Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
VusionGroup GmbH – Kalsdorfer Straße 12 – 8072 Fernitz-Mellach – Austria FB: FN350927w I HG: Graz I UID: ATU65936017 I WEEE: DE 65879240 Tel: +43 (0) 5 9460-400 I Fax: +43 (0) 5 9460-900 www.vusion.com DocuSign Envelope ID: 22906490-1229-409A-9AD2-AD221B3E597A
1 The inclusion of producers or providers of equipment or services identified on this list should be read to include the subsidiaries and affiliates of such entities. DocuSign Envelope ID: 03B51765-901B-4934-8DFA-04EE7D49911D
DocuSign Envelope ID: 03B51765-901B-4934-8DFA-04EE7D49911D
Coverletter: VusionGroup GmbH wants to get FCC-Certification for the following device: EDG3-0150-A. The unit will get the following FCC-ID: 2ACQM-EDG3-0150-A List of documents: Exhibit Thema File Exhibit 01 Label and placement label_and_placement.pdf Exhibit 02 Applicant Authorization Covered List US Agent for Service of Process EDG3-0150-A - Authorization letter FCC.pdf Covered List - FCC - VusionGroup GmbH.pdf US Agent for Service of Process - VusionGroup.pdf ° Exhibit 03 External Photos photos_external.pdf * Exhibit 04 Block Diagrams RFRTx067A00A_BlockDiagram_v1.2.pdf * Exhibit 05 Schematic Diagrams RFRTx067A00A_Schematics_v1.2.pdf Exhibit 06 Testreport Part 15 antenna information 2024-AT-TC-EEE-1-EX-0-000005-FG- 017_noPhotos.pdf Part 15 Antenna Information.pdf ° Exhibit 07 Test Set-up Photos photos_setup.pdf ° Exhibit 08 User Manual 2024-05-23_VusionGroup-CERT_prod- spec_certification.pdf ° Exhibit 09 Internal Photos photos_internal.pdf Exhibit 11 RF exposure 2024-AT-TC-EEE-1-EX-0-000005-FG- 017_noPhotos.pdf * Exhibit 12 Operational Description Additional Antenna Info Operational Description V-Tag_20240522.pdf AntennaSpecSheet_RFRTx067A00A_v1.0.pdf Exhibit 13 Cover letter Request for confidentiality This file EDG3-0150-A - Long term - short term.pdf For the Exhibits marked with ‘*’ VusionGroup GmbH requested Long-Term Confidentiality and for exhibits marked with ‘°’ VusionGroup GmbH requested Short-Term Confidentiality according to 47 CFR 0.457 and 0.459 of the FCC rules because these are sensitive parts owned by this company and include much of know-how or sensitive data, it will not be provided to the public. The labelling on some photos may be not the actual status. The correct labelling is shown on the label photo in Exhibit 1.
VusionGroup GmbH – Kalsdorfer Straße 12 – 8072 Fernitz-Mellach – Austria FB: FN350927w I HG: Graz I UID: ATU65936017 I WEEE: DE 65879240 Tel: +43 (0) 5 9460-400 I Fax: +43 (0) 5 9460-900 www.vusion.com DocuSign Envelope ID: 22906490-1229-409A-9AD2-AD221B3E597A
www.tuv.at | [email protected] No. Test Report: 2024-AT-TC-EEE-1-EX-0-000005-FG-017 Grundvorlage / Basic Template: FM-TAGMBH-KBS-0100b_Grundvorlage Pr ̧fbericht akkreditiert-EN, Rev. 04 FM-TAGMBH-EE- EMV-0100a Revision: 06 Page 1 of 19 T‹V AUSTRIA GMBH Excerpts may only be reproduced with the permission of T‹V AUSTRIA GMBH. All conformity assessment activities were carried out in accordance with the QM system of T‹V AUSTRIA GMBH. Deutschstrafle 10 1230 Vienna / Austria Tel.: +43 (0)504 54 Mail: [email protected] Web: http://www.tuv.at Test Report of the accredited Testing Laboratory 0274 – T‹V AUSTRIA GMBH – Location Vienna - EMC Electromagnetic Compatibility Order Confirmation Number: 2024-AT-TC-EEE-1-EX-0-000005 About the EMC - test listed below Andreas Malek Examined by / Testing Laboratory T‹V AUSTRIA GMBH Michael Emminger Approved by / Testing Laboratory T‹V AUSTRIA GMBH The results of this test report only refer to the provided equipment. Issued on 07.06.2024 in Vienna / TIC Applicant: VusionGroup GmbH Kalsdorfer Strasse 12 A – 8072 Fernitz-Mellach Test object: Electronic shelf labelling system Product Marketing Name: VUSION 1.5 Model: EDG3-0150-A FCC-ID: 2ACQM-EDG3-0150-A IC-ID: 12154A-EDG30150A Serial number: Prototype Accredited regulation: FCC: 47 CFR Part 15 (eCFR 21.05.2024) RSS-210 Issue 10, December 2019 www.tuv.at | [email protected] No. Test Report: 2024-AT-TC-EEE-1-EX-0-000005-FG-017 Grundvorlage / Basic Template: FM-TAGMBH-KBS-0100b_Grundvorlage Pr ̧fbericht akkreditiert-EN, Rev. 04 FM-TAGMBH-EE- EMV-0100a Revision: 06 Page 2 of 19 T‹V AUSTRIA GMBH Excerpts may only be reproduced with the permission of T‹V AUSTRIA GMBH. All conformity assessment activities were carried out in accordance with the QM system of T‹V AUSTRIA GMBH. Deutschstrafle 10 1230 Vienna / Austria Tel.: +43 (0)504 54 Mail: [email protected] Web: http://www.tuv.at Contents Designation page 1. Applicant 3 2. Description of EUT 4 3. Standards / Final result 5 4. Test results 6-19 List of measurements according to 47 CFR 15 and RSS-210 4.1 Test object data 6 4.2 Number of channels and channel spacing 7 4.3 Duty Cycle for averaging 8 4.4 Field strength at 2400 – 2483,5 MHz 9-11 4.5 Emissions outside 2400 – 2483,5 MHz (15.209) 12-16 4.6 RF Exposure 17-19 Appendix Designation pages 1 Test equipment used 5 2 Photodocumentation 11 www.tuv.at | [email protected] No. Test Report: 2024-AT-TC-EEE-1-EX-0-000005-FG-017 Grundvorlage / Basic Template: FM-TAGMBH-KBS-0100b_Grundvorlage Pr ̧fbericht akkreditiert-EN, Rev. 04 FM-TAGMBH-EE- EMV-0100a Revision: 06 Page 3 of 19 T‹V AUSTRIA GMBH Excerpts may only be reproduced with the permission of T‹V AUSTRIA GMBH. All conformity assessment activities were carried out in accordance with the QM system of T‹V AUSTRIA GMBH. Deutschstrafle 10 1230 Vienna / Austria Tel.: +43 (0)504 54 Mail: [email protected] Web: http://www.tuv.at 1. Applicant Company: VusionGroup GmbH Department: Product & Project Manager Address: A – 8072 Fernitz-Mellach; Kalsdorfer Strasse 12 Contact person: Mrs. Tamara Risek-Gmajnic EUT received on: 21.05.2024 Tests were performed on: 21.05. till 23.05.2024 www.tuv.at | [email protected] No. Test Report: 2024-AT-TC-EEE-1-EX-0-000005-FG-017 Grundvorlage / Basic Template: FM-TAGMBH-KBS-0100b_Grundvorlage Pr ̧fbericht akkreditiert-EN, Rev. 04 FM-TAGMBH-EE- EMV-0100a Revision: 06 Page 4 of 19 T‹V AUSTRIA GMBH Excerpts may only be reproduced with the permission of T‹V AUSTRIA GMBH. All conformity assessment activities were carried out in accordance with the QM system of T‹V AUSTRIA GMBH. Deutschstrafle 10 1230 Vienna / Austria Tel.: +43 (0)504 54 Mail: [email protected] Web: http://www.tuv.at 2. Description of EUT EUT: Electronic shelf labelling system Product Name: VUSION 1.5 Model: EDG3-0150-A Serial Number: Prototypes Manufacturer: VusionGroup GmbH A – 8072 Fernitz-Mellach; Kalsdorfer Strasse 12 Description: VusionGroup GmbH provided the following configuration for the measurements: Prototype with special test-firmware for continuous transmission Operating mode: The measurements were carried out at the following running states: test-firmware running, transmitting continuously Technical data EUT: Rated voltage: 3VDC Rated frequency: DC Mains voltage during the tests: 3VDC internal battery Field strength: 3,09 mV/m average @ 3m distance Frequency range: 2404,053 - 2479,285 MHz Channel separation: 0,35 MHz Climatic conditions in the emc laboratory: Relative humidity: 44% Temperature: 25∞C www.tuv.at | [email protected] No. Test Report: 2024-AT-TC-EEE-1-EX-0-000005-FG-017 Grundvorlage / Basic Template: FM-TAGMBH-KBS-0100b_Grundvorlage Pr ̧fbericht akkreditiert-EN, Rev. 04 FM-TAGMBH-EE- EMV-0100a Revision: 06 Page 5 of 19 T‹V AUSTRIA GMBH Excerpts may only be reproduced with the permission of T‹V AUSTRIA GMBH. All conformity assessment activities were carried out in accordance with the QM system of T‹V AUSTRIA GMBH. Deutschstrafle 10 1230 Vienna / Austria Tel.: +43 (0)504 54 Mail: [email protected] Web: http://www.tuv.at 3. Standards / Final result Name Title Deviation Result Title 47 CFR Part 15 eCFR 21.05.2024 RADIO FREQUENCY DEVICES none OK RSS-210 Issue 10, December 2019 Licence-Exempt Radio Apparatus: Category I Equipment none OK RSS-102 Issue 6, December 2023 Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) none OK Result: Opinions and interpretation of testing laboratory OK: EUT passed NOK: EUT failed www.tuv.at | [email protected] No. Test Report: 2024-AT-TC-EEE-1-EX-0-000005-FG-017 Grundvorlage / Basic Template: FM-TAGMBH-KBS-0100b_Grundvorlage Pr ̧fbericht akkreditiert-EN, Rev. 04 FM-TAGMBH-EE- EMV-0100a Revision: 06 Page 6 of 19 T‹V AUSTRIA GMBH Excerpts may only be reproduced with the permission of T‹V AUSTRIA GMBH. All conformity assessment activities were carried out in accordance with the QM system of T‹V AUSTRIA GMBH. Deutschstrafle 10 1230 Vienna / Austria Tel.: +43 (0)504 54 Mail: [email protected] Web: http://www.tuv.at 4. Test results 4.1 TEST OBJECT DATA General EUT Descr…
Text truncated - open the document above for the full version.
www.tuv.at | [email protected] No. Test Report: 2024-AT-TC-EEE-1-EX-0-000005-FG-017 Grundvorlage / Basic Template: FM-TAGMBH-KBS-0100b_Grundvorlage Pr ̧fbericht akkreditiert-EN, Rev. 04 FM-TAGMBH-EE- EMV-0100a Revision: 06 Page 1 of 19 T‹V AUSTRIA GMBH Excerpts may only be reproduced with the permission of T‹V AUSTRIA GMBH. All conformity assessment activities were carried out in accordance with the QM system of T‹V AUSTRIA GMBH. Deutschstrafle 10 1230 Vienna / Austria Tel.: +43 (0)504 54 Mail: [email protected] Web: http://www.tuv.at Test Report of the accredited Testing Laboratory 0274 – T‹V AUSTRIA GMBH – Location Vienna - EMC Electromagnetic Compatibility Order Confirmation Number: 2024-AT-TC-EEE-1-EX-0-000005 About the EMC - test listed below Andreas Malek Examined by / Testing Laboratory T‹V AUSTRIA GMBH Michael Emminger Approved by / Testing Laboratory T‹V AUSTRIA GMBH The results of this test report only refer to the provided equipment. Issued on 07.06.2024 in Vienna / TIC Applicant: VusionGroup GmbH Kalsdorfer Strasse 12 A – 8072 Fernitz-Mellach Test object: Electronic shelf labelling system Product Marketing Name: VUSION 1.5 Model: EDG3-0150-A FCC-ID: 2ACQM-EDG3-0150-A IC-ID: 12154A-EDG30150A Serial number: Prototype Accredited regulation: FCC: 47 CFR Part 15 (eCFR 21.05.2024) RSS-210 Issue 10, December 2019 www.tuv.at | [email protected] No. Test Report: 2024-AT-TC-EEE-1-EX-0-000005-FG-017 Grundvorlage / Basic Template: FM-TAGMBH-KBS-0100b_Grundvorlage Pr ̧fbericht akkreditiert-EN, Rev. 04 FM-TAGMBH-EE- EMV-0100a Revision: 06 Page 2 of 19 T‹V AUSTRIA GMBH Excerpts may only be reproduced with the permission of T‹V AUSTRIA GMBH. All conformity assessment activities were carried out in accordance with the QM system of T‹V AUSTRIA GMBH. Deutschstrafle 10 1230 Vienna / Austria Tel.: +43 (0)504 54 Mail: [email protected] Web: http://www.tuv.at Contents Designation page 1. Applicant 3 2. Description of EUT 4 3. Standards / Final result 5 4. Test results 6-19 List of measurements according to 47 CFR 15 and RSS-210 4.1 Test object data 6 4.2 Number of channels and channel spacing 7 4.3 Duty Cycle for averaging 8 4.4 Field strength at 2400 – 2483,5 MHz 9-11 4.5 Emissions outside 2400 – 2483,5 MHz (15.209) 12-16 4.6 RF Exposure 17-19 Appendix Designation pages 1 Test equipment used 5 2 Photodocumentation 11 www.tuv.at | [email protected] No. Test Report: 2024-AT-TC-EEE-1-EX-0-000005-FG-017 Grundvorlage / Basic Template: FM-TAGMBH-KBS-0100b_Grundvorlage Pr ̧fbericht akkreditiert-EN, Rev. 04 FM-TAGMBH-EE- EMV-0100a Revision: 06 Page 3 of 19 T‹V AUSTRIA GMBH Excerpts may only be reproduced with the permission of T‹V AUSTRIA GMBH. All conformity assessment activities were carried out in accordance with the QM system of T‹V AUSTRIA GMBH. Deutschstrafle 10 1230 Vienna / Austria Tel.: +43 (0)504 54 Mail: [email protected] Web: http://www.tuv.at 1. Applicant Company: VusionGroup GmbH Department: Product & Project Manager Address: A – 8072 Fernitz-Mellach; Kalsdorfer Strasse 12 Contact person: Mrs. Tamara Risek-Gmajnic EUT received on: 21.05.2024 Tests were performed on: 21.05. till 23.05.2024 www.tuv.at | [email protected] No. Test Report: 2024-AT-TC-EEE-1-EX-0-000005-FG-017 Grundvorlage / Basic Template: FM-TAGMBH-KBS-0100b_Grundvorlage Pr ̧fbericht akkreditiert-EN, Rev. 04 FM-TAGMBH-EE- EMV-0100a Revision: 06 Page 4 of 19 T‹V AUSTRIA GMBH Excerpts may only be reproduced with the permission of T‹V AUSTRIA GMBH. All conformity assessment activities were carried out in accordance with the QM system of T‹V AUSTRIA GMBH. Deutschstrafle 10 1230 Vienna / Austria Tel.: +43 (0)504 54 Mail: [email protected] Web: http://www.tuv.at 2. Description of EUT EUT: Electronic shelf labelling system Product Name: VUSION 1.5 Model: EDG3-0150-A Serial Number: Prototypes Manufacturer: VusionGroup GmbH A – 8072 Fernitz-Mellach; Kalsdorfer Strasse 12 Description: VusionGroup GmbH provided the following configuration for the measurements: Prototype with special test-firmware for continuous transmission Operating mode: The measurements were carried out at the following running states: test-firmware running, transmitting continuously Technical data EUT: Rated voltage: 3VDC Rated frequency: DC Mains voltage during the tests: 3VDC internal battery Field strength: 3,09 mV/m average @ 3m distance Frequency range: 2404,053 - 2479,285 MHz Channel separation: 0,35 MHz Climatic conditions in the emc laboratory: Relative humidity: 44% Temperature: 25∞C www.tuv.at | [email protected] No. Test Report: 2024-AT-TC-EEE-1-EX-0-000005-FG-017 Grundvorlage / Basic Template: FM-TAGMBH-KBS-0100b_Grundvorlage Pr ̧fbericht akkreditiert-EN, Rev. 04 FM-TAGMBH-EE- EMV-0100a Revision: 06 Page 5 of 19 T‹V AUSTRIA GMBH Excerpts may only be reproduced with the permission of T‹V AUSTRIA GMBH. All conformity assessment activities were carried out in accordance with the QM system of T‹V AUSTRIA GMBH. Deutschstrafle 10 1230 Vienna / Austria Tel.: +43 (0)504 54 Mail: [email protected] Web: http://www.tuv.at 3. Standards / Final result Name Title Deviation Result Title 47 CFR Part 15 eCFR 21.05.2024 RADIO FREQUENCY DEVICES none OK RSS-210 Issue 10, December 2019 Licence-Exempt Radio Apparatus: Category I Equipment none OK RSS-102 Issue 6, December 2023 Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands) none OK Result: Opinions and interpretation of testing laboratory OK: EUT passed NOK: EUT failed www.tuv.at | [email protected] No. Test Report: 2024-AT-TC-EEE-1-EX-0-000005-FG-017 Grundvorlage / Basic Template: FM-TAGMBH-KBS-0100b_Grundvorlage Pr ̧fbericht akkreditiert-EN, Rev. 04 FM-TAGMBH-EE- EMV-0100a Revision: 06 Page 6 of 19 T‹V AUSTRIA GMBH Excerpts may only be reproduced with the permission of T‹V AUSTRIA GMBH. All conformity assessment activities were carried out in accordance with the QM system of T‹V AUSTRIA GMBH. Deutschstrafle 10 1230 Vienna / Austria Tel.: +43 (0)504 54 Mail: [email protected] Web: http://www.tuv.at 4. Test results 4.1 TEST OBJECT DATA General EUT Descr…
Text truncated - open the document above for the full version.
Part 15 Antenna Information Description: The device uses an inverted-F antenna (IFA) in printed circuit board technology which is fed by a coplanar waveguide. Photograph of the assembled antenna and coplanar waveguide feed line: Ruler dimensions are in centimeter. Bottom view of the PCB: Measured gain: Details are given in the test report exhibit.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | - |

Topstock Rail is an intelligent shelf-monitoring system designed to deliver real-time visibility into product availability across both shelves and overhead storage.
Equipment Class
DTS - Digital Transmission System
Electronic Shelf Label (E300 2.6)
Equipment Class
DTS - Digital Transmission SystemElectronic shelf label
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterElectronic shelf label
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterElectronic shelf label
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter