 Email: [email protected]
SCS-F19: Confidentiality Request Letter Page 1 of 2 Rev 3.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] FCC Confidentiality Request Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (current) 2.0 3.0 Jan-31-2012 SCS-F19: Confidentiality Request Letter Page 2 of 2 Rev 3.0 GUANGZHOU SHANGKE INFORMATION TECHNOLOGY CO., LTD FCC Confidentiality Request Letter May 23,2014 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Subject: Permanent Confidentiality Request for FCC ID: 2ACGT-A80SE We hereby request confidential treatment of information accompanying this application as outlined below: - Block Diagram - Schematics - Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Client’s signature Client’s name / title : Tony Liang / Engineering Manager Contact address: A1, E1, C2 Room, 17/F No. 689, GuangDa Bank Bldg., North-Tianhe Road, Tianhe District, GUANGZHOU, China. Contact telephone: 020-38731000-1608 Email: [email protected]
GUANGZHOU SHANGKE INFORMATION TECHNOLOGY CO., LTD To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD FCC ID: 2ACGT-A80SE To Whom It May Concern: This letter is to ascertain that GUANGZHOU SHANGKE INFORMATION TECHNOLOGY CO., LTD.(Product name: Tpad Model name: A80se, A80se Quad, A80 se, P19, G19, X19, P98, G98, X98, P90, G90, X90, P89, G18, X89, P86, X86, P79, G17, X79, P70, A78, A88)has been the units used for conducting FCC compliance testing, the DoC part will be tested by FCC recognized test lab. If you have any question or concerns, pls. contact us. Sincerely, Client’s signature Client’s name / title : Tony Liang / Engineering Manager Contact address: A1, E1, C2 Room, 17/F No. 689, GuangDa Bank Bldg., North-Tianhe Road, Tianhe District, GUANGZHOU, China. Contact telephone: 020-38731000-1608 Email: [email protected]
GUANGZHOU SHANGKE INFORMATION TECHNOLOGY CO., LTD Statement FCC ID: 2ACGT-A80SE Model number: A80se, A80se Quad, A80 se, P19, G19, X19, P98, G98, X98, P90, G90, X90, P89, G18, X89, P86, X86, P79, G17, X79, P70, A78, A88 We hereby state that these models are identical in interior structure, electrical circuits and components, and just model names are different for the marketing requirement. Your assistance on this matter is highly appreciated. Sincerely, Client’s signature Client’s name / title : Tony Liang / Engineering Manager Contact address: A1, E1, C2 Room, 17/F No. 689, GuangDa Bank Bldg., North-Tianhe Road, Tianhe District, GUANGZHOU, China. Contact telephone: 020-38731000-1608 Email: [email protected]
External Photos
Label and label location
Internal Photos Antenna
FCC ID : 2ACGT-A80SE Portable device According to §15.247(e)(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to KDB 447498 D01 General RF Exposure Guidance v05, section 4.3.1 The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, 16 where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation 17 The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. The test was performed with 802.11b Frequency (MHz) Peak Output Power (dBm) Peak Output Power (mW) Calculation Value Threshold Value 2412 9.11 8.15 2.53 3.0 2437 8.76 7.52 2.35 3.0 2462 8.08 6.43 2.02 3.0 The test was performed with 802.11g Frequency (MHz) Peak Output Power (dBm) Peak Output Power (mW) Calculation Value Threshold Value 2412 7.94 6.22 1.93 3.0 2437 7.81 6.04 1.89 3.0 2462 7.47 5.58 1.75 3.0 The test was performed with 802.11n (20MHz) Frequency (MHz) Peak Output Power (dBm) Peak Output Power (mW) Calculation Value Threshold Value 2412 7.73 5.93 1.84 3.0 2437 7.19 5.24 1.64 3.0 2462 6.71 4.69 1.47 3.0 The test was performed with 802.11n (40MHz) Frequency (MHz) Peak Output Power (dBm) Peak Output Power (mW) Calculation Value Threshold Value 2422 7.48 5.60 1.74 3.0 2437 7.08 5.11 1.60 3.0 2452 6.11 4.08 1.31 3.0 Threshold at which no SAR required is ≤ 3.0 for 1-g SAR, Separation distance is 5mm. Conclusion: No SAR is required. SIMULTANEOUS TRANSMISSION EVALUATION N/A
Test Photos
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.42 GHz - 2.45 GHz | 5.60 mW |

Digital Calendar
Equipment Class
DTS - Digital Transmission System
Tablet PC
Equipment Class
DTS - Digital Transmission System
MINI PC
Equipment Class
NII - Unlicensed National Information Infrastructure TX