
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
RelievrRSe post-opcomfort usermanual 2 Beforeyougetstarted Beforefirstuse,chargeyourdeviceforapproximately120minutes. TheUSBchargingcablecanbepluggedintoanyUSBportorUSB/ poweradapter(notincluded). •Charging=LEDLightFlashing •Charged=LEDLightSolid Placingthedevice 1.Whenusingthedeviceforthefirsttime,removetheprotectivefilmonthedevice. 2.Placethedeviceonyourbreastorchest,nearthepainfularea. 3.Youmayremovethewhitebackingtorevealthetackysiliconethatwillenabledirect contactwiththeskin.Alternatively,youmaykeepthebackingonandmovethedevice asneeded. UsingtheDevice 1.Oncethedeviceisinplace,startthevibrationsbypressingthepowerbuttononthe 2.Ashortpresswillstartaconstantvibration;asecondshortbuttonpresswillstarta gradualintensityvibration;athirdpresswillstartapulsationpattern.Pressingthe buttonagainwillresumetheconstantvibration. deviceforthreesecondstoturniton(ablinkingredindicatorwilllightup.) 3 RelievvrApp 1.DownloadtheRelievvrappbysearchingfor“Relievvr”ontheAppleAppstoreor GooglePlaystore. 2.Followin-appinstructionstoconnectandpair.Theappwillpromptyoutoconnectthe device,whichshouldbeeasilypaired. 3.Oncethedeviceisinplace,startthevibrationsbypressingthe“On”buttonontheapp. Youcancontroltheintensity,durationandpressurethroughtheapp,soadjustthese asrequired. 4.Theappwilldisplaydifferentvibrationmodesandoptions.Choosethemodeand intensitythatisbestsuitedtoyourneedsandadjustthesettingsasrequired. 5.BatterylevelsofyourRelievvrdevicecanbeseenintheapponcepaired. Careandmaintenance 1.Thedeviceshouldbecleanedaftereveryuse.Wipeitdownwithadampclothand storeitinacool,dryplace. 2.Thedeviceshouldbechargedaftereveryuse,soensurethatitisconnectedtoa powersourceforaminimumoftwohours. 3.Theadhesivelayercanbereusedafterrinsingwithwater.Ifthetackinessisnolonger sufficient,thebackingcanbereplacedwiththeprovidedswaps. *Caution:donotusethedeviceuntilyouareclearedtodosobyyourphysician.The deviceismadefromsiliconeandintendedforexternaluseonly.Donotuseitifyouare allergictosilicone.Donotusetheadhesivecomponentifyouhaveanadhesiveallergy. Thedeviceisnotintendedtobeusedasamedicaldeviceandisnotasubstitute forprofessionalmedicalcareoradvice.Usersshouldalwaysconsultwithaqualified healthcareproviderforanymedicalconcernsorconditions. 4 AdditionalFeatures 1.TravelLock a.Thispreventsthedevicefromaccidentallyswitchingon whennotinuse. b.Pressandholdthepowerbuttonforfivesecondstolock. TheLEDwillflashredtwice. c.Repeatforfivesecondstounlockthedevice. d.Alternatively,chargingtheitemwhilelockedwillalso deactivatethetravellock. 2.Auto-PowerOff:Thedevicewillturnoffautomaticallyif leftinstandbymodefortenminutes,toconservebattery. Alternatively,youcanpressandholdthepowerbuttonto yourdevice. VibrationPattern 45 2 3 1 Pattern01 Pattern02 Pattern03 Specifications Material Body-safeSilicone Size 79(H)x79(W)x13(D)mm Weight70g ChargingTime ≤90mins RunningTime ≥100mins Battery 330mAh 5 ECDeclarationofConformity InaccordancewithENISO17050-1:2004 We:RELIEVVR,LLC of:1StoreHillRoad,Unit82,OldWestbury,NY11568 Inaccordancewiththefollowingdirective(s) 2014/53/EURadioEquipmentDirective(RED) Herebydeclarethat: Equipment:Wirelessremotecontrolmassager Branded:RelievrRosepatentpending ModelNo:RLVR-001 Isinconformitywiththeapplicablerequirementsoftheabovedirectivesandthe followingdocuments ETSIEN301489-1V2.2.0(2017) ETSIEN300220-1V3.1.1(2017) ETSIEN300220-2V3.1.1(2017) EN62479(2010) Signed: Name: Position: Date: 》 k JonathanBank,MD President,Relievvr,LLC 4/1/23 6 Supplier’sDeclarationofConformity Brandname:Relie vr Productname:RelievvrRose Modelnumber:RLVR-001 Thisdevicecomplieswithpartof15oftheFCCRules.Operationissubjecttothefollowing twoconditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemust acceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation. Supplier’sName:Relievvr,LLC Supplier’sAddress:1StoreHillRoad,Unit82,OldWestbury,NY11568 Supplier’sE-mailaddress:[email protected] FCCStatement ThisequipmenthasbeentestedandfoundtocomplywithlimitsforaClassBdigitaldevice,pursuant topart15oftheFCCrules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmful interferenceinaresidentialinstallation.Thisequipmentgeneratesusesandcanradiateradiofrequency energyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterference toradiocommunications.However,thereisnoguaranteethatinterferencewilloccurinaparticular installation.Ifthisequipmentdoescauseharmfulinterferencetoradiooftelevisionreception,which canbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrectthe interferencebyoneormoreof thefollowingmeasures: -Reorientorrelocatethereceivingantenna. -Increasetheseparationbetweentheequipmentandreceiver. -Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiveris connected. -Consultthedealeroranexperiencedradio/TVtechnicianforhelp. ThisdevicecomplieswithFCCradiationexposurelimitssetforthforanuncontrolledenvironment. ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjectto thefollowingtwoconditions: 7 WARNINGS Theapplianceshouldnotbeusedbyindividualswhohavereducedphysical,sensory,or mentalcapabilities,orwholackexperienceandknowledge,unlesstheyareundersupervision orhavereceivedinstruction.Anypersonwhoisunabletooperatethisproductbythemselves shouldnotusethisproduct. Anypersonwhoispregnant,hasapacemaker,suffersfromdiabetes,phlebitisand/or thrombosis,whohasanincreasedriskofdevelopingbloodclots,aspins,screwsorartificial jointsorotherimplantedmedicaldevicesshouldconsultamedicalprofessionalbeforeuse. InstructionsforclassIIIappliancesstatethatitmustonlybesuppliedatSELV. Donotuseonskinthatisswollen,inflamed,blisteredorbroken. Donotuseonhead,face,stomachorosseousbodyparts.Donotusearoundthroat. Thisisnotamedicaldevice.Nomedicalclaimsarewarrantedorimpliedbytheuseofthis product. Ifyouexperienceanydiscomfortduringuse,discontinueuseimmediatelyandconsultyour healthcareprofessional. Childrenshouldnotbeallowedaccesstotheappliance. Thisappliancecontainsbatteriesthatarenon-replaceable.…
Text truncated - open the document above for the full version.
C5266091_X23_Ed.1 1/1 USAGENTLETTEROFATTESTATION USAgent: CompanyName:Relievvr,LLC ContactName:JonathanBank Address:1StoreHillRoad,Unit82,OldWestbury,NY11568 TelephoneNo:+1(516)998-8468 Email:[email protected] FRN:0034332171 TO: OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 ThisletteristoconfirmthatwehaveacceptedtheresponsibilitytoactasUSagent representativeonbehalfoftheA&HDesignGroup,Ltd. AsperUSagent,weareawareoftherequirementsinvolvedasoutlinedinFCCEquipment AuthorizationProgramintheirReportandOrderFCC22-84andtheclause§2.911Application requirements. Applicant Companyname:A&HDesignGroup,Ltd. FRN:0025153255 Granteecode:2AG2K FCCID:2AG2K-RLVR-001 ContactName:ThomasCheung Address:Suite608,TowerOne,HarbourCentre1HokCheungStreet,HungHom,Kowloon, HongKong TelephoneNo:00852-23349488 FaxNo:00852-23349488 Email:[email protected] TheApplicantacknowledgetheacceptanceofitsobligationtomaintainanagentfor serviceofprocessintheUnitedStatesfornolessthanoneyearaftereitherthe granteehaspermanentlyterminatedallmarketingandimportationoftheapplicable equipmentwithintheU.S.,ortheconclusionofanyCommission-related administrativeorjudicialproceedinginvolvingtheequipment,whicheverislater. Date:2023/10/9 Applicant’sName:ThomasCheungUSAgent’sName:JonathanBank Title:ManagerTitle:President Signature Signature
FCC ID: 2AG2K- RLVR-001 FCC ID: 2AG2K- RLVR-001 FCC ID: 2AG2K- RLVR-001 FCC ID: 2AG2K- RLVR-001
Clear sticker Black wording Batch: FCC ID: 2AG2K-RLVR-001 Imported by Remove the transparent film to replace the adhesive on your device. Next, remove white backing to stick the device to your skin. Batch: FCC ID: 2AG2K-RLVR-001 Imported by Batch: FCC ID: 2AG2K-RLVR-001 Imported by Remove the transparent film to replace the adhesive on your device. Next, remove white backing to stick the device to your skin. 30.0 mm
FCC ID: 2AG2K- RLVR-001 FCC ID: 2AG2K- RLVR-001 FCC ID: 2AG2K- RLVR-001 ANT FCC ID: 2AG2K- RLVR-001
Page 1 of 2 RF EXPOSURE EVALUATION FCC ID: 2AG2K-RLVR-001 Product Name : Massager Model Name : RLVR-001 Bluetooth Version : BLE Operating frequency : 2402-2480MHz Numbers of Channel : 40 channels For DTS Antenna Type : PCB Antenna Antenna Gain : -14.16dBi Type of Modulation : GFSK Power supply : Input: DC 5V Li-ion Battery : 502030 Rated Voltage: 3.7V Capacity: 250mAh Hardware Version : N/A Software Version : N/A Page 2 of 2 Standard Requirement According to § 15.247(i) and § 1.1307b(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. See KDB 447498 D01 General RF Exposure Guidance v06, section 4. 3. 1. The 1-g and 10-g SAR test exclusion thresholds for 100MHz to 6GHz at test separation distances ≤ 50mm are determined by: [ (max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]*[ √f(GHz)] ≤3.0 for 1-g SAR and ≤7.5 for 10-g SAR extremity SAR, where ⚫ f(GHz) is the RF channel transmit frequency in GHz ⚫ Power and distance are rounded to the nearest mW and mm before calculation ⚫ The result is rounded to one decimal place for comparison. The test exclusions are applicable only when the minimum test separation distance is ≤ 50mm and for transmission frequencies between 100MHz and 6GHz. When the minimum test separation distance is <5mm, a distance of 5mm is applied to determine SAR test exclusion. Routine SAR evaluation refers to that specifically required by § 2.1093, using measurements or computer simulation. When routine SAR evaluation is not required, portable transmitters with output power greater than the applicable low threshold require SAR evaluation to quality for TCB approval. Channel (MHz) Maximum output power (dBm) Tune up tolerance (dBm) Max Tune Up Power (mW) Distance (mm) Calculation results Limit Operating Mode 2402 3.76 3.76 ± 1 2.992265 5 0.927506 3 BLE According to KDB 447498, no stand-alone required for BT antenna, and no simultaneous SAR measurement is required. Signature Simon Pu Manager Date: 2023-08-31
ReportNo.:RFI-LAB-RF-202310-JJ05 QP030-E41 Page1of10 TestingReport CustomerName:DongguanYoujieElectronicCo,.Ltd. ProductName:Massager SampleModel:RLVR-001 ReferenceStandard:GB/T9410-2008;ANSI/IEEEStd149-1979 IssueDate:2023.10.13 Engineer:Date: Auditor:Date: Approver:Date: ReportNo.:RFI-LAB-RF-202310-JJ05 QP030-E41 Page2of10 Version VersionNo.DateDescriptionFormulateApproval A02023.10.13Forthefirsttime,formulateZkrisEason Contents 1.GeneralInformation.........................................................................................................................3 1.1Generalinformationoftestinginstitutions...........................................................................3 1.2Testingprinciple...................................................................................................................3 1.3Testequipment......................................................................................................................4 1.4Testenvironment...................................................................................................................4 1.5Statement..............................................................................................................................4 2.SampleInformation.........................................................................................................................5 2.1Clientinformation.................................................................................................................5 2.2DescriptionofEUT(S)..........................................................................................................5 2.3EUTappearance....................................................................................................................6 2.4EUTsetupphotooffreespaceOTAtesting.........................................................................6 3.TestResults.....................................................................................................................................7 3.1Teststandard.........................................................................................................................7 3.2Testuncertainty.....................................................................................................................7 3.3Testdata................................................................................................................................8 3.3.1VSWRparameters.....................................................................................................8 3.3.2VSWRdata................................................................................................................8 3.3.3Typicalfreespaceefficiencyandgain......................................................................8 3.3.4Typicalfreespaceradiationpattern...........................................................................9 (Thefollowingisblank)..............................................................................................................10 ReportNo.:RFI-LAB-RF-202310-JJ05 QP030-E41 Page3of10 1.GeneralInformation 1.1Generalinformationoftestinginstitutions Name ShenzhenRFI-LABCommunicationTechnologyCo.,Ltd. Address 10/FA,LingyunBld,LiufangRd,BaoanDistrict,SZ Tel 13682621346 E-mail [email protected] Equipment AlltheequipmentusedinthereportisfixedinZoneB,WestSideof1/F,Building1, TingweiIndustrialPark,No.6LiufangRoad,Bao'anDistrict,Shenzhen 1.2Testingprinciple ReportNo.:RFI-LAB-RF-202310-JJ05 QP030-E41 Page4of10 1.3Testequipment EquipmentModelNo.SerialNo.Manufacturer Calibration date Next calibration date OTATest System RayZone-5000 RFI-LAB-RF -D00 GTS2023.3.142025.3.13 Network Analyzer E5071C RFI-LAB-RF -D01 KEYSIGHT2023.5.112024.5.10 Network Analyzer E5071C RFI-LAB-RF -C02 KEYSIGHT2023.5.112024.5.10 1.4Testenvironment Temperature 23.9°C Humidity 58%RH Pressure 100.18kPa 1.5Statement (1)Thetestresultsinthereportareonlyapplicabletothetestedsamplesandthetestedsamples workundertheenvironmentdescribedinthereport. (2)OnlyShenzhenRFI-LABCommunicationTechnologyCo.,Ltd.havetherighttomodifythe report,andthemodificationinformationshallbeannotatedintherevisionform. (3)Anyobjectiontothisreportshallberaisedwithin30daysafterformalconfirmationofthe report. (4)Thisreportisinvalidifthereisanyevidencethatthesampleinformationprovidedisfalsified. (5)Thereportisinvalidwithoutthesignatureoftheauditorandapprover. ReportNo.:RFI-LAB-RF-202310-JJ05 QP030-E41 Page5of10 2.SampleInformation 2.1Clientinformation Name DongguanYoujieElectronicCo,.Ltd. Address No.65,YuanmaxinRoad,Yuanjiang,ChangpingTown,DongguanCity, GuangdongProvince Contacts Mr.Jiang Tel 13723505268 E-mail [email protected] Manufacturer DongguanYoujieElectronicCo,.Ltd. Manufacturer Address No.65,YuanmaxinRoad,Yuanjiang,ChangpingTown,DongguanCity, GuangdongProvince 2.2DescriptionofEUT(S) ProductName Massager SampleModel RLVR-001 AntennaSize / SerialNo. / AntennaType PCBAntenna TestItem VSWR;Antennagain;Efficiency;Radiationpattern FrequencyRange 2400-2500MHz ReceivedDate 2023.10.11 TestDate 2023.10.12 Remark / ReportNo.:RFI-LAB-RF-202310-JJ05 QP030-E41 Page6of10 2.3EUTappearance 2.4EUTsetupphotooffreespaceOTAtesting Planform Frontview ReportNo.:RFI-LAB-RF-202310-JJ05 QP030-E41 Page7of10 3.TestResults 3.1Teststandard NameParameterMethodStandardno. Mobile communication antenna Antennagain Genericspecification forantennasusedinthe mobilecommunications GB/T 9410-2008 Radiationpattern VSWR Antenna Radiationefficiency IEEEStandardTest ProceduresforAntennas ANSI/IEEEStd 149-1979 Gainanddirectivity 3.2Testuncertainty TheuncertaintywascalculatedonthebasisoftheGUMpublishedbyISO,usingthe inclusionfactorofK=2andthe95%confidenceleveltoexpresstheextended uncertainty. ItemUncertainty VSWR±0.3 Antennagain±0.72dB Radiationefficiency±0.72dB ReportNo.:RFI-LAB-RF-202310-JJ05 QP030-E41 Page8of10 3.3Testdata 3.3.1VSWRparameters 3.3.2VSWRdata 3.3.3Typicalfreespaceefficiencyandgain Frequency/MHz 2400245…
Text truncated - open the document above for the full version.
Page 1 of 55 FCC TEST REPORT FCC ID: 2AG2K- RLVR-001 Product : Massager Model Name : RLVR-001 Brand : N/A Report No. : PTC23073109006E-FC01 Prepared for A&H Design Group, Ltd. Suite 608, Tower One, Harbour Centre,1 Hok Cheung Street, Hung Hom, Kowloon, Hong Kong Prepared by Precise Testing & Certification Co., Ltd Building 1, No. 6, Tongxin Road, Dongcheng Street, Dongguan, Guangdong, China Report No.: PTC23073109006E-FC01 Page 2 of 55 1 TEST RESULT CERTIFICATION Applicant’s name : A&H Design Group, Ltd. Address : Suite 608, Tower One, Harbour Centre,1 Hok Cheung Street, Hung Hom, Kowloon, Hong Kong Manufacture's name : A&H Design Group, Ltd. Address : Suite 608, Tower One, Harbour Centre,1 Hok Cheung Street, Hung Hom, Kowloon, Hong Kong Product name : Massager Model name : RLVR-001 Standards : FCC CFR47 Part 15 Section 15.247 Test procedure : ANSI C63.10:2013 Test Date : Aug. 18, 2023 to Aug. 31, 2023 Date of Issue : Aug. 31, 2023 Test Result : Pass This device described above has been tested by PTC, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of PTC, this document may be altered or revised by PTC, personal only, and shall be noted in the revision of the document. Test Engineer: Jack zhou / Engineer Technical Manager: Simon Pu / Manager Report No.: PTC23073109006E-FC01 Page 3 of 55 Contents Page 1 TEST RESULT CERTIFICATION .............................................................................................................................. 2 2 TEST SUMMARY ......................................................................................................................................................... 5 2.1 TEST SITE ........................................................................................................................................................... 6 3 GENERAL INFORMATION ..................................................................................................................................... 7 3.1 GENERAL DESCRIPTION OF E.U.T. .................................................................................................................... 7 3.2 CHANNEL LIST .................................................................................................................................................... 8 4 EQUIPMENT DURING TEST .................................................................................................................................. 9 4.1 EQUIPMENTS LIST ............................................................................................................................................ 9 4.2 MEASUREMENT UNCERTAINTY ......................................................................................................................... 11 4.3 DESCRIPTION OF SUPPORT UNITS ................................................................................................................... 12 5 CONDUCTED EMISSION ......................................................................................................................................... 13 5.1 E.U.T. OPERATION ........................................................................................................................................... 13 5.2 EUT SETUP ...................................................................................................................................................... 13 5.3 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) .................................................................................. 14 5.4 MEASUREMENT PROCEDURE ........................................................................................................................... 14 5.5 CONDUCTED EMISSION LIMIT ........................................................................................................................... 14 5.6 MEASUREMENT DESCRIPTION .......................................................................................................................... 14 5.7 CONDUCTED EMISSION TEST RESULT ............................................................................................................. 14 6 RADIATED SPURIOUS EMISSIONS ..................................................................................................................... 17 6.1 EUT OPERATION .............................................................................................................................................. 17 6.2 TEST SETUP ..................................................................................................................................................... 18 6.3 SPECTRUM ANALYZER SETUP .......................................................................................................................... 19 6.4 TEST PROCEDURE ............................................................................................................................................ 20 6.5 SUMMARY OF TEST RESULTS .......................................................................................................................... 22 7 CONDUCT BAND EDGE AND SPURIOUS EMISSIONS MEASUREMENT ................................................... 29 7.1 TEST PROCEDURE ............................................................................................................................................ 29 7.2 TEST SETUP ..................................................................................................................................................... 29 7.3 TEST RESULT ................................................................................................................................................... 30 Report No.: PTC23073109006E-FC01 Page 4 of 55 6DB BANDWIDTH …
Text truncated - open the document above for the full version.
FCC ID: 2AG2K- RLVR-001 Conducted Emissions Radiated Spurious Emissions Test Frequency From Below 30MHz FCC ID: 2AG2K- RLVR-001 Test frequency from Above 1GHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.40 mW |

Rechargeable remote (MENAGE A TROIS REMOTE CONTROL ORGY EGG SET)
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Cowgirl Saddle Machine
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Cowgirl Grinding Vibrating & Tapping
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Anal Training Bundle
Equipment Class
DSC - Part 15 Security/Remote Control TransmitterRemote control layon vibe
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter