FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. AKUVOX (XIAMEN) NETWORKS CO., LTD./
  3. 2AHCR-S562W

2AHCR-S562WIndoor Monitor

AKUVOX (XIAMEN) NETWORKS CO., LTD.
Indoor Monitor - FCC ID 2AHCR-S562W - AKUVOX (XIAMEN) NETWORKS CO., LTD.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 24, 2024
Application Purpose
Original Equipment
Date of Application
Mar 24, 2024
Equipment Note
Indoor Monitor
Frequency Range
2412.00000000 - 2462.00000000
Company
AKUVOX (XIAMEN) NETWORKS CO., LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

โ†—

Attestation Statements

โ†—
โ†—
โ†—

Cover Letter(s)

โ†—
โ†—

External Photos

โ†—

ID Label/Location Info

โ†—

Internal Photos

โ†—

RF Exposure Info

โ†—

Test Report

โ†—
โ†—

Test Setup Photos

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

About This ManualAbout This Manual 1 S562W Thank you for choosing the Akuvox S562W series indoor monitor. This manual is intended for the administrators who need to properly configure the indoor monitor. This manual is written based on firmware 562.30.0.114, and it provides all the configurations for the functions and features of the S562W series indoor monitor. Please visit the Akuvox website or consult technical support for any new information or the latest firmware. 2 Product OverviewProduct Overview It can be connected with the Akuvox door phone for audio/video communication, unlocking, and monitoring. Residents can communicate with visitors via audio/video call, and it supports unlocking the door remotely. It is more convenient and safer for residents to check the visitor's identity through its video preview function. S562W series are often applied to scenarios such as villas, apartments, and buildings. Product OverviewProduct Overview 3 ModelModelS562S562W Touch Screenโœ” Resolution1024x600 Wi-FiIEEE 802.11 b/g/n Bluetoothร— NFCร— RS4851 Alarm In8 Model SpecificationModel Specification 4 Introduction to Configuration MenuIntroduction to Configuration Menu StatusStatus: This section gives you basic information such as product information, Network Information, and account information, etc. AccountAccount: This section concerns SIP account, SIP server, proxy server, transport protocol type, audio&video codec, DTMF, session timer, etc. NetworkNetwork: This section mainly deals with DHCP&Static IP setting, RTP port setting, and device deployment, etc. DeviceDevice: This section includes time&language, call feature, screen display, multicast, audio intercom feature, monitor, relay, lift import&export, door log, and web relay. ContactsContacts: This section allows the user to configure the local contact list stored in the device. UpgradeUpgrade: This section covers firmware upgrade, device reset&reboot, configuration file auto-provisioning, and PCAP. ArmingArming: This section covers the configuration including arming zone setting, arming mode, disarm code, and alarm action. SecuritySecurity: This section is for password modification, account status & session time out configuration, as well as service location switching. SettingsSettings: This section includes the RTSP, power output. Introduction to Configuration MenuIntroduction to Configuration Menu 5 Powered by Document360 6

Attestation Statements

AKUVOX (XIAMEN) NETWORKS CO., LTD. Add: 10/F, No.56 Guanri Road, Software Park II, Xiamen 361009, China Tel: 086-0591 -83057798 Fax: 086-0591-83057798 Email: [email protected] Attestation Letter Date: 2024-02-07 To: FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Dear Sir or Madam: Our product Indoor Monitor,, model:S562W,FCC ID:2AHCR-S562W, for marketing purpose, this product only supports 2.4G Wi-Fi(2412-2462MHz, 802.11b/g/n20 modes, 2422-2452MHz , 802.11 n40 modes).The other functions, bands and modes was disabled to use by manufacturer in the software, the end user has no capability to activate it. Sincerely, Printed Name:Bo Yang Title:Manager

Attestation Statements

ATTESTATION STATEMENT Applicant:AKUVOX (XIAMEN) NETWORKS CO., LTD. Add:10/F, No.56 Guanri Road, Software Park II, Xiamen 361009, China Tel:086-0591-83057798 Fax: 086-0591-83057798 Email:[email protected] Date: 2024-02-07 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements Part 2.911(d)(5)(i), (ii) Filing FCC ID:2AHCR-S562W AKUVOX (XIAMEN) NETWORKS CO., LTD.(โ€œthe applicantโ€) certifies that the equipment for which authorization is sought is not โ€œcoveredโ€ equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. And AKUVOX (XIAMEN) NETWORKS CO., LTD. (โ€œthe applicantโ€) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing โ€œcoveredโ€ equipment. Sincerely, Signed by (printed name):Bo Yang Signature: Manager

Attestation Statements

U.S. AGENT LETTER OF ATTESTATION Date: 2024-02-07 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 ยง2.911(d)(7) Filing FCC ID:2AHCR-S562W AKUVOX (XIAMEN) NETWORKS CO., LTD. ( โ€œthe Applicantโ€) certifies that, as of the date of the filing of the application, Iconsigh Inc. is our designated U.S. agent for service of process for the above referenced FCC ID. AKUVOX (XIAMEN) NETWORKS CO., LTD. (โ€œthe Applicantโ€) a ccepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Iconsigh Inc. accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Company Name: Iconsigh Inc. Address: 2310 Homestead Road, Suite C1, Los Altos, CA, 94024, USA FRN: 0033398652 Tel.: +1 (408) 320-9867 Email: [email protected] Signed by (printed name): Benjamin Kaur Signature: Applicant:AKUVOX (XIAMEN) NETWORKS CO., LTD. Address: 10/F, No.56 Guanri Road, Software Park II, Xiamen 361009, China FRN:0025226762 Tel: 086-0591-83057798 Email:[email protected] Signed by (printed name): Bo Yang Signature:

Cover Letter(s)

QA-FR-170-B Company: AKUVOX (XIAMEN) NETWORKS CO., LTD. Add: 10/F, No.56 Guanri Road, Software Park II, Xiamen 361009, China Tel: 086-0591-83057798 Fax: 086-0591-83057798 Email: [email protected] FCC Authorization Date: 2024-02-07 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern: We , AKUVOX (XIAMEN) NETWORKS CO., LTD., Hereby authorizes Bay Area Compliance Laboratories Corp.(Dongguan) to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by Bay Area Compliance Laboratories Corp.( Dongguan) on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Clientโ€™s signature Printed Name: Bo Yang Title: Manager

Cover Letter(s)

QA-FR-171-A AKUVOX (XIAMEN) NETWORKS CO., LTD. Add: 10/F, No.56 Guanri Road, Software Park II, Xiamen 361009, China Tel: 086-0591-83057798 Fax: 086-0591-83057798 Email: [email protected] FCC Confidential Authorization Date: 2024-02-07 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: 2AHCR-S562W In accordance with Sections 0.457 and 0.459 of the Commissionโ€™s Rules, AKUVOX (XIAMEN) NETWORKS CO., LTD. hereby requests long-term confidential treatment of information accompanying this application as outlined below: โ€ข Block Diagram โ€ข Schematics โ€ข Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely, Signature: Printed Name: Bo Yang Title: Manager

External Photos

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: XMDN231201-71888E-RF-EXP Page 1 / 4 EUT EXTERNAL PHOTOS Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: XMDN231201-71888E-RF-EXP Page 2 / 4 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: XMDN231201-71888E-RF-EXP Page 3 / 4 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: XMDN231201-71888E-RF-EXP Page 4 / 4

Internal Photos

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: XMDN231201-71888E-RF-INP Page 1 / 7 EUT INTERNAL PHOTOS Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: XMDN231201-71888E-RF-INP Page 2 / 7 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: XMDN231201-71888E-RF-INP Page 3 / 7 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: XMDN231201-71888E-RF-INP Page 4 / 7 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: XMDN231201-71888E-RF-INP Page 5 / 7 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: XMDN231201-71888E-RF-INP Page 6 / 7 Antenna Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: XMDN231201-71888E-RF-INP Page 7 / 7

RF Exposure Info

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: XMDN231201-71888E-RF-00B Report Template Version: FCC-Wi-Fi-V1.0 Page 74 of 74 APPENDIX C - RF EXPOSURE EVALUATION Applicable Standard According to subpart 15.247(i)and subpart ยง1.1310, systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commissionโ€™s guidelines. Limits for Maximum Permissible Exposure (MPE) (ยง1.1310, ยง2.1091) (B) Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (minutes) 0.3โ€“1.34 614 1.63 *(100) 30 1.34โ€“30 824/f 2.19/f *(180/fยฒ) 30 30โ€“300 27.5 0.073 0.2 30 300โ€“1500 / / f/1500 30 1500โ€“100,000 / / 1.0 30 f = frequency in MHz; * = Plane-wave equivalent power density; According to ยง1.1310 and ยง2.1091 RF exposure is calculated. Calculation formula: Prediction of power density at the distance of the applicable MPE limit S = PG/4๏ฐRยฒ = power density (in appropriate units, e.g. mW/cm 2 ); P = power input to the antenna (in appropriate units, e.g., mW); G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor, is normally numeric gain; R = distance to the center of radiation of the antenna (appropriate units, e.g., cm); Calculated Data: Frequency (MHz) Antenna Gain Conducted output power including Tune-up Tolerance Evaluation Distance (cm) Power Density (mW/cm 2 ) MPE Limit (mW/cm 2 ) (dBi) (numeric) (dBm)(mW) 2412-2462 2.5 1.78 19.00 79.43 20.00 0.03 1.0 The Conducted output power including Tune-up Tolerance provided by manufacturer Result: The device meet FCC MPE at 20 cm distance ===== END OF REPORT ====

Test Report

ๅฎข ๆˆท CUSTOMER: ๅฎขๆˆทๆ–™ๅท S562 CUSTOMER NO: ๅ“ ๅ WIFI Antenna L=85mm MHF PART NAME: ไพ›ๆ–นๆ–™ๅท WE007N.F0132.V01 SUPPLIER NO : ้€ๆ ทๆ—ฅๆœŸ Date: Qโ€œTY: ็ฆๅทžๅธ‚็€šๅฎ‡ๆญฃ่พพ็”ตๅญๆœ‰้™ๅ…ฌๅธ Word Easy Electronics Co.,Ltd. ไพ›ๆ–น็กฎ่ฎค SUPPLIER SIGNATURE APPROVAL CHECK DESIGN Hunter Luo Liu ๅฎขๆˆท็กฎ่ฎคCUSTOMER APPROVED BY APPROVAL CHIEF SUPERVISOR ๆ—ฅ ๆœŸ 2024/02/21 Date ็ผ– ๅท 24022101 File No ็‰ˆ ๆœฌ 1.0 Revision ่ง„ ๆ ผ ๆ‰ฟ ่ฎค ไนฆ SPECIFICATION FOR APPROVAL WE-RD-F01-A ๆ‰ฟ่ฎคไนฆ้กน็›ฎ่กจ NO. ๅ†… ๅฎน ๏ผˆContents๏ผ‰ ้กต ๆ•ฐ ๏ผˆNumber of Page๏ผ‰ ้กต ็  ๏ผˆPage Code๏ผ‰ 1 ๆ‰ฟ่ฎคไนฆๅฐ้ข ๏ผˆSpec Cover๏ผ‰ 1 1 2 ๆ‰ฟ่ฎคไนฆ้กน็›ฎ่กจ๏ผˆSpec Item ๏ผ‰ 1 2 3 ๅทฅ็จ‹ๆˆๅ“ๅ›พ ๏ผˆDrawing๏ผ‰ 1 3 4 ๅคฉ็บฟ่ง„ๆ ผ๏ผˆAntenna Specification๏ผ‰ 1 4 5 Sๅ‚ๆ•ฐๆต‹่ฏ• ๏ผˆS Parameter ๏ผ‰ 1 5 6 ๆ— ๆบๆต‹่ฏ• ๏ผˆPassive Test ๏ผ‰ 2 6 ~ 7 7 ๅคฉ็บฟ่พๅฐ„ๅœบๅž‹ ๏ผˆAntenna Radiation Pattern๏ผ‰ 3 8 ~ 10 8 ๅคฉ็บฟ่ฃ…้…ๅ›พ๏ผˆAntenna Profile๏ผ‰ 2 11 ~ 12 9 RoHSๆŠฅๅ‘Š๏ผˆ RoHS Test Report ๏ผ‰ ** ** 10 N/A N/A N/A 11 - - - 12 - - - ๅคฉ ็บฟ ่ง„ ๆ ผ Antenna Specification Electrical Properties Frequency 2400-2500MHz Impedance 50 Ohm Nominal V.S.W.R <1.5 Return Loss <-16dB Radiation Omni-directional Gain (Peak) 2.5dBi Polarization Linear Connector 1I-PEX Physical Properties Antenna Material FPC Cable Type O.D.1.13//L=85mm Operating Temp. -10 ~ +60 ฬŠC Storage Temp. -10 ~ +70 ฬŠC Cable Color Gray Agilent E5071C S Parameter Test // WIFI Antenna Performance Test Antenna Passive Test Passive Test For WIFI Freq (MHz) Effi (%) Effi (dB) Gain (dBi) 2400 53.6 -2.7 1.8 2410 56.1 -2.5 1.7 2420 58.5 -2.3 1.7 2430 58.4 -2.3 1.6 2440 59.2 -2.3 1.8 2450 57.1 -2.4 1.7 2460 61.3 -2.1 2.1 2470 59.1 -2.3 2.1 2480 63.8 -2.0 2.5 2490 62.6 -2.0 2.5 2500 60.1 -2.2 2.4 Antenna Radiation Pattern Device Antenna WIFI Antenna Profile Assembly Drawing WIFI Antenna

Test Report

TEST REPORT Applicant: AKUVOX (XIAMEN) NETWORKS CO., LTD. Address: 10/F, No.56 Guanri Road๏ผŒSoftware Park II , Xiamen 361009, China Product Name: Indoor Monitor FCC ID: 2AHCR-S562W Standard(s): 47 CFR Part 15, Subpart C(15.247) ANSI C63.10-2013 KDB 558074 D01 15.247 Meas Guidance v05r02 Report Number: XMDN231201-71888E-RF-00B Report Date: 2024/2/5 The above device has been tested and found compliant with the requirement of the relative standards by Bay Area Compliance Laboratories Corp. (Dongguan). Reviewed By: Gavin Xu Approved By: Ivan Cao Title: RF Engineer Title: EMC Manager Bay Area Compliance Laboratories Corp. (Dongguan) No.12, Pulong East 1 st Road, Tangxia Town, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn Note: The information marked โ–ฒ is provided by the applicant, the laboratory is not responsible for its authenticity and this information can affect the validity of the result in the test report. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This report cannot be reproduced except in full, without prior written approval of the Company. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. This report may contain data that are not covered by the accreditation scope and shall be marked with โ˜….This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: XMDN231201-71888E-RF-00B Report Template Version: FCC-Wi-Fi-V1.0 Page 2 of 74 CONTENTS DOCUMENT REVISION HISTORY ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 4 1. GENERAL INFORMATION ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 5 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 5 1.2 ACCESSORY INFORMATION ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 5 1.3 ANTENNA INFORMATION DETAILโ–ฒ ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 5 1.4 EQUIPMENT MODIFICATIONS ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 5 2. DESCRIPTION OF TEST CONFIGURATION ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 6 2.1 OPERATION FREQUENCY DETAIL ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 6 2.2 EUT OPERATION CONDITION ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 6 2.3 EUT EXERCISE SOFTWARE ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 6 2.4 SUPPORT EQUIPMENT LIST AND DETAILS ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 7 2.5 SUPPORT CABLE LIST AND DETAILS ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 7 2.6 BLOCK DIAGRAM OF TEST SETUP ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 8 2.7 TEST FACILITY ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 11 2.8 MEASUREMENT UNCERTAINTY ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 11 3. SUMMARY OF TEST RESULTS ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 12 4. REQUIREMENTS AND TEST PROCEDURES ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 13 4.1 AC LINE CONDUCTED EMISSIONS ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 13 4.1.1 Applicable Standard ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 13 4.1.2 EUT Setup๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 14 4.1.3 EMI Test Receiver Setup ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 14 4.1.4 Test Procedure ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 15 4.1.5 Corrected Amplitude & Margin Calculation ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 15 4.1.6 Test Result ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 15 4.2 RADIATION SPURIOUS EMISSIONS ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 16 4.2.1 Applicable Standard ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 16 4.2.2 EUT Setup๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 16 4.2.3 EMI Test Receiver & Spectrum Analyzer Setup ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 18 4.2.4 Test Procedure ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 18 4.2.5 Corrected Result & Margin Calculation ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 18 4.2.6 Test Result ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 18 4.3 MINIMUM 6 DB EMISSION BANDWIDTH ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 19 4.3.1 Applicable Standard ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 19 4.3.2 EUT Setup๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 19 4.3.3 Test Procedure ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 19 4.3.4 Test Result ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 19 4.4 99% OCCUPIED BANDWIDTH ๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 20 4.4.1 EUT Setup๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž๊ž 20 4.4.2 Tโ€ฆ

Text truncated - open the document above for the full version.

Test Setup Photos

Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: XMDN231201-71888E-RF-00B-TSP TEST SETUP PHOTOGRAPHS Conducted Emissions Front View-Powered by Adapter Conducted Emissions Side View-Powered by Adapter Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: XMDN231201-71888E-RF-00B-TSP Conducted Emissions Front View-Powered by PoE Conducted Emissions Side View-Powered by PoE Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: XMDN231201-71888E-RF-00B-TSP Radiated Emission 9k-30MHz Parallel View-Powered by Adapter Radiated Emission 9k-30MHz Perpendicular View-Powered by Adapter Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: XMDN231201-71888E-RF-00B-TSP Radiated Emission 9k-30MHz Ground-parallel View-Powered by Adapter Radiated Emission 30M-1GHz View -Powered by Adapter Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: XMDN231201-71888E-RF-00B-TSP Radiated Emission 9k-30MHz Parallel View-Powered by PoE Radiated Emission 9k-30MHz Perpendicular View-Powered by PoE Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: XMDN231201-71888E-RF-00B-TSP Radiated Emission 9k-30MHz Ground-parallel View-Powered by PoE Radiated Emission 30M-1GHz Front View-Powered by PoE Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: XMDN231201-71888E-RF-00B-TSP Radiated Emission Above 1GHz View-Powered by PoE

Contact Information

Applicant

Bo Yang
[email protected]086-0591-83057798Fax: 086-0591-83057798

Test Firm

Bay Area Compliance Laboratories Corp. (Dongguan)David Zhang
[email protected]0086-769-8685-8891

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz65.00 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The device has 20MHz and 40MHz bandwidths.

Other Applications from AKUVOX (XIAMEN) NETWORKS CO., LTD.

Door Phone - FCC ID 2AHCR-S535 - AKUVOX (XIAMEN) NETWORKS CO., LTD.
2AHCR-S535

Door Phone

May 27, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Access Control Terminal - FCC ID 2AHCR-A08K - AKUVOX (XIAMEN) NETWORKS CO., LTD.
2AHCR-A08K

Access Control Terminal

Apr 20, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
HyPanel Lux - FCC ID 2AHCR-RT61 - AKUVOX (XIAMEN) NETWORKS CO., LTD.
2AHCR-RT61

HyPanel Lux

Jul 07, 2024

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Door Phone - FCC ID 2AHCR-R29CV3 - AKUVOX (XIAMEN) NETWORKS CO., LTD.
2AHCR-R29CV3

Door Phone

Jan 04, 2024

Equipment Class

DTS - Digital Transmission System
Door Phone - FCC ID 2AHCR-X915SV2 - AKUVOX (XIAMEN) NETWORKS CO., LTD.
2AHCR-X915SV2

Door Phone

Dec 05, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter