2ADSY-BCS1HHEALBE Scale

Healbe Corporation
HEALBE Scale - FCC ID 2ADSY-BCS1H - Healbe Corporation
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 11, 2025
Application Purpose
Original Equipment
Equipment Note
HEALBE Scale
Frequency Range
2402.00000000 - 2480.00000000
Company
Healbe Corporation
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Healbe Corporation 2025-11-27 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2ADSY-BCS1H) [Healbe Corporation] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, Artem Shipitsyn Mr Healbe Corporation 541 Jefferson Avenue Suite 100, Redwood City, CA 94063 Healbe Corporation 2025-11-27 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2ADSY-BCS1H) [Healbe Corporation] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Artem Shipitsyn Mr Healbe Corporation 541 Jefferson Avenue Suite 100, Redwood City, CA 94063

External Photos

External Photographs View of EUT-1 View of EUT-2 Page 2 of 4 View of EUT-3 View of EUT-4 Page 3 of 4 View of EUT-5 View of EUT-6 Page 4 of 4 View of EUT-7

Internal Photos

Internal Photographs Internal View of EUT-1 Internal View of EUT-2 Page 2 of 3 Internal View of EUT-3 Internal View of EUT-4 Antenna Page 3 of 3 Internal View of EUT-5

RF Exposure Info

RF EXPOSURE EVALUATION EUT Specification EUT HEALBE Scale Model Number BCS1H Series Model 700A, B6H, B12H, B30H, B40H, B41H, B80H, B90H, BCS2H, B21H, B16H, B92B, B200H, B700H Model Difference The difference of the models are model name and product appearance color, others are the same. FCC ID 2ADSY-BCS1H Antenna gain (Max) -1.08dBi Operation Frequency 2402 MHz to 2480 MHz Power Supply Battery 4.5V Classification Per Stipulated Test Standard §15.247(i), §2.1093 Modulation GFSK Max. output power 4.45Bm (0.0028W) Test Requirement: According to ß15.247(i) and ß1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. Routine SAR evaluation refers to that specifically required by ß2.1093, using measurements or computer simulation. When routine SAR evaluation is not required, portable transmitters with output power greater than the applicable low threshold require SAR evaluation to quality for TCB approval. One antenna is available for the EUT. The minimum separation distance is 5mm. Page 2 of 2 Measurement Result BLE: Transmit Frequency (MHz) Mode Measured Power (dBm) Tune up Power (dBm) Max tune up power (dBm) Calculation Result 1-g SAR 2402 BLE 1M 4.45 4±1 5 0.98 3 According to KDB 447498, no stand-alone required for BT antenna, and no simultaneous SAR measurement is required. Signature: Shawn Wen Date: 2025-12-2

Test Report

ShenzhenElinkThingsCo.,Ltd -1- Tel:(86)0755-81773367E-mail:[email protected] Address:5thFloor,QiaohongshengPark,YintianInudstryArea,XixiangStreet,BaoAnDistrict,Shenzhen,518100 AntennaSpecification Version:V2.3 UpdateDate:September06,2023 ShenzhenYilianInternetofThingsCo.,Ltd.Allrights reserved Thespecificationsofthisproductaresubjecttochangewithoutnotice. ShenzhenYilianInternetofThingsCo.,Ltd.reservestherighttomakechangestothespecifications andmaterialscontainedinitwithoutpriornotice,andatthesametimedamage(includingconsequential damage)causedbytrustinthematerialscited,includingButnotlimitedtoerrorsinprintingandother errorsrelatedtothispublication,YilianInternetofThingswillnotbeheldresponsible. ShenzhenElinkThingsCo.,Ltd -1- Tel:(86)0755-81773367E-mail:[email protected] Address:5thFloor,QiaohongshengPark,YintianInudstryArea,XixiangStreet,BaoAnDistrict,Shenzhen,518100 Contents Contents...................................................................................................................................................................................-1- 1Antennasize(Unit:mm).................................................................................................................................................-1- 2Antennaspecificationparameters........................................................................................................................................-2- 3Testcondition........................................................................................................................................................................-2- 4Testingenvironment..............................................................................................................................................................-4- 5Deoningfrequencyofantennanetwork...............................................................................................................................-6- 6Antennatestefficiency.........................................................................................................................................................-6- 72Dfig(2450MHz)...................................................................................................................................................................-7- 83Dfig.....................................................................................................................................................................................-8- ShenzhenElinkThingsCo.,Ltd -1- Tel:(86)0755-81773367E-mail:[email protected] Address:5thFloor,QiaohongshengPark,YintianInudstryArea,XixiangStreet,BaoAnDistrict,Shenzhen,518100 1Antennasize ( Unit : mm ) BM16 ShenzhenElinkThingsCo.,Ltd -2- Tel:(86)0755-81773367E-mail:[email protected] Address:5thFloor,QiaohongshengPark,YintianInudstryArea,XixiangStreet,BaoAnDistrict,Shenzhen,518100 2Antennaspecificationparameters numberParameteritemDescription 1Centeroperatingfrequency2441MHz 2Workbandwidth2400---2480Mhz 3Rateofdatasignalling1Mbps 4AntennatypeOn-boardPCBantenna(default) 5Antennagain-1.08dBi 6Impedance50ohm 7ModemtypeGFSK 3Testcondition TestengineerJesseGuan Phone(+86)18975824147 [email protected] ConfirmJoyZhu Date2023/9/5 ShenzhenElinkThingsCo.,Ltd -3- Tel:(86)0755-81773367E-mail:[email protected] Address:5thFloor,QiaohongshengPark,YintianInudstryArea,XixiangStreet,BaoAnDistrict,Shenzhen,518100 ShenzhenElinkThingsCo.,Ltd -4- Tel:(86)0755-81773367E-mail:[email protected] Address:5thFloor,QiaohongshengPark,YintianInudstryArea,XixiangStreet,BaoAnDistrict,Shenzhen,518100 4Testingenvironment ShenzhenElinkThingsCo.,Ltd -5- Tel:(86)0755-81773367E-mail:[email protected] Address:5thFloor,QiaohongshengPark,YintianInudstryArea,XixiangStreet,BaoAnDistrict,Shenzhen,518100 ShenzhenElinkThingsCo.,Ltd -6- Tel:(86)0755-81773367E-mail:[email protected] Address:5thFloor,QiaohongshengPark,YintianInudstryArea,XixiangStreet,BaoAnDistrict,Shenzhen,518100 5Deoningfrequencyofantennanetwork Thereturnlossoftheantennaat2.445ghzis-30dBandtheimpedanceisabout50.Bandwidth80m 6Antennatestefficiency passivetestfor2.4g Freq(MHz)Gain(dBi)Efficiency(dB)Efficiency(%) 2400-2.125670268-6.51298217822.32039018 2410-1.839793728-6.35055515823.17098436 2420-1.64029678-6.24681065523.7311582 2430-1.328848956-5.92515296425.5555189 2440-1.132319256-5.79955308526.30538676 2450-1.087960046-5.84929926526.00579133 2460-1.316358881-6.00672172325.08001707 2470-1.579335991-6.24506749923.74068524 2480-1.962892418-6.45421219322.62448909 ShenzhenElinkThingsCo.,Ltd -7- Tel:(86)0755-81773367E-mail:[email protected] Address:5thFloor,QiaohongshengPark,YintianInudstryArea,XixiangStreet,BaoAnDistrict,Shenzhen,518100 2490-2.50538583-6.75344940721.11811056 2500-3.031894388-7.25223622418.8267943 72Dfig(2450MHz) (1)XY-Plane (2)ZY-Plane (3)ZX-Plane 3 1 2 ShenzhenElinkThingsCo.,Ltd -8- Tel:(86)0755-81773367E-mail:[email protected] Address:5thFloor,QiaohongshengPark,YintianInudstryArea,XixiangStreet,BaoAnDistrict,Shenzhen,518100 83Dfig

Test Report

TRF No.: 04-E001-0B TRF Originator: GTG TRF Date: 2023-12-13 Web: www.gtggroup.com E-mail: [email protected] Tel.: 86-400 755 8988 CFR 47 FCC PART 15 SUBPART C(DTS) TEST REPORT For HEALBE Scale MODEL NUMBER: BCS1H, 700A, B6H, B12H, B30H, B40H, B41H, B80H, B90H, BCS2H, B21H, B16H, B92B, B200H, B700H REPORT NUMBER: E04A25090981F00301 ISSUE DATE: December 2, 2025 FCC ID: 2ADSY-BCS1H Prepared for Healbe Corporation 541 Jefferson Avenue Suite 100, Redwood City, CA 94063 Prepared by Guangdong Global Testing Technology Co., Ltd. Room 101-105, 203-210, Building 1, No.2, Keji 8 Road, Songshan Lake Park, Dongguan city, Guangdong, People’s Republic of China, 523808 This report is based on a single evaluation of the submitted sample(s) of the above mentioned product, it does not imply an assessment of the production of the products. This report shall not be reproduced, except in full, without the written approval of Guangdong Global Testing Technology Co., Ltd. REPORT NO.: E04A25090981F00301 Page 2 of 60 TRF No.: 04-E001-0B Global Testing , Great Quality. Revision History Rev. Issue Date Revisions Revised By V0 December 2, 2025 Initial Issue REPORT NO.: E04A25090981F00301 Page 3 of 60 TRF No.: 04-E001-0B Global Testing , Great Quality. Summary of Test Results Test Item Limit/Requirement Result Antenna Requirement FCC Part 15.203/15.247 (c) Pass AC Power Line Conducted Emission FCC Part 15.207 N/A 1 Conducted Output Power FCC Part 15.247 (b)(3) Pass 6dB Bandwidth and 99% Occupied Bandwidth FCC Part 15.247 (a)(2) Pass Power Spectral Density FCC Part 15.247 (e) Pass Conducted Band edge and spurious emission FCC Part 15.247(d) Pass Radiated Band edge and Spurious Emission FCC Part 15.205/15.209 Pass Duty Cycle None; for reporting purposes only. Pass Note: 1. The product is powered by dry batteries. This item is not applicable. *This test report is only published to and used by the applicant, and it is not for evidence purpose in China. *The measurement result for the sample received is <Pass> according to <CFR 47 FCC PART 15 SUBPART C(DTS)> when <Accuracy Method> decision rule is applied. REPORT NO.: E04A25090981F00301 Page 4 of 60 TRF No.: 04-E001-0B Global Testing , Great Quality. CONTENTS 1. ATTESTATION OF TEST RESULTS ..................................................................................... 5 2. TEST METHODOLOGY ......................................................................................................... 6 3. FACILITIES AND ACCREDITATION ..................................................................................... 6 4. CALIBRATION AND UNCERTAINTY ................................................................................... 7 4.1. MEASURING INSTRUMENT CALIBRATION ........................................................... 7 4.2. MEASUREMENT UNCERTAINTY ............................................................................ 7 5. EQUIPMENT UNDER TEST .................................................................................................. 8 5.1. DESCRIPTION OF EUT ........................................................................................... 8 5.2. CHANNEL LIST ........................................................................................................ 8 5.3. MAXIMUM PEAK OUTPUT POWER ........................................................................ 9 5.4. TEST CHANNEL CONFIGURATION ........................................................................ 9 5.5. THE WORSE CASE POWER SETTING PARAMETER ............................................ 9 5.6. DESCRIPTION OF AVAILABLE ANTENNAS ........................................................... 9 5.7. SUPPORT UNITS FOR SYSTEM TEST ................................................................... 9 5.8. SETUP DIAGRAM .................................................................................................. 10 6. MEASURING EQUIPMENT AND SOFTWARE USED......................................................... 11 7. ANTENNA PORT TEST RESULTS ..................................................................................... 13 7.1. Conducted Output Power ........................................................................................ 13 7.2. 6dB Bandwidth and 99% Occupied Bandwidth ....................................................... 14 7.3. Power Spectral Density ........................................................................................... 16 7.4. Conducted Band edge and spurious emission ........................................................ 17 7.5. Duty Cycle .............................................................................................................. 19 8. RADIATED TEST RESULTS ............................................................................................... 20 8.1. Radiated Band edge and Spurious Emission .......................................................... 25 9. ANTENNA REQUIREMENT ................................................................................................ 38 10. TEST DATA - Appendix A ..................................................................................... 39 REPORT NO.: E04A25090981F00301 Page 5 of 60 TRF No.: 04-E001-0B Global Testing , Great Quality. 1. ATTESTATION OF TEST RESULTS Applicant Information Company Name: Healbe Corporation Address: 541 Jefferson Avenue Suite 100, Redwood City, CA 94063 Manufacturer Information Company Name: Zhongshan Kangnuo Electronics Co.,Ltd. Address: 2F, No.9-1, Dongcheng North Road, Xinsheng Village, Xiaolan, Zhongshan, Guangdong, China 528400 EUT Information Product Description: HEALBE Scale Model: BCS1H Series Model: 700A, B6H, B12H, B30H, B40H, B41H, B80H, B90H, BCS2H, B21H, B16H, B92B, B200H, B700H Brand: HEALBE Sample Received Date: November 4, 2025 Sample Status: Normal Sample ID: A25090981 002 Date of Tested: November 4, 2025 to November 20, 2025 APPLICABLE STANDARDS STANDARD TEST RESULTS CFR 47 FCC PART 15 SUBPART C(DT…

Text truncated - open the document above for the full version.

Test Setup Photos

Setup Photographs Radiated Band edge and Spurious Emission

Contact Information

Applicant

Artem Shipitsyn(Mr)
[email protected]Fax: +85253322195

Technical Contact

Guangdong Global Testing Technology Co., Ltd.Shawn Wen
[email protected]

Room 101-105,203-210, Building 1, No.2, Keji 8 Roa · Dongguan, 523808 · China

Test Firm

Guangdong Global Testing Technology Co., Ltd.Shawn Wen
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.80 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from Healbe Corporation

GoBe3 - FCC ID 2ADSYRF07HB3 - Healbe Corporation
2ADSYRF07HB3

GoBe3

Apr 04, 2020

Equipment Class

DTS - Digital Transmission System
Gobe watch - FCC ID 2ADSYRF07HB1 - Healbe Corporation
2ADSYRF07HB1

Gobe watch

Dec 30, 2014

Equipment Class

DTS - Digital Transmission System