FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Kontakt Micro-Location Sp. z o.o./
  3. 2ADAO-KHWPO120F001

2ADAO-KHWPO120F001Portal Light 2

Kontakt Micro-Location Sp. z o.o.
Portal Light 2 - FCC ID 2ADAO-KHWPO120F001 - Kontakt Micro-Location Sp. z o.o.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 11, 2024
Application Purpose
Original Equipment
Date of Application
Jan 11, 2024
Equipment Note
Portal Light 2
Frequency Range
2402.00000000 - 2480.00000000
Company
Kontakt Micro-Location Sp. z o.o.
Country
Poland

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Kontakt.io Portal Light 2 User Manual Read carefully before installation! Manual applies to standard box set of 70pcs The Portal Light 2 is Kontakt.io's Bluetooth® Low Energy (LE) gateway device. It scans and detectsKontakt.io BLE devices and sends received BLE data to Kio Cloud over the facility's existing Wi-Fi network. With a Kontakt.io subscription, BLE beacons, tags, and badges are automatically processed in Cloud and Applications and can receive configuration/firmware updates over their BLE connection to a Portal Light 2. Portal Light2 Installation Pre-requisites  Power socket(100-240VAC,50-60Hz)  WiFi network(2.4 or 5GHz) Main Features ★ Location services, BLE device data in real-time and constant connection to Kontakt.io Cloud via Wi-Fi ★Dual BLE:RTK and STM BLE modules ★Simplified deployment with Kontakt.io mobile application ★Visual status RGBLED ★Over-the-air(OTA)configuration and firmware updates ★Power outlet pass through(upto12AandNEMA5- 15USplug)–prevent occupying power outlets ★No-pass-through model available ★ Power disconnect alert – advertising special warning BLE frame for short period of time after mains power is lost Electrical Specifications - For use with NEMA 5-15Receptaclesandotherplug- compatible.Mustnotexceed load ratings -Input:100-240VAC, 12AMax,50/60Hz - 12Aratedforpass-throughoutlet - InternalDCline:3-5VDC - Functionalmaxpower:3W - Coin-cell battery for powering RTC(keep accurate time for Wi-Fi certificates authorization) CR1025 3.0V, 30mAh Environmental Specifications - Operating Temperature -20 to 60 deg.C - Storage Temperature -20C to 85 deg.C - Operating Humidity 10%-95% RH(non-condensing) - Storage Humidity 5%-95% RH(non-condensing) - IP54 Wi-Fi Specifications Wireless Standards: IEEE802.11a/b/g/n Frequency range:2.412-2.462GHz &5.180-5.825GHz Data Rates:802.11a: 6,9,12,18,24,36,48,54 Mbps/802.11b: 1,2,5.5,11 Mbps/802.11g 6,9,12,18,24,36,48,54 Mbps MCS0--MCS7 @ HT20 /2.4GHz and 5GHz band MCS0--MCS7@HT40/2.4GHz and 5GHz band Work Mode: Station Security: WEP,WPA™/WPA2™PSK,WPA2 Enterprise, EAPTLS, EAPTTLS, PEAPv0, WPA3™ Personal Wi-Fi output power: 15 dBm Bluetooth Specifications ➤ QFN48:ARM®V8MCU/ 2.402GHz -2.480GHz Max output power: +8dBm ➤BlueNRG-355MC:Cortex®-M0+/2.402GHz-2.480GHz Max output power: +4.35dBm ➤Bluetooth LE5.0 and 5.2 compatible BW16 module FCC ID:2AHMR-BW16 Applications Portal Light 2 is used in offices, educational facilities, other businesses tablishments, residences (homes), churches, government or private institutions and other similar environments. The installation in healthcare facilities can be made on discretion of AHJ (Authority N Having Jurisdiction). Portal Light2 Models o Portal Light 2/PNR:KHWPO120F001 Model of device with pass-through functionality. o Portal Light 2 NPT / PNR: KHWPO121F001 Model of device without pass-through functionality in corporating out let wall-plate mounting tab. PLEASEREAD AND FOLLOW BELOW PRECAUTIONSCAREFULLY FOR PNR: KHWPO121F001 NOTICE– Local Regulations in Canada do not permit use of a mounting tab. In Canada, do not use the mounting tab to attach the unit to an outlet. AVIS– Lesréglementationslocalesau Canada n'autorisent pas l'utilisation d'une languette demontage. Au Canada, n'utilisez pas la languette demontagepour fixerl'appareilàuneprise. WARNING! o Risk of Electric Shock – Disconnect power to the receptacle before installing or removing the unit.Whenremovingreceptaclecoverscrew,covermayfa llacrossplugpinsorreceptaclemaybecomedisplaced; o Use only with duplex receptacle having center screw; o Secure unit in place by receptacle cover screw. Installation & Commissioning - Portal Lights 2 are deployed in the area according to floor plans and RTLS design provided by Kontakt.io. Depending on selected RF density and room size it could require up to several devices to be installed in a single room. - After Portal Light 2 is connected to power it establishes connection to local Wi-Fi network that was pre- configured at factory. In case Wi-Fi credential are not available before shipping, user is able to utilize Kontakt.io mobile application to configure Wi-Fi SSID and Pass word with help of BLEOTA configuration functionality. - User must select location of deployed device on Kontakt.io Smart Location App using mobile or we bapplications. Portal Light 2 will show up as online on UI interface. Data is accessible via APIs or as outcomes in use-case specific applications. FOR MOREINFOPLEASE CONTACTMANUFACTURER TECHNICAL SUPPORT:[email protected] WARNING Portal Light 2 contains electronic elements which should be properly disposed of. If a Portal Light 2 needs to be disposed of, please contact the manufacturer technical support first. FCC Caution This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase th…

Text truncated - open the document above for the full version.

Attestation Statements

CFR 47 §2.911(d)(5)(i) Attestation Letter Kontakt Micro-Location Sp. z o.o. Address: ul.Stoczniowcow 3, 30-709 Krakow, Poland Email: [email protected] Tel: 0048123793445 Attestation Letter Date: 2023-12-15 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(i) Filing FCC ID:2ADAO-KHWPO120F001 Kontakt Micro-Location Sp. z o.o. certifies that the equipment for which authorization is sought, is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Signature Joanna Wolczanska Ms Doc ID: 72c180aa40f8ea176076a754f376921464a57f9f

Attestation Statements

CFR 47 §2.911 (d)(5)(ii) Attestation Letter Kontakt Micro-Location Sp. z o.o. Address: ul.Stoczniowcow 3, 30-709 Krakow, Poland Email: [email protected] Tel: 0048123793445 Attestation Letter Date: 2023-12-15 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(5)(ii) Filing FCC ID: 2ADAO-KHWPO120F001 Kontakt Micro-Location Sp. z o.o. certifies that as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Signature Joanna Wolczanska Ms Doc ID: 72c180aa40f8ea176076a754f376921464a57f9f

Attestation Statements

U.S. AGENT LETTER OF ATTESTATION Date: 2023-12-15 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 §2.911(d)(7) Filing FCC ID: 2ADAO-KHWPO120F001 Kontakt Micro-Location Sp. z o.o. certifies that, as of the date of the filing of the application, Iconsigh Inc. is our designated U.S. agent for service of process for the above referenced FCC ID. Kontakt Micro-Location Sp. z o.o. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Iconsigh Inc. accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Company Name: Iconsigh Inc. Address: 2310 Homestead Road, Suite C1, Los Altos, CA, 94024, USA FRN: 0033398652 Tel.: +1 (408) 320-9867 Email: [email protected] Signed by (printed name): Benjamin Kaur Signature: Applicant: Kontakt Micro-Location Sp. z o.o. Address: ul.Stoczniowcow 3, 30-709 Krakow, Poland FRN: 0023964000 Tel: 0048123793445 Email: [email protected] Signed by: Joanna Wolczanska Signature: Doc ID: 72c180aa40f8ea176076a754f376921464a57f9f

Cover Letter(s)

Kontakt Micro-Location Sp. z o.o. Address: ul.Stoczniowcow 3, 30-709 Krakow, Poland Email: [email protected] Tel: 0048123793445 QA-FR-170-B 7/29/2014 FCC Authorization Date: 2023-12-15 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We, Kontakt Micro-Location Sp. z o.o., the undersigned, hereby authorizes World Alliance Testing & Certification (Shenzhen) Co., Ltd to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by World Alliance Testing & Certification (Shenzhen) Co., Ltd on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely, Signature Joanna Wolczanska Ms Doc ID: 72c180aa40f8ea176076a754f376921464a57f9f

Cover Letter(s)

Kontakt Micro-Location Sp. z o.o. Address: ul.Stoczniowcow 3, 30-709 Krakow, Poland Email: [email protected] Tel: 0048123793445 FCC Confidential Authorization Date: 2023-12-15 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2ADAO-KHWPO120F001 In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Kontakt Micro-Location Sp. z o.o. hereby requests long-term confidential treatment of information accompanying this application as outlined below: •Block Diagram •Schematics •Operation Description •Part list The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely, Signature J oanna Wolczanska Ms

Cover Letter(s)

Kontakt Micro-Location Sp. z o.o. Address: ul.Stoczniowcow 3, 30-709 Krakow, Poland Email: [email protected] Tel: 0048123793445 Date: 2023-12-15 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 To whom it may concern: Our product Portal Light 2, Model: KHWPO120F001; FCC ID: 2ADAO-KHWPO120F001, for marketing purpose, this product only supports BLE 1M&2M, BT(GFSK, π/4-DQPSK, 8DPSK), 2.4G Wi-Fi(2412-2462MHz, 802.11b/g/n20/n40 modes), 5G Wi-Fi(5180-5240 MHz, 5745-5825MHz, 802.11 a/n20/n40 modes).The other functions, bands and modes was disabled to use by manufacturer in the software, the end user has no capability to activate it. Sincerely, Signature Joanna Wolczanska Ms Doc ID: 72c180aa40f8ea176076a754f376921464a57f9f

External Photos

Report No.: RWAY202300022 Page 1 of 3 EUT EXTERNAL PHOTOGRAPHS Report No.: RWAY202300022 Page 2 of 3 Report No.: RWAY202300022 Page 3 of 3

ID Label/Location Info

Portal Light 2 PNR: KHWPO120F001 | Manufacturer: Kontakt.io Designed in California | Produced in China FCC ID: 2ADAO-KHWPO121F001 For use with NEMA Receptacles 100V-240V AC 50-60Hz Max 0.12A Power rating: 3W Battery: CR1025 3V, 30mAh 00:00:00:00:00:00 E537875 INFORMATION TECHNOLOGY EQUIPMENT Pantone Cool Gray 3 C 4mm Centered Pantone Black 6 C 4mm 4mm 18mm QR Code (10x10mm) Font:Nunito Sans 8pt Font:Nunito Sans 4pt Contain FCC ID: 2AHMR-BW16

Internal Photos

Report No.: RWAY202300022 Page 1 of 4 EUT INTERNAL PHOTOGRAPHS Report No.: RWAY202300022 Page 2 of 4 BT/Wi-Fi ANT Contains FCC ID: 2AHMR-BW16 Report No.: RWAY202300022 Page 3 of 4 Report No.: RWAY202300022 Page 4 of 4 BLE ANT

RF Exposure Info

Report No.: RWAY202300022C Report Template: TR-4-E-011 Page 1 of 7 RF Exposure Evaluation Report Report No.: RWAY202300022C Applicant: Kontakt Micro-Location Sp. z o.o Address: ul.Stoczniowcow 3, 30-709 Krakow, Poland Product Name: Portal Light 2 Product Model: KHWPO120F001 Multiple Models: N/A Trade Mark: Kontakt.io FCC ID: 2ADAO-KHWPO120F001 Standards: 47 CFR §1.1307 KDB 447498 D04 Interim General RF Exposure Guidance v01 Test Date: 01 Dec, 2023 Test Result: Complied Report Date: 04 Dec, 2023 Reviewed by: Approved by: Abel Chen Project Engineer Jacob Kong Manager Prepared by: World Alliance Testing and Certification (Shenzhen) Co., Ltd No. 1002, East Block, Laobing Building, Xingye Road 3012, Xixiang street, Bao'an District, Shenzhen, Guangdong, People’s Republic of China This report may contain data that are not covered by the NVLAP accreditation and shall be marked with an asterisk “★” Report No.: RWAY202300022C Report Template: TR-4-E-011 Page 2 of 7 Announcement 1.This test report shall not be reproduced in full or partial, without the written approval of World Alliance Testing and Certification (Shenzhen) Co., Ltd 2. The results in this report apply only to the sample tested. 3. This sample tested is in compliance with the limits of the above regulation. 4. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. 5. The information marked “#” is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included. Revision History Version No. Issued Date Description 00 04 Dec, 2023 Original Report No.: RWAY202300022C Report Template: TR-4-E-011 Page 3 of 7 Contents 1 General Information ............................................................................................................................ 4 1.1 Client Information ...................................................................................................................... 4 1.2 Product Description of EUT ....................................................................................................... 4 1.3 Laboratory Location ................................................................................................................... 4 2 RF Exposure Evaluation ..................................................................................................................... 5 2.1 Standard .................................................................................................................................... 5 2.2 Result......................................................................................................................................... 7 Report No.: RWAY202300022C Report Template: TR-4-E-011 Page 4 of 7 1 General Information 1.1 Client Information Applicant: Kontakt Micro-Location Sp. z o.o Address: ul.Stoczniowcow 3, 30-709 Krakow, Poland Manufacturer: Kontakt Micro-Location Sp. z o.o Address: ul.Stoczniowcow 3, 30-709 Krakow, Poland 1.2 Product Description of EUT The EUT is Portal Light 2 that contains BLE radios and a certified BT/Wi-Fi module. Sample Serial Number E-4 (assigned by WATC) Sample Received Date 2023-11-30 Sample Status Good Condition Frequency Range 2402MHz - 2480MHz(BLE1M/2M) Maximum Conducted Output Power 2402MHz - 2480MHz: 4.35dBm dBm Modulation Technology GFSK Antenna Gain # 1.21dBi Spatial Streams SISO (1TX, 1RX) Power Supply AC 120V/60Hz Operating temperature # -20 deg.C to +60 deg.C Adapter Information N/A Modification Sample No Modification by the test lab 1.3 Laboratory Location World Alliance Testing and Certification (Shenzhen) Co., Ltd No. 1002, East Block, Laobing Building, Xingye Road 3012, Xixiang street, Bao'an District, Shenzhen, Guangdong, People’s Republic of China Tel: +86-755-29691511, Email: [email protected] The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the FCC Public Access Link (PAL) database, FCC Registration No. : 463912, the FCC Designation No. : CN5040. The lab has been recognized by Innovation, Science and Economic Development Canada to test to Canadian radio equipment requirements, the CAB identifier: CN0160. Report No.: RWAY202300022C Report Template: TR-4-E-011 Page 5 of 7 2 RF Exposure Evaluation 2.1 Standard According to §1.1307(b)(3)(i), For single RF sources (i.e., any single fixed RF source, mobile device, or portable device, as defined in paragraph (b)(2) of this section): A single RF source is exempt if: (A) The available maximum time-averaged power is no more than 1 mW, regardless of separation distance. This exemption may not be used in conjunction with other exemption criteria other than those in paragraph (b)(3)(ii)(A) of this section. Medical implant devices may only use this exemption and that in paragraph (b)(3)(ii)(A); (B) Or the available maximum time-averaged power or effective radiated power (ERP), whichever is greater, is less than or equal to the threshold Pth (mW) described in the following formula. This method shall only be used at separation distances (cm) from 0.5 centimeters to 40 centimeters and at frequencies from 0.3 GHz to 6 GHz (inclusive). Pth is given by: (C) Or using Table 1 and the minimum separation distance (R in meters) from the body of a nearby person for the frequency (f in MHz) at which the source operates, the ERP (watts) is no more than the calculated value prescribed for that frequency. For the exemption in Table 1 to apply, R must be at least λ/2π, where λ is the free-space operating wavelength in meters. If the ERP of a single RF source is not easily obtained, then the available maximum time-averaged power may be used in lieu of ERP if the physical dimensions of the radiating structure(s) do not exceed the electrical length of λ/4 or if the antenna gain is less than …

Text truncated - open the document above for the full version.

Test Report

深圳云里物里科技股份有限公司 产品天线测试报告(TheAntennaTestReport) Y-YB-CR-115V001密级:绝密/confidentiality 第1页共8页 AntennaCoding:ANT-BBNCNC23010 AntennaType:PCBAntenna ModeloftheDUT : DG2 AntennaManufacturer:ShenzhenMinewTechnologiesCo.,Ltd. 1、TechnicalSpecification ElectricalSpecifications FrequencyRange(MHz) 2400-2480 InputImpedance(Ω) 50 ReturnLoss ( dB )< -10 VSWR < 2 PeakGain(dBi) 1.21 PolarizationTypeLinearpolarization MechanicalSpecifications AntennaSize(mm)19.7*5.54 RadiatorCuprum 2、Theshapeandsizeoftheantenna Adress:3rd Floor, I Building, Gangzhilong Science Park, Qinglong Road, Longhua District, Shenzhen City 518000 China 深圳云里物里科技股份有限公司 产品天线测试报告(TheAntennaTestReport) Y-YB-CR-115V001密级:绝密/confidentiality 第2页共8页 3、Theresultofthetest 3.1S11 3.2TestEnvironment 深圳云里物里科技股份有限公司 产品天线测试报告(TheAntennaTestReport) Y-YB-CR-115V001密级:绝密/confidentiality 第3页共8页 3.3GainandEfficiency 深圳云里物里科技股份有限公司 产品天线测试报告(TheAntennaTestReport) Y-YB-CR-115V001密级:绝密/confidentiality 第4页共8页 3.43D PolarPlot 2402MHz 2426MHz 深圳云里物里科技股份有限公司 产品天线测试报告(TheAntennaTestReport) Y-YB-CR-115V001密级:绝密/confidentiality 第5页共8页 2480MHz 3.52DRadiationPattern (1)E1,XZPlane,phi=0 2402MHz 深圳云里物里科技股份有限公司 产品天线测试报告(TheAntennaTestReport) Y-YB-CR-115V001密级:绝密/confidentiality 第6页共8页 2426MHz 2480MHz (2)E2,YZPlane,phi=90° 2402MHz 深圳云里物里科技股份有限公司 产品天线测试报告(TheAntennaTestReport) Y-YB-CR-115V001密级:绝密/confidentiality 第7页共8页 2426MHz 2480MHz (3)H,XYplane,theta=90° 2402MHz 深圳云里物里科技股份有限公司 产品天线测试报告(TheAntennaTestReport) Y-YB-CR-115V001密级:绝密/confidentiality 第8页共8页 2426MHz 2480MHz

Test Report

Report No.: RWAY202300022B Report Template: TR-4-E-008 Page 1 of 32 FCC Test Report Report No.: RWAY202300022B Applicant: Kontakt Micro-Location Sp. z o.o Address: ul.Stoczniowcow 3, 30-709 Krakow, Poland Product Name: Portal Light 2 Product Model: KHWPO120F001 Multiple Models: N/A Trade Mark: Kontakt.io FCC ID: 2ADAO-KHWPO120F001 Standards: FCC CFR Title 47 Part 15C (§15.247) Test Date: 01 Dec, 2023 to 04 Dec, 2023 Test Result: Complied Report Date: 04 Dec, 2023 Reviewed by: Approved by: Abel Chen Project Engineer Jacob Kong Manager Prepared by: World Alliance Testing and Certification (Shenzhen) Co., Ltd No. 1002, East Block, Laobing Building, Xingye Road 3012, Xixiang street, Bao'an District, Shenzhen, Guangdong, People’s Republic of China This report may contain data that are not covered by the NVLAP accreditation and shall be marked with an asterisk “★” Report No.: RWAY202300022B Report Template: TR-4-E-008 Page 2 of 32 Announcement 1.This test report shall not be reproduced in full or partial, without the written approval of World Alliance Testing and Certification (Shenzhen) Co., Ltd 2. The results in this report apply only to the sample tested. 3. This sample tested is in compliance with the limits of the above regulation. 4. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. 5. The information marked “#” is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Customer model name, addresses, names, trademarks etc. are included. Revision History Version No. Issued Date Description 00 04 Dec, 2023 Original Report No.: RWAY202300022B Report Template: TR-4-E-008 Page 3 of 32 Contents 1 General Information ............................................................................................................................ 4 1.1 Client Information ...................................................................................................................... 4 1.2 Product Description of EUT ....................................................................................................... 4 1.3 Antenna information .................................................................................................................. 4 1.4 Related Submittal(s)/Grant(s) .................................................................................................... 5 1.5 Measurement Uncertainty ......................................................................................................... 5 1.6 Laboratory Location ................................................................................................................... 5 1.7 Test Methodology ...................................................................................................................... 5 2 Description of Measurement .............................................................................................................. 6 2.1 Test Configuration ...................................................................................................................... 6 2.2 Test Auxiliary Equipment ........................................................................................................... 6 2.3 Test Setup .................................................................................................................................. 7 2.4 Test Procedure .......................................................................................................................... 9 2.5 Measurement Method.............................................................................................................. 10 2.6 Measurement Equipment ........................................................................................................ 10 3 Test Results ....................................................................................................................................... 12 3.1 Test Summary .......................................................................................................................... 12 3.2 Limit ......................................................................................................................................... 13 3.3 AC Line Conducted Emissions Test Data ................................................................................ 14 3.4 Radiated emission Test Data ................................................................................................... 16 3.5 RF Conducted Test Data ......................................................................................................... 23 3.5.1 6 dB Emission Bandwidth and 99% Occupied Bandwidth ........................................... 23 3.5.2 Maximum Conducted Peak Output Power ................................................................... 23 3.5.3 Power Spectral Density ................................................................................................ 23 3.5.4 100 kHz Bandwidth of Frequency Band Edge ............................................................. 24 3.5.5 Duty Cycle .................................................................................................................... 24 4 Test Setup Photo ............................................................................................................................... 31 5 E.U.T Photo ........................................................................................................................................ 32 Report No.: RWAY202300022B Report Template: TR-4-E-008 Page 4 of 32 1 General Information 1.1 Client Information Applicant: Kontakt Micro-Location Sp. z o.o Address: ul.Stoczniowcow 3, 30-709 Krakow, Poland Manufacturer: Kontakt Micro-Location Sp. z o.o Address: ul.Stoczniowcow 3, 30-709 Krakow, Poland 1.2 Product…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No.: RWAY202300022 Page 1 of 4 TEST SETUP PHOTOGRAPHS AC Line Conducted Emission Report No.: RWAY202300022 Page 2 of 4 Radiated Emission Below 1GHz Report No.: RWAY202300022 Page 3 of 4 Above 1 GHz Report No.: RWAY202300022 Page 4 of 4

Contact Information

Applicant

Joanna Wolczanska(Ms)
[email protected]0048123793445Fax: +48

Test Firm

World Alliance Testing & Certification (Shenzhen)Stefani Hu
[email protected]0755-29691511

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz3.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter device.

Other Applications from Kontakt Micro-Location Sp. z o.o.

Dispensor Beacon ES10 - FCC ID 2ADAO-KHWSN301F001 - Kontakt Micro-Location Sp. z o.o.
2ADAO-KHWSN301F001

Dispensor Beacon ES10

Aug 25, 2026

Equipment Class

DTS - Digital Transmission System
Universal Dispensor Beacon - FCC ID 2ADAO-KHWSN300F001 - Kontakt Micro-Location Sp. z o.o.
2ADAO-KHWSN300F001

Universal Dispensor Beacon

Aug 24, 2026

Equipment Class

DTS - Digital Transmission System
Nano Tag IR - FCC ID 2ADAO-KHWBC701F001 - Kontakt Micro-Location Sp. z o.o.
2ADAO-KHWBC701F001

Nano Tag IR

Jul 18, 2024

Equipment Class

DTS - Digital Transmission System
Portal Light 2 IR - FCC ID 2ADAO-KHWPO130F001 - Kontakt Micro-Location Sp. z o.o.
2ADAO-KHWPO130F001

Portal Light 2 IR

Apr 01, 2024

Equipment Class

DTS - Digital Transmission System
Beam Mini - FCC ID 2ADAO-KHWPO300F001 - Kontakt Micro-Location Sp. z o.o.
2ADAO-KHWPO300F001

Beam Mini

Jul 27, 2023

Equipment Class

DTS - Digital Transmission System