Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Federal Communication Commission Interference Statement • This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communica- tions. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. FCC Caution: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Non-modification Statement: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC SDOC SUPPLIER’S DECLARATION OF CONFORMITY Guangzhou Shirui Electronics Co., Ltd. hereby declares that this equipment is in compliance with the FCC Part 15 Subpart B. The declaration of conformity may be consulted in the support section of our Web site www.maxhub.com. ISED Statement: This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numé rique de classe B est conforme à la norme canadienne ICES-003. IC Radiation Exposure Statement for Canada This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: 1.This device may not cause interference. 2.This device must accept any interference, including interference that may cause undesired operation of the device. L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : 1.L’appareil ne doit pas produire de brouillage; 2.L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. This equipment complies with FCC and RSS 102 radiation exposure limits set forth for an uncontrolled environment. End user must follow the specific operating instructions for satisfying RF exposure compliance. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Ce matériel est conforme aux limites d'exposition aux radiations FCC et RSS 102 fixées pour un environnement non contrôlé. L'utilisateur final doit suivre les instructions opérationnelles spécifiques pour satisfaire à la conformité à l'exposition RF.Cet émetteur ne doit pas être co-localisé ni fonctionné conjointement avec aucune autre antenne ou émetteur. This device meets the U.S. FCC’s and ISED Canada’s requirements for exposure to radio waves and is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy. For satisfying RF exposure compliance requirements, body-worn operations are assembly to belt-clips, holsters or similar accessories that have no metallic com ponent in the assembly and must provide at least 5 mm separation between the device, including its antenna, and the use’s body. Cet appareil est conforme aux exigences de la FCC des États Unis et d’ISED Canada en matière d’exposition aux ondes radio et a été conçu et fabriqué de manière à ne pas dépasser les limites d’émission pour l’exposition à l’énergie de radiofréquence (RF). Afin de satisfaire aux exigences de conformité relatives à l’exposition RF, le fonctionnement porté sur le corps est limité à l’utilisation d’accessoires tels que des pinces de ceinture, des étuis ou des accessoires similaires ne contenant aucun composant métallique et devant assurer une distance de séparation minimale de 5 mm entre l’appareil, y compris son antenne, et le corps de l’utilisateur.
1 | P a g e Appendix A Photo Sample Front view Rear view 2 | P a g e Antenna location map 3 | P a g e Test Position Front Surface (5mm) Back Surface (5mm) Left Edge (5mm) Right Edge (5mm) Bottom Edge (5mm) / /
Appendix II Setup Photographs RADIATED RF MEASUREMENT SETUP (ABOVE 1 GHz) MEASUREMENT POSITION MEASUREMENT POSITION (X axis) MEASUREMENT POSITION (Y axis) MEASUREMENT POSITION (Z axis) RADIATED RF MEASUREMENT SETUP (30MHz~1GHz) RADIATED RF MEASUREMENT SETUP (Below 30MHz) POWERLINE CONDUCTED EMISSIONS MEASUREMENT SETUP
REPORT NO.: 4792261336-1-RF-1 Page 224 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11.5. APPENDIX E: MAXIMUM POWER SPECTRAL DENSITY 11.5.1. Test Result Test Mode Antenna Frequency[MHz] Power [dBm/MHz] Limit [dBm/MHz] EIRP [dBm/MHz] Limit [dBm/MHz] Verdict 11A Ant1 5180 2.97 ≤11.00 7.95 ≤10.00 PASS Ant2 5180 5.18 ≤11.00 8.19 ≤10.00 PASS Ant1 5200 2.90 ≤11.00 7.88 ≤10.00 PASS Ant2 5200 6.11 ≤11.00 9.12 ≤10.00 PASS Ant1 5240 3.88 ≤11.00 8.86 ≤10.00 PASS Ant2 5240 5.36 ≤11.00 8.37 ≤10.00 PASS Ant1 5260 3.33 ≤11.00 8.60 --- PASS Ant2 5260 5.03 ≤11.00 8.52 --- PASS Ant1 5280 4.23 ≤11.00 9.50 --- PASS Ant2 5280 5.25 ≤11.00 8.74 --- PASS Ant1 5320 4.09 ≤11.00 9.36 --- PASS Ant2 5320 4.29 ≤11.00 7.78 --- PASS Ant1 5500 3.30 ≤10.34 9.96 --- PASS Ant2 5500 4.51 ≤11.00 9.04 --- PASS Ant1 5580 4.10 ≤10.34 10.76 --- PASS Ant2 5580 5.43 ≤11.00 9.96 --- PASS Ant1 5700 3.76 ≤10.34 10.42 --- PASS Ant2 5700 4.40 ≤11.00 8.93 --- PASS Ant1 5720_UNII-2C 3.24 ≤10.34 9.90 --- PASS Ant2 5720_UNII-2C 3.62 ≤11.00 8.15 --- PASS Ant1 5720_UNII-3 -1.22 ≤29.00 5.78 --- PASS Ant2 5720_UNII-3 -0.75 ≤30.00 4.67 --- PASS Ant1 5745 2.50 ≤29.00 9.50 --- PASS Ant2 5745 1.83 ≤30.00 7.25 --- PASS Ant1 5785 3.00 ≤29.00 10.00 --- PASS Ant2 5785 2.15 ≤30.00 7.57 --- PASS Ant1 5825 1.73 ≤29.00 8.73 --- PASS Ant2 5825 1.74 ≤30.00 7.16 --- PASS 11N20MIMO Ant1 5180 -2.50 ≤11.00 2.48 ≤10.00 PASS Ant2 5180 -2.21 ≤11.00 0.8 ≤10.00 PASS total 5180 0.66 ≤11.00 7.72 ≤10.00 PASS Ant1 5200 -2.89 ≤11.00 2.09 ≤10.00 PASS Ant2 5200 -1.89 ≤11.00 1.12 ≤10.00 PASS total 5200 0.65 ≤11.00 7.71 ≤10.00 PASS Ant1 5240 -3.06 ≤11.00 1.92 ≤10.00 PASS Ant2 5240 -2.65 ≤11.00 0.36 ≤10.00 PASS total 5240 0.16 ≤11.00 7.22 ≤10.00 PASS Ant1 5260 2.63 ≤11.00 7.9 --- PASS Ant2 5260 3.24 ≤11.00 6.73 --- PASS total 5260 5.96 ≤11.00 13.81 --- PASS Ant1 5280 2.88 ≤11.00 8.15 --- PASS Ant2 5280 3.91 ≤11.00 7.4 --- PASS total 5280 6.44 ≤11.00 14.29 --- PASS Ant1 5320 3.26 ≤11.00 8.53 --- PASS Ant2 5320 3.34 ≤11.00 6.83 --- PASS total 5320 6.31 ≤11.00 14.16 --- PASS Ant1 5500 3.97 ≤10.34 10.63 --- PASS Ant2 5500 4.59 ≤11.00 9.12 --- PASS total 5500 7.30 ≤11.00 15.97 --- PASS Ant1 5580 2.21 ≤10.34 8.87 --- PASS Ant2 5580 3.38 ≤11.00 7.91 --- PASS total 5580 5.84 ≤11.00 14.51 --- PASS Ant1 5700 4.18 ≤10.34 10.84 --- PASS Ant2 5700 4.31 ≤11.00 8.84 --- PASS total 5700 7.26 ≤11.00 15.93 --- PASS REPORT NO.: 4792261336-1-RF-1 Page 225 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Ant1 5720_UNII-2C 3.05 ≤10.34 9.71 --- PASS Ant2 5720_UNII-2C 2.98 ≤11.00 7.51 --- PASS total 5720_UNII-2C 6.03 ≤11.00 14.7 --- PASS Ant1 5720_UNII-3 -1.12 ≤29.00 5.88 --- PASS Ant2 5720_UNII-3 -1.20 ≤30.00 4.22 --- PASS total 5720_UNII-3 1.85 ≤30.00 11.11 --- PASS Ant1 5745 1.30 ≤29.00 8.3 --- PASS Ant2 5745 0.10 ≤30.00 5.52 --- PASS total 5745 3.75 ≤30.00 13.01 --- PASS Ant1 5785 0.40 ≤29.00 7.4 --- PASS Ant2 5785 0.63 ≤30.00 6.05 --- PASS total 5785 3.53 ≤30.00 12.79 --- PASS Ant1 5825 -0.36 ≤29.00 6.64 --- PASS Ant2 5825 0.30 ≤30.00 5.72 --- PASS total 5825 2.99 ≤30.00 12.25 --- PASS 11N40MIMO Ant1 5190 -2.34 ≤11.00 2.64 ≤10.00 PASS Ant2 5190 0.06 ≤11.00 3.07 ≤10.00 PASS total 5190 2.03 ≤11.00 9.09 ≤10.00 PASS Ant1 5230 -1.09 ≤11.00 3.89 ≤10.00 PASS Ant2 5230 -1.10 ≤11.00 1.91 ≤10.00 PASS total 5230 1.92 ≤11.00 8.98 ≤10.00 PASS Ant1 5270 -0.07 ≤11.00 5.2 --- PASS Ant2 5270 1.74 ≤11.00 5.23 --- PASS total 5270 3.94 ≤11.00 11.79 --- PASS Ant1 5310 0.42 ≤11.00 5.69 --- PASS Ant2 5310 1.03 ≤11.00 4.52 --- PASS total 5310 3.75 ≤11.00 11.6 --- PASS Ant1 5510 -0.86 ≤10.34 5.8 --- PASS Ant2 5510 1.37 ≤11.00 5.9 --- PASS total 5510 3.41 ≤11.00 12.08 --- PASS Ant1 5550 -0.18 ≤10.34 6.48 --- PASS Ant2 5550 1.74 ≤11.00 6.27 --- PASS total 5550 3.90 ≤11.00 12.57 --- PASS Ant1 5670 0.23 ≤10.34 6.89 --- PASS Ant2 5670 0.66 ≤11.00 5.19 --- PASS total 5670 3.46 ≤11.00 12.13 --- PASS Ant1 5710_UNII-2C -0.63 ≤10.34 6.03 --- PASS Ant2 5710_UNII-2C -0.10 ≤11.00 4.43 --- PASS total 5710_UNII-2C 2.65 ≤11.00 11.32 --- PASS Ant1 5710_UNII-3 -6.49 ≤29.00 0.51 --- PASS Ant2 5710_UNII-3 -5.01 ≤30.00 0.41 --- PASS total 5710_UNII-3 -2.68 ≤30.00 6.58 --- PASS Ant1 5755 0.68 ≤29.00 7.68 --- PASS Ant2 5755 2.18 ≤30.00 7.6 --- PASS total 5755 4.50 ≤30.00 13.76 --- PASS Ant1 5795 -0.39 ≤29.00 6.61 --- PASS Ant2 5795 1.71 ≤30.00 7.13 --- PASS total 5795 3.80 ≤30.00 13.06 --- PASS 11AC80MIMO Ant1 5210 -6.01 ≤11.00 -1.03 ≤10.00 PASS Ant2 5210 -2.20 ≤11.00 0.81 ≤10.00 PASS total 5210 -0.69 ≤11.00 6.37 ≤10.00 PASS Ant1 5290 -3.64 ≤11.00 1.63 --- PASS Ant2 5290 -1.01 ≤11.00 2.48 --- PASS total 5290 0.88 ≤11.00 8.73 --- PASS Ant1 5530 -3.96 ≤10.34 2.7 --- PASS Ant2 5530 -1.48 ≤11.00 3.05 --- PASS total 5530 0.46 ≤11.00 9.13 --- PASS Ant1 5610 -4.22 ≤10.34 2.44 --- PASS Ant2 5610 -2.48 ≤11.00 2.05 --- PASS total 5610 -0.25 ≤11.00 8.42 --- PASS REPORT NO.: 4792261336-1-RF-1 Page 226 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Ant1 5690_UNII-2C -4.59 ≤10.34 2.07 --- PASS Ant2 5690_UNII-2C -3.96 ≤11.00 0.57 --- PASS total 5690_UNII-2C -1.25 ≤11.00 7.42 --- PASS Ant1 5690_UNII-3 -12.02 ≤29.00 -5.02 --- PASS Ant2 5690_UNII-3 -9.61 ≤30.00 -4.19 --- PASS total 5690_UNII-3 -7.64 ≤30.00 1.62 --- PASS Ant1 5775 -4.46 ≤29.00 2.54 --- PASS Ant2 5775 -0.91 ≤30.00 4.51 --- PASS total 5775 0.68 ≤30.00 9.94 --- PASS Note:1.The Result and Limit Unit is dBm/500 kHz in the band 5.725−5.85 GHz. 2.The Duty Cycle Factor and RBW Factor is compensated in…
Text truncated - open the document above for the full version.
REPORT NO.: 4792261336-1-RF-1 Page 180 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11A_Ant2_5280 11A_Ant1_5320 11A_Ant2_5320 REPORT NO.: 4792261336-1-RF-1 Page 181 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11A_Ant1_5500 11A_Ant2_5500 11A_Ant1_5580 REPORT NO.: 4792261336-1-RF-1 Page 182 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11A_Ant2_5580 11A_Ant1_5700 11A_Ant2_5700 REPORT NO.: 4792261336-1-RF-1 Page 183 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11A_Ant1_5720 11A_Ant2_5720 11A_Ant1_5745 REPORT NO.: 4792261336-1-RF-1 Page 184 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11A_Ant2_5745 11A_Ant1_5785 11A_Ant2_5785 REPORT NO.: 4792261336-1-RF-1 Page 185 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11A_Ant1_5825 11A_Ant2_5825 11N20MIMO_Ant1_5180 REPORT NO.: 4792261336-1-RF-1 Page 186 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11N20MIMO_Ant2_5180 11N20MIMO_Ant1_5200 11N20MIMO_Ant2_5200 REPORT NO.: 4792261336-1-RF-1 Page 187 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11N20MIMO_Ant1_5240 11N20MIMO_Ant2_5240 11N20MIMO_Ant1_5260 REPORT NO.: 4792261336-1-RF-1 Page 188 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11N20MIMO_Ant2_5260 11N20MIMO_Ant1_5280 11N20MIMO_Ant2_5280 REPORT NO.: 4792261336-1-RF-1 Page 189 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11N20MIMO_Ant1_5320 11N20MIMO_Ant2_5320 11N20MIMO_Ant1_5500 REPORT NO.: 4792261336-1-RF-1 Page 190 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11N20MIMO_Ant2_5500 11N20MIMO_Ant1_5580 11N20MIMO_Ant2_5580 REPORT NO.: 4792261336-1-RF-1 Page 191 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11N20MIMO_Ant1_5700 11N20MIMO_Ant2_5700 11N20MIMO_Ant1_5720 REPORT NO.: 4792261336-1-RF-1 Page 192 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11N20MIMO_Ant2_5720 11N20MIMO_Ant1_5745 11N20MIMO_Ant2_5745 REPORT NO.: 4792261336-1-RF-1 Page 193 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11N20MIMO_Ant1_5785 11N20MIMO_Ant2_5785 11N20MIMO_Ant1_5825 REPORT NO.: 4792261336-1-RF-1 Page 194 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11N20MIMO_Ant2_5825 11N40MIMO_Ant1_5190 11N40MIMO_Ant2_5190 REPORT NO.: 4792261336-1-RF-1 Page 195 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11N40MIMO_Ant1_5230 11N40MIMO_Ant2_5230 11N40MIMO_Ant1_5270 REPORT NO.: 4792261336-1-RF-1 Page 196 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 11N40MIMO_Ant2_5270 11N40MIMO_Ant1_5310 11N40MIMO_Ant2_5310 REPORT NO.: 4792261336-1-RF-1 Page 197 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shal…
Text truncated - open the document above for the full version.
REPORT NO.: 4792261336-1-RF-1 Page 112 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. TX Radiated Test Result Project Information Test Mode 802.11n HT Frequency 5280 Bandwidth 20M Polarity V Environment Temp: 23.5°C; Humi:49% Test Date 2026-06-27 Note \ Engineer Leslie Xie Test Graph PEAK Data List NO . Frequency [MHz] Reading [dBμV] Level [dBμV/m] Factor [dB/m] Limit [dBμV/m] Margin [dB] Detector Polarity Verdic t 1 9135.57 50.78 39.76 -11.02 74.00 34.24 PK Vertical PASS 2 10561.28 60.19 50.93 -9.26 68.20 17.27 PK Vertical PASS 3 11606.80 50.31 40.44 -9.87 74.00 33.56 PK Vertical PASS 4 13972.99 52.11 40.59 -11.52 68.20 27.61 PK Vertical PASS 5 15843.92 55.24 46.29 -8.95 74.00 27.71 PK Vertical PASS 6 17039.52 49.16 41.63 -7.53 68.20 26.57 PK Vertical PASS Note:(1)Level=Reading+Factor (2)Margin=Limit-Level REPORT NO.: 4792261336-1-RF-1 Page 113 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. TX Radiated Test Result Project Information Test Mode 802.11n HT Frequency 5320 Bandwidth 20M Polarity H Environment Temp: 23.5°C; Humi:49% Test Date 2026-06-27 Note \ Engineer Leslie Xie Test Graph PEAK Data List NO . Frequency [MHz] Reading [dBμV] Level [dBμV/m] Factor [dB/m] Limit [dBμV/m] Margin [dB] Detector Polarity Verdic t 1 9135.57 51.27 40.25 -11.02 74.00 33.75 PK Horizontal PASS 2 9935.97 51.01 40.81 -10.20 68.20 27.39 PK Horizontal PASS 3 10636.32 57.42 48.38 -9.04 74.00 25.62 PK Horizontal PASS 4 13972.99 51.91 40.39 -11.52 68.20 27.81 PK Horizontal PASS 5 15918.96 49.66 41.08 -8.58 74.00 32.92 PK Horizontal PASS 6 17059.53 49.37 41.88 -7.49 68.20 26.32 PK Horizontal PASS Note:(1)Level=Reading+Factor (2)Margin=Limit-Level REPORT NO.: 4792261336-1-RF-1 Page 114 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. TX Radiated Test Result Project Information Test Mode 802.11n HT Frequency 5320 Bandwidth 20M Polarity V Environment Temp: 23.5°C; Humi:49% Test Date 2026-06-27 Note \ Engineer Leslie Xie Test Graph PEAK Data List NO . Frequency [MHz] Reading [dBμV] Level [dBμV/m] Factor [dB/m] Limit [dBμV/m] Margin [dB] Detector Polarity Verdic t 1 9135.57 51.02 40.00 -11.02 74.00 34.00 PK Vertical PASS 2 9996.00 50.49 40.78 -9.71 68.20 27.42 PK Vertical PASS 3 10636.32 64.18 55.14 -9.04 74.00 18.86 PK Vertical PASS 4 13737.87 54.79 43.37 -11.42 68.20 24.83 PK Vertical PASS 5 15968.98 54.28 45.93 -8.35 74.00 28.07 PK Vertical PASS 6 17024.51 49.61 42.06 -7.55 68.20 26.14 PK Vertical PASS AVG Data List NO. Frequency [MHz] Factor [dB/m] AV Reading [dBμV/m] AV Value [dBμV/m] AV Limit [dBμV/m] AV Margin [dB] Polarity Verdict 1 10636.32 -9.04 53.08 44.04 54.00 9.96 Vertical PASS Note:(1)Level=Reading+Factor (2)Margin=Limit-Level REPORT NO.: 4792261336-1-RF-1 Page 115 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. TX Radiated Test Result Project Information Test Mode 802.11n HT Frequency 5500 Bandwidth 20M Polarity H Environment Temp: 23.5°C; Humi:49% Test Date 2026-06-27 Note \ Engineer Leslie Xie Test Graph PEAK Data List NO . Frequency [MHz] Reading [dBμV] Level [dBμV/m] Factor [dB/m] Limit [dBμV/m] Margin [dB] Detector Polarity Verdic t 1 9020.51 51.54 39.87 -11.67 74.00 34.13 PK Horizontal PASS 2 9940.97 52.05 41.89 -10.16 68.20 26.31 PK Horizontal PASS 3 11001.50 53.04 44.64 -8.40 74.00 29.36 PK Horizontal PASS 4 13602.80 53.93 42.18 -11.75 68.20 26.02 PK Horizontal PASS 5 16009.00 50.15 41.92 -8.23 74.00 32.08 PK Horizontal PASS 6 17194.60 50.22 42.96 -7.26 68.20 25.24 PK Horizontal PASS Note:(1)Level=Reading+Factor (2)Margin=Limit-Level REPORT NO.: 4792261336-1-RF-1 Page 116 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. TX Radiated Test Result Project Information Test Mode 802.11n HT Frequency 5500 Bandwidth 20M Polarity V Environment Temp: 23.5°C; Humi:49% Test Date 2026-06-27 Note \ Engineer Leslie Xie Test Graph PEAK Data List NO . Frequency [MHz] Reading [dBμV] Level [dBμV/m] Factor [dB/m] Limit [dBμV/m] Margin [dB] Detector Polarity Verdic t 1 9110.56 50.54 39.37 -11.17 74.00 34.63 PK Vertical PASS 2 10031.02 51.60 41.76 -9.84 68.20 26.44 PK Vertical PASS 3 10996.50 59.41 51.00 -8.41 74.00 23.00 PK Vertical PASS 4 13737.87 52.63 41.21 -11.42 68.20 26.99 PK Vertical PASS 5 15573.79 50.64 41.76 -8.88 74.00 32.24 PK Vertical PASS 6 16889.44 49.69 41.93 -7.76 68.20 26.27 PK Vertical PASS Note:(1)Level=Reading+Factor (2)Margin=Limit-Level REPORT NO.: 4792261336-1-RF-1 Page 117 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. TX Radiated Test Result Project Information Test Mode 802.11n HT Frequency 5580 Bandwidth 20M Polarity H Environment Temp: 23.5°C; Humi:49% Test Date 2026-06-27 Note \ Engineer Leslie Xie Test Graph PEAK Data List NO . Frequency [MHz] Reading [dBμV] Level [dBμV/m] Factor [dB/m] Limit [dBμV/m] Margin [dB] Detector Polarity Verdic t 1 9140.57 50.62 39.62 -11.00 74.00 34.38 PK Horiz…
Text truncated - open the document above for the full version.
The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. FCC 47 CFR PART 15 SUBPART E ISED RSS-247 Issue 4 TEST REPORT For Wireless Screen Sharing Dongle MODEL NUMBER for FCC: WT15M, WT******* (*:0~9,A~Z,or Blank) HVIN for IC: WT12P REPORT NUMBER: 4792261336-1-RF-1 ISSUE DATE: July 16, 2026 FCC ID: 2AFG6-WT12P IC: 22166-WT12P Prepared for Guangzhou Shirui Electronics Co., Ltd 192 Kezhu Road, Scientech Park, Guangzhou Economic & Technology Development District, Guangzhou, Guangdong, China Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT NO.: 4792261336-1-RF-1 Page 2 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Revision History Rev. Issue Date Revisions Revised By V0 July 16, 2026 Initial Issue REPORT NO.: 4792261336-1-RF-1 Page 3 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Summary of Test Results Test Item Clause Limit/Requirement Result ON TIME AND DUTY CYCLE ANSI C63.10-2020, Clause 12.2 None; for reporting purposes only. Pass (NOTE 2) 6dB AND 26dB EMISSION BANDWIDTH AND 99% OCCUPIED BANDWIDTH KDB 789033 D02 v02r01 Section C.1 FCC Part 15.407 (a)/(e), RSS-247 Issue 4, Clause 7.3.5.2 RSS-Gen Clause 6.7 Pass CONDUCTED OUTPUT POWER KDB 789033 D02 v02r01 Section E.3.a (Method PM)/KDB 789033 D02 v02r01 Section E.3.a (Method PM) Section E.2.d (Method SA-2) FCC 15.407 (a) RSS-247 Clause 7.3 Pass POWER SPECTRAL DENSITY KDB 789033 D02 v02r01 Section F FCC 15.407 (a) RSS-247 Clause 7.3 Pass AC Power Line Conducted Emission ANSI C63.10-2020, Clause 6.2. FCC 15.207 RSS-GEN Clause 8.8 Radiated Emissions and Band Edge Measurement KDB 789033 D02 v02r01 Section G.3, G.4, G.5, and G.6 FCC 15.407 (b) FCC 15.209 FCC 15.205 RSS-247 Clause 7.3 RSS-GEN Clause 8.9 Pass FREQUENCY STABILITY ANSI C63.10-2020,Clause 6.8 FCC Part 15.407 (g) RSS-Gen Clause 6.11 Pass Dynamic Frequency Selection (Slave) KDB 905462 D03 UNII Clients Without Radar Detection New Rules v01r02 FCC Part 15.407 (h), RSS-247 Issue 4 Clause 7.3.6 Pass Dynamic Frequency Selection (Master) KDB 905462 D02 UNII DFS Compliance Procedures New Rules v02 FCC Part 15.407 (h), RSS-247 Issue 4 Clause 7.3.6 N/A Antenna Requirement N/A FCC 47 CFR Part 15.203/ 15.407(a)(1) (2), RSS-Gen Issue 5, Clause 6.8 N/A Note: 1. N/A: In this whole report not applicable. 2. 1.For ISED, this report is also performed according to ANSI C63.10-2020 + Cor.1-2023 + C63.10a-2024 + Errata to C63.10a-2024 standards. 2.For FCC, this report is also performed according to ANSI C63.10-2020 + Cor.1-2023. *This test report is only published to and used by the applicant, and it is not for evidence purpose in China. *The measurement result for the sample received is <Pass> according to <FCC 47 CFR PART 15 SUBPART E ISED RSS-247 Issue 4> when <Simple Acceptance> decision rule is applied. Decision rule for statement of conformity: The measurement uncertainty is not taken into account for statement of conformity. REPORT NO.: 4792261336-1-RF-1 Page 4 of 264 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. CONTENTS 1. ATTESTATION OF TEST RESULTS ..................................................................................... 6 2. TEST METHODOLOGY ......................................................................................................... 7 3. FACILITIES AND ACCREDITATION ..................................................................................... 7 4. CALIBRATION AND UNCERTAINTY ................................................................................... 8 4.1. MEASURING INSTRUMENT CALIBRATION ........................................................... 8 4.2. MEASUREMENT UNCERTAINTY ............................................................................ 8 5. EQUIPMENT UNDER TEST .................................................................................................. 9 5.1. DESCRIPTION OF EUT ........................................................................................... 9 5.2. CHANNEL LIST ........................................................................................................ 9 5.3. MAXIMUM POWER ................................................................................................ 11 5.4. TEST CHANNEL CONFIGURATION ...................................................................... 12 5.5. THE WORSE CASE POWER SETTING PARAMETER .......................................... 13 5.6. WORSE CASE CONFIGURATIONS ....................................................................... 15 5.7. DESCRIPTION OF AVAILABLE ANTENNAS ......................................................... 16 5.8. SUPPORT UNITS FOR SYSTEM TEST ................................................................. 18 6. MEASURING EQUIPMENT AND SOFTWARE USED......................................................... 19 7. ANTENNA PORT TEST RESULTS ....................................................................................…
Text truncated - open the document above for the full version.
TESTREPORT 测试报告 Applicant:GuangzhouShizheninformationTechnologyCo.,LTD 申请人:广州视臻信息科技有限公司 Address:Room508,No.192KezhuRoad,GuangzhouEconomicand TechnologicalDevelopmentZone 地址:广州市经济技术开发区科珠路192号508房 EquipmentType:PCBAntenna 设备类型:PCB天线 ModelName:WT12S 型号名称:WT12S BrandName:N/A 品牌名称:不适用 TestStandard:ANSI/IEEEStd149-1979 试验标准:ANSI/IEEEStd149-1979 TestDate:Jan.25,2024 测试日期:2024-01-25 DateofIssue:Jan.30,2024 签发日期:2024-01-30 ISSUEDBY:GuangzhouJingcetestingTechnologyCo.,LTD 发证单位:广州璟测检测技术有限公司 Tested by: 测试:黄 Approved by: Checked by: 审核: 批准: ReportNo.:JCF240125111-001 1 / 41 Revisi…
Text truncated - open the document above for the full version.
3722 Illinois Avenue Saint Charles, IL 60174 · Illinois, 60174 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15E | 5.18 GHz - 5.24 GHz | 44.00 mW |
| 2 | 15E | 5.26 GHz - 5.32 GHz | 60.00 mW |
| 3 | 15E | 5.50 GHz - 5.72 GHz | 59.00 mW |
| 4 | 15E | 5.75 GHz - 5.83 GHz | 128.00 mW |
Wireless PTZ Camera
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Portable Capture Host
Equipment Class
NII - Unlicensed National Information Infrastructure TXWifi Module
Equipment Class
6XD - 15E 6 GHz Low Power Indoor ClientBluetooth Dongle
Equipment Class
DTS - Digital Transmission SystemAI Stylus
Equipment Class
DTS - Digital Transmission System