Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
eng Getting started 1. Open the casing of the device by removing the screw at the bottom of the device. 2. Use the included screws to mount the back plate of the device on the wall 4. Insert batteries into the device respecting the polarities. 5. When the batteries are inserted, the Keypad will start searching (up to 15 minutes) for a Zigbee network to join. While the Keypad is searching for a Zigbee network to join, the yellow LED flashes. 6. If the scanning has timed out, a short press on the menu button inside the device will restart it. 7. After connecting the device to a network, attach the device to the back plate by hooking the device to the top of the back plate and pushing the device against the back plate. Disposal Dispose the product and batteries properly at the end of their lives. This is electronic waste which should be recycled. 1. To replace the batteries, remove the screw at the bottom of the device and open the casing. 2. Replace all four batteries inside the device, respecting the polarities. 3. Reattach the device to the backplate and reinsert the screw at the bottom of the device Battery replacement CAUTION: When removing cover for battery change - Electrostatic Discharge (ESD) can harm electronic components inside. CAUTION: RISK OF EXPLOSION IF BATTER- IES ARE REPLACED BY AN INCORRECT TYPE. DISPOSE OF THE BATTERIES IN ACCORD- ANCE WITH INSTRUCTIONS. a. b. d. e. f. g c. 8. Finally, reinsert the screw at the bottom of the device Resetting Resetting is needed if you want to connect your Keypad to another gateway or if you need to perform a factory reset to avoid abnormal behavior. STEPS FOR RESETTING 1. Open the casing of the device by removing the screw at the bottom of the device. 2. Press and hold the menu button inside the device with a thin pin – e.g. a paper clip. Fault finding and cleaning • In case of a bad or wireless weak signal, change the location of the device. Otherwise you can relocate your gateway or strengthen the signal with a smart plug. • If the search for a gateway has timed out, a short press on the button will restart it. Placement • You can place the Keypad both indoors and outdoors in 0-50 degrees °C. • Place the device, so it is easily accessible to users. • Avoid placing the device in direct sunlight. • Avoid placing the device in places exposed to direct rain. • Avoid placing moving items 40 cm or less from the Keypad, as they will activate the presence sensor. • When mounting the device outdoors, use screws rather than tape. Precautions • Do not remove the product label as it contains important information. • Be aware that electronics are sensitive to static electricity, so aim to discharge before touching, and avoid touching any components inside the device. • Do not paint the device. • Do not use tape for mounting the device outdoors. • Do not use tape for mounting if you will use the device for security purposes, as the tamper switch will not function. • When mounting with tape, make sure the surfaces are clean and dry. Product description The Keypad includes a tag reader and allows you to enable and disable an alarm system. The Keypad detects when a person is within operating distance, which will make it light up in the dark. The Keypad includes a tamper switch, making it ideal for security purposes. Version 2.1 INSTALLATION MANUAL Keypad 3. While you are holding the button down, the LED first flashes once, then two times in a row, and finally numerous times in a row. 4. Release the button while the LED is flashing numerous times in a row. 5. After you release the button, the LED shows one long flash, and the reset is completed. • When mounting with tape, the room temperature should ideally be between 21° C and 38° C and minimum 16° C. • Avoid mounting with tape on rough, porous or fibered materials such as wood or cement, as they reduce the tape bond. CAUTION: • Disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery, that can result in an explosion; • Leaving a battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas; • A battery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid or gas. 3. Alternatively, you can use the double adhesive tape to mount the backplate. Make sure to press firmly on the backplate with the tape to make it stick. Other certifications Zigbee 3.0 certified Develco Products assumes no responsibility for any errors, which may appear in this manual. Furthermore, Develco Products reserves the right to alter the hardware, software, and/ or specifications detailed herein at any time without notice, and Develco Products does not make any commitment to update the information contained herein. All the trademarks listed herein are owned by their respective owners. Distributed by Develco Products A/S Tangen 6 8200 Aarhus Denmark All rights reserved. IN ACCORDANCE WITH THE DIRECTIVES • Radio Equipment Directive (RED) 2014/53/ EU • RoHS Directive 2015/863/EU amending 2011/65/EU • REACH 1907/2006/EU + 2016/1688 CE certification The CE mark affixed to this product confirms its compliance with the European Directives which apply to the product and, in particular, its compliance with the harmonized standards and specifications. FCC statement Changes or modifications to the equipment not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Howev…
Text truncated - open the document above for the full version.
Applicant Declaration Applicant Declaration Rev:0.0 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Legal Business Name Develco Products Address Olof Palmes Alle 40 Aarhus N 8240 Denmark Grantee Code 2AHNM FCC ID 2AHNM-KEPZB110 Authorized Contact Name Peter Hansen Contact Email [email protected] Contact Phone 40522599-45 I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare; a) in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. b) in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for: (1) labeling the equipment with the exact FCC ID as specified in this application, (2) compliance statement labeling pursuant to the applicable rules, (3) compliance of the equipment with the applicable technical rules, c) if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC’s technical requirements. d) in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. e) in accordance with ISO17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements. (1) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. (2) the Applicant shall make provisions to always have a production sample available upon request by SGS, FCC and/or ISED. (3) the Applicant shall, upon request by SGS, at the Applicant’s expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f) neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a “party” for these purposes. g) the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc.(TCB) terms and conditions. Link to CFRs: https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs: https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100: https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Applicant Signature: Date: 2020-5-25 Print Name: Peter Hansen Title: RD Manager *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 4 External Photos for SZEM2002000862CR FCC ID: 2AHNM-KEPZB110 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 4 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 4 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 4
Label Location – KeyPad (KEPZB-110) Font-Point = 4 Statement size = 5.0 x 1.3 mm FCC ID + IC label size = 2.2 x 0.6 mm CE/WEEE label size = 2.5 x 1.0 mm Label material = The label is a permanently polyester label with thermo-transfer printing. Product Name = See user manual
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200200086102 Page: 1 of 7 Keny Xu EMC Laboratory Manager 1 Cover page RF Exposure Evaluation Report Application No.: SZEM2002000861CR Applicant: Develco Products Address of Applicant: Olof Palmes Alle 40, Aarhus N, 8240 Denmark Manufacturer: Develco Products Address of Manufacturer: Olof Palmes Alle 40, Aarhus N, 8240 Denmark Factory: GPV Address of Factory: 834 Moo 4ꞏ Bangpoo Industrial Estate Soi 11, 12ꞏ Sukhumvit Roadꞏ Praksaꞏ Muangꞏ Samutprakarnꞏ 10280ꞏ Thailand Equipment Under Test (EUT): Product Name: Keypad Model No.: KEPZB-110 Trade mark: Develco Products FCC ID: ZigBee KeyPad Standards: 47 CFR Part 1.1307 47 CFR Part 1.1310 47 CFR Part 2.1093 KDB447498D01 General RF Exposure Guidance v06 Date of Receipt: 2020-02-18 Date of Test: 2020-02-24 to 2020-03-04 Date of Issue: 2020-04-17 Test Result : PASS* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200200086102 Page: 2 of 7 2 Version Revision Record Version Chapter Date Modifier Remark 01 2020-04-17 Original Authorized for issue by: Bill Chen /Project Engineer Eric Fu /Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200200086102 Page: 3 of 7 3 Contents Page 1 COVER PAGE .............................................................................................................................................. 1 2 VERSION ...................................................................................................................................................... 2 3 CONTENTS .................................................................................................................................................. 3 4 GENERAL INFORMATION .......................................................................................................................... 4 4.1 GENERAL DESCRIPTION OF EUT ........................................................................................................ 4 4.2 TEST LOCATION ..................................................................................................................................... 5 4.3 TEST FACILITY ....................................................................................................................................... 5 4.4 DEVIATION FROM STANDARDS ........................................................................................................... 5 4.5 ABNORMALITIES FROM STANDARD CONDITIONS ........................................................................... 5 4.6 OTHER INFORMATION REQUESTED BY THE CUSTOMER ............................................................... 5 5 RF EXPOSURE EVALUATION .................................................................................................................... 6 5.1 RF EXPOSURE COMPLIANCE REQUIREMENT ................................................................................... 6 5.1.1 LIMITS ............................................................................................................................................. 6 5.1.2 TEST PROCEDURE ........................................................................................................................ 6 5.1.3 EUT RF EXPOSURE EVALUATION .............................................................................................. 7 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200200086102 Page: 4 of 7 4 General Information 4.1 General Description of EUT Power Supply: DC 6.0V by 1.5V x 4"AA" batteries Operation Frequency: 2405MHz to 2480MHz Modulation Type: O-QPSK Sample Type: Fixed production Number of Channels: 16 Channel Spacing: 5MHz Antenna Type: PCB Antenna Antenna Gain: 1.5dBi SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200200086102 Page: 5 of 7 4.2 Test Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong, China 518057 Telephone: +86 (0) 755 2601 2053 Fax: +86 (0) 755 2671 0594 No tests were sub-contracted. 4.3 Test Facility The test facility is recognized, certified, or accredited by the following organizations: • A2LA (Certificate No. 3816.01) SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01. • VCCI The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz, Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have been registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: G-20026, R-14188, C-12383 and T-11153 respectively. • FCC –Designation Number: CN1178 SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized as an accredited testing laboratory. Designation Number: CN1178. Test Firm Registration Number: 406779. • Innovation, Science and Economic Development Canada SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized by ISED as an accredited testing laboratory. CAB identifier: CN0006. IC#: 4620C. 4.4 Deviation from Standards None. 4.5 Abnormalities from Standard Conditions None. 4.6 Other Information Requested by the Customer None. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200200086102 Page: 6 of 7 5 RF Exposure Evaluation 5.1 RF Exposure Compliance Requirement 5.1.1 Limits According to FCC Part1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio freq…
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200200086101 Page: 1 of 55 Keny Xu EMC Laboratory Manage r TEST REPORT Application No.: SZEM2002000861CR Applicant: Develco Products Address of Applicant: Olof Palmes Alle 40, Aarhus N, 8240 Denmark Manufacturer: Develco Products Address of Manufacturer: Olof Palmes Alle 40, Aarhus N, 8240 Denmark Factory: GPV Address of Factory: 834 Moo 4ꞏ Bangpoo Industrial Estate Soi 11, 12ꞏ Sukhumvit Roadꞏ Praksaꞏ Muangꞏ Samutprakarnꞏ 10280ꞏ Thailand Equipment Under Test (EUT): EUT Name: Keypad Model No.: KEPZB-110 Trade mark: Develco Products FCC ID: 2AHNM-KEPZB110 Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2020-02-18 Date of Test: 2020-02-24 to 2020-03-04 Date of Issue: 2020-04-17 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200200086101 Page: 2 of 55 Revision Record Version Chapter Date Modifier Remark 01 2020-04-17 Original Authorized for issue by: Bill Chen /Project Engineer Eric Fu /Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200200086101 Page: 3 of 55 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Minimum 6dB Bandwidth 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.8.1 47 CFR Part 15, Subpart C 15.247a(2) Pass Conducted Peak Output Power 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.9.1 47 CFR Part 15, Subpart C 15.247(b)(3) Pass Power Spectrum Density 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.10.2 47 CFR Part 15, Subpart C 15.247(e) Pass Conducted Band Edges Measurement 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.13.3.2 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.11 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.209 & 15.247(d) Pass Radiated Spurious Emissions 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.4,6.5,6.6 47 CFR Part 15, Subpart C 15.209 & 15.247(d) Pass SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200200086101 Page: 4 of 55 3 Contents Page 1 COVER PAGE ............................................................................................................................................ 1 2 TEST SUMMARY ....................................................................................................................................... 3 3 CONTENTS ................................................................................................................................................ 4 4 GENERAL INFORMATION ........................................................................................................................ 6 4.1 DETAILS OF E.U.T. ............................................................................................................................... 6 4.2 DESCRIPTION OF SUPPORT UNITS ......................................................................................................... 6 4.3 MEASUREMENT UNCERTAINTY .............................................................................................................. 6 4.4 TEST LOCATION .................................................................................................................................... 8 4.5 TEST FACILITY ...................................................................................................................................... 8 4.6 DEVIATION FROM STANDARDS ............................................................................................................... 8 4.7 ABNORMALITIES FROM STANDARD CONDITIONS ..................................................................................... 8 5 EQUIPMENT LIST ...................................................................................................................................... 9 6 RADIO SPECTRUM TECHNICAL REQUIREMENT ............................................................................... 12 6.1 ANTENNA REQUIREMENT .................................................................................................................... 12 6.1.1 Test Requirement: ....................................................................................................................... 12 6.1.2 Conclusion ................................................................................................................................... 12 7 RADIO SPECTRUM MATTER TEST RESULTS ..................................................................................... 13 7.1 MINIMUM 6DB BANDWIDTH .................................................................................................................. 13 7.1.1 E.U.T. Operation .......................................................................................................................... 13 7.1.2 Test Setup Diagram ..................................................................................................................... 13 7.1.3 Measurement Procedure and Data............................................................................................. 13 7.2 CONDUCTED PEAK OUTPUT POWER .................................................................................................... 14 7.2.1 E.U.T. Operation .......................................................................................................................... 15 7.2.2 Test Setup Diagram ......…
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 2 Setup Photos for SZEM2002000861CR FCC ID: 2AHNM-KEPZB110 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 2 1 Photographs 1.1 Radiated Spurious Emissions Test Setup Below 1GHz Above 1GHz
No.1 Workshop, M-10, Middle Section, · Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 13.00 mW |

Window Sensor
Equipment Class
DTS - Digital Transmission System
Wireless gateway
Equipment Class
DTS - Digital Transmission System
Smart Cable
Equipment Class
DTS - Digital Transmission System
Water Leak Detector
Equipment Class
DTS - Digital Transmission System