FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Healbe Corporation/
  3. 2ADSYRF07HB1

2ADSYRF07HB1Gobe watch

Healbe Corporation
Gobe watch - FCC ID 2ADSYRF07HB1 - Healbe Corporation
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 30, 2014
Application Purpose
Original Equipment
Date of Application
Dec 30, 2014
Equipment Note
Gobe watch
Frequency Range
2402.00000000 - 2480.00000000
Company
Healbe Corporation
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Quick start guide Introduction Congratulations on purchasing your Healbe GoBe™! You’ve taken the first step toward a healthier and happier life. Please read this manual carefully before using your GoBe body manager. Healbe GoBe™ The Original 100% Automatic Body Manager, made hassle-free with FLOW Technology, is a proud brand of Healbe™ Corporation DOWNLOAD THE FREE APP 4 8 9 10 10 10 11 11 11 11 12 General Registration Getting Started App: Menu App: Dashboard App: Energy App: Water App: Heart App: Sleep App: Stress Site Healbe GoBe™ is compatible with iPhones 4s/5/5c/5s, iPad 3/4/air/mini, iPod 5G(iOS 7.0 or later) any Android phones equipped with Bluetooth 4.0 and running Android 4.3 or later. Phones with small screens and tablets are not currently supported. Find more compatible phones on healbe.com. Battery usage GoBe has a [ ]. A full charge will last for about three days of average use. When connected to the charger, the display will indicate battery life. General GoBe Automatic Body Manager Charger Cable 1 2 3 What’s included How to wear GoBe GoBe should fit snugly on your wrist, with the wristband in full contact with your skin. It’s important that GoBe fits properly so the sensors that power Healbe FLOW™ Technology can read your body’s information. Make the most of GoBe One long push turns your GoBe on or off. Before eating, push and hold the button until it vibrates. This increases the accuracy of the automatic calorie intake measurement. GoBe will remind you if you forget to press the button before a meal. NOTE: There may be a time lag before GoBe starts to register calorie intake, as your body digests different foods at different rates. 76 Flow technology Only FLOW Technology measures calorie intake through your skin-by reading the glucose in your cells. Unlike apps and wearable devices that require you to manually log the calories you consume, only GoBe gives you automatic calorie management with FLOW Technology, the patented innovation that combines information from three sensors with an advanced algorithm, giving you a complete picture of your body’s state of internal balance. PRESSURE SENSOR measures blood flow and heart rate IMPEDANCE SENSOR measures fluid level in tissues ACCELEROMETER measures body movement and activity GOBE TIME E-IN/E-OUT PULSE POWER_% LOW BATTERY BT SW UPDATE SW UPDATE ON UPDATE ERROR NO CONTACT SERVICE BYE : Power is on : Device is working properly : Current time : Calories consumed and burned : Your current heart rate : Percentage of battery life remaining : Battery is low : Searching and connecting to your phone via Bluetooth : Software update in progress. Try to maintain Bluetooth and Internet connection during update. : Updated software installed. Device will restart. : Couldn’t complete software update. Check your internet connection. : Device lost contact with your skin. Please adjust wristband. : Something went wrong. Contact customer service at ( ) : Device is powering down. 3 GoBe display notifications 98 Registration Create a profile to help GoBe provide the most accurate information about your body. Click on each field for tips to help you complete your profile. 1. Your email address is your login. 2. Choose a password. 3. Confirm your password. Getting Started GoBe uses Bluetooth 4.0 (BLE) to connect with your phone. Please be sure that your Bluetooth is turned on: ● Turn Bluetooth to “on” under Settings → Bluetooth. ● Open the GoBe app and login. The app will search for Bluetooth devices. ● Choose Healbe GoBe from the list. ● Each GoBe can be paired to up to five devices. GoBe uses PIN-code authorization to make sure your data is secure. When you pair your GoBe with your phone for the first time, use the PIN 000000 (six zeroes). We recommend changing your PIN by clicking the wristband icon in the GoBe app. You can choose to have your app remember your PIN. Follow the instructions in the app to download the GoBe software before your first use. The app will notify you when updates to the software are available. 1110 App: Dashboard This is the main screen of the app, which displays all the whole-body health parameters GoBe measures. All icons show your current status. For more detailed information, click or swipe the parameter you’re interested in. App: Menu Profile This is your basic health and personal information. You can edit any field at any time. Wristband Click the wristband icon to see information about your GoBe device, including: ● Wristband fit ● Battery life ● Bluetooth connection ● Software update ● PIN-code change ● Help App: Energy The Energy screen shows calories burned and consumed. The left column is calories consumed, and the right is calories burned. In the graph, the upper section is calories consumed, and the lower section is calories burned. Swipe the graph to see a time of day. Swipe the table to see data from a different day. App: Water Track how much water you drink during the day. Full glasses show the water you’ve consumed. Empty glasses show how much you still need to drink. Click on a glass to mark it as full. Swipe the main frame to see data from a different day. App: Heart Monitor your heart rate and blood pressure around the clock. Press the “measurement” button to take a blood pressure measurement. Your result will be added to the table at the end of the page. App: Sleep Track length and quality of sleep. The first line shows when you’re sleeping. The second line shows REM phases. GoBe also monitors health risks while you’re sleeping. Use the Smart Alarm to wake up feeling refreshed! Just tell GoBe when you have to wake up, and it will wake you during the optimal sleep phase closest to that time. App: Stress Monitor your stress level. GoBe rates your stress on a scale of 1-5, based on blood pressure and other health data. 1312 Website After logging in, you will be able to see all data that’s been sent from your GoBe body manager to your app. Data that hasn’t yet been downloaded to the app will not be displ…

Text truncated - open the document above for the full version.

Cover Letter(s)

Vicky Yuan

External Photos

1 Photographs - EUT Constructional Details Test model No.: GoBe 1.0

ID Label/Location Info

FCC ID: 2ADSYRF07HB1 3.5 mm 5.0 mm

Internal Photos

1 Photographs - EUT Constructional Details Test model No.: GoBe 1.0

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. No. 1 W orkshop, M-10, Middle section, Science & Technology Park, Nanshan District, Shenzhen, Guangdong, China 518057 Telephone: +86 (0) 755 2601 2053 Fax: +86 (0) 755 2671 0594 Email: [email protected] Report No.: SZEM141200691102 Page: 1 of 6 Authorized Signature: Jack Zhang EMC Laboratory Manager The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS International Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by SGS International Electrical Approvals in writing. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. All test results in this report can be traceable to National or International Standards. “This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.” 1 Cover page SAR Evaluation Report Application No: SZEM1412006911CR Applicant: Healbe Corporation Manufacturer: Healbe Corporation Product Name: Gobe watch Model No.(EUT): GoBe 1.0 Trade Mark: Healbe FCC ID: 2ADSYRF07HB1 Standards: 47 CFR Part 1.1307(2013) 47 CFR Part 2.1093 (2013) KDB447498D01 General RF Exposure Guidance v05 Date of Receipt: 2014-12-15 Date of Test: 2014-12-17 to 2014-12-22 Date of Issue: 2014-12-26 Test Result : PASS* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Report No.: SZEM141200691102 Page: 2 of 6 “This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.” 2 Version Revision Record Version Chapter Date Modifier Remark 00 2014-12-26 Original Authorized for issue by: Tested By 2014-12-22 (Eric Fu) /Project Engineer Date Prepared By 2014-12-26 (Linlin Lv) /Clerk Date Checked By 2014-12-30 (Kevin Feng) /Reviewer Date SGS-CSTC Standards Technical Services Co., Ltd. Report No.: SZEM141200691102 Page: 3 of 6 “This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.” 3 Contents Page 1 COVER PAGE .........................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

SGS-CSTC Standards Technical Services Ltd. No. 1 W orkshop, M-10, Middle section, Science & Technology Park, Nanshan District, Shenzhen, Guangdong, China 518057 Telephone: +86 (0) 755 2601 2053 Fax: +86 (0) 755 2671 0594 Email: [email protected] Report No.: SZEM141200691101 Page: 1 of 49 Authorized Signature: Jack Zhang EMC Laboratory Manager The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS International Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by SGS International Electrical Approvals in writing. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. All test results in this report can be traceable to National or International Standards. “This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.” 1 Cover page FCC REPORT Application No: SZEM1412006911CR Applicant: Healbe Corporation Manufacturer: Healbe Corporation Product Name: Gobe watch Model No.(EUT): GoBe 1.0 Trade Mark: Healbe FCC ID: 2ADSYRF07HB1 Standards: 47 CFR Part 15, Subpart C (2013) Date of Receipt: 2014-12-15 Date of Test: 2014-12-17 to 2014-12-22 Date of Issue: 2014-12-26 Test Result: PASS * * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Ltd. Report No.: SZEM141200691101 Page: 2 of 49 “This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.” 2 Version Revision Record Version Chapter Date Modifier Remark 00 2014-12-26 Original Authorized for issue by: Tested By 2014-12-22 (Eric Fu) /Project Engineer Date Prepared By 2014-12-26 (Linlin Lv) /Clerk Date Checked By 2014-12-30 (Kevin Feng) /Reviewer Date SGS-CSTC Standards Technical Services Ltd. Report No.: SZEM141200691101 Page: 3 of 49 “This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.” 3 Test Summary Test Item Test Requirement Test method Result Antenna Requirement 47 CFR Part 15, Subpart C Section 15.203/15.247 (c) ANSI C63.10 2009 PASS AC Power Line Conducted Emission 47 CFR Part 15, Subpart C Section 15.207 ANSI C63…

Text truncated - open the document above for the full version.

Test Setup Photos

1 Photographs - EUT Test Setup Test model No.: GoBe 1.0 1.1 Conducted Emission 1.2 Radiated Spurious Emission

Contact Information

Applicant

Artem Shipitsyn(Mr)
[email protected]+85253322195Fax: +85253322195

Test Firm

SGS-CSTC Standards Technical Services Co.,Ltd.June Zhang
[email protected]8675525328598Fax: 86075526710594

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz3.80 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted.

Other Applications from Healbe Corporation

HEALBE Scale - FCC ID 2ADSY-BCS1H - Healbe Corporation
2ADSY-BCS1H

HEALBE Scale

Dec 11, 2025

Equipment Class

DTS - Digital Transmission System
GoBe3 - FCC ID 2ADSYRF07HB3 - Healbe Corporation
2ADSYRF07HB3

GoBe3

Apr 04, 2020

Equipment Class

DTS - Digital Transmission System