FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. GUANGZHOU SHANGKE INFORMATION TECHNOLOGY CO., LTD/
  3. 2ACGT-TLM001

2ACGT-TLM001MINI PC

GUANGZHOU SHANGKE INFORMATION TECHNOLOGY CO., LTD
MINI PC - FCC ID 2ACGT-TLM001 - GUANGZHOU SHANGKE INFORMATION TECHNOLOGY CO., LTD
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Jul 12, 2023
Application Purpose
Original Equipment
Date of Application
Jul 12, 2023
Equipment Note
MINI PC
Frequency Range
5745.00000000 - 5825.00000000
Company
GUANGZHOU SHANGKE INFORMATION TECHNOLOGY CO., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗
↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Covered Equipment Identification Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows: We, applicant Company Name: Guangzhou Shangke Information Technology Co., LTD. Address: Room 1205-1212, R&F To-Win Building, No.30 Huaxia Road, Tianhe District, Guangzhou, Guangdong Province, China Phone: +86-20-38731000 certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. FCC ID: 2ACGT-TLM001 If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-07-12 Name / Title: Tony Liang / Engineering Manager Company: Guangzhou Shangke Information Technology Co., LTD. Address: Room 1205-1212, R&F To-Win Building, No.30 Huaxia Road, Tianhe District, Guangzhou, Guangdong Province, China Phone: +86-20-38731000 Fax: +86-20-38731000-1608 E-Mail: [email protected]

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2ACGT-TLM001 TLM001, TLM002, TLM003, TLM004, TLM005, TLM006, TLM007, TLM008, TLM009, TLM010, TLM011, TLM012, TLM013, TLM014, TLM015, TLM016, TLM017, TLM018, TLM019, TLM020, TLM021, TLM022, TLM023, TLM024, TLM025, TLM026, TLM027, TLM028, TLM029, TLM030, TLM031, TLM032, TLITXK01, TLITXK02, TLITXN01, TLITXN02, TLITXQ01, TLITXQ02, TLITXT01, TLITXT02 We, applicant Company Name: Guangzhou Shangke Information Technology Co., LTD. Address: Room 1205-1212, R&F To-Win Building, No.30 Huaxia Road, Tianhe District, Guangzhou, Guangdong Province, China Phone: +86-20-38731000 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-07-12 Name / Title: Tony Liang / Engineering Manager Company: Guangzhou Shangke Information Technology Co., LTD. Address: Room 1205-1212, R&F To-Win Building, No.30 Huaxia Road, Tianhe District, Guangzhou, Guangdong Province, China Phone:+86-20-38731000 Fax: +86-20-38731000-1608 E-Mail: [email protected]

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2ACGT-TLM001 TLM001, TLM002, TLM003, TLM004, TLM005, TLM006, TLM007, TLM008, TLM009, TLM010, TLM011, TLM012, TLM013, TLM014, TLM015, TLM016, TLM017, TLM018, TLM019, TLM020, TLM021, TLM022, TLM023, TLM024, TLM025, TLM026, TLM027, TLM028, TLM029, TLM030, TLM031, TLM032, TLITXK01, TLITXK02, TLITXN01, TLITXN02, TLITXQ01, TLITXQ02, TLITXT01, TLITXT02 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Signature Date:2023-07-12 Name / Title: Tony Liang / Engineering Manager Company: Guangzhou Shangke Information Technology Co., LTD. Address: Room 1205-1212, R&F To-Win Building, No.30 Huaxia Road, Tianhe District, Guangzhou, Guangdong Province, China Phone: +86-20-38731000 Fax: +86-20-38731000-1608 E-Mail: [email protected]

Cover Letter(s)

Guangzhou Shangke Information Technology Co., LTD. Room 1205-1212, R&F To-Win Building, No.30 Huaxia Road, Tianhe District, Guangzhou, Guangdong Province, China Date: July 12, 2023 FCC ID: 2ACGT-TLM001 Model Number: TLM001, TLM002, TLM003, TLM004, TLM005, TLM006, TLM007, TLM008, TLM009, TLM010, TLM011, TLM012, TLM013, TLM014, TLM015, TLM016, TLM017, TLM018, TLM019, TLM020, TLM021, TLM022, TLM023, TLM024, TLM025, TLM026, TLM027, TLM028, TLM029, TLM030, TLM031, TLM032, TLITXK01, TLITXK02, TLITXN01, TLITXN02, TLITXQ01, TLITXQ02, TLITXT01, TLITXT02 To: Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21048 To Whom It May Concern, We, Guangzhou Shangke Information Technology Co., LTD. hereby declare that our product (MINI PC) Model Number: TLM001, TLM002, TLM003, TLM004, TLM005, TLM006, TLM007, TLM008, TLM009, TLM010, TLM011, TLM012, TLM013, TLM014, TLM015, TLM016, TLM017, TLM018, TLM019, TLM020, TLM021, TLM022, TLM023, TLM024, TLM025, TLM026, TLM027, TLM028, TLM029, TLM030, TLM031, TLM032, TLITXK01, TLITXK02, TLITXN01, TLITXN02, TLITXQ01, TLITXQ02, TLITXT01, TLITXT02 board, Schematic, Hardware version, Software version, structure and internal photos are same, they will have two kinds of plastic case and named differently due to marketing purposes. Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, (Signed) Name / Title: Tony Liang / Engineering Manager Company: Guangzhou Shangke Information Technology Co., LTD. Address: Room 1205-1212, R&F To-Win Building, No.30 Huaxia Road, Tianhe District, Guangzhou, Guangdong Province, China Phone: +86-20-38731000 Fax: +86-20-38731000-1608 E-Mail: [email protected]

External Photos

FCC ID: 2ACGT-TLM001 Fig. 1 Fig. 2 FCC ID: 2ACGT-TLM001 Fig. 3 Fig. 4 FCC ID: 2ACGT-TLM001 Fig. 5 Fig. 6 FCC ID: 2ACGT-TLM001 Fig. 7 Fig. 8 FCC ID: 2ACGT-TLM001 Fig. 9

ID Label/Location Info

_____________________________________________________________________________________________________ LABEL AND LOCATION _____________________________________________________________________________________________________ (Size: L7.0cm x 3.5cm) Label Location Plastic case 1 Plastic case 2

Internal Photos

FCC ID: 2ACGT-TLM001 Fig. 1 Fig. 2 FCC ID: 2ACGT-TLM001 Fig. 3 Fig. 4 BT&WLAN Antenna 1 WLAN Antenna 2 FCC ID: 2ACGT-TLM001 Fig. 5 Fig. 6 FCC ID: 2ACGT-TLM001 Fig. 7 Fig. 8 FCC ID: 2ACGT-TLM001 Fig. 9 Fig. 10 FCC ID: 2ACGT-TLM001 Fig. 11 Fig. 12 FCC ID: 2ACGT-TLM001 Fig. 13 Fig. 14 FCC ID: 2ACGT-TLM001 Fig. 15 Fig. 16

RF Exposure Info

Shenzhen Global Test Service Co.,Ltd. No.7-101 and 8A-104, Building 7 and 8, DCC Cultural and Creative Garden, No.98, Pingxin North Road, Shangmugu Community, Pinghu Street, Longgang District, Shenzhen, Guangdong RF Exposure evaluation Report Reference No...................... : FCC ID. ............................................ : GTS20230508024-1-47 2ACGT-TLM001 Compiled by ( position+printed name+signature) . : File administrators Peter Xiao Supervised by ( position+printed name+signature) . : Test Engineer Jenny Zeng Approved by ( position+printed name+signature) . : Manager Jason Hu Date of issue .................................... : Jun.10, 2023 Representative Laboratory Name . : Shenzhen Global Test Service Co.,Ltd. Address ............................................ : No.7-101 and 8A-104, Building 7 and 8, DCC Cultural and Creative Garden, No.98, Pingxin North Road, Shangmugu Community, Pinghu Street, Longgang District, Shenzhen, Guangdong Applicant’s name ............................ : Guangzhou Shangke Information Technology Co., LTD. Address ............................................ : Room 1205-1212, R&F To-Win Building, No.30 Huaxia Road, Tianhe District, Guangzhou, Guangdong Province, China Test specification ........................... : Standard ........................................... : 47CFR §1.1310 Basis and purpose 47CFR §2.1091 Radiofrequency radiation exposure evaluation: mobile devices KDB447498 D01 General RF Exposure Guidance v06 TRF Originator .................................. : Shenzhen Global Test Service Co.,Ltd. Master TRF ...................................... : Dated 2014-12 Shenzhen Global Test Service Co.,Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen Global Test Service Co.,Ltd. is acknowledged as copyright owner and source of the material. Shenzhen Global Test Service Co.,Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : MINI PC Trade Mark ....................................... : TECLAST Manufacturer .................................... : Guangzhou Shangke Information Technology Co., LTD. Model/Type reference ...................... : TLM001 Listed Models .................................. : TLM002, TLM003, TLM004, TLM005, TLM006, TLM007, TLM008, TLM009, TLM010, TLM011, TLM012, TLM013, TLM014, TLM015, TLM016, TLM017, TLM018, TLM019, TLM020, TLM021, TLM022, TLM023, TLM024, TLM025, TLM026, TLM027, TLM028, TLM029, TLM030, TLM031, TLM032, TLITXK01, TLITXK02, TLITXN01, TLITXN02, TLITXQ01, TLITXQ02, TLITXT01, TLITXT02 Hardware Version ............................ : N/A Software Version .............................. : N/A Rating ............................................... : DC 12.0V/4.0A by Adapter Result ............................................... : PASS Report No.: GTS20230508024-1-47 Page 2 of 19 T E S T R E P O R T Test Report No. : GTS20230508024-1-47 Jun.10, 2023 ______________________________________________________________________________________________ Date of issue Equipment under Test : MINI PC Model /Type : TLM001 Listed model : TLM002, TLM003, TLM004, TLM005, TLM006, TLM007, TLM008, TLM009, TLM010, TLM011, TLM012, TLM013, TLM014, TLM015, TLM016, TLM017, TLM018, TLM019, TLM020, TLM021, TLM022, TLM023, TLM024, TLM025, TLM026, TLM027, TLM028, TLM029, TLM030, TLM031, TLM032, TLITXK01, TLITXK02, TLITXN01, TLITXN02, TLITXQ01, TLITXQ02, TLITXT01, TLITXT02 Applicant : Guangzhou Shangke Information Technology Co., LTD. Address : Room 1205-1212, R&F To-Win Building, No.30 Huaxia Road, Tianhe District, Guangzhou, Guangdong Province, China Manufacturer : Guangzhou Shangke Information Technology Co., LTD. Address : Room 1205-1212, R&F To-Win Building, No.30 Huaxia Road, Tianhe District, Guangzhou, Guangdong Province, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: GTS20230508024-1-47 Page 3 of 19 Contents 1. SUMMARY ............................................................................................................................................................. 4 1.1 PRODUCT DESCRIPTION ..................................................................................................................................................... 4 2. TEST ENVIRONMENT .............................................................................................................................................. 5 2.1 ADDRESS OF THE TEST LABORATORY ..................................................................................................................................... 5 2.2 TEST FACILITY .................................................................................................................................................................. 5 2.3 ENVIRONMENTAL CONDITIONS ............................................................................................................................................ 5 2.4 STATEMENT OF THE MEASUREMENT UNCERTAINTY .................................................................................................................. 5 3. METHOD OF MEASUREMENT ................................................................................................................................. 6 3.1 APPLICABLE STANDARD ...................................................................................................................................................... 6 3.2 REQUIREMENT ................................................................................................................................................................. 6 3.3 LIMIT ....................................…

Text truncated - open the document above for the full version.

Test Report

Customer: Teclast Project: MINI PC Product: WIFI Antenna Report date: 2023.06.06 Prepared by : Chen shi lian Checked by : Eason Huang Approved by : Shenzhen Yishengbang Technology Co., Ltd Antenna Test Report Shenzhen Yishengbang Technology Co., Ltd 1 Purpose This report is to measure the performance of SLK for Master Antenna on Teclast. All measure data are showed below. Content 1. Product Overview 2. Test Result 2.1 WIFI Antenna VSWR/S11 2.2 Antenna parameters 2.3 WIFI Antenna Gain/Efficiency/3D DATA 2.4 Product drawing 3. Conclusions Shenzhen Yishengbang Technology Co., Ltd 2 1. Product Overview Shenzhen Yishengbang Technology Co., Ltd 3 2. 1 WIFI Antenna VSWR/S11 (MAIN) 2. Test Result Shenzhen Yishengbang Technology Co., Ltd 4 2. 1 WIFI Antenna VSWR/S11 (AUX) 2. Test Result Shenzhen Yishengbang Technology Co., Ltd 5 2. Test Result 2.2 Antenna parameters Shenzhen Yishengbang Technology Co., Ltd 6 Frequenc y ( MHz) 2400.02450.02500.05150.05250.05750.05850.0 Efficiency ( dBi) -7.98-7.91-7.88-5.94-5.92 -4.02-4.39 Gain( dBi) 2.55 1.26 1.22 2.7 32.0 2 2.78 2. 11 Efficien cy (%) 15.9216.1816.2825.4525.5739.6536.42 2. Test Result 2.3 WIFI Antenna Gain /Efficiency/3D DATA MAIN Shenzhen Yishengbang Technology Co., Ltd 7 Frequenc y ( MHz) 2400.02450.02500.05150.05250.05750.05850.0 Efficiency ( dBi) -7.94-7.82-7.81-5.80-5.87 -6.68 -6.17 Gain( dBi) -0.4 5-0. 15 2.5 32.78 0.5 7 1. 69 Efficien cy (%) 16.0516.5216.5626.3025.90 21.4824.13 2. Test Result 2.3 WIFI Antenna Gain /Efficiency/3D DATA AUX Shenzhen Yishengbang Technology Co., Ltd 7 2.55 2. Test Result 2.4 Product drawing Shenzhen Yishengbang Technology Co., Ltd 7 3. Conclusions Shenzhen Yishengbang Technology Co., Ltd 8

Test Report

FCCID: 2ACGT-TLM001 1 Case No. : GTS20230508024-1-46 Ambient Condition: 23 °C, 48 %RH, Atmos100.1Kpa, Test Date: 2023.6.5 Test Engineer: Jenny zeng Appendix D.1: Emission Bandwidth Test Result Test Mode Antenna Frequency[MHz] 26db EBW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11A Ant1 5180 22.240 5169.360 5191.600 --- --- 5200 22.600 5188.640 5211.240 --- --- 5240 22.920 5228.520 5251.440 --- --- 11N20SISO Ant1 5180 23.560 5168.960 5192.520 --- --- 5200 22.640 5188.760 5211.400 --- --- 5240 24.240 5227.120 5251.360 --- --- 11N40SISO Ant1 5190 43.280 5168.640 5211.920 --- --- 5230 44.240 5208.320 5252.560 --- --- 11AC20SISO Ant1 5180 23.440 5168.640 5192.080 --- --- 5200 23.080 5188.560 5211.640 --- --- 5240 23.840 5228.320 5252.160 --- --- 11AC40SISO Ant1 5190 43.520 5168.640 5212.160 --- --- 5230 44.480 5207.440 5251.920 --- --- 11AC80SISO Ant1 5210 83.840 5168.880 5252.720 --- --- FCCID: 2ACGT-TLM001 2 Test Graphs 11A_Ant1_5180 11A_Ant1_5200 FCCID: 2ACGT-TLM001 3 11A_Ant1_5240 11N20SISO_Ant1_5180 FCCID: 2ACGT-TLM001 4 11N20SISO_Ant1_5200 11N20SISO_Ant1_5240 11N40SISO_Ant1_5190 FCCID: 2ACGT-TLM001 5 11N40SISO_Ant1_5230 11AC20SISO_Ant1_5180 FCCID: 2ACGT-TLM001 6 11AC20SISO_Ant1_5200 11AC20SISO_Ant1_5240 11AC40SISO_Ant1_5190 FCCID: 2ACGT-TLM001 7 11AC40SISO_Ant1_5230 11AC80SISO_Ant1_5210 FCCID: 2ACGT-TLM001 8 Appendix D.2: Occupied channel bandwidth Test Result Test Mode Antenna Frequency[MHz] OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11A Ant1 5180 16.869 5171.635 5188.504 --- --- 5200 16.882 5191.611 5208.493 --- --- 5240 16.958 5231.499 5248.457 --- --- 11N20SISO Ant1 5180 18.044 5171.054 5189.098 --- --- 5200 18.045 5191.025 5209.070 --- --- 5240 18.069 5230.992 5249.061 --- --- 11N40SISO Ant1 5190 36.241 5171.948 5208.189 --- --- 5230 36.219 5211.861 5248.080 --- --- 11AC20SISO Ant1 5180 18.033 5171.033 5189.066 --- --- 5200 18.105 5190.971 5209.076 --- --- 5240 18.067 5230.972 5249.039 --- --- 11AC40SISO Ant1 5190 36.261 5171.956 5208.217 --- --- 5230 36.269 5211.846 5248.115 --- --- 11AC80SISO Ant1 5210 74.791 5172.624 5247.415 --- --- FCCID: 2ACGT-TLM001 9 Test Graphs 11A_Ant1_5180 11A_Ant1_5200 FCCID: 2ACGT-TLM001 10 11A_Ant1_5240 11N20SISO_Ant1_5180 FCCID: 2ACGT-TLM001 11 11N20SISO_Ant1_5200 11N20SISO_Ant1_5240 11N40SISO_Ant1_5190 FCCID: 2ACGT-TLM001 12 11N40SISO_Ant1_5230 11AC20SISO_Ant1_5180 FCCID: 2ACGT-TLM001 13 11AC20SISO_Ant1_5200 11AC20SISO_Ant1_5240 11AC40SISO_Ant1_5190 FCCID: 2ACGT-TLM001 14 11AC40SISO_Ant1_5230 11AC80SISO_Ant1_5210 FCCID: 2ACGT-TLM001 15 Appendix D.3: Duty Cycle Test Result Test Mode Antenna Frequency[MHz] Transmission Duration [ms] Transmission Period [ms] Duty Cycle [%] 11A Ant1 5180 2.05 2.07 99.03 5200 2.05 2.08 98.56 5240 2.05 2.08 98.56 11N20SISO Ant1 5180 1.90 1.93 98.45 5200 1.91 1.94 98.45 5240 1.91 1.94 98.45 11N40SISO Ant1 5190 0.94 0.97 96.91 5230 0.94 0.97 96.91 11AC20SISO Ant1 5180 1.91 1.94 98.45 5200 1.91 1.94 98.45 5240 1.92 1.95 98.46 11AC40SISO Ant1 5190 0.94 0.97 96.91 5230 0.94 0.97 96.91 11AC80SISO Ant1 5210 0.46 0.49 93.88 FCCID: 2ACGT-TLM001 16 Test Graphs 11A_Ant1_5180 11A_Ant1_5200 FCCID: 2ACGT-TLM001 17 11A_Ant1_5240 11N20SISO_Ant1_5180 FCCID: 2ACGT-TLM001 18 11N20SISO_Ant1_5200 11N20SISO_Ant1_5240 11N40SISO_Ant1_5190 FCCID: 2ACGT-TLM001 19 11N40SISO_Ant1_5230 11AC20SISO_Ant1_5180 FCCID: 2ACGT-TLM001 20 11AC20SISO_Ant1_5200 11AC20SISO_Ant1_5240 11AC40SISO_Ant1_5190 FCCID: 2ACGT-TLM001 21 11AC40SISO_Ant1_5230 11AC80SISO_Ant1_5210 FCCID: 2ACGT-TLM001 22 Appendix D.4: Maximum conducted output power Test Result Channel Power Test Mode Antenna Frequency[M Hz] Channel Powert [dBm] Duty Cycle [%] DC Factor [dBm] Result [dBm] Limit [dBm] Verdict 11A Ant1 5180 10.63 99.03 0.04 10.67 ≤23.98 PASS 5200 10.64 98.56 0.06 10.70 ≤23.98 PASS 5240 10.77 98.56 0.06 10.83 ≤23.98 PASS 11N20SISO Ant1 5180 11.22 98.45 0.07 11.29 ≤23.98 PASS 5200 11.28 98.45 0.07 11.35 ≤23.98 PASS 5240 11.41 98.45 0.07 11.48 ≤23.98 PASS 11N40SISO Ant1 5190 11.26 96.91 0.14 11.40 ≤23.98 PASS 5230 11.26 96.91 0.14 11.40 ≤23.98 PASS 11AC20SIS O Ant1 5180 11.22 98.45 0.07 11.29 ≤23.98 PASS 5200 11.24 98.45 0.07 11.31 ≤23.98 PASS 5240 11.42 98.46 0.07 11.49 ≤23.98 PASS 11AC40SIS O Ant1 5190 11.24 96.91 0.14 11.38 ≤23.98 PASS 5230 11.31 96.91 0.14 11.45 ≤23.98 PASS 11AC80SIS O Ant1 5210 10.94 93.88 0.27 11.21 ≤23.98 PASS Note:The Duty Cycle Factor is compensated in the graph. FCCID: 2ACGT-TLM001 23 Appendix D.5: Maximum power spectral density Test Result Test Mode Antenna Frequency[MHz] Result [dBm/MHz] Limit[dBm/MHz] Verdict 11A Ant1 5180 -0.33 ≤11.00 PASS 5200 -0.2 ≤11.00 PASS 5240 0 ≤11.00 PASS 11N20SISO Ant1 5180 0.34 ≤11.00 PASS 5200 0.3 ≤11.00 PASS 5240 0.65 ≤11.00 PASS 11N40SISO Ant1 5190 -2.79 ≤11.00 PASS 5230 -2.64 ≤11.00 PASS 11AC20SISO Ant1 5180 0.29 ≤11.00 PASS 5200 0.47 ≤11.00 PASS 5240 0.61 ≤11.00 PASS 11AC40SISO Ant1 5190 -2.75 ≤11.00 PASS 5230 -2.5 ≤11.00 PASS 11AC80SISO Ant1 5210 -5.48 ≤11.00 PASS Note:1.The Result and Limit Unit is dBm/500 kHz in the band 5.7255.85 GHz. 2.The Duty Cycle Factor and RBW Factor is compensated in the graph. FCCID: 2ACGT-TLM001 24 Test Graphs 11A_Ant1_5180 11A_Ant1_5200 FCCID: 2ACGT-TLM001 25 11A_Ant1_5240 11N20SISO_Ant1_5180 FCCID: 2ACGT-TLM001 26 11N20SISO_Ant1_5200 11N20SISO_Ant1_5240 11N40SISO_Ant1_5190 FCCID: 2ACGT-TLM001 27 11N40SISO_Ant1_5230 11AC20SISO_Ant1_5180 FCCID: 2ACGT-TLM001 28 11AC20SISO_Ant1_5200 11AC20SISO_Ant1_5240 11AC40SISO_Ant1_5190 FCCID: 2ACGT-TLM001 29 11AC40SISO_Ant1_5230 11AC80SISO_Ant1_5210 FCCID: 2ACGT-TLM001 30 Appendix D.6: Band edge measurements Test Result B1 Test Mode Antenna ChName Frequency[MHz] Result[dBm] Limit[dBm] Verdict 11A Ant1 Low 5180 -37.73 ≤-27 PASS High 5240 -38.46 ≤-27 PASS 11N20SISO Ant1 Low 5180 -37.5 ≤-27 PASS High 5240 -38.13 ≤-27 PASS 11N40SISO Ant1 Low 5190 -33.41 ≤-27 PASS High 5230 -38.19 ≤-27 PASS 11AC20SISO Ant1 Low 5180 -34.31 ≤-27 PASS High 5240 -37.88 ≤-27 PASS 11AC40SISO Ant1 Low 5190 -34.98 ≤-27 PASS High 5230 -38.24 ≤-27 PASS 11AC80SISO Ant1 Low 5210 -33.44 ≤-…

Text truncated - open the document above for the full version.

Test Report

FCCID: 2ACGT-TLM001 1 Case No. : GTS20230508024-1-46 Ambient Condition: 24 °C, 49 %RH, Atmos100.1Kpa, Test Date: 2023.6.6 Test Engineer: Jenny zeng Appendix D.1: Emission Bandwidth Test Result Test Mode Antenna Frequency[MHz] 26db EBW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11A Ant2 5180 23.600 5168.680 5192.280 --- --- 5200 24.240 5187.960 5212.200 --- --- 5240 23.480 5228.120 5251.600 --- --- 11N20SISO Ant2 5180 23.720 5168.400 5192.120 --- --- 5200 24.040 5188.000 5212.040 --- --- 5240 24.600 5227.440 5252.040 --- --- 11N40SISO Ant2 5190 45.920 5167.680 5213.600 --- --- 5230 47.200 5206.320 5253.520 --- --- 11AC20SISO Ant2 5180 24.200 5167.880 5192.080 --- --- 5200 25.600 5187.480 5213.080 --- --- 5240 25.000 5226.840 5251.840 --- --- 11AC40SISO Ant2 5190 46.480 5167.040 5213.520 --- --- 5230 46.640 5206.400 5253.040 --- --- 11AC80SISO Ant2 5210 84.800 5167.760 5252.560 --- --- FCCID: 2ACGT-TLM001 2 Test Graphs 11A_Ant2_5180 11A_Ant2_5200 FCCID: 2ACGT-TLM001 3 11A_Ant2_5240 11N20SISO_Ant2_5180 FCCID: 2ACGT-TLM001 4 11N20SISO_Ant2_5200 11N20SISO_Ant2_5240 11N40SISO_Ant2_5190 FCCID: 2ACGT-TLM001 5 11N40SISO_Ant2_5230 11AC20SISO_Ant2_5180 FCCID: 2ACGT-TLM001 6 11AC20SISO_Ant2_5200 11AC20SISO_Ant2_5240 11AC40SISO_Ant2_5190 FCCID: 2ACGT-TLM001 7 11AC40SISO_Ant2_5230 11AC80SISO_Ant2_5210 FCCID: 2ACGT-TLM001 8 Appendix D.2: Occupied channel bandwidth Test Result Test Mode Antenna Frequency[MHz] OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11A Ant2 5180 17.153 5171.493 5188.646 --- --- 5200 17.156 5191.442 5208.598 --- --- 5240 17.052 5231.436 5248.488 --- --- 11N20SISO Ant2 5180 18.227 5170.941 5189.168 --- --- 5200 18.174 5190.960 5209.134 --- --- 5240 18.213 5230.871 5249.084 --- --- 11N40SISO Ant2 5190 36.429 5171.815 5208.244 --- --- 5230 36.474 5211.698 5248.172 --- --- 11AC20SISO Ant2 5180 18.168 5170.954 5189.122 --- --- 5200 18.194 5190.933 5209.127 --- --- 5240 18.215 5230.843 5249.058 --- --- 11AC40SISO Ant2 5190 36.434 5171.890 5208.324 --- --- 5230 36.433 5211.723 5248.156 --- --- 11AC80SISO Ant2 5210 74.954 5172.534 5247.488 --- --- FCCID: 2ACGT-TLM001 9 Test Graphs 11A_Ant2_5180 11A_Ant2_5200 FCCID: 2ACGT-TLM001 10 11A_Ant2_5240 11N20SISO_Ant2_5180 FCCID: 2ACGT-TLM001 11 11N20SISO_Ant2_5200 11N20SISO_Ant2_5240 11N40SISO_Ant2_5190 FCCID: 2ACGT-TLM001 12 11N40SISO_Ant2_5230 11AC20SISO_Ant2_5180 FCCID: 2ACGT-TLM001 13 11AC20SISO_Ant2_5200 11AC20SISO_Ant2_5240 11AC40SISO_Ant2_5190 FCCID: 2ACGT-TLM001 14 11AC40SISO_Ant2_5230 11AC80SISO_Ant2_5210 FCCID: 2ACGT-TLM001 15 Appendix D.3: Duty Cycle Test Result Test Mode Antenna Frequency[MHz] Transmission Duration [ms] Transmission Period [ms] Duty Cycle [%] 11A Ant2 5180 2.05 2.16 94.91 5200 2.05 2.16 94.91 5240 2.05 2.16 94.91 11N20SISO Ant2 5180 1.91 2.00 95.50 5200 1.91 2.00 95.50 5240 1.91 2.00 95.50 11N40SISO Ant2 5190 0.93 1.11 83.78 5230 0.94 1.11 84.68 11AC20SISO Ant2 5180 1.91 2.00 95.50 5200 1.92 2.00 96.00 5240 1.92 2.01 95.52 11AC40SISO Ant2 5190 0.94 1.12 83.93 5230 0.95 1.12 84.82 11AC80SISO Ant2 5210 0.46 0.55 83.64 FCCID: 2ACGT-TLM001 16 Test Graphs 11A_Ant2_5180 11A_Ant2_5200 FCCID: 2ACGT-TLM001 17 11A_Ant2_5240 11N20SISO_Ant2_5180 FCCID: 2ACGT-TLM001 18 11N20SISO_Ant2_5200 11N20SISO_Ant2_5240 11N40SISO_Ant2_5190 FCCID: 2ACGT-TLM001 19 11N40SISO_Ant2_5230 11AC20SISO_Ant2_5180 FCCID: 2ACGT-TLM001 20 11AC20SISO_Ant2_5200 11AC20SISO_Ant2_5240 11AC40SISO_Ant2_5190 FCCID: 2ACGT-TLM001 21 11AC40SISO_Ant2_5230 11AC80SISO_Ant2_5210 FCCID: 2ACGT-TLM001 22 Appendix D.4: Maximum conducted output power Test Result Channel Power Test Mode Antenna Frequency[M Hz] Channel Powert [dBm] Duty Cycle [%] DC Factor [dBm] Result [dBm] Limit [dBm] Verdict 11A Ant2 5180 12.29 94.91 0.23 12.52 ≤23.98 PASS 5200 12.67 94.91 0.23 12.90 ≤23.98 PASS 5240 12.82 94.91 0.23 13.05 ≤23.98 PASS 11N20SISO Ant2 5180 12.37 95.50 0.20 12.57 ≤23.98 PASS 5200 12.62 95.50 0.20 12.82 ≤23.98 PASS 5240 12.74 95.50 0.20 12.94 ≤23.98 PASS 11N40SISO Ant2 5190 11.94 83.78 0.77 12.71 ≤23.98 PASS 5230 12.35 84.68 0.72 13.07 ≤23.98 PASS 11AC20SISO Ant2 5180 12.34 95.50 0.20 12.54 ≤23.98 PASS 5200 12.59 96.00 0.18 12.77 ≤23.98 PASS 5240 12.72 95.52 0.20 12.92 ≤23.98 PASS 11AC40SISO Ant2 5190 11.91 83.93 0.76 12.67 ≤23.98 PASS 5230 12.46 84.82 0.72 13.18 ≤23.98 PASS 11AC80SISO Ant2 5210 11.77 83.64 0.78 12.55 ≤23.98 PASS Note:The Duty Cycle Factor is compensated in the graph. FCCID: 2ACGT-TLM001 23 Appendix D.5: Maximum power spectral density Test Result Test Mode Antenna Frequency[MHz] Result [dBm/MHz] Limit[dBm/MHz] Verdict 11A Ant2 5180 4.44 ≤11.00 PASS 5200 2.15 ≤11.00 PASS 5240 2.38 ≤11.00 PASS 11N20SISO Ant2 5180 1.49 ≤11.00 PASS 5200 1.72 ≤11.00 PASS 5240 2.06 ≤11.00 PASS 11N40SISO Ant2 5190 -1.11 ≤11.00 PASS 5230 -0.46 ≤11.00 PASS 11AC20SISO Ant2 5180 1.58 ≤11.00 PASS 5200 1.7 ≤11.00 PASS 5240 2.08 ≤11.00 PASS 11AC40SISO Ant2 5190 -0.47 ≤11.00 PASS 5230 -0.47 ≤11.00 PASS 11AC80SISO Ant2 5210 -3.95 ≤11.00 PASS Note:1.The Result and Limit Unit is dBm/500 kHz in the band 5.7255.85 GHz. 2.The Duty Cycle Factor and RBW Factor is compensated in the graph. FCCID: 2ACGT-TLM001 24 Test Graphs 11A_Ant2_5180 11A_Ant2_5200 FCCID: 2ACGT-TLM001 25 11A_Ant2_5240 11N20SISO_Ant2_5180 FCCID: 2ACGT-TLM001 26 11N20SISO_Ant2_5200 11N20SISO_Ant2_5240 11N40SISO_Ant2_5190 FCCID: 2ACGT-TLM001 27 11N40SISO_Ant2_5230 11AC20SISO_Ant2_5180 FCCID: 2ACGT-TLM001 28 11AC20SISO_Ant2_5200 11AC20SISO_Ant2_5240 11AC40SISO_Ant2_5190 FCCID: 2ACGT-TLM001 29 11AC40SISO_Ant2_5230 11AC80SISO_Ant2_5210 FCCID: 2ACGT-TLM001 30 Appendix D.6: Band edge measurements Test Result B1 Test Mode Antenna ChName Frequency[MHz] Result[dBm] Limit[dBm] Verdict 11A Ant2 Low 5180 -35.83 ≤-27 PASS High 5240 -37.44 ≤-27 PASS 11N20SISO Ant2 Low 5180 -36.53 ≤-27 PASS High 5240 -38.3 ≤-27 PASS 11N40SISO Ant2 Low 5190 -30.49 ≤-27 PASS High 5230 -38.14 ≤-27 PASS 11AC20SISO Ant2 Low 5180 -35.07 ≤-27 PASS High 5240 -37.55 ≤-27 PASS 11AC40SISO Ant2 Low 5190 -29.48 ≤-27 PASS High 5230 -38.34 ≤-27 PASS 11AC80SISO Ant2 Low 5210 -29.05 ≤-…

Text truncated - open the document above for the full version.

Test Report

FCCID: 2ACGT-TLM001 1 Case No. : GTS20230508024-1-46 Ambient Condition: 23 °C, 49 %RH, Atmos100.1Kpa, Test Date: 2023.6.6 Test Engineer: Jenny zeng Appendix E.1: Occupied channel bandwidth Test Result Test Mode Antenna Frequency[MHz] OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11A Ant1 5745 17.312 5736.284 5753.596 --- --- 5785 17.960 5775.933 5793.893 --- --- 5825 19.004 5815.308 5834.312 --- --- 11N20SISO Ant1 5745 18.485 5735.668 5754.153 --- --- 5785 18.696 5775.606 5794.302 --- --- 5825 19.487 5815.160 5834.647 --- --- 11N40SISO Ant1 5755 36.740 5736.473 5773.213 --- --- 5795 36.834 5776.537 5813.371 --- --- 11AC20SISO Ant1 5745 18.577 5735.656 5754.233 --- --- 5785 19.063 5775.382 5794.445 --- --- 5825 19.584 5815.087 5834.671 --- --- 11AC40SISO Ant1 5755 36.639 5736.595 5773.234 --- --- 5795 36.829 5776.579 5813.408 --- --- 11AC80SISO Ant1 5775 75.278 5737.145 5812.423 --- --- FCCID: 2ACGT-TLM001 2 Test Graphs 11A_Ant1_5745 11A_Ant1_5785 FCCID: 2ACGT-TLM001 3 11A_Ant1_5825 11N20SISO_Ant1_5745 FCCID: 2ACGT-TLM001 4 11N20SISO_Ant1_5785 11N20SISO_Ant1_5825 11N40SISO_Ant1_5755 FCCID: 2ACGT-TLM001 5 11N40SISO_Ant1_5795 11AC20SISO_Ant1_5745 FCCID: 2ACGT-TLM001 6 11AC20SISO_Ant1_5785 11AC20SISO_Ant1_5825 11AC40SISO_Ant1_5755 FCCID: 2ACGT-TLM001 7 11AC40SISO_Ant1_5795 11AC80SISO_Ant1_5775 FCCID: 2ACGT-TLM001 8 Appendix E.2: Min emission bandwidth Test Result B4 Test Mode Antenna Frequency[MHz] 6db EBW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11A Ant1 5745 14.000 5737.440 5751.440 0.5 PASS 5785 15.080 5777.440 5792.520 0.5 PASS 5825 15.120 5817.440 5832.560 0.5 PASS 11N20SISO Ant1 5745 15.080 5737.400 5752.480 0.5 PASS 5785 15.040 5777.440 5792.480 0.5 PASS 5825 15.120 5817.440 5832.560 0.5 PASS 11N40SISO Ant1 5755 35.040 5737.400 5772.440 0.5 PASS 5795 35.040 5777.480 5812.520 0.5 PASS 11AC20SISO Ant1 5745 16.080 5736.480 5752.560 0.5 PASS 5785 15.400 5777.120 5792.520 0.5 PASS 5825 13.720 5817.560 5831.280 0.5 PASS 11AC40SISO Ant1 5755 35.040 5737.480 5772.520 0.5 PASS 5795 35.040 5777.480 5812.520 0.5 PASS 11AC80SISO Ant1 5775 68.800 5737.400 5806.200 0.5 PASS FCCID: 2ACGT-TLM001 9 Test Graphs B4 11A_Ant1_5745 11A_Ant1_5785 FCCID: 2ACGT-TLM001 10 11A_Ant1_5825 11N20SISO_Ant1_5745 FCCID: 2ACGT-TLM001 11 11N20SISO_Ant1_5785 11N20SISO_Ant1_5825 11N40SISO_Ant1_5755 FCCID: 2ACGT-TLM001 12 11N40SISO_Ant1_5795 11AC20SISO_Ant1_5745 FCCID: 2ACGT-TLM001 13 11AC20SISO_Ant1_5785 11AC20SISO_Ant1_5825 11AC40SISO_Ant1_5755 FCCID: 2ACGT-TLM001 14 11AC40SISO_Ant1_5795 11AC80SISO_Ant1_5775 FCCID: 2ACGT-TLM001 15 Appendix E.3: Duty Cycle Test Result Test Mode Antenna Frequency[MHz] Transmission Duration [ms] Transmission Period [ms] Duty Cycle [%] 11A Ant1 5745 2.05 2.08 98.56 5785 2.05 2.08 98.56 5825 2.04 2.07 98.55 11N20SISO Ant1 5745 1.90 1.93 98.45 5785 1.91 1.94 98.45 5825 1.91 1.94 98.45 11N40SISO Ant1 5755 0.94 0.96 97.92 5795 0.94 0.96 97.92 11AC20SISO Ant1 5745 0.14 1.84 95.50 5785 1.91 1.94 98.45 5825 1.91 1.94 98.45 11AC40SISO Ant1 5755 0.94 0.97 96.91 5795 0.95 0.97 97.94 11AC80SISO Ant1 5775 0.45 0.48 93.75 FCCID: 2ACGT-TLM001 16 Test Graphs 11A_Ant1_5745 11A_Ant1_5785 FCCID: 2ACGT-TLM001 17 11A_Ant1_5825 11N20SISO_Ant1_5745 FCCID: 2ACGT-TLM001 18 11N20SISO_Ant1_5785 11N20SISO_Ant1_5825 11N40SISO_Ant1_5755 FCCID: 2ACGT-TLM001 19 11N40SISO_Ant1_5795 11AC20SISO_Ant1_5745 FCCID: 2ACGT-TLM001 20 11AC20SISO_Ant1_5785 11AC20SISO_Ant1_5825 11AC40SISO_Ant1_5755 FCCID: 2ACGT-TLM001 21 11AC40SISO_Ant1_5795 11AC80SISO_Ant1_5775 FCCID: 2ACGT-TLM001 22 Appendix E.4: Maximum conducted output power Tes…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Tony Liang(Engineering Manager)
[email protected]00862038731000Fax: 00862038731000

Test Firm

Shenzhen Global Test Service Co., Ltd.Simon Hu
[email protected]86-137-286-828-40

Technical Specifications

#Rule PartsFrequency RangePower Output
215E5.75 GHz - 5.83 GHz51.40 mW
Confidentiality
Long Term
Grant Notes
Power listed is maximum average conducted output power. This device supports 20 MHz, 40 MHz and 80 MHz bandwidth modes. The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing. The device supports 2.4GHzWLAN, BT and BLE transmitters. The device supports 5GHzWLAN and BT transmitters. The device is a 802.11 a//ac device in a 2x2 Spatial Multiplexing MIMO configuration as described in this filing.

Other Applications from GUANGZHOU SHANGKE INFORMATION TECHNOLOGY CO., LTD

Digital Calendar - FCC ID 2ACGT-C1 - GUANGZHOU SHANGKE INFORMATION TECHNOLOGY CO., LTD
2ACGT-C1

Digital Calendar

Jul 13, 2026

Equipment Class

DTS - Digital Transmission System
Tablet PC - FCC ID 2ACGT-ODE001 - GUANGZHOU SHANGKE INFORMATION TECHNOLOGY CO., LTD
2ACGT-ODE001

Tablet PC

Apr 08, 2024

Equipment Class

DTS - Digital Transmission System
Tpad - FCC ID 2ACGT-A80SE - GUANGZHOU SHANGKE INFORMATION TECHNOLOGY CO., LTD
2ACGT-A80SE

Tpad

May 27, 2014

Equipment Class