FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Noke Inc/
  3. 2AFRJ-100

2AFRJ-100Noke Gatewa

Noke Inc
Noke Gatewa - FCC ID 2AFRJ-100 - Noke Inc
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
May 18, 2021
Application Purpose
Original Equipment
Date of Application
May 18, 2021
Equipment Note
Noke Gatewa
Frequency Range
2402.00000000 - 2480.00000000
Company
Noke Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

A: Use the Nokē Smart-Entry App to scan QR code on the device and add device to the Smart-Entry system B: Using web portal, be sure electronic keys are sent to gateways C:Use the app to unlock other device after it has been synced to the system. The QR sticker can now we removed UNLOCK ADDING Nokē TO SITE SUPPORT If you need support, please call 1(833) 257-0240

Cover Letter(s)

SCS-F019:ConfidentialityRequestLetterPage 1 of 3 Rev7.0 775MontagueExpressway Milpitas,CA95035 Tel:408-526-1188 Fax:408-526-1088 Email:[email protected] Website:https://www.cps.bureauveritas.com/ Confidentiality RequestLetter ReasonforAmendment(current/obsolete) RevisionHistory ApprovedDate FromTo InitialRelease(obsolete)1.01.0Nov-14-2006 AddingCFR2.459(obsolete)1.02.0August–11-2008 Updatedcompanytemplate&Addedtext box(obsolete) 2.03.0Jan-31-2012 AddedICconfidentialityletterform (obsolete) 3.04.0March-26-2015 CorrectionstoSTCform.Addedreference toKDB(obsolete) 4.05.0Nov-19-2015 Updatedcompanylogo(current)5.06.0Jun-26-2019 UpdatedReferencesandContactInfo6.07.0Aug-30-2020 SCS-F019:ConfidentialityRequestLetterPage 2 of 3 Rev7.0 NokeInc (2021-04-30) To: FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046-1609 Cc: BureauVeritasConsumerProductsServicesInc. 775MontagueExpressway Milpitas,CA95035 Subject:ConfidentialityRequestforFCCID:2AFRJ-100 PursuanttoCFR47sections0.457and0.459,werespectfullyrequestpermanentconfidentialtreatmentofthe followingExhibitsaccompanyingthisapplicationbeheldconfidential: TypeofConfidentialityRequestedExhibit ShortTermPermanentBlockDiagram ShortTermExternalPhotos ShortTermPermanent i InternalPhotos ShortTermPermanentOperationalDescription/TheoryofOperation ShortTermPermanentPartsList ShortTermPermanentTune-UpProcedure ShortTermPermanentSchematics ShortTermTestSetupPhotos ShortTermPermanent i User’sManual Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarilyreleasedtothepublic. Thepublicdisclosureofthesematerialsmaybeharmfultotheapplicantandprovideunjustifiedbenefitstoits competitors. PermanentConfidentiality: Theapplicantrequeststheexhibitslistedaboveaspermanentlyconfidentialbepermanentlywithheldfrom publicreviewduetomaterialsthatcontaintradesecretsandproprietaryinformationnotcustomarilyreleasedto thepublic. Short-TermConfidentiality: Toavoidprematurereleaseofsensitiveinformationpriortomarketingorreleaseoftheproducttothepublic,the applicantrequeststhefollowingdocumentscontainedinthiscertificationapplicationbetemporarilywithheld frompublicdisclosureforaninitialperiodof45or180days;orforaspecifieddateofnottoexceed 180daysfromtheGrantDate Theapplicantunderstandsthatdisclosureofthisapplicationandallaccompanyingdocumentationwillnotbe madebeforethedateoftheGrantforthisapplication. SCS-F019:ConfidentialityRequestLetterPage 3 of 3 Rev7.0 Sincerely, DavidGengler CEO NokeInc 2000AshtonBlvd,Ste375Lehi,UT84043,USA i PermanentconfidentialitymayberequestedinaccordancewithFCCKDB726920

ID Label/Location Info

Label: Labellocation:

Internal Photos

BLEANT WIFI+BT ANT

RF Exposure Info

RFEXPOSUREEVALUATION EUTSpecification EUTNokeGateway ModelNumberNokeGateway100 FCCID2AFRJ-100 Antennagain(Max)WIFI/BT:5dBi,BLE:1.1dBi OperationFrequencyWLAN:2.412GHz~2.462GHz BR+EDR:2402-2480MHz BLE:2402-2480MHz InputRatingPOE36-57VDC,2A Max.outputpowerWIFI: 802.11b:15.94dBm 802.11g:14.74dBm 802.11n(HT20):15.15dBm 802.11n(HT40):12.51dBm BR+EDR:3.09dBm(0.002037W) BLE:4.42dBm(0.0028W) TestRequirement: AccordingtoFCC1.1310:Thecriterialistedinthefollowingtableshallbeusedto evaluatetheenvironmentimpactofhumanexposuretoradiofrequency(RF)Radiation asspecifiedin§1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Frequency Range(MHz) ElectricField Strength(V/m) Magnetic Field Strength(A/m) Power Density(mW/cm 2 ) Average Time (A)LimitsforOccupational/ControlExposures 300-1500----F/3006 1500-100000----56 (B)LimitsforGeneralPopulation/UncontrolExposures 300-1500----F/15006 1500-100000----130 11.1Friistransmissionformula:Pd=(Pout*G)\(4*pi*R 2 ) Where Pd=PowerdensityinmW/cm 2 Pout=outputpowertoantennainmW G=Numericgainoftheantennarelativetoisotropicantenna Pi=3.1416 R=distancebetweenobservationpointandcenteroftheradiatorincm PdthelimitofMPE,1mW/cm 2 .Ifweknowthemaximumgainofthendtotalpowerinput totheantenna,throughthecalculation,wewillknowthedistancewheretheMPElimitis reached. 11.2MeasurementResult WIFI: BR+EDR: Mode Channe lFreq. (MHz) Measu red power (dBm) Tune- up power (dBm) Max tune-up power (dBm) Antenn a Gain Numeri c Evaluation result (mW/cm2) Power density Limits (mW/c m2) GFSK24021.171±123.1620.0009971 GFSK24412.723±143.1620.0015801 GFSK24803.093±143.1620.0015801 π/4- DQPSK 2402-2.1-2±1-13.1620.0005001 π/4- DQPSK 24411.161±123.1620.0009971 π/4- DQPSK 24801.261±123.1620.0009971 8DPSK 2402-1.33-1±103.1620.0006291 8DPSK 24410.781±123.1620.0009971 8DPSK 24801.281±123.1620.0009971 BLE: Mode Channe lFreq. (MHz) Measu red power (dBm) Tune- up power (dBm) Max tune-up power (dBm) Antenn a Gain Numeri c Evaluation result (mW/cm2) Power density Limits (mW/c m2) GFSK2402-1.91-2±1-11.2880.0002041 GFSK24404.424±151.2880.0008101 GFSK24804.244±151.2880.0008101 Signature: AlanHe Date:2021-04-30

Test Report

Report No.: EA21040016F01002 1 of 74 TRF No. FCC Part 15.247/A Ver.1.0 ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT INTENTIONAL RADIATOR CERTIFICATION TO FCC PART 15 SUBPART C REQUIREMENT OF Noke Gateway Model No.: Noke Gateway 100 Trademark: FCC ID:2AFRJ-100 Report No.: EA21040016F01002 Issue Date: Apr. 21, 2021 Prepared for Noke Inc 2000 Ashton Blvd, Ste 375 Lehi, UT 84043, USA Prepared by Dong Guan Anci Electronic Technology Co., Ltd. 1-2 Floor, Building A, No.11, Headquarters 2 Road, Songshan, Lake Hi-tech Industrial Development Zone, Dongguan City, evelopment Zone, Dongguan City, Guangdong Pr., China. This report shall not be reproduced, except in full, without the written approval of Dong Guan Anci Electronic Technology Co., Ltd. Report No.: EA21040016F01002 2 of 74 TRF No.: FCC 15.209/A Rev. 1.0 VERIFICATION OF COMPLIANCE Applicant: Noke Inc 2000 Ashton Blvd, Ste 375 Lehi, UT 84043, USA Manufacturer: Noke Inc 2000 Ashton Blvd, Ste 375 Lehi, UT 84043, USA Product Description: Noke Gateway Trade Mark: Model Number: Noke Gateway 100 We hereby certify that: The above equipment was tested by Dong Guan Anci Electronic Technology Co., Ltd.The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.10-2013 and the energy emitted by the sample EUT tested as described in this report is in compliance with conducted and radiated emission limits of FCC Rules Part 15.247(2020). Date of Test : Apr. 05, 2021 to Apr. 20, 2021 Prepared by : Tomas Yang/Supervisor Reviewer & Authorized Signer : Alan He/Manager Report No.: EA21040016F01002 3 of 74 TRF No.: FCC 15.209/A Rev. 1.0 Modified Information Version Summary Revision Date Report No. Ver.1.0 Original Report / EA21040016F01002 Report No.: EA21040016F01002 4 of 74 TRF No.: FCC 15.209/A Rev. 1.0 Table of Contents 1. GENERAL INFORMATION ......................................................................................................... 6 1.1 PRODUCT DESCRIPTION ............................................................................................................................. 6 1.2 TEST METHODOLOGY ................................................................................................................................. 6 1.3 TEST FACILITY ............................................................................................................................................. 7 2. SYSTEM TEST CONFIGURATION............................................................................................... 8 2.1EUT CONFIGURATION ................................................................................................................................. 8 2.2 EUT EXERCISE..................................................................................................................................... 8 2.3 TEST PROCEDURE..................................................................................................................................... 8 2.4CONFIGURATION OF TESTED SYSTEM ........................................................................................................ 9 3. SUMMARY OF TEST RESULTS ................................................................................................. 10 4. DESCRIPTION OF TEST MODES .............................................................................................. 11 5. TEST SYSTEM UNCERTAINTY .................................................................................................. 12 6. CONDUCTED EMISSIONS TEST ............................................................................................... 13 6.1MEASUREMENT PROCEDURE: ................................................................................................................... 13 6.2 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) ......................................................................... 13 6.3MEASUREMENT EQUIPMENT USED: .......................................................................................................... 13 6.4 MEASUREMENT RESULT: .......................................................................................................................... 14 6.5 CONDUCTED MEASUREMENT PHOTOS: ................................................................................................... 17 7. RADIATED EMISSION TEST ....................................................................................................... 18 7.1MEASUREMENT PROCEDURE .................................................................................................................... 18 7.2TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) .......................................................................... 20 7.3 MEASUREMENT EQUIPMENT USED: ......................................................................................................... 21 7.4 RADIATED EMISSION LIMIT ....................................................................................................................... 22 7.5 MEASUREMENT RESULT ......................................................................................................................... 23 7.5 RADIATED MEASUREMENT PHOTOS: ....................................................................................................... 31 8. CHANNEL SEPARATION TEST ................................................................................................. 32 8.1MEASUREMENT PROCEDURE .................................................................................................................... 32 8.2TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) .......................................................................... 32 8.3 MEASUREMENT EQUIPMENT USED: ......................................................................................................... 32 8.4MEASUREMENT RESULTS: ....................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jack Gosling(Director o f Hardware)
[email protected]4352418633Fax: 385-645-4567

Test Firm

DongGuan Anci Electronic Technology Co., Ltd.Kingbo Hu
[email protected]86-769- 8507 5888

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Noke Inc

NokeScreen - FCC ID 2AFRJ-KP2-000001 - Noke Inc
2AFRJ-KP2-000001

NokeScreen

Sep 26, 2022

Equipment Class

DTS - Digital Transmission System
Noke One - FCC ID 2AFRJ-1A - Noke Inc
2AFRJ-1A

Noke One

Jul 12, 2020

Equipment Class

DTS - Digital Transmission System
Noke Key Fob - FCC ID 2AFRJNFAM1 - Noke Inc
2AFRJNFAM1

Noke Key Fob

Nov 04, 2015

Equipment Class

DTS - Digital Transmission System