FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. GSM GLOBE.COM INC/
  3. 2AEJAS1MADRID

2AEJAS1MADRIDMOBILE PHONE

GSM GLOBE.COM INC
MOBILE PHONE - FCC ID 2AEJAS1MADRID - GSM GLOBE.COM INC
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Feb 17, 2020
Application Purpose
Original Equipment
Date of Application
Feb 17, 2020
Equipment Note
MOBILE PHONE
Frequency Range
2402.00000000 - 2480.00000000
Company
GSM GLOBE.COM INC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

Report No: CCISE191114701V01 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1911147 No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 29 of 44 8 EUT Constructional Details Report No: CCISE191114701V01 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1911147 No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 30 of 44 Report No: CCISE191114701V01 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1911147 No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 31 of 44 Report No: CCISE191114701V01 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1911147 No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 32 of 44 Report No: CCISE191114701V01 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1911147 No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 33 of 44

Internal Photos

Report No: CCISE191114701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1911147 No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 32 of 42 Report No: CCISE191114701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1911147 No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 33 of 42 Report No: CCISE191114701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1911147 No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 34 of 42 Report No: CCISE191114701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1911147 No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 35 of 42 Report No: CCISE191114701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1911147 No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 36 of 42 Report No: CCISE191114701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1911147 No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 37 of 42 Report No: CCISE191114701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1911147 No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 38 of 42 Report No: CCISE191114701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1911147 No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 39 of 42 Report No: CCISE191114701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1911147 No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 40 of 42 Report No: CCISE191114701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1911147 No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 41 of 42 Report No: CCISE191114701 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1911147 No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 42 of 42 ------End of report------

RF Exposure Info

Shenzhen Zhongjian Nanfang Testing Co.,Ltd. Report No: CCISE1911148-V01 Authorized Signature: Bruce Zhang Laboratory Manager This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 1 Cover Page FCC SAR REPORT Applicant: GSM GLOBE.COM INC Address of Applicant: 134 N.E 1 Street,Miami,FL 33132 Equipment Under Test (EUT) Product Name: MOBILE PHONE Model No.: S1 Madrid Trade mark: GOL FCC ID: 2AEJAS1MADRID Applicable standards: FCC 47 CFR Part 2.1093 Date of Test: 03 Dec., 2019 ~ 10 Dec., 2019 Test Result: Maximum Reported1-g SAR (W/kg) Head: 1.176 Body: 1.136 Report No: CCISE1911148-V01 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1911148 No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road, Bao’an District, Shenzhen, Guangdong,China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 2 of 83 2 Version Version No. Date Description 00 11 Dec., 2019 Original 01 23 Dec., 2019 1. Updated page 1, 6. Prepared by: Date: 23 Dec., 2019 Report Clerk Reviewed by: Date: 23 Dec., 2019 Project Engineer Report No: CCISE1911148-V01 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1911148 No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road, Bao’an District, Shenzhen, Guangdong,China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366, E-mail: [email protected] Page 3 of 83 3 Contents 1 COVER PAGE ....................................................................................................................................................... 1 2 VERSION ............................................................................................................................................................... 2 3 CONTENTS ........................................................................................................................................................... 3 4 SAR RESULTS SUMMARY ................................................................................................................................. 5 5 GENERAL INFORMATION .................................................................................................................................. 6 5.1 CLIENT INFORMATION ..................................................................................................................................................................... 6 5.2 GENERAL DESCRIPTION OF EUT ................................................................................................................................................... 6 5.3 MAXIMUM RF OUTPUT POWER ...................................................................................................................................................... 7 5.4 ENVIRONMENT OF TEST SITE ......................................................................................................................................................... 7 5.5 TEST LOCATION ............................................................................................................................................................................. 7 6 INTRODUCTION ................................................................................................................................................... 8 6.1 INTRODUCTION ............................................................................................................................................................................... 8 6.2 SAR DEFINITION ............................................................................................................................................................................ 8 7 RF EXPOSURE LIMITS ....................................................................................................................................... 9 7.1 UNCONTROLLED ENVIRONMENT ..................................................................................................................................................... 9 7.2 CONTROLLED ENVIRONMENT ......................................................................................................................................................... 9 7.3 RF EXPOSURE LIMITS .................................................................................................................................................................... 9 8 SAR MEASUREMENT SYSTEM ....................................................................................................................... 10 8.1 E-FIELD PROBE............................................................................................................................................................................ 11 8.2 DATA ACQUISITION ELECTRONICS (DAE) .................................................................................................................................... 11 8.3 ROBOT .......................................................................................…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Zhongjian Nanfang Testing Co., Ltd. Report No: CCISE191114702V01 Authorized Signature: Bruce Zhang Laboratory Manager This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 1 Cover Page FCC REPORT (Bluetooth) Applicant: GSM GLOBE.COM INC Address of Applicant: 8212 NW 30th Terrace, Doral, FL 33122 Equipment Under Test (EUT) Product Name: MOBILE PHONE Model No.: S1 Madrid Trade mark: GOL FCC ID: 2AEJAS1MADRID Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of sample receipt: 26 Nov., 2019 Date of Test: 27 Nov., to 04 Dec., 2019 Date of report issued: 24 Dec., 2019 Test Result: PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No: CCISE191114702V01 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1911147 No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 2 of 54 2 Version Version No. Date Description 00 05 Dec., 2019 Original 01 24 Dec., 2019 Update page 10, 11, 48, 50, 51 Tested by: Date: 24 Dec., 2019 Test Engineer Reviewed by: Date: 24 Dec., 2019 Project Engineer Report No: CCISE191114702V01 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1911147 No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 3 of 54 3 Contents Page 1 COVER PAGE ......................................................................................................................................................... 1 2 VERSION ................................................................................................................................................................. 2 3 CONTENTS ............................................................................................................................................................. 3 4 TEST SUMMARY .................................................................................................................................................... 4 5 GENERAL INFORMATION .................................................................................................................................... 5 5.1 CLIENT INFORMATION ....................................................................................................................................... 5 5.2 GENERAL DESCRIPTION OF E.U.T. ................................................................................................................... 5 5.3 TEST ENVIRONMENT AND TEST MODE ................................................................................................................ 6 5.4 DESCRIPTION OF SUPPORT UNITS .................................................................................................................... 6 5.5 MEASUREMENT UNCERTAINTY .......................................................................................................................... 6 5.6 ADDITIONS TO, DEVIATIONS, OR EXCLUSIONS FROM THE METHOD ....................................................................... 6 5.7 LABORATORY FACILITY ..................................................................................................................................... 6 5.8 LABORATORY LOCATION ................................................................................................................................... 6 5.9 TEST INSTRUMENTS LIST .................................................................................................................................. 7 6 TEST RESULTS AND MEASUREMENT DATA ................................................................................................... 8 6.1 ANTENNA REQUIREMENT .................................................................................................................................. 8 6.2 CONDUCTED EMISSIONS .................................................................................................................................. 9 6.3 CONDUCTED OUTPUT POWER ........................................................................................................................ 12 6.4 20DB OCCUPY BANDWIDTH ............................................................................................................................ 15 6.5 CARRIER FREQUENCIES SEPARATION ............................................................................................................. 18 6.6 HOPPING CHANNEL NUMBER .......................................................................................................................... 22 6.7 DWELL TIME .................................................................................................................................................. 24 6.8 PSEUDORANDOM FREQUENCY HOPPING SEQUENCE .............................…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No: CCISE191114702 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1911147 No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 53 of 54 7 Test Setup Photo Radiated Spurious Emission Below 1GHz Above 1GHz Report No: CCISE191114702 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE1911147 No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366 Page 54 of 54 Conducted Emission 8 EUT Constructional Details Reference to the test report No.: CCISE191114701 ------End of report------

Test Setup Photos

EUT Photos (Model: S1 Madrid) EUT Antenna Locations SAR Test Setup Photos Head Right Cheek Right Tilted Left Cheek Left Tilted Body Front side (10mm) Back side(10mm)

Contact Information

Applicant

Zubair Panjwani(Director)
[email protected]7862476086Fax: 9544739444

Technical Contact

GSM GLOBE.COM INC
[email protected]

United States

Test Firm

JianYan Testing Group Shenzhen Co., Ltd.Bruce Zhang
[email protected]+86 (0) 755 23118282

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz6.87 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power.

Other Applications from GSM GLOBE.COM INC

MOBILE PHONE - FCC ID 2AEJARAYOGO - GSM GLOBE.COM INC
2AEJARAYOGO

MOBILE PHONE

Sep 10, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Mobile Phone - FCC ID 2AEJA-ATLAS - GSM GLOBE.COM INC
2AEJA-ATLAS

Mobile Phone

Jul 20, 2023

Equipment Class

DTS - Digital Transmission System
MOBILE PHONE - FCC ID 2AEJARAYOX1PLUS - GSM GLOBE.COM INC
2AEJARAYOX1PLUS

MOBILE PHONE

May 13, 2023

Equipment Class

DTS - Digital Transmission System
Mobile Phone - FCC ID 2AEJATITAN - GSM GLOBE.COM INC
2AEJATITAN

Mobile Phone

May 03, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2G Feature phone - FCC ID 2AEJAR4 - GSM GLOBE.COM INC
2AEJAR4

2G Feature phone

Apr 16, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter