FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Signify (China) Investment Co., Ltd./
  3. 2AGBW9290036670X

2AGBW9290036670XLED lamp

Signify (China) Investment Co., Ltd.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 25, 2024
Application Purpose
Original Equipment
Date of Application
Mar 24, 2024
Equipment Note
LED lamp
Frequency Range
2405.00000000 - 2480.00000000
Company
Signify (China) Investment Co., Ltd.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

CFR 47 §2.911 (d)(5) Attestation Date: 2024-01-15 FRN: 0024989014 FCC ID: 2AGBW9290036670X Product Model Number: 9290036670 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA 1. Signify (China) Investment Co., Ltd. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. 2. Signify (China) Investment Co., Ltd. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment and is not an affiliate or subsidiary of an entity identified on the Covered List. Sincerely yours, Name: Yefeng Zhang Address: NO.9, Shanghai Business Park, Lane 888 Tianlin Road, Minhang District, Shanghai, P.R.C. Email: [email protected] Job Title: Validation & Approbation Group Manager Company Name: Signify (China) Investment Co., Ltd.

Attestation Statements

CFR 47 §2.911 (d)(7) FCC US Agent Letter of Attestation Date: 2024-01-15 FRN: 0024989014 FCC ID: 2AGBW9290036670X Product Model Number: 9290036670 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA FCC US Agent Agent FRN: 0024909822 Agent Company Name: Signify North America Corporation Agent Contact Name: Richard Haring Agent US Address: 10275 West Higgins Road, Rosemont, IL 60018 Agent Email Address: [email protected] This letter is to confirm that we have accepted the responsibility to act as US Agent on behalf of Signify (China) Investment Co., Ltd. (“the applicant”) for the above referenced FCC ID. We are aware of the requirements and responsibilities of the applicant’s agent for service of process as outlined in the FCC section 2.911(d)(7) and Report and Order FCC 22-84 paragraph 63. Sincerely yours, Authorized Agent Contact Person Name: Richard Haring Agent contact Job Title: Validation Engineer Agent Company name: Signify North America Corporation

Attestation Statements

CFR 47 §2.911 (d)(7) Agent Designation Attestation Date: 2024-01-15 FRN: 0024989014 FCC ID: 2AGBW9290036670X Product Model Number: 9290036670 To: Federal Communications Commission 7435 Oak land Mills Road Columbia, MD 21046 USA Signify (China) Investment Co., Ltd. (“the applicant”) as required by section 2.911(d)(7), designates the following agent, located in the United States, for purposes of acting as the applicant’s agent for service of process. The applicant acknowledges that they will maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the agent information changes. U. S. Agent Information: Contact Person: Richard Haring Company Name: Signify North America Corporation Company Address: 10275 West Higgins Road, Rosemont, IL 60018 Email: [email protected] Si ncerely yours, Name: Yefeng Zhang Job Title: Validation & Approbation Group Manager Company Name: Signify (China) Investment Co., Ltd. Email: [email protected]

Cover Letter(s)

Company Name: Signify ( China ) Investment Co., Ltd Address: Building no.9, Lane 888, Tianlin Road, Minhang district Shanghai, 200233 China Tel: +86-17701755062 Fax No.: +86-21-54452269 E- mail: yefeng.zhang @ signi fy .com FCC Authorization Date: 01/15/2024 FEDERAL COMMUNICATIONS COMMISSION Authorization and E valuation Division 7435 Oakland Mills Road Columbia , MD 2 I 046 Sub j ect: A gent A uthorization To whom it may concern: We, Signify (China) Investment Co., Ltd. , the undersigned, Hereby authorizes China Certification ICT C o.,Ltd(Dongguan) to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by China Certification ICT Co.,Ltd(Dongguan). on our behalf shall have the same effect as our own action. We , the undersigned, hereby certify that we are not sub j ect to a denial offederal benefits , that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862 This authorization is valid until further written notice from the applicant. S incerely Yours, Signature Printed Name: Yefeng Zhang Title: Approbation Group Manager Q A - FR-170-B

ID Label/Location Info

Classified

RF Exposure Info

China Certification ICT Co., Ltd (Dongguan) Report No.: CR231058896-00 Page 81 of 83 5. RF EXPOSURE EVALUATION 5.1 Applicable Standard FCC §15.247 (i) and subpart §1.1307 Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. 5.2 Procedure According to §1.1307(b)(3)(i) (C) Or using Table 1 and the minimum separation distance (R in meters) from the body of a nearby person for the frequency (f in MHz) at which the source operates, the ERP (watts) is no more than the calculated value prescribed for that frequency. For the exemption in Table 1 to apply, R must be at least λ/2π, where λ is the free-space operating wavelength in meters. If the ERP of a single RF source is not easily obtained, then the available maximum time-averaged power may be used in lieu of ERP if the physical dimensions of the radiating structure(s) do not exceed the electrical length of λ/4 or if the antenna gain is less than that of a half-wave dipole (1.64 linear value). Table 1 to § 1.1307(b)(3)(i)(C) - Single RF Sources Subject to Routine Environmental Evaluation RF Source frequency (MHz) Threshold ERP (watts) 0.3-1.34 1,920 R 2 . 1.34-30 3,450 R 2 /f 2 . 30-300 3.83 R 2 . 300-1,500 0.0128 R 2 f. 1,500-100,000 19.2R 2 . 5.3 Measurement Result Radio Frequency (MHz) λ/2Π (mm) Distance (mm) Exemption ERP (mW) Maximum Conducted Power including Tune-up Tolerance (dBm) Antenna Gain (dBi) ERP dBmmW Zigbee 2405-2480 19.87 200 768 11 -0.90 7.95 6.24 BLE 2402-2480 19.88 200 768 11 -0.90 7.95 6.24 Note: The Maximum Conducted Power including Tune-up Tolerance was declared by manufacturer. The ZigBee and BLE can`t transmission simultaneously. Result: The device compliant the MPE-Based Exemption at 20cm distances.

Test Report

TEST REPORT Applicant: Signify (China) Investment Co., Ltd. Address: Building no.9, Lane 888, Tianlin Road, Minhang District, Shanghai, 200233, China. FCC ID: 2AGBW9290036670X Product Name: LED lamp Standard(s): 47 CFR Part 15, Subpart C(15.247) ANSI C63.10-2013 KDB 558074 D01 15.247 Meas Guidance v05r02 The above device has been tested and found compliant with the requirement of the relative standards by China Certification ICT Co., Ltd (Dongguan) Report Number: CR231058896-00 Date Of Issue: 2024/1/25 Reviewed By: Calvin Chen Title: RF Engineer Approved By: Sun Zhong Title: Manager Test Laboratory: China Certification ICT Co., Ltd (Dongguan) No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China Tel: +86-769-82016888 China Certification ICT Co., Ltd (Dongguan) Report No.: CR231058896-00 Page 2 of 83 Test Facility The Test site used by China Certification ICT Co., Ltd (Dongguan) to collect test data is located on the No. 113, Pingkang Road, Dalang Town, Dongguan, Guangdong, China. The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the FCC Public Access Link (PAL) database, FCC Registration No. : 442868, the FCC Designation No. : CN1314. Declarations China Certification ICT Co., Ltd (Dongguan) is not responsible for the authenticity of any test data provided by the applicant. Data included from the applicant that may affect test results are marked with a triangle symbol “▲”. Customer model name, addresses, names, trademarks etc. are not considered data. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with an asterisk “★”. China Certification ICT Co., Ltd (Dongguan) Report No.: CR231058896-00 Page 3 of 83 CONTENTS DOCUMENT REVISION HISTORY .......................................................................................... 5 1. GENERAL INFORMATION .................................................................................................... 6 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................... 6 1.2 DESCRIPTION OF TEST CONFIGURATION ........................................................................................... 8 1.2.1 EUT Operation Condition: ............................................................................................................................. 8 1.2.2 Support Equipment List and Details .............................................................................................................. 8 1.2.3 Support Cable List and Details ...................................................................................................................... 8 1.2.4 Block Diagram of Test Setup ......................................................................................................................... 9 1.3 MEASUREMENT UNCERTAINTY ........................................................................................................ 10 2. SUMMARY OF TEST RESULTS .......................................................................................... 11 3. REQUIREMENTS AND TEST PROCEDURES .................................................................. 12 3.1 AC LINE CONDUCTED EMISSIONS .................................................................................................... 12 3.1.1 Applicable Standard ..................................................................................................................................... 12 3.1.2 EUT Setup.................................................................................................................................................... 13 3.1.3 EMI Test Receiver Setup ............................................................................................................................. 13 3.1.4 Test Procedure ............................................................................................................................................. 14 3.1.5 Corrected Amplitude & Margin Calculation ................................................................................................ 14 3.2 RADIATION SPURIOUS EMISSIONS .................................................................................................... 15 3.2.1 Applicable Standard ..................................................................................................................................... 15 3.2.2 EUT Setup.................................................................................................................................................... 15 3.2.3 EMI Test Receiver & Spectrum Analyzer Setup ......................................................................................... 16 3.2.4 Test Procedure ............................................................................................................................................. 17 3.2.5 Corrected Amplitude & Margin Calculation ................................................................................................ 17 3.3 MINIMUM 6 DB BANDWIDTH ............................................................................................................. 18 3.3.1 Applicable Standard ..................................................................................................................................... 18 3.3.2 EUT Setup.................................................................................................................................................... 18 3.3.3 Test Procedure ...................................................................................…

Text truncated - open the document above for the full version.

Test Report

Si gnify Classified - Internal 1.A ntenna test environment and procedure Test Block diagram OTA Anechoic Chamber and Its control equipment 2.Antenna model PIFA antenna Manufacture:Signify (China) Investment Co., Ltd Address:Building no.9, Lane 888, Tianlin Road, Minhang district Shanghai, 200233 China Signify Classified - Internal 3.Antenna gain The gain of horn antenna is tested, the Gain of antenna is calculated by comparing with tested horn antenna. 4.RF and antenna specification sheet Frequency Range 频率范围: 2400 ~ 2483.5MHz DATA Rate 传输速率: 250kbps (Zigbee); 1Mbps, 2Mbps, 500kbps,125kbps (BLE) Channel No. 频道数:Zigbee: 16 channels (2405MHz~ 2480MHz); BT: 40 channels (2402~2480MHz) Modulation type 调制方式: O-QPSK (Zigbee); GFSK (BLE) Max. Output Power 最大输出功率: +10dBm (Chip max RF output power) Operating Temperature 工作温度: -25 -- 100 °C ambient Antenna Gain 天线增益: -0.9 dBi (Peak) Antenna Brand & Model 天线商标&型号: PCB Antenna (PIFA antenna) 3D

Contact Information

Applicant

Yefeng Zhang(Approbation Group Manager)
[email protected]+86-17701755062Fax: +86-21-54452269

Test Firm

CHINA CERTIFICATION ICT CO., LTD (DONGGUAN)Tanie Ou
[email protected]0086 0769 86858888

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.40 GHz - 2.48 GHz11.80 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Signify (China) Investment Co., Ltd.

2AGBW-WZBLREMOTE1

Dimmer Switch

Aug 17, 2026

Equipment Class

DTS - Digital Transmission System
2AGBW9290034996X

HDMI Sync Box

Sep 01, 2024

Equipment Class

DTS - Digital Transmission System
WiZ Camera Module - FCC ID 2AGBW9290032837 - Signify (China) Investment Co., Ltd.
2AGBW9290032837

WiZ Camera Module

Nov 30, 2023

Equipment Class

DTS - Digital Transmission System
LED lamp - FCC ID 2AGBW9290035755X - Signify (China) Investment Co., Ltd.
2AGBW9290035755X

LED lamp

Jul 29, 2023

Equipment Class

DTS - Digital Transmission System
LED Device - FCC ID 2AGBW9290035353X - Signify (China) Investment Co., Ltd.
2AGBW9290035353X

LED Device

Nov 21, 2022

Equipment Class

DTS - Digital Transmission System