Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Indoor use in dry location 1. Z-Wave on / off + dimmer control. 2. Grounded 3-wire power connection for safety. 3. Remember and restore on/off status after power failure. 4. Built-in Z-Wave Plus signal repeater to extend network range 5. S2 security and 800 Z-Wave chip for reliable wireless communication. 6. Work with all certificated Z-Wave controllers. 7. Support Long Range. Min brightness level setting( Refer to Parameter 11) 1: Press the button 5 times quickly, the LED indicator flashes slowly to enter the setting “Min brightness” mode. The lamp will adjusts to the min brightness automatically. 2: Hold the button to adjust the brightness of the bulb, select the appropriate brightness to set the min brightness. 3: Press the button 5 times quickly to confirm it (the min brightness setting is completed). The LED indicator will flashes 3 times. Max brightness level setting( Refer to Parameter 12) 1: Press the button 10 times quickly, the LED indicator flashes slowly to enter the setting “Max brightness” mode. The lamp will adjusts to the max brightness automatically. 2: Hold the button to adjust the brightness of the bulb, select the appropriate brightness to set the max brightness. 3: Press the button 10 times quickly to confirm it (the max brightness setting is completed). The LED indicator will flashes 3 times. Remark: If the setting is not confirmed at Step 3, the setting mode will be exited after 10S. Features: devices from other manufacturers and/or other applications. All non-battery operated nodes This product can be included and operated in any Z-Wave network with other Z-Wave certified within the network will act as repeaters regardless of vendor to increase the reliability of the network. This Device supports Lifeline (association group 1) supporting 1 node for lifeline communication. Group 1 must be assigned the Node ID of the primary controller where unsolicited notifications will be sent. The Z-Wave controller should set this association automatically after inclusion. Lifeline association only supports the “Device Reset Locally” function. This parameter can access you to set a timer to make the switch turn off automatically after the switch turns on.The numberentered as value (LED flashes 3 times when the configuration parameter changed.) --- Parameter =4, Size=4Value: 0– 65535(minutes); Value=0(default) disable Auto Turn-Off Timer corresponds to number of minutes. Operation: Set up on the hub. Z-Wave Dimmer Plug(800S) • LAMP-ZW2 • Specification Input: 125VAC 60Hz Frequency: 908.42 MHz Dimmable CFL/LED Loading: 200W Incandescent 100W Program button Press 1x: Manually Reset: Press the button twice quickly then hold a 3rd press for 10 seconds LED indicator Blue: Light status indicator Blue: ADD / Inclusion Purple: Remove / Exclusion Red: Network Failure Z-WAVE INTEROPERABILITY Adding Device To Z-Wave Network for QR CODE Scan here for SmartStar inclusion Note: DSK Code can be found on the packaging box. Do not remove or damage them. Z-Wave Network Configuration Adding Device To Z-Wave Network Again: If you have issues with pairing / including, please move the device as close as possible to the hub and try again--you can move to your final location when completed. Note:If the manual button doesn't light up after pressing 3 times, please reset the device: press the button twice quickly then hold a 3rd press for 10 seconds. (2)The flashing purple light means the device is already paired and also in exclusion mode. If adding fails, please do a z-wave exclusion on your z-wave controller and re-add it. 2. Once the controller is ready to add your device, press the Manual/ Program button on the smart plug 3 times quickly. The blue LED will flash quickly. 1. Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network. Now, you have completed control to turn your device ON / OFF according to groups, schedules and interactive automation programmed by your controller. If your Z-Wave certified controller features remote access, you can control your device from your mobile devices. 1. Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network. 2. Once the controller is ready to remove your device, press the manual / program button on the smart plug 3 times quickly. Manual: Press the button twice quickly then hold a 3rd press for 10 seconds. Host reset: Remove it from hub, the device will be restore to factory default. •The device is compatible with smartstart. SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code found on the top of the outlet or the back of the box with a controller providing SmartStart inclusion. No furthe action is required and the SmartStart product will be added automaticaly within 10 minutes of being switched on and in the network vicinity. •Note:Z- Wave Long Range device can only support be included via SmartStart. Extract the DSK from end device and paste it into the DSK Value in PC Controller, make sure the Long Range' option is ticked. Association Group 1: Z-Wave Plus Lifeline Association Group 2: Send Basic Set ON / Off Group 1 supports 1 node ID,Group 2 Supports maximum of 5 node ID’s To Remove The Device To Return The Device To Factory Defaults Add QR Code For LR Association Group Our Products warrant this product to be free from manufacturing defects for a period of one year from the original date of consumer purchase. This warranty is limited to the repair or replacement of this product only and does not extend to consequential or incidental damage to other products that may be used with this product. This warranty is in lieu of all other warranti- es, expressed or implied. Some states do not allow limitations on how long an implied warranty lasts or permit the exclusion or limitation of incidental or consequential damage, so the above limitations may not apply to you. This warranty gives you specific rights, and you may also have other …
Text truncated - open the document above for the full version.
VersaWirelessInc. FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 {March25,2024} U.S.AgentDesignation {VersaWirelessInc.}acknowledgestheirconsentforthefollowingcontactlocatedintheUnitedStatestoactas theiragentforserviceofprocessfortheequipmentforwhichauthorizationissought(FCCID:2AD9XLAMP-ZW2): NameandcompanyofU.S.agent:JascoProductsCompanyLLC PhysicalU.S.addressofagent:10ememorialroadOfficeoklahomacityOK73114 FRNofU.S.agent:0017309360 EmailaddressofU.S.agent:[email protected] {JascoProductsCompanyLLC}acknowledgestheirobligationtoacceptserviceofprocessonbehalfof{Versa WirelessInc.}. {VersaWirelessInc.}withtheFRN[0024185001]acceptsitsobligationtomaintainanagentforserviceof processintheUnitedStatesfornolessthanoneyearaftereitherthegranteehaspermanentlyterminatedall marketingandimportationoftheapplicableequipmentwithintheU.S.,ortheconclusionofanyCommission- relatedadministrativeorjudicialproceedinginvolvingtheequipment,whicheverislater. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirementslistedunder§ 2.911(d)(7). TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB 986446D01. Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,thegranteeisobligatedtonotify theFCCwithin30daysviathegrantingTCB. Sincerely, Signature {JustinCarlson} {GeneralManager} {VersaWirelessInc.} Signature {MarkSimpkins} {Manager} {JascoProductsCompanyLLC} 4 8 _ [ m o d e l ] U S _ A g e n t _ 2 . 9 1 1 ( d ) ( 7 ) - U , V 0 5
FCCID:2AD9XLAMP-ZW2 FCCID:2AD9XLAMP-ZW2 FCCID:2AD9XLAMP-ZW2
FCCID:2AD9XLAMP-ZW2 FCCID:2AD9XLAMP-ZW2 FCCID:2AD9XLAMP-ZW2 FCCID:2AD9XLAMP-ZW2 FCCID:2AD9XLAMP-ZW2
Report No.: PTC24021902203E-FC03 Page 1 of 8 FCC TEST REPORT FCC ID: 2AD9XLAMP-ZW2 Product : Z-Wave Dimmer Plug(800S) Model Name : LAMP-ZW2 Brand : Versa Report No. : PTC24021902203E-FC03 Prepared for Versa Wireless Inc. 103 - 19292 60th Ave. Surrey BC, CANADA Zip code: V3S 3M2 Prepared by Precise Testing & Certification Co., Ltd. Building 1, No. 6, Tongxin Road, Dongcheng Street, Dongguan, Guangdong, China. Report No.: PTC24021902203E-FC03 Page 2 of 8 TEST RESULT CERTIFICATION Applicant’s name : Versa Wireless Inc. Address : 103 - 19292 60th Ave. Surrey BC, CANADA Zip code: V3S 3M2 Manufacture's name : NIE-TECH Co., Ltd Address : Jinlian commercial center 9001, Jinxiu road No.2, Changan Town,Dongguan City, GuangDongProv., CHINA Product name : Z-Wave Dimmer Plug(800S) Model name : LAMP-ZW2 Test procedure : FCC CFR47 Part 1.1307(b)(1) Test Date : Nov. 06, 2023 to Dec. 26, 2023 Date of Issue : Mar. 25, 2024 Test Result : PASS This device described above has been tested by PTC, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of PTC, this document may be altered or revised by PTC, personal only, and shall be noted in the revision of the document. Test Engineer: Jack zhou / Engineer Technical Manager: Simon Pu / Manager Report No.: PTC24021902203E-FC03 Page 3 of 8 Contents Page 2 TEST SUMMARY ........................................................................................................................................ 4 3 GENERAL INFORMATION ....................................................................................................................... 5 3.1 GENERAL DESCRIPTION OF E.U.T. .................................................................................................... 5 4 RF EXPOSURE ........................................................................................................................................... 6 4.1 REQUIREMENTS .................................................................................................................................. 6 4.2 THE PROCEDURES / LIMIT ................................................................................................................... 6 4.3 MPE CALCULATION METHOD ............................................................................................................. 7 4.4 RF OUTPUT POWER ........................................................................................................................... 7 4.5 TEST RESULT ...................................................................................................................................... 8 Report No.: PTC24021902203E-FC03 Page 4 of 8 2 Test Summary Test Items Test Requirement Result Maximum Permissible Exposure (Exposure of Humans to RF Fields) 15.247 (i) PASS Remark: N/A: Not Applicable Report No.: PTC24021902203E-FC03 Page 5 of 8 3 General Information 3.1 General Description of E.U.T. Product Name : Z-Wave Dimmer Plug(800S) Model Name : LAMP-ZW2 Additional model : N/A Operation Frequency : 908.40MHz 908.42MHz 916.00MHz 912 MHz 920 MHz Type of Modulation : 2FSK for 908.40MHz 2FSK for 908.42MHz 2GFSK for 916.00MHz DSSS OQPSK LR for 912 MHz and 920 MHz Antenna installation : PCB Antenna Antenna Gain : -6.16 dBi Power supply : Input: AC 125V/60Hz Output: 125V 200W 60Hz Hardware Version : V1.5 Software Version : V1.2 Report No.: PTC24021902203E-FC03 Page 6 of 8 4 RF Exposure Test Requirement : FCC Part 1.1307(b)(1) Evaluation Method : KDB 447498 D01 General RF Exposure Guidance v06 4.1 Requirements Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess limit for maximum permissible exposure. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as a mobile device whereby a distance of 0.2 m normally can be maintained between the user and the device. 4.2 The procedures / limit (A) Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842 / f 4.89 / f (900 / f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100,000 5 6 (B) Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm2) Averaging Time |E|2,|H|2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f)* 30 30-300 27.5 0.073 0.2 30 300-1500 F/1500 30 1500-100,000 1.0 30 Note: f = frequency in MHz ; *Plane-wave equivalent power density Report No.: PTC24021902203E-FC03 Page 7 of 8 4.3 MPE Calculation Method E (V/m) = d G P 30 Power Density: Pd (W/m²) = 377 2 E E = Electric field (V/m) P = Peak RF output power (W) G = EUT Antenna numeric gain (numeric) d = Separation distance between radiator and human body (m) The formula can be changed to Pd = 2 377 30 d G P θφ From the peak EUT RF output power, the minimum mobile separation distance, d=0.2m, as well as the gain of the used antenna, the RF power density can be obtained 4.4 RF Output power Freq. (MHz) Field strength(max)(dBuV/m) EIRP (max) (dBm) 908.40 90.11 -5.09 908.42 90.21 -4.99 916.00 89.59 -5.61 Note: EIRP=E-104.8+20logD, Where E is the electric field strength in dBμV/m. EIRP is the equivalent isotropically radiated power in dBm. d is the specified measurement distance in m. where D=3, EIRP=E-95.2. Report No.: PTC24021902203E-FC03 Page 8 of 8 4.5 Test Result Mode Antenna Gain (numeric) Max. Peak Output Power (dBm) Tune up tolerance (dBm) Max Tune Up Power (mW) Power Density (mW/cm2) Limit of Power Density (mW/cm2) Re…
Text truncated - open the document above for the full version.
ReportNo.:RFI-LAB-RF-202306-FF05-3 QP030-E41 Page1of10 TestingReport CustomerName:NIE-TECHCo.,Ltd ProductName:ZW800_V8.42 SampleModel:ZW800_V8.42ANT ReferenceStandard:GB/T9410-2008;ANSI/IEEEStd149-1979 IssueDate:2023.6.12 Engineer:Date: Auditor:Date: Approver:Date: ReportNo.:RFI-LAB-RF-202306-FF05-3 QP030-E41 Page2of10 Version VersionNo.DateDescriptionFormulateApproval A02023.6.12Forthefirsttime,formulateZkrisEason Contents 1.GeneralInformation.........................................................................................................................3 1.1Generalinformationoftestinginstitutions...........................................................................3 1.2Testingprinciple...................................................................................................................3 1.3Testequipment......................................................................................................................4 1.4Testenvironment...................................................................................................................4 1.5Statement..............................................................................................................................4 2.SampleInformation.........................................................................................................................5 2.1Clientinformation.................................................................................................................5 2.2DescriptionofEUT(S)..........................................................................................................5 2.3EUTappearance....................................................................................................................6 2.4EUTsetupphotooffreespaceOTAtesting.........................................................................6 3.TestResults.....................................................................................................................................7 3.1Teststandard.........................................................................................................................7 3.2Testuncertainty.....................................................................................................................7 3.3Testdata................................................................................................................................8 3.3.1VSWRparameters.....................................................................................................8 3.3.2VSWRdata................................................................................................................8 3.3.3Typicalfreespaceefficiencyandgain......................................................................8 3.3.4Typicalfreespaceradiationpattern...........................................................................9 (Thefollowingisblank)..............................................................................................................10 ReportNo.:RFI-LAB-RF-202306-FF05-3 QP030-E41 Page3of10 1.GeneralInformation 1.1Generalinformationoftestinginstitutions Name ShenzhenRFI-LABCommunicationTechnologyCo.,Ltd. Address 10/FA,LingyunBld,LiufangRd,BaoanDistrict,SZ Tel 13682621346 E-mail [email protected] Equipment AlltheequipmentusedinthereportisfixedinZoneB,WestSideof1/F,Building1, TingweiIndustrialPark,No.6LiufangRoad,Bao'anDistrict,Shenzhen 1.2Testingprinciple ReportNo.:RFI-LAB-RF-202306-FF05-3 QP030-E41 Page4of10 1.3Testequipment EquipmentModelNo.SerialNo.Manufacturer Calibration date Next calibration date OTATest System RayZone-5000 RFI-LAB-RF -D00 GTS2023.3.142025.3.13 Network Analyzer E5071C RFI-LAB-RF -D01 KEYSIGHT2023.5.112024.5.10 Network Analyzer E5071C RFI-LAB-RF -C02 KEYSIGHT2023.5.112024.5.10 1.4Testenvironment Temperature 24.2°C Humidity 59%RH Pressure 100.15kPa 1.5Statement (1)Thetestresultsinthereportareonlyapplicabletothetestedsamplesandthetestedsamples workundertheenvironmentdescribedinthereport. (2)OnlyShenzhenRFI-LABCommunicationTechnologyCo.,Ltd.havetherighttomodifythe report,andthemodificationinformationshallbeannotatedintherevisionform. (3)Anyobjectiontothisreportshallberaisedwithin30daysafterformalconfirmationofthe report. (4)Thisreportisinvalidifthereisanyevidencethatthesampleinformationprovidedisfalsified. (5)Thereportisinvalidwithoutthesignatureoftheauditorandapprover. ReportNo.:RFI-LAB-RF-202306-FF05-3 QP030-E41 Page5of10 2.SampleInformation 2.1Clientinformation Name NIE-TECHCo.,Ltd Address / Contacts / Tel / E-mail / Manufacturer / 2.2DescriptionofEUT(S) ProductName ZW800_V8.42 SampleModel ZW800_V8.42ANT AntennaSize / SerialNo. / AntennaType PCBAntenna TestItem VSWR;Antennagain;Efficiency;Radiationpattern FrequencyRange 902-928MHz ReceivedDate 2023.6.08 TestDate 2023.6.09 Remark ThelengthoftheRFcableis50mm ReportNo.:RFI-LAB-RF-202306-FF05-3 QP030-E41 Page6of10 2.3EUTappearance 2.4EUTsetupphotooffreespaceOTAtesting Planform Frontview ReportNo.:RFI-LAB-RF-202306-FF05-3 QP030-E41 Page7of10 3.TestResults 3.1Teststandard NameParameterMethodStandardno. Mobile communication antenna Antennagain Genericspecification forantennasusedinthe mobilecommunications GB/T 9410-2008 Radiationpattern VSWR Antenna Radiationefficiency IEEEStandardTest ProceduresforAntennas ANSI/IEEEStd 149-1979 Gainanddirectivity 3.2Testuncertainty TheuncertaintywascalculatedonthebasisoftheGUMpublishedbyISO,usingthe inclusionfactorofK=2andthe95%confidenceleveltoexpresstheextended uncertainty. ItemUncertainty VSWR±0.3 Antennagain±0.72dB Radiationefficiency±0.72dB ReportNo.:RFI-LAB-RF-202306-FF05-3 QP030-E41 Page8of10 3.3Testdata 3.3.1VSWRparameters 3.3.2VSWRdata 3.3.3Typicalfreespaceefficiencyandgain Frequency/MHz 902915928 VSWR 6.44816.50926.5622 Frequency/MHz 902904906908910912914916918920922924926928 PeakGain/dBi -7.64-7.43-7.29-7.16-7.05-6.91-6.77-6.61-6.48-6.36-6.26-6.21-6.21-6.16 Efficiency/% 6.046.196.286.376.526.696.897.067.257…
Text truncated - open the document above for the full version.
Page 1 of 49 FCC TEST REPORT FCC ID: 2AD9XLAMP-ZW2 Product : Z-Wave Dimmer Plug(800S) Model Name : LAMP-ZW2 Brand : Versa Report No. : PTC24021902203E-FC02 Prepared for Versa Wireless Inc. 103 - 19292 60th Ave. Surrey BC, CANADA Zip code: V3S 3M2 Prepared by Precise Testing & Certification Co., Ltd Building 1, No. 6, Tongxin Road, Dongcheng Street, Dongguan, Guangdong, China Report No.: PTC24021902203E-FC02 Page 2 of 49 1 TEST RESULT CERTIFICATION Applicant’s name : Versa Wireless Inc. Address : 103 - 19292 60th Ave. Surrey BC, CANADA Zip code: V3S 3M2 Manufacture's name : NIE-TECH Co., Ltd Address : Jinlian commercial center 9001, Jinxiu road No.2, Changan Town,Dongguan City, GuangDongProv., CHINA Product name : Z-Wave Dimmer Plug(800S) Model name : LAMP-ZW2 Standards : FCC CFR47 Part 15 Section 15.247 Test procedure : ANSI C63.10:2013 Test Date : Nov. 06, 2023 to Dec. 26, 2023 Date of Issue : Mar. 25, 2024 Test Result : Pass This device described above has been tested by PTC, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of PTC, this document may be altered or revised by PTC, personal only, and shall be noted in the revision of the document. Test Engineer: Jack zhou / Engineer Technical Manager: Simon Pu / Manager Report No.: PTC24021902203E-FC02 Page 3 of 49 Contents Page 1 TEST RESULT CERTIFICATION ........................................................................................................................ 2 2 TEST SUMMARY ......................................................................................................................................................... 5 2.1 TEST SITE ........................................................................................................................................................... 6 3 GENERAL INFORMATION ..................................................................................................................................... 7 3.1 GENERAL DESCRIPTION OF E.U.T. ................................................................................................................... 7 3.2 CHANNEL LIST .................................................................................................................................................... 8 4 EQUIPMENT DURING TEST .................................................................................................................................. 9 4.1 EQUIPMENTS LIST ............................................................................................................................................ 9 4.2 MEASUREMENT UNCERTAINTY ........................................................................................................................ 11 4.3 DESCRIPTION OF SUPPORT UNITS ................................................................................................................... 12 5 CONDUCTED EMISSION ......................................................................................................................................... 13 5.1 E.U.T. OPERATION .......................................................................................................................................... 13 5.2 EUT SETUP ...................................................................................................................................................... 13 5.3 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) ................................................................................ 14 5.4 MEASUREMENT PROCEDURE ........................................................................................................................... 14 5.5 CONDUCTED EMISSION LIMIT ........................................................................................................................... 14 5.6 MEASUREMENT DESCRIPTION ......................................................................................................................... 14 5.7 CONDUCTED EMISSION TEST RESULT ............................................................................................................. 14 6 RADIATED SPURIOUS EMISSIONS ..................................................................................................................... 17 6.1 EUT OPERATION .............................................................................................................................................. 17 6.2 TEST SETUP ..................................................................................................................................................... 18 6.3 SPECTRUM ANALYZER SETUP ......................................................................................................................... 19 6.4 TEST PROCEDURE ............................................................................................................................................ 20 6.5 SUMMARY OF TEST RESULTS .......................................................................................................................... 21 7 CONDUCT BAND EDGE AND SPURIOUS EMISSIONS MEASUREMENT ................................................... 27 7.1 TEST PROCEDURE ............................................................................................................................................ 27 7.2 TEST RESULT ................................................................................................................................................... 28 8 6DB BANDWIDTH MEASUREMENT ..................................................................................................................... 33 Report No.: PTC24021902203E-FC02 Page 4 of 49 TEST PROCEDURE .......................................................…
Text truncated - open the document above for the full version.
FCCID:2AD9XLAMP-ZW2 ConductedEmissions RadiatedSpuriousEmissions From30MHz-1000MHz FCCID:2AD9XLAMP-ZW2 TestfrequencyfromAbove1GHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 920 MHz - 920 MHz | 900.00 µW |

(DSC) Wireless Shock Sensing Security Sensor for Doors/Windows
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Motion Sensor
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Security Sensor
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Intrusion Detector Sensor
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Intrusion Detector Sensor
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter