FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. VusionGroup GmbH/
  3. 2ACQM-TSR2-0120-A

2ACQM-TSR2-0120-ATopstock Rail is an intelligent shelf-monitoring system designed to deliver real-time visibility into product availability across both shelves and overhead storage.

VusionGroup GmbH
Topstock Rail is an intelligent shelf-monitoring system designed to deliver real-time visibility into product availability across both shelves and overhead storage. - FCC ID 2ACQM-TSR2-0120-A - VusionGroup GmbH
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 06, 2026
Application Purpose
Original Equipment
Equipment Note
Topstock Rail is an intelligent shelf-monitoring system designed to deliver real-time visibility into product availability across both shelves and overhead storage.
Frequency Range
2402.00000000 - 2480.00000000
Company
VusionGroup GmbH
Country
Austria

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

TopStock Rail User Guide VusionGroup SA 24.1.2024 All information subject to change without notice. © 2025 copyright VusionGroup SA. All rights reserved. This manual may not, in whole or in part, be copied, photocopied, reproduced, translated, or converted to any written, electronic or machine-readable form without prior written consent of VusionGroup SA. 1VUSION -Topstock Rail User Guide INDEX 2VUSION -Topstock Rail User Guide Basic Features3 Technical Details4 Improper Use5 Requirements6 Support7 Compliance8 Installation9 Maintenance19 RMA33 Escalation34 BASIC TOPSTOCK FEATURES Topstock Rail is an intelligent shelf-monitoring system designed to deliver real-time visibility into product availability across both shelves and overhead storage. It utilizes specialized Topstock lenses installed along elevated racks to continuously monitor items stored above the aisles. Powered by advanced computer vision, these lenses detect product presence, identify misplaced inventory, and flag low stock conditions in Topstock, an area that has traditionally lacked visibility and often contributes to hidden out-of-stock scenarios. By digitizing this overhead inventory layer, Topstock Rail enables retailers to proactively surface available stock and trigger timely replenishment. Complementing this capability, the center lens focuses on the customer- facing shelves, capturing real-time insights into on-shelf availability, facings, and gaps. Together, the Topstock and center lenses provide a unified, end to end view of on the sales floor. This integrated system enhances replenishment efficiency, reduces out-of- stock incidents, and improves store operations by delivering precise, actionable insights to associates, ensuring products are always available where customers expect them 3VUSION -Topstock Rail User Guide TECHNICAL DETAILS TopStock Charging: Resolution: Motorized Lens: Motion Sensor: In-camera GDPR protection: Dimensions: CPU: RAM: Internal Flash: LED: Networking: Active NFC: Bluetooth: BLEStandard: WIFI: Wireless firmware update: Operating Temperature: Compliance: Packaging Unit: Weight: No 108 MP Yes Yes Yes 1205 x 52 x 48 mm ARM 32 Bit SOC 128MB 32MB RGB LED AC 2.4/5GHZ WIFI No 2.4GHz 5.4 2.4 GHz / 5 GHz (WIFI 5 PSK) 2412~2462/5250~5350/5470~5725/5725~5850MHz Yes 10 °C -40 °C CE, RoHS, FCC/IC 4 rails / box 2796 g with batteries 4VUSION -Topstock Rail User Guide IMPROPER USE •Never open or disassemble the electronic device, only the battery may be replaced by trained users. •Do not use the electronic device if it is defective. •Unauthorized changes or modifications to the electronic device and their components without the consent of VusionGroup are not allowed. •Do not use the electronic device with spare parts and accessories which are not tested and approved by VusionGroup. •NEW AND USED BATTERIES CAN BE HAZARDOUS, KEEP THEM OUT OF REACH OF CHILDREN Swallowing or placing batteries inside any part of the body may lead to severe or fatal injuries within 2 hours, due to chemical burns and potential perforation of the Esophagus. If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention. •CAUTION: The battery used in this device may present a risk of fire or chemical burn hazard if mistreated. Do not recharge, short-circuit, disassemble, heat above 100°C (212°F), incinerate or bend the battery. •Please handle the TopStock Rail carefully. •Prevent damage by water and intrusion of liquids into the TopStock Rail. Direct contact to water shall be prevented. •Do not drop the product to the floor. If TopStock Rail is dropped, check whether the TopStock Rail is still working or has any visible damages. •Strictly avoid direct contact with groceries. •Do not use harsh detergents containing alcohol or abrasive additives to clean the TopStock Rail. •We assume no liability for stolen TopStock Rails. •Keep the product and its batteries away from children. •Examine devices and make sure the battery compartment is correctly closed. Do not use the product if the compartment is not secure. •Do not throw the electronic device nor batteries into the garbage. Give them to a recycling company or contact VusionGroup for handling advice. •Preferably transport all TopStock Rails in the original packaging. Never transport loosely packed products. 5VUSION -Topstock Rail User Guide REQUIREMENTS V:Cloud •Working Vusion ESL installation •V: Cloud API + Vusion Manager Pro access for Store •Wi-Fi and BLE Access for TopStock Rail •Store internet with upload faster than 10 Mbit/s •Backoffice Data in V: Cloud •Product •Manufacturer •Item Name 6VUSION -Topstock Rail User Guide SUPPORT For further information regarding the TopStock Rail please contact us: VusionGroup Inc. Bundesstraße 16 77955 Ettenheim Germany E-Mail: [email protected] Phone: +49 (0) 7822 861996 0 7VUSION -Topstock Rail User Guide COMPLIANCE 8VUSION -Topstock Rail User Guide FCC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION TO USERS Changes or modifications not expressly approved by the party responsible for compliance could void theuser's authority to operate the equipment. FCC rulesapply to the following products: TopStock (TSR2-0120-A) INSTALLATION 9VUSION -Topstock Rail User Guide What You'll Need Make sure you have everything before starting. 1 TopStock Rails 3 Warehouse Adapter 2 Standard Adapter 4 Wire Frame Adapter 10VUSION -Topstock Rail User Guide 5 Topstock Companion App S T E P 1O F 3 —G A T H E R M A T E R I A L S Choose Your Adapter Type Select the adapter that matches your shelving. Install before mounting the rail. Standard Grocery & retail shelving 1 Press adapter firmly against front shelf edge —no gap 2 Back of adapter must lie completely flat —no tilt 3 In…

Text truncated - open the document above for the full version.

Attestation Statements

__________ VusionGroup S.A. – 55, place Nelson Mandela – CS 60106 92024 Nanterre – France A limited company with share capital of €33,687,564 Tel: + 33 (0)1 34 34 61 61 - Fax: + 33 (0)1 55 69 78 00 www.vusion.com 1 Date: June 16, 2026 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Ref: Attestation Statements Part 2.911(d)(7) Filing Applicant’s FRN #: 0024111486 FCC ID: 2ACQM-TSR2-0120-A VusionGroup GmbH (“the applicant”) certifies that, as of the date of the filing of the application, VusionGroup Inc. is our designated U.S. agent for service of process for the above referenced FCC ID. VusionGroup GmbH accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. VusionGroup Inc. accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: VusionGroup Inc. FRN #: 0033456773 Address: 3300 Olympus Blvd, Suite 200, Coppell, TX 75019, United States Contact Person: Philippe Bottine Tel.: +1 438 800 5334 Email: [email protected] Sincerely, Philipp Jauck Philippe Bottine Philipp Jauck Philippe Bottine [Applicant signature] [U.S. Agent signature] Docusign Envelope ID: 62FCF90D-8790-898C-80B8-47EB40B93BB2

Attestation Statements

__________ VusionGroup S.A. – 55, place Nelson Mandela – CS 60106 92024 Nanterre – France A limited company with share capital of €33,687,564 Tel: + 33 (0)1 34 34 61 61 - Fax: + 33 (0)1 55 69 78 00 www.vusion.com 1 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: June 29, 2026 Ref: Attestation Statements Part 2.911(d)(5)(i) and Part 2.911(d)(5)(ii) FCC ID: 2ACQM-TSR2-0120-A Part 2.911(d)(5)(i) VusionGroup GmbH (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment and does not contain anti-virus software or cybersecurity software prohibited from receiving an equipment authorization pursuant to 47 CFR 2.903, KDB 986446 D01 Covered Equipment Guidance, and FCC Covered List (www.fcc.gov/supplychain/coveredlist). Part 2.911(d)(5)(ii) VusionGroup GmbH (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, Philipp Jauck Head of IP Management & Regulatory Compliance Docusign Envelope ID: 733EE4C9-38C6-82EC-817F-A43714502661

Cover Letter(s)

__________ VusionGroup S.A. – 55, place Nelson Mandela – CS 60106 92024 Nanterre – France A limited company with share capital of €33,687,564 Tel: + 33 (0)1 34 34 61 61 - Fax: + 33 (0)1 55 69 78 00 www.vusion.com 1 Date: June 29, 2026 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Confidentiality Request regarding application for certification of FCC ID: 2ACQM-TSR2-0120-A Pursuant to Sections 0.457(d)(1)(ii) and 0.459 of the Commission’s Rules, VusionGroup GmbH hereby requests permanent confidential treatment of information accompanying this application as outlined below: • Schematics • Bill of Materials/Parts List • Block Diagrams • Operational description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457(d)(1)(ii) of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Name: Philipp Jauck Title: Head of IP Management & Regulatory Compliance Docusign Envelope ID: 733EE4C9-38C6-82EC-817F-A43714502661

Cover Letter(s)

__________ VusionGroup S.A. – 55, place Nelson Mandela – CS 60106 92024 Nanterre – France A limited company with share capital of €33,687,564 Tel: + 33 (0)1 34 34 61 61 - Fax: + 33 (0)1 55 69 78 00 www.vusion.com 1 Date: June 16, 2026 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA FCC ID: 2ACQM-TSR2-0120-A Dear Sir or Madam, We, VusionGroup GmbH, hereby authorize Min Xie of Megalab Group Inc., 150 Addison Hall Circle, Aurora, Ontario, L4G 3X8, Canada; 905-752-1925 to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. The authorization expires on 2027-06-11. Yours sincerely, Name: Philipp Jauck Title: Head of IP Management & Regulatory Compliance Docusign Envelope ID: D60AE736-F2DC-8782-8334-6C441F391035

External Photos

Report No.: ML303884-RF00Issue Date: June 29, 2026 Megalab Group Inc. – 150 Addison Hall Circle, Aurora, Ontario, L4G 3X8, Canada www.megalabinc.com – (905) 752-1925 This report may not be reproduced, except in full, without prior written approval of Megalab Group Inc. Page 1 of 4 Client:VusionGroup Inc. Product Name/Model:TopStock Gen2.0/ TSR2-0120-A FCC ID:2ACQM-TSR2-0120-A2ACQM-TSR2-0120-A External Photos Figure 1 – Front Figure 2 – Top Figure 3 – Bottom Figure 4 – Back Report No.: ML303884-RF00Issue Date: June 29, 2026 Megalab Group Inc. – 150 Addison Hall Circle, Aurora, Ontario, L4G 3X8, Canada www.megalabinc.com – (905) 752-1925 This report may not be reproduced, except in full, without prior written approval of Megalab Group Inc. Page 2 of 4 Figure 5 – Left Report No.: ML303884-RF00Issue Date: June 29, 2026 Megalab Group Inc. – 150 Addison Hall Circle, Aurora, Ontario, L4G 3X8, Canada www.megalabinc.com – (905) 752-1925 This report may not be reproduced, except in full, without prior written approval of Megalab Group Inc. Page 3 of 4 Figure 6 – Right Report No.: ML303884-RF00Issue Date: June 29, 2026 Megalab Group Inc. – 150 Addison Hall Circle, Aurora, Ontario, L4G 3X8, Canada www.megalabinc.com – (905) 752-1925 This report may not be reproduced, except in full, without prior written approval of Megalab Group Inc. Page 4 of 4 Figure 7 – Front, Main Electronic Enclosure

ID Label/Location Info

Report No.: ML303884-RF00Issue Date: June 22, 2026 Megalab Group Inc. – 150 Addison Hall Circle, Aurora, Ontario, L4G 3X8, Canada www.megalabinc.com – (905) 752-1925 This report may not be reproduced, except in full, without prior written approval of Megalab Group Inc. Page 1 of 2 Client:VusionGroup Inc. Product Name/Model:TopStock Gen2.0/ TSR2-0120-A FCC ID:2ACQM-TSR2-0120-A2ACQM-TSR2-0120-A Sample Label and Location Figure 1 – Sample Label Report No.: ML303884-RF00Issue Date: June 22, 2026 Megalab Group Inc. – 150 Addison Hall Circle, Aurora, Ontario, L4G 3X8, Canada www.megalabinc.com – (905) 752-1925 This report may not be reproduced, except in full, without prior written approval of Megalab Group Inc. Page 2 of 2 Figure 2 – Label Location

Internal Photos

Report No.: ML303884-RF00Issue Date: June 26, 2026 Megalab Group Inc. – 150 Addison Hall Circle, Aurora, Ontario, L4G 3X8, Canada www.megalabinc.com – (905) 752-1925 This report may not be reproduced, except in full, without prior written approval of Megalab Group Inc. Page 1 of 6 Client:VusionGroup Inc. Product Name/Model:TopStock Gen 2.0 / TSR2-0120-A FCC ID:2ACQM-TSR2-0120-A Internal Photos Figure 1 - Front Figure 2 - Back Report No.: ML303884-RF00Issue Date: June 26, 2026 Megalab Group Inc. – 150 Addison Hall Circle, Aurora, Ontario, L4G 3X8, Canada www.megalabinc.com – (905) 752-1925 This report may not be reproduced, except in full, without prior written approval of Megalab Group Inc. Page 2 of 6 Figure 3 – Electronic Enclosure, Front Figure 4 – Electronic Enclosure, Left Report No.: ML303884-RF00Issue Date: June 26, 2026 Megalab Group Inc. – 150 Addison Hall Circle, Aurora, Ontario, L4G 3X8, Canada www.megalabinc.com – (905) 752-1925 This report may not be reproduced, except in full, without prior written approval of Megalab Group Inc. Page 3 of 6 Figure 5 – Electronic Enclosure, Right Figure 6 – Electronic Enclosure, Compartment Report No.: ML303884-RF00Issue Date: June 26, 2026 Megalab Group Inc. – 150 Addison Hall Circle, Aurora, Ontario, L4G 3X8, Canada www.megalabinc.com – (905) 752-1925 This report may not be reproduced, except in full, without prior written approval of Megalab Group Inc. Page 4 of 6 Figure 7 – Power PCB, Top Figure 8 – Power PCB, Bottom Report No.: ML303884-RF00Issue Date: June 26, 2026 Megalab Group Inc. – 150 Addison Hall Circle, Aurora, Ontario, L4G 3X8, Canada www.megalabinc.com – (905) 752-1925 This report may not be reproduced, except in full, without prior written approval of Megalab Group Inc. Page 5 of 6 Figure 9 – Main PCB, Top Figure 10 – Main PCB, Bottom Report No.: ML303884-RF00Issue Date: June 26, 2026 Megalab Group Inc. – 150 Addison Hall Circle, Aurora, Ontario, L4G 3X8, Canada www.megalabinc.com – (905) 752-1925 This report may not be reproduced, except in full, without prior written approval of Megalab Group Inc. Page 6 of 6 Figure 11 – Daughter PCB, Top Figure 12 – Daughter PCB, Bottom

RF Exposure Info

Report No.: ML303884-RF00Issue Date: June 22, 2026 Megalab Group Inc. – 150 Addison Hall Circle, Aurora, Ontario, L4G 3X8, Canada www.megalabinc.com – (905) 752-1925 This report may not be reproduced, except in full, without prior written approval of Megalab Group Inc. Page 1 of 4 Client:VusionGroup Inc. Product Name/Model:TopStock Gen2.0/ TSR2-0120-A FCC ID:2ACQM-TSR2-0120-A ReferenceFCC KDB 447498 D04 v01 FCC RF Exposure Where the Device Under Test (DUT) can be shown to meet the requirements for an exemption pursuant to FCC 47 CFR §1.1307(b)(3), an evaluation is not required with respect to the limits on human exposure to RF emissions provided in FCC 47 CFR §1.1310. 1.Determination of Exemption As per 47 CFR §1.1307(b)(3), for single RF sources (i.e., any single fixed RF source, mobile device, or portable device), a single RF source is exempt if: A.1-mW Test Exemption: The available maximum time-averaged power is no more than 1 mW, regardless of separation distance. This exemption may not be used in conjunction with other exemption criteria other than those in paragraph (b)(3)(ii)(A) of this section. Medical implant devices may only use this exemption and that in paragraph (b)(3)(ii)(A); B.SAR-Based Exemption: The available maximum time-averaged power or effective radiated power (ERP), whichever is greater, is less than or equal to the threshold P th (mW) described in the following formula. This method shall only be used at separation distances (cm) from 0.5 centimeters to 40 centimeters and at frequencies from 0.3 GHz to 6 GHz (inclusive). P th is given by: ( ) = ( 20 ⁄ ) ≤20 20 < ≤40 Where = − 60 And ( ) = 2040 0.3 ≤ <1.5 3060 1.5 ≤ ≤6 d = the minimum separation distance (cm) in any direction from any part of the device antenna(s) or radiating structure(s) to the body of the device user. Report No.: ML303884-RF00Issue Date: June 22, 2026 Megalab Group Inc. – 150 Addison Hall Circle, Aurora, Ontario, L4G 3X8, Canada www.megalabinc.com – (905) 752-1925 This report may not be reproduced, except in full, without prior written approval of Megalab Group Inc. Page 2 of 4 C.MPE-Based Exemption: Using Table 1 and the minimum separation distance (R in meters) from the body of a nearby person for the frequency (f in MHz) at which the source operates, the ERP (watts) is no more than the calculated value prescribed for that frequency. For the exemption in Table 1 to apply, R must be at least λ/2π, where λ is the free-space operating wavelength in meters. If the ERP of a single RF source is not easily obtained, then the available maximum time- averaged power may be used in lieu of ERP if the physical dimensions of the radiating structure(s) do not exceed the electrical length of λ/4 or if the antenna gain is less than that of a half-wave dipole (1.64 linear value). Table 1 of § 1.1307(b)(3)(i)(C) - Single RF Sources Subject to Routine Environmental Evaluation RF SourceFrequency (MHz) Threshold ERP (Watts) 0.3-1.341,920 R 2 1.34-303,450 R 2 /f 2 30-3003.83 R 2 300-1,5000.0128 R 2 f 1,500-100,00019.2 R 2 2.RF Exposure Evaluation The DUT is a mobile device designed to be used in such a way that a separation distance of at least 20 centimeters is normally maintained between the RF source's radiating structure and the body of the user or nearby persons. The EUT contains 2400 – 2483.5 MHz DTS (WIFI and BLE) transmitters, UNII-1, UNII-2A, UNII-2C, and UNII-3 WLAN transmitters. ERP exemption threshold was calculated using the lowest operating frequency for each transmitter; the lower frequency resulted in a lower exemption limit. Report No.: ML303884-RF00Issue Date: June 22, 2026 Megalab Group Inc. – 150 Addison Hall Circle, Aurora, Ontario, L4G 3X8, Canada www.megalabinc.com – (905) 752-1925 This report may not be reproduced, except in full, without prior written approval of Megalab Group Inc. Page 3 of 4 2.1DUT RF Output Power TransmitterOperation Band (MHz) Conducted Power (dBm) Antenna Gain (dBi) Max ERP (dBm) Max ERP (W) Minimum Separation Distance (cm) BLE2400- 2483.5 10.31-0.27.960.00620 WLAN2400 - 2483.5 13.25-0.210.90.01220 WLAN5150 -525017.442.818.090.06420 WLAN5250 -535017.492.818.140.06520 WLAN5470 -572514.172.814.820.03020 WLAN5725 -585014.132.814.780.03020 Note: 1.ERP (dBm) = conducted power (dBm) + Antenna Gain (dBi) – 2.15 2.ERP (W) = 10^((ERP(dBm) – 30)/10) 2.2MPE-Based Exemption Evaluation Frequency (MHz) Minimum Required Separation Distance (λ/2π) (mm) Threshold ERP (W) DUT Maximum ERP (W) 24021.98780.7680.006 24121.97950.7680.012 51800.92170.7680.064 52600.90770.7680.065 55000.86810.7680.030 57450.83110.7680.030 Note: λ/2π = (3x10 8 m/s) / (2 * 3.14* f (Hz)) in meters The DUT separation distance is greater than the Minimum Required Separation Distance. And each transmitter operates below its applicable Threshold ERP Limit; thus, the RF Exposure Exemption requirement is met. According to 47 CFR §1.1307(b)(3)(i)(B), this device complies with the RF exposure test exemption. Report No.: ML303884-RF00Issue Date: June 22, 2026 Megalab Group Inc. – 150 Addison Hall Circle, Aurora, Ontario, L4G 3X8, Canada www.megalabinc.com – (905) 752-1925 This report may not be reproduced, except in full, without prior written approval of Megalab Group Inc. Page 4 of 4 2.3Simultaneous Transmission Evaluation The transmitters on the EUT are located on different SoCs. The 2.4 GHz and 5 GHz WLANs are on one SoC (SoC1) and share the same antenna; the BLE is located on the second SoC (SoC2) and has its own antenna. SoC1 could only either transmit 2.4 GHz or 5 GHz WLAN. Thus, the worst-case RF exposure is a combination of the highest ERP from each SoC. The highest ERP from SoC1 is 0.065 W and from SoC2 is 0.006 W. Per 47 CFR Section 1307(b)(3)(ii)(B), the DUT qualify for simultaneous exemption if the transmitters meet the following requirement: 0.065 0.768 + 0.006 0.768 = 0.09 < 1 The DUT qualifi…

Text truncated - open the document above for the full version.

Test Report

Megalab Group Inc. – 150 Addison Hall Circle, Aurora, Ontario, L4G 3X8, Canada www.megalabinc.com – (905) 752-1925 This report may not be reproduced, except in full, without prior written approval of Megalab Group Inc. TRRF_FCC-ICES-247-DTS_v1 RF Test Report Standard(s):FCC Part 15 Subpart 15.247, Unlicensed Intentional Radiators Issued To:VusionGroup GmbH Kalsdorfer strasse 12 Fernitz-Mellach, Styria, 8072 Austria Product Name:TopStock Gen 2.0 Model:TSR2-0120-A FCC ID:2ACQM-TSR2-0120-A Report No.ML303884B-RF01 (DTS – WIFI) Date of Issue:June 26, 2026 Report Prepared By:ReviewedBy: Min Xie, Sr. EMC/RFProject EngineerAmir Emami, Project Engineer Report No.: ML303884B-RF00 Issue Date: June 26, 2026 Client: VusionGroup GmbH Page 2 of 83 Device Under Test: TopStock Gen 2.0 Table of Contents 1.Revision History .................................................................................................................................... 3 2.Summary of Test Results ....................................................................................................................... 4 2.1Test Verdict .................................................................................................................................. 4 2.2Test Standards ............................................................................................................................. 5 2.3Test Facility .................................................................................................................................. 6 3.General Information ............................................................................................................................. 9 3.1Client Information ....................................................................................................................... 9 3.2Device Under Test (DUT) ............................................................................................................. 9 3.3Test Setup of DUT ...................................................................................................................... 10 3.4Modifications for Compliance ................................................................................................... 11 4.Test Results ......................................................................................................................................... 12 4.1Emission Bandwidth .................................................................................................................. 12 4.2Maximum Conducted Output Power ........................................................................................ 24 4.3Power Spectral Density .............................................................................................................. 31 4.4Spurious Antenna Conducted Emissions ................................................................................... 38 4.5Transmitter Spurious Radiated Emissions ................................................................................. 55 4.6Lower and Upper Band Edges.................................................................................................... 67 Report No.: ML303884B-RF00 Issue Date: June 26, 2026 Client: VusionGroup GmbH Page 3 of 83 Device Under Test: TopStock Gen 2.0 1.Revision History Project No. & Revision Report Date Initials Description ML303884B-RF00 (DTS – WIFI) June 22, 2026 MX Initial Release ML303884B-RF01 (DTS – WIFI) June 26, 2026 MX Updated address to match address in FCC database. NOTE: Latest reports marked as a revision replace any previous report and/or report revision issued under the same project number. Report No.: ML303884B-RF00 Issue Date: June 26, 2026 Client: VusionGroup GmbH Page 4 of 83 Device Under Test: TopStock Gen 2.0 2.Summary of Test Results 2.1Test Verdict Unless otherwise stated, the test data and results in this test report relate only to the sample(s) tested. Requirement Test Type Result Remark FCC 15.203 15.247(b)(4) Antenna Gain and Requirement Pass SMD with -0.2dBi Gain 15.247(a)(2) Emission Bandwidth Pass 6dB Bandwidth > 500kHz 15.247(b)(3) Average Conducted Output Power Pass < 1 Watt 15.247(d) Spurious Out of Band Emissions Pass < 30dBc 15.247(d) 15.209 Transmitter Spurious Radiated Emissions Pass --- 15.205 15.209 Lower and Upper Band Edges Pass Transmitter spurious radiated emissions which fall in the restricted bands 15.247(e) Power Spectral Density Pass < 8 dBm in 3kHz BW 15.207 Power Line Conducted Emissions Pass -- 2.1.1Test Verdict Notes and Justifications The DUT was mounted as in normal usage. See the Test Setup Photos for details. Antenna details obtained from Antenna Manufacturer’s Datasheet. As per FCC 15.203, the antenna uses an Edge mounted SMD and has less than 6dBi gain. Report No.: ML303884B-RF00 Issue Date: June 26, 2026 Client: VusionGroup GmbH Page 5 of 83 Device Under Test: TopStock Gen 2.0 2.2Test Standards Standard Description 47 CFR FCC Part 15 Subpart CCode of Federal Regulations –Radio Frequency Devices, Intentional Radiators FCC KDB 558074:2019Digital Transmission Systems, measurements and procedures ANSI C63.4:2014+C63.4a-2017Methods of Measurement of Radio-Noise Emissions from Low- Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz ANSI C63.10-2020+C63.10a- 2024 American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices ISO 17025:2017General Requirements for the Competence of Testing and Calibration Laboratories Report No.: ML303884B-RF00 Issue Date: June 26, 2026 Client: VusionGroup GmbH Page 6 of 83 Device Under Test: TopStock Gen 2.0 2.3Test Facility All tests were performed at Megalab Group Inc., located at 150 Addison Hall Circle, Aurora, ON, L4G 3X8, Canada. The 10-meter semi-anechoic chamber for radiated emission and radiated immunity is designed to handle weights of up to 10,000lb and has power capability of over 100A. The turntable is capable of…

Text truncated - open the document above for the full version.

Test Report

ABRACON IS ISO9001-2015 CERTIFIED REVISION B: 03-11-25 www.abracon.com WLAN Ceramic Chip Antenna 2450MHz, 5500 MHz ACAG0301-24505500-T 3.2 x 1.6 x 1.2 mm RoHS/RoHS II Compliant MSL Level = 1 Request Samples Check Inventory 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: Features • Miniaturized in Size: 3.2 x 1.6 x 1.2 mm • Dual band: 2400~2500 + 5150~5850 MHz • Return Loss of: < -5.5 dB • Peak Gain: 2.8 dBi • Average Total Efficiency: o 2400~2500 MHz: -3.5 dB (45%) o 5150~5850 MHz: -2.0 dB (64%) • Surface Mount (SMD) • Integration: PCB Edge Mounting Applications • Bluetooth ® / ZigBee ® / Thread/ Matter/Wi-Fi ® • Bluetooth ® / Wi-Fi ® Modules • Consumer Hearables & Wearables • Medical Wearables & Tele-Medicine • Smart Home & Smart Building • Asset Tracking & Telematics • Smart Metering • Intelligent Lighting • Wireless Remote Control Product Image ABRACON IS ISO9001-2015 CERTIFIED REVISION B: 03-11-25 www.abracon.com WLAN Ceramic Chip Antenna 2450MHz, 5500 MHz ACAG0301-24505500-T 3.2 x 1.6 x 1.2 mm RoHS/RoHS II Compliant MSL Level = 1 Request Samples Check Inventory 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: Electrical Specification Note: All measurements were performed using the evaluation board in a free-space environment. Actual performance may vary depending on factors such as the ground plane, specific application, and surrounding environment. Mechanical Specification Environmental Specification Parameter Specification Unit Operating Frequency Range 2400 ABRACON IS ISO9001-2015 CERTIFIED REVISION B: 03-11-25 www.abracon.com WLAN Ceramic Chip Antenna 2450MHz, 5500 MHz ACAG0301-24505500-T 3.2 x 1.6 x 1.2 mm RoHS/RoHS II Compliant MSL Level = 1 Request Samples Check Inventory 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: Product Dimensions and Terminal Configuration Symbol L W T a b c Dimensions 3.2±0.2 1.6±0.2 1.20.1 0.50.1 0.70.1 1.00.1 Unit: mm ABRACON IS ISO9001-2015 CERTIFIED REVISION B: 03-11-25 www.abracon.com WLAN Ceramic Chip Antenna 2450MHz, 5500 MHz ACAG0301-24505500-T 3.2 x 1.6 x 1.2 mm RoHS/RoHS II Compliant MSL Level = 1 Request Samples Check Inventory 5101 Hidden Creek Ln Spicewood TX 78669 Phone: 512-371-6159 | Fax: 512-351-8858 For terms and conditions of sales, please visit: Recommended PCB layout If there are several layers in the PCB, there is an advantage to add vias for smooth interconnection of the ground areas to avoid splits in the ground plane. It is also important that t…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Philipp Jauck
[email protected]Fax: 004359809900

Technical Contact

VusionGroup Inc.Philippe Bottine
[email protected]

3300 Olympus Blvd, Suite 200 · Coppell, 75019 · United States

Test Firm

Megalab Group Inc.Raymond Au
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz10.70 mW
215C2.41 GHz - 2.47 GHz21.10 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum conducted output power. The device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. End-users must be informed of operating requirements for satisfying RF exposure compliance. This device supports 20 MHz bandwidth modes.

Other Applications from VusionGroup GmbH

Electronic Shelf Label (E300 2.6) - FCC ID 2ACQM-EDB2-0261-A - VusionGroup GmbH
2ACQM-EDB2-0261-A

Electronic Shelf Label (E300 2.6)

May 05, 2026

Equipment Class

DTS - Digital Transmission System
2ACQM-EDG6-0260-B

Electronic shelf label

Mar 19, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
2ACQM-EDG6-0150-A

Electronic shelf label

Mar 13, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
2ACQM-EDG6-0210-A

Electronic shelf label

Mar 13, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
2ACQM-EDB2-1110-A

Electronic Shelf Label (E700 11.1)

Dec 23, 2025

Equipment Class

DTS - Digital Transmission System