2ADZF-D0002915 - 923 MHz Transceiver

i1 SensorTech, Inc. D.B.A Athlete Intelligence
915 - 923 MHz Transceiver - FCC ID 2ADZF-D0002 - i1 SensorTech, Inc. D.B.A Athlete Intelligence
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jun 14, 2022
Application Purpose
Original Equipment
Date of Application
Jun 12, 2022
Equipment Note
915 - 923 MHz Transceiver
Frequency Range
915.00000000 - 923.00000000
Company
i1 SensorTech, Inc. D.B.A Athlete Intelligence
Country
United States

Documents & Files

Select a file to view

Users Manual

β†—

Cover Letter(s)

β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

RF Exposure Info

β†—

Test Report

β†—

Test Setup Photos

β†—
β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Team User Manual 1 | P a g e [email protected] | (425)372-7811 IMPROVE PERFORMANCE | IMPROVE SAFETY About Athlete Intelligence Athlete Intelligence is a sports data analytics company specializing in head-impact monitoring and performance tracking solutions. Using the Athlete Intelligence Platform with our innovative wearables, Coaching and sideline professionals can gain access to data they have never had access to previously to: Improve Athlete Technique Manage Head-Impact Exposure Reduce the Risk of Injury Stop Guessing, Start Monitoring Since 2015, Athlete Intelligence has been on the field with some of sports top teams and most prestigious research institutions globally to provide on-field head-impact monitoring. At Athlete Intelligence, we strive each day to elevate athletic performance while helping to keep athletes safe. With a main goal of building better athletes, we accomplish this by providing Coachable Moments allowing staff to improve technique, manage head-impact exposure, and reduce the risk of injury. Using integrated technology, athletic staff, has an objective view of what happens during games and practices to better analyze and adjust player behavior. It is recommended to read the user manual thoroughly prior to use. If you need any assistance at all, please contact our Customer Support Team directly at (425)372-7811 or by e-mailing [email protected] Product Warning: No mouthguard sensor or helmet sensor can prevent, diagnose, or identify concussions. If concussion symptoms become apparent in an athlete, please remove the athlete from play. Athlete Intelligence analytics platform is designed to empower decision making of sideline professionals, not replace it. FCC Notice: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. To ensure compliance with FCC RF exposure for the SLR+, a minimum 20cm separation distance from users and bystanders should be maintained when both transmitters are transmitting simultaneously. Changes or modifications not expressly approved by the manufacturer could void the user’s ability to operate the equipment. 2 | P a g e [email protected] | (425)372-7811 IMPROVE PERFORMANCE | IMPROVE SAFETY Table of Contents About Athlete Intelligence Page 1 Product Warning Page 1 FCC Notice Page 1 System Components Page 4 Daily Best Practices Page 5 Product Specifications Page 5 Initial Set-Up Completed System Tasks by Athlete Intelligence Page 6 Administrator Set-Up Tasks 1. Complete Admin Account Set-Up Page 6 2. Confirm Access to Web Platform Page 7 3. Create Your Team(s) Page 7-9 4. Pre-Set Practice and Game Sessions Page 9 5. Create Additional Team User Profiles Page 10-11 6. Verify Team Roster Page 12-13 7. Set-Up Automated Reports Page 14 8. Install Sideline Manager Computer Application Page 15 9. Download AI Team Mobile App Page 15 Testing System Connectivity Page 16 Placing Clips in Helmets Page 17-25 Daily On-Field Operations Page 26 About the Web Platform Page 27 Athlete Intelligence Web Platform Icons Page 28 Administrative Page Page 29 Team Settings Page 30 Player Comparison Reports Page 31 Roster Management Page 32 Edit Player Page 33 Dashboard Reports Page 34 Device Status Page 35 3 | P a g e [email protected] | (425)372-7811 IMPROVE PERFORMANCE | IMPROVE SAFETY Table of Contents (continued) Gameday Live Feed Page 36 About the AI TEAM Mobile App Page 37 Mobile App Home Screen Icons Page 38 Player Status Screen Page 39 Today’s Impacts Page 40 Frequently Asked Questions Page 41 4 | P a g e [email protected] | (425)372-7811 IMPROVE PERFORMANCE | IMPROVE SAFETY System Components 1. CUE+ Helmet Sensor 2. CUE+ Sensor Mounting Clip 3. Sideline Receiver (SLR+) 4. Bulk Charging Board 5. Jersey Stickers 6. Helmet Velcro 7. Clip Velcro 8. iOS or Android Mobile Phone (Not Included) AI Web Platform The AI Web Platform is our secure cloud platform used for account, team, and player management. All player impact data and historic analytics are also stored in the Web Platform, which is accessible from any computer. Use the Web Platform during Live Mode or to view reports and trends post practice or game at any time. AI TEAM Mobile Application The AI Team mobile application is your live stream of impacts during use and where you receive notifications. 5 | P a g e [email protected] | (425)372-7811 IMPROVE PERFORMANCE | IMPROVE SAFETY Daily Best Practices To ensure the highest level of data collection, we suggest the following best practices are followed for each practice and game day when the CUE+ helmet sensors. It is recommended to use the system in Live Mode. CUE+ Product Specifications Weight 0.6 oz Impact Memory Storage 2,000 Impacts Transmission Range 180 Yards (540 Ft) Live Data Streaming (915 Mhz) Charging Method 30 Unit Bulk Charging Board Battery Life 24 hours in Active Mode Impact Monitoring Location, Quantity, Severity Mobile Accessibility iOS, Android. Apple Watch Impact Notifications Uninterrupted, Real-Time From the field, confirm Wi-Fi connection and connectivity to the CUE+. Make sure SLM, SLR, and devices remain connected when on the field. If status is green, your system is set-up and ready to begin a session. When the practice or game begins, select, start session from the Home screen in the mobile application (if sessions are not pre- scheduled). Impacts will display when in session. Once the practice or game has ended, select, end session (if sessions have not been pre-scheduled). This will close the window for displayable impacts. Reports and analytics can now be reviewed in the Web Platform. Make sure your CUE+ are in the charging board and charging when not in use. Plug in your SLR into your windows computer and use the Device Status p…

Text truncated - open the document above for the full version.

Cover Letter(s)

i1 SensorTech, Inc. 7 33 7 th Ave. Suite 215 Kirkland, WA 980 33 Request for Confidentiality Date: 6/21/2021 Subject: Confidentiality Request for: FCC ID: 2ADZF-D0002 Pursuant to FCC 47 CFR 0.457(d) and 0.459, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested D Short Term οΏ½ Permanent D Short Term D Short Term D Permanent * 1 D Short Term οΏ½ Permanent D Short Term D Permanent D Short Term D Permanent D Short Term οΏ½ Permanent D Short Term D Short Term D Permanent * 3 Exhibit Block Diagrams External Photos Internal Photos Operation Description/Theory of Operation Parts List & Placement/SOM Tune-Up Procedure Schematics Test Setup Photos User's Manual i 1 SensorTech, Inc. has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of _Q 2 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ACB in the event information regarding the product or the product is made available to the public before the requested period has expired. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, By: Andrew Golden (Print name) 1 The asterisked items(*) require further information to be provided to ACB before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 and the specific Document link for DO I found at: https://apps.fcc.gov/oetd;kdb/forms/FTSScarchResultPage.cfm?switch = P&id = ,41731 and review section II, 3) regarding specific information that must accompany these requests. 2 -Please refer to http://acbcert.com/documcnts/misc-docs/Mcmo-Short-Term-Vs-Standard-Confidentiality.pdf for complete details. - Must be signed by applicant contact given for applicant on the FCC site, or by the authoriZi: '. d agent if an appropriate authorized agtnt letter has been provided. Letters should be placed on appropriate letterhead.

External Photos

Cue+ Top External Photo RGB LED Indication Cue+ Bottom External Photo

ID Label/Location Info

Cue+ ID Label & Location Photo

Internal Photos

Cue+ Top Internal Photo Custom Stamped Element Antenna Silicon Labs SoC with RF transmitter Cue+ Top Internal Photo Cue+ Bottom Internal Photo Custom Stamped Element Antenna

RF Exposure Info

Β© 2022 RF Exposure Lab, LLC This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. 802 N. Twin Oaks Valley Road, Suite 105 β€’ San Marcos, CA 92069 β€’ U.S.A. TEL (760) 471-2100 β€’ FAX (760) 471-2121 http://www.rfexposurelab.com CERTIFICATE OF COMPLIANCE SAR EVALUATION i1 SensorTech, Inc. Dates of Test: March 23, 2022 733 7 th Avenue, Suite 215 Test Report Number: SAR.20220308 Kirkland, WA 98033 Revision B This wireless mobile and/or portable device has been shown to be compliant for localized specific absorption rate (SAR) for uncontrolled environment/general exposure limits specified in ANSI/IEEE Std. C95.1-1992 and had been tested in accordance with the measurement procedures specified in IEEE 1528-2013 and IEC 62209-1528:2010 (See test report). I attest to the accuracy of the data. All measurements were performed by myself or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. RF Exposure Lab, LLC certifies that no party to this application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Jay M. Moulton Vice President Testing Cert. # 2387.01 FCC ID: 2ADZF-D0002 Model(s): Cue+ Test Sample: Engineering Unit Same as Production Serial Number: AA8-33D Equipment Type: Wireless Athletic Monitor Classification: Portable Transmitter Next to Head and Body TX Frequency Range: 915 – 923 MHz Frequency Tolerance: Β± 1.5 ppm Maximum RF Output: 900 MHz – 19.0 dBm Conducted Signal Modulation: FM Antenna Type: Internal Antenna Application Type: Certification FCC Rule Parts: Part 2, 15 KDB Test Methodology: KDB 447498 D01 v07 Maximum SAR Value: 1.13 W/kg Reported Separation Distance: 0 mm Report Number: SAR.20220311 Β© 2022 RF Exposure Lab, LLC Page 2 of 56 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. Table of Contents 1. Introduction ........................................................................................................................ 4 SAR Definition [5] ................................................................................................................... 5 2. SAR Measurement Setup ................................................................................................... 6 Robotic System ...................................................................................................................... 6 System Hardware ................................................................................................................... 6 System Electronics ................................................................................................................. 7 Probe Measurement System .................................................................................................. 7 3. Probe and Dipole Calibration .............................................................................................15 4. Phantom & Simulating Tissue Specifications .....................................................................16 Head & Body Simulating Mixture Characterization ................................................................16 5. ANSI/IEEE C95.1 – 1992 RF Exposure Limits [2] ..............................................................17 Uncontrolled Environment .....................................................................................................17 Controlled Environment .........................................................................................................17 6. Measurement Uncertainty .................................................................................................18 7. System Validation..............................................................................................................19 Tissue Verification .................................................................................................................19 Test System Verification ........................................................................................................19 8. SAR Test Data Summary ..................................................................................................20 Procedures Used To Establish Test Signal ...........................................................................20 Device Test Condition ...........................................................................................................20 SAR Data Summary – 900 MHz ............................................................................................23 9. Test Equipment List ...........................................................................................................24 10. Conclusion ....................................................................................................................25 11. References ....................................................................................................................26 Appendix A – System Validation Plots and Data .......................................................................27 Appendix B – SAR Test Data Plots ...........................................................................................30 A ppendix C – SAR Test Setup Photos ......................................................................................32 Appendix D – Probe Calibration Data Sheets ............................................................................36 Appendix E – Dipole Calibration Data Sheets ...........................................................................47 Appendix F – Phantom Calibration Data Sheets .......................................................................54 Appendix G – Validation Summary ...............................…

Text truncated - open the document above for the full version.

Test Report

Engineering Solutions & Electromagnetic Compatibility Services 360 Herndon Pkwy | Suite 1400 | Herndon | Virginia 20170 Phone: 703.689.0368 | Fax: 703.689.2056 | www.rheintech.com FCC Part 15.247 Certification Report Test Lab: Rhein Tech Laboratories, Inc. Phone: 703-689-0368 360 Herndon Parkway Fax: 703-689-2056 Suite 1400 www.rheintech.com Herndon, VA 20170 Applicant: i1 SensorTech, Inc. Phone: 425-372-7811 733 7th Avenue Suite 215 Kirkland, WA 98033 USA FCC ID 2ADZF-D0002 Test Report Date April 8, 2022 Platform N/A RTL Work Order Number 2021076 Model Cue+ RTL Quote Number QRTL21-076A American National Standard Institute ANSI C63.10-2013: American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices FCC Classification DTS – Digital Transmission System FCC Rule Part(s) Part 15.247: Operation within the bands 902-928 MHz, 2400-2483.5 MHz and 5725-5850 MHz (10-01-2020) Frequency Range (MHz) Output Power (W)* Frequency Tolerance Emission Designator 915 – 923 0.074 N/A 1M66F1D *Power is conducted peak I , the undersigned, hereby declare that the equipment tested and referenced in this report conforms to the identified standard(s) as described in this test report. No modifications were made to the equipment during testing in order to achieve compliance with these standards. Furthermore, there was no deviation from, additions to, or exclusions from, the applicable parts of FCC Part 2, FCC Part 15, and ANSI C63.10. S ignature: D ate: April 8, 2022 T yped/Printed Name: Desmond A. Fraser Po sition: President This report may not be reproduced, except in full, without the written approval of Rhein Tech Laboratories, Inc. and i1 SensorTech, Inc. The test results relate only to the item(s) tested. Replaces R1.3. These tests are accredited and meet the requirements of ISO/IEC 17025 as verified by ANAB. Refer to certificate and scope of accreditation AT-1445. Rhein Tech Laboratories, Inc. Client: i1 SensorTech, Inc. 360 Herndon Parkway Model: Cue+ Suite 1400 Standard: 15.247 Herndon, VA 20170 FCC ID: 2ADZF-D0002 http://www.rheintech.com Report #: 2021076 Page 2 of 39 Table of Contents 1 General Information .................................................................................................................................. 5 1.1 Scope ................................................................................................................................................... 5 1.2 Description of EUT ............................................................................................................................... 5 1.3 Test Facility .......................................................................................................................................... 5 1.4 Related Submittal(s)/Grant(s) .............................................................................................................. 5 1.5 Modifications ........................................................................................................................................ 5 2 Test Information ........................................................................................................................................ 6 2.1 Description of Test Modes ................................................................................................................... 6 2.2 Exercising the EUT .............................................................................................................................. 6 2.3 Test Result Summary ........................................................................................................................... 6 2.4 Test System Details ............................................................................................................................. 6 2.5 Configuration of Tested System ........................................................................................................... 7 3 Maximum Conducted Output Power – FCC 15.247(b)(3) ........................................................................ 8 3.1 Power Output Test Procedure ............................................................................................................. 8 3.2 Power Output Test Data ....................................................................................................................... 8 4 Band Edge Compliance of RF Conducted Emissions – FCC 15.247(d) ................................................ 11 4.1 Band Edge Test Procedure ................................................................................................................ 11 4.2 Test Results ....................................................................................................................................... 12 5 Antenna Conducted Spurious Emissions – FCC 15.247(d) ................................................................... 14 5.1 Antenna Conducted Spurious Emissions Test Procedures ............................................................... 14 5.2 Antenna Conducted Spurious Emissions Test Results ..................................................................... 15 6 6 dB Bandwidth – FCC 15.247(a)(2) ...................................................................................................... 17 6.1 6 dB Bandwidth Test Procedure ........................................................................................................ 17 6.2 Bandwidth Test Results ..................................................................................................................... 17 7 Power Spectral Density – FCC 15.247(e) .............................................................................................. 20 7.1 Power Spectral Density Test Procedure ............................................................................................ 20 7.2 Power Spectral Density Test Data ..............................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Rhein Tech Laboratories, Inc. Client: i1 SensorTech, Inc. 360 Herndon Parkway Model: Cue+ Suite 1400 Standard: 15.247 Herndon, VA 20170 FCC ID: 2ADZF-D0002 http://www.rheintech.com Report #: 2021076 Page 33 of 39 Appendix B: Test Photographs Photograph 1: Radiated Emissions (Below 1 GHz) Front View Rhein Tech Laboratories, Inc. Client: i1 SensorTech, Inc. 360 Herndon Parkway Model: Cue+ Suite 1400 Standard: 15.247 Herndon, VA 20170 FCC ID: 2ADZF-D0002 http://www.rheintech.com Report #: 2021076 Page 34 of 39 Photograph 2: Radiated Emissions (Below 1 GHz) Back View Rhein Tech Laboratories, Inc. Client: i1 SensorTech, Inc. 360 Herndon Parkway Model: Cue+ Suite 1400 Standard: 15.247 Herndon, VA 20170 FCC ID: 2ADZF-D0002 http://www.rheintech.com Report #: 2021076 Page 35 of 39 Photograph 3: Radiated Emissions (Above 1 GHz) Front View Rhein Tech Laboratories, Inc. Client: i1 SensorTech, Inc. 360 Herndon Parkway Model: Cue+ Suite 1400 Standard: 15.247 Herndon, VA 20170 FCC ID: 2ADZF-D0002 http://www.rheintech.com Report #: 2021076 Page 36 of 39 Photograph 4: Radiated Emissions (Above 1 GHz) Back View Rhein Tech Laboratories, Inc. Client: i1 SensorTech, Inc. 360 Herndon Parkway Model: Cue+ Suite 1400 Standard: 15.247 Herndon, VA 20170 FCC ID: 2ADZF-D0002 http://www.rheintech.com Report #: 2021076 Page 37 of 39 Photograph 5: Conducted Antenna Port Rhein Tech Laboratories, Inc. Client: i1 SensorTech, Inc. 360 Herndon Parkway Model: Cue+ Suite 1400 Standard: 15.247 Herndon, VA 20170 FCC ID: 2ADZF-D0002 http://www.rheintech.com Report #: 2021076 Page 38 of 39 Photograph 6: AC Conducted Front View Rhein Tech Laboratories, Inc. Client: i1 SensorTech, Inc. 360 Herndon Parkway Model: Cue+ Suite 1400 Standard: 15.247 Herndon, VA 20170 FCC ID: 2ADZF-D0002 http://www.rheintech.com Report #: 2021076 Page 39 of 39 Photograph 7: AC Conducted Back View

Test Setup Photos

Report Number: SAR.20220311 Β© 2022 RF Exposure Lab, LLC Page 32 of 56 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. Appendix C – SAR Test Setup Photos Test Position Back 0 mm Gap Report Number: SAR.20220311 Β© 2022 RF Exposure Lab, LLC Page 33 of 56 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. Test Position Front 0 mm Gap Report Number: SAR.20220311 Β© 2022 RF Exposure Lab, LLC Page 34 of 56 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. Front of Device Report Number: SAR.20220311 Β© 2022 RF Exposure Lab, LLC Page 35 of 56 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. Back of Device

Contact Information

Applicant

Andrew Golden(VP Operations)
[email protected]4253727804Fax: 4253727811

Test Firm

Rhein Tech Laboratories, Inc.Richard McMurray
[email protected]703-689-0368Fax: 703-689-2056

Technical Specifications

#Rule PartsFrequency RangePower Output
115C915 MHz - 923 MHz74.00 mW
Confidentiality
Long Term
Grant Notes
Output Power is conducted. The antenna(s) used for this transmitter must not transmit simultaneously with any other co-located antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. End-users must be provided with transmitter installation and operating conditions for satisfying RF exposure compliance. The highest reported SAR value is 1.13 W/kg.

Other Applications from i1 SensorTech, Inc. D.B.A Athlete Intelligence

915 - 923 MHz Transceiver - FCC ID 2ADZF-S0002 - i1 SensorTech, Inc. D.B.A Athlete Intelligence
2ADZF-S0002

915 - 923 MHz Transceiver

Jul 17, 2022

Equipment Class

DTS - Digital Transmission System
S0001 - FCC ID 2ADZF-S0001 - i1 SensorTech, Inc. D.B.A Athlete Intelligence
2ADZF-S0001

S0001

Feb 22, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
D0001 - FCC ID 2ADZF-D0001 - i1 SensorTech, Inc. D.B.A Athlete Intelligence
2ADZF-D0001

D0001

Feb 22, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter