
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
NSC0620-V01 (if applicable) Slide the radio into the mounting sleeve to secure the radio. With the unit on, long press DISP to display clock time. Press and hold DISP until the hours or minutes begin to flash, then release. Rotate the volume knob to adjust the time. Long press DISP to finish the clock setting. Press RELEASE and pull away from the left side to remove. To re-install, insert right side of faceplate first then push left side to secure. Snap trim ring into place. Gray Gray/Black Quick Start Guide XRM69DBT To download the complete, model-specific manual, please visit www.dualav.com/support/manuals.php or call 1-866-382-5476, 9AM-5PM EST (Monday-Friday). Digital Media Receiver FCC Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limitsfor a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. •Increase the separation between the equipment and receiver. •Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. •Consult the dealer or an experienced radio technician for help. Dual Electronics Corp. Toll Free: 1-866-382-5476 Monday-Friday, 9AM-5PM www.dualav.com ©2020 Dual Electronics Corp. All rights reserved. Limited One-Year Warranty This warranty gives you specific legal rights. You may also have other rights which vary from state to state. Dual Electronics Corp. warrants this product to the original purchaser to be free from defects in material and workmanship for a period of one year from the date of the original purchase. (Note that select marine products carry a 2-year warranty. Please visit www.dualav.com for details.) Dual Electronics Corp. agrees, at our option, during the warranty period, to repair any defect in material or workmanship or to furnish an equal new, renewed or comparable product (whichever is deemed necessary) in exchange without charges, subject to verification of the defector malfunction and proof of the date of purchase. Subsequent replacement products are warranted for the balance of the original warranty period. Who is covered? This warranty is extended to the original retail purchaser for products purchased and used in the U.S.A. What is covered? This warranty covers all defects in material and workmanship in this product. The following are not covered: installation/removal costs, damage resulting from accident, misuse, abuse, neglect, product modification, improper installation, incorrect line voltage, unauthorized repair or failure to follow instructions supplied with the product, or damage occurring during return shipment of the product. What to do? 1. Before you call for service, check the troubleshooting guide in your owner’s manual. A slight adjustment of any custom controls may save you a service call. 2. If you require service during the warranty period, you must carefully pack the product (preferably in the original package) and ship it by prepaid transportation with a copy of the original receipt from the retailer to an authorized service center. 3. Please describe your problem in writing and include your name, a return UPS shipping address (P.O. Box not acceptable), and a daytime phone number with your shipment. 4. For more information and for the location of the nearest authorized service center please contact us toll-free at 1-866-382-5476 or by email at [email protected]. Exclusion of Certain Damages: This warranty is exclusive and in lieu of any and all other warranties, expressed or implied, including without limitation the implied warranties of merchantability and fitness for a particular purpose and any obligation, liability, right, claim or remedy in contract or tort, whether or not arising from the company’s negligence, actual or imputed. No person or representative is authorized to assume for the company any other liability in connection with the sale of this product. In no event shall the company be liable for indirect, incidental or consequential damages. Preparation Pairing Faceplate Removal a New Device To download the complete Owner’s Manual for your radio, please visit www.dualav.com/support/manuals.php. Bluetooth ® Before using a Bluetooth device, it must be paired and connected. Ensure that Bluetooth is activated on your device before beginning the pairing process. The head unit broadcasts the pairing signal constantly when no devices are connected. Complete the pairing sequence from your Bluetooth device. Refer to the owner’s manual for your device for more details. The device name is "Dual Media Player" The Bluetooth passcode is "1234” Streaming Audio Troubleshooting •Press ll to skip to the next available audio track. •Press nn to skip to the previous audio track. •Press l / II to toggle between play and pause during playback. Note: If passcode "1234" does not pair your device to the receiver, use passcode "0000". Note…
Text truncated - open the document above for the full version.
2020/7/20 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID:__2AFXA-XRM69DBT Product Name:AM/FM/USB Receiver____ Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: (List here the documents for which you are seeking confidentiality – for example ...) Schematics Block diagram Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature> NameYiu Sang Li TitleManager CompanyFengShun Peiying Electro-Acoustic Co., Ltd
Model No.: XRM69DBT
ProductName : AM/FM/USBReceiver Model : XRM69DBT FCCID:2AFXA-XRM69DBT
Model No.: XRM69DBT
RF Exposure Evaluation Statement Product Name: AM/FM/USB Receiver Model No.:XRM69DBT FCC ID:2AFXA-XRM69DBT 1.1 RF Exposure Compliance Requirement 1.1.1 Standard Requirement According to KDB447498D01 General RF Exposure Guidance v06 Standalone SAR test exclusion considerations Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Exclusion Threshold condition, listed below, is satisfied. 1.1.2 Limits The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation 17 The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion 1.1.3 EUT RF Exposure Operational Mode: EDR (8-DPSK worst case) Channel Maximum Peak Conducted Output Power (dBm) Tune up tolerance (dB) Maximum tune-up Power Calculated value Exclusion threshold (dBm) (mW) 2402MHZ -2.06 ±1 -1.06 0.78 0.24 3.0 2441MHz -3.38 ±1 -2.38 0.58 0.18 2480MHz -3.93 ±1 -2.93 0.51 0.16 Conclusion: the calculated value ≤3.0, SAR is exempted.
Page 1 of81 TEST REPORT Product Name : AM/FM/USB Receiver Brand Mark : DUAL Model No. : XRM69DBT FCC ID : 2AFXA-XRM69DBT Report Number : BLA-EMC-202007-A0701 Date of Sample Receipt : 2020/7/02 Date of Test : 2020/7/02 to 2020/7/20 Date of Issue : 2020/7/20 Test Standard : 47 CFR Part 15, Subpart C 15.247 Test Result : Pass Prepared for: FengShun Peiying Electro-Acoustic Co., Ltd 2nd Floor, Block F, Hongwei Industrial Area,No.6 Liuxian 2 Road, Baocheng 70 Area, Bao'an, Shenzhen City, Guangdong Province, P.R. China Prepared by: BlueAsia of Technical Services(Shenzhen) Co.,Ltd. IOT Test Centre of BlueAsia No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen,China TEL: +86-755-28682673 FAX: +86-755-28682673 Compiled by: Review by: Approved by: Date: 2020/7/20 Report No.: BLA-EMC-202007-A0701 Page 2 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] REPORT REVISE RECORD Version No. Date Description 00 2020/7/20 Original Report No.: BLA-EMC-202007-A0701 Page 3 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755 -28682673 FAX: +86-755-28682673 Email:[email protected] TABLE OF CONTENTS 1 TEST SUMMARY ........................................................................................................................................6 2 GENERAL INFORMATION .........................................................................................................................7 3 GENERAL DESCRIPTION OF E.U.T. .........................................................................................................7 4 TEST ENVIRONMENT ................................................................................................................................8 5 TEST MODE ................................................................................................................................................8 6 MEASUREMENT UNCERTAINTY ..............................................................................................................8 7 DESCRIPTION OF SUPPORT UNIT...........................................................................................................9 8 LABORATORY LOCATION .........................................................................................................................9 9 TEST INSTRUMENTS LIST ..................................................................................................................... 10 ANTENNA REQUIREMENT .............................................................................................................................. 14 CONCLUSION ...................................................................................................................................................................... 14 CONDUCTED SPURIOUS EMISSIONS ........................................................................................................... 15 LIMITS ............................................................................................................................................................................. 15 BLOCK DIAGRAM OF TEST SETUP .................................................................................................................................... 15 TEST DATA ........................................................................................................................................................................ 16 RADIATED SPURIOUS EMISSIONS ............................................................................................................... 17 LIMITS ............................................................................................................................................................................. 17 BLOCK DIAGRAM OF TEST SETUP .................................................................................................................................... 18 PROCEDURE ................................................................................................................................................................... 18 TEST DATA ........................................................................................................................................................................ 20 RADIATED EMISSIONS WHICH FALL IN THE RESTRICTED BANDS ......................................................... 28 LIMITS ............................................................................................................................................................................. 28 BLOCK DIAGRAM OF TEST SETUP .................................................................................................................................... 29 PROCEDURE ................................................................................................................................................................... 29 TEST DATA ........................................................................................................................................................................ 31 Report No.: BLA-EMC-202007-A0701 Page 4 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] CONDUCTED BAND EDGES MEASUREMENT ............................................................................................. 35 LIMITS ........................................................................................................................................................................…
Text truncated - open the document above for the full version.
Report No.: BLA-EMC-202007-A0701 Page 31 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] TEST DATA Remark: During the test, pre-scan the GFSK, π/4 DQPSK, 8-DPSK modulation, and found the 8-DPSK modulation which it is worse case. Lowest channel Peak Report No.: BLA-EMC-202007-A0701 Page 32 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] AVG Report No.: BLA-EMC-202007-A0701 Page 33 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755 -28682673 FAX: +86-755-28682673 Email:[email protected] Peak Highest channel Report No.: BLA-EMC-202007-A0701 Page 34 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] AVG Report No.: BLA-EMC-202007-A0701 Page 35 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] CONDUCTED BAND EDGES MEASUREMENT Test Standard 47 CFR Part 15, Subpart C 15.247 Test Method ANSI C63.10 (2013) Section 7.8.8 & Section 11.13.3.2 Test Mode (Pre-Scan) TX Test Mode (Final Test) TX Tester Jozu Temperature 25°C Humidity 60% LIMITS Limit: In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. If the transmitter complies with the conducted power limits based on the use of RMS averaging over a time interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 dB instead of 20 dB. Attenuation below the general limits specified in §15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in §15.205(a), must also comply with the radiated emission limits specified in §15.209(a) (see §15.205(c)). BLOCK DIAGRAM OF TEST SETUP Report No.: BLA-EMC-202007-A0701 Page 36 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] TEST DATA Pass: Please Refer To Appendix: Appendix1 For Details Report No.: BLA-EMC-202007-A0701 Page 37 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] DWELL TIME Test Standard 47 CFR Part 15, Subpart C 15.247 Test Method ANSI C63.10 (2013) Section 7.8.4 Test Mode (Pre-Scan) TX_non-Hop mode Test Mode (Final Test) TX_non-Hop mode Tester Jozu Temperature 25°C Humidity 60% LIMITS Frequency(MHz) Limit 902-928 0.4S within a 20S period(20dB bandwidth<250kHz) 0.4S within a 10S period(20dB bandwidth≥250kHz) 2400-2483.5 0.4S within a period of 0.4S multiplied by the number of hopping channels 5725-5850 0.4S within a 30S period BLOCK DIAGRAM OF TEST SETUP Report No.: BLA-EMC-202007-A0701 Page 38 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] TEST DATA Pass: Please Refer To Appendix: Appendix1 For Details Report No.: BLA-EMC-202007-A0701 Page 39 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] HOPPING CHANNEL NUMBER Test Standard 47 CFR Part 15, Subpart C 15.247 Test Method ANSI C63.10 (2013) Section 7.8.3 Test Mode (Pre-Scan) TX_non-Hop mode Test Mode (Final Test) TX_non-Hop mode Tester Jozu Temperature 25°C Humidity 60% LIMITS Frequency range(MHz) Number of hopping channels (minimum) 902-928 50 for 20dB bandwidth <250kHz 25 for 20dB bandwidth ≥250kHz 2400-2483.5 15 5725-5850 75 BLOCK DIAGRAM OF TEST SETUP TEST DATA Pass: Please Refer To Appendix: Appendix1 For Details Report No.: BLA-EMC-202007-A0701 Page 40 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] CARRIER FREQUENCIES SEPARATION Test Standard 47 CFR Part 15, Subpart C 15.247 Test Method ANSI C63.10 (2013) Section 7.8.2 Test Mode (Pre-Scan) TX_non-Hop mode Test Mode (Final Test) TX_non-Hop mode Tester Jozu Temperature 25°C Humidity 60% LIMITS Limit: 2/3 of the 20dB bandwidth base on the transmission power is less than 0.125W BLOCK DIAGRAM OF TEST SETUP TEST DATA Pass: Please Refer To Appendix: Appendix1 For Details Report No.: BLA-EMC-202007-A0701 Page 41 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang D…
Text truncated - open the document above for the full version.
Report No.: BLA-EMC-202007-A0701 Page 61 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] Test Graphs DH1_Ant1_Low_2402 DH1_Ant1_High_2480 DH1_Ant1_Low_Hop_2402 DH1_Ant1_High_Hop_2480 Report No.: BLA-EMC-202007-A0701 Page 62 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] 2DH1_Ant1_Low_2402 2DH1_Ant1_High_2480 2DH1_Ant1_Low_Hop_2402 Report No.: BLA-EMC-202007-A0701 Page 63 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] 2DH1_Ant1_High_Hop_2480 3DH1_Ant1_Low_2402 3DH1_Ant1_High_2480 Report No.: BLA-EMC-202007-A0701 Page 64 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] 3DH1_Ant1_Low_Hop_2402 3DH1_Ant1_High_Hop_2480 Report No.: BLA-EMC-202007-A0701 Page 65 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] 10.7 APPENDIX:CONDUCTED SPURIOUSEMISSION Test Result TestMode Antenna Channel FreqRange [MHz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH1 Ant1 2402 Reference -5.29 -5.29 --- PASS 30~1000 30~1000 -64.216 <=-25.291 PASS 1000~26500 1000~26500 -53.416 <=-25.291 PASS 2441 Reference -6.90 -6.90 --- PASS 30~1000 30~1000 -64.838 <=-26.904 PASS 1000~26500 1000~26500 -53.328 <=-26.904 PASS 2480 Reference -7.16 -7.16 --- PASS 30~1000 30~1000 -68.109 <=-27.156 PASS 1000~26500 1000~26500 -53.525 <=-27.156 PASS 2DH1 Ant1 2402 Reference -5.44 -5.44 --- PASS 30~1000 30~1000 -58.396 <=-25.436 PASS 1000~26500 1000~26500 -53.475 <=-25.436 PASS 2441 Reference -6.73 -6.73 --- PASS 30~1000 30~1000 -57.326 <=-26.725 PASS 1000~26500 1000~26500 -52.753 <=-26.725 PASS 2480 Reference -7.31 -7.31 --- PASS 30~1000 30~1000 -58.039 <=-27.305 PASS 1000~26500 1000~26500 -51.558 <=-27.305 PASS 3DH1 Ant1 2402 Reference -5.26 -5.26 --- PASS 30~1000 30~1000 -58.166 <=-25.257 PASS 1000~26500 1000~26500 -52.983 <=-25.257 PASS 2441 Reference -6.55 -6.55 --- PASS 30~1000 30~1000 -58.549 <=-26.546 PASS 1000~26500 1000~26500 -53.342 <=-26.546 PASS 2480 Reference -7.12 -7.12 --- PASS 30~1000 30~1000 -59.526 <=-27.119 PASS 1000~26500 1000~26500 -52.932 <=-27.119 PASS Report No.: BLA-EMC-202007-A0701 Page 66 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] Test Graphs DH1_Ant1_2402_0~Reference DH1_Ant1_2402_30~1000 DH1_Ant1_2402_1000~26500 DH1_Ant1_2441_0~Reference Report No.: BLA-EMC-202007-A0701 Page 67 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] DH1_Ant1_2441_30~1000 DH1_Ant1_2441_1000~26500 DH1_Ant1_2480_0~Reference Report No.: BLA-EMC-202007-A0701 Page 68 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] DH1_Ant1_2480_30~1000 DH1_Ant1_2480_1000~26500 2DH1_Ant1_2402_0~Reference Report No.: BLA-EMC-202007-A0701 Page 69 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] 2DH1_Ant1_2402_30~1000 2DH1_Ant1_2402_1000~26500 2DH1_Ant1_2441_0~Reference Report No.: BLA-EMC-202007-A0701 Page 70 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] 2DH1_Ant1_2441_30~1000 2DH1_Ant1_2441_1000~26500 2DH1_Ant1_2480_0~Reference Report No.: BLA-EMC-202007-A0701 Page 71 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] 2DH1_Ant1_2480_30~1000 2DH1_Ant1_2480_1000~26500 3DH1_Ant1_2402_0~Reference Report No.: BLA-EMC-202007-A0701 Page 72 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] 3DH1_Ant1_2402_30~1000 3DH1_Ant1_2402_1000~26500 3DH1_Ant1_2441_0~Reference Report No.: BLA-EMC-202007-A0701 Page 73 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen, China Telephone: TEL: +86-755-28682673 FAX: +86-755-28682673 Email:[email protected] 3DH1_Ant1_2441_30~1000 3DH1_Ant1_2441_1000~26500 3DH1_Ant1_2480_0~Reference Report No.: BLA-EMC-202007-A0701 Page 74 of81 BlueAsia of Technical Services(Shenzhen) Co., Ltd. IOT Test Centre of BlueAsia,No. 448 Bulong Road, Bantian Street, Longgang District…
Text truncated - open the document above for the full version.
Model No.: XRM69DBT
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 622.00 µW |

Car Multimedia Receiver
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Digital Media Receiver
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
CD Receiver
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Car Multimedia Player
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Car Media Receiver
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter