
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
说明书SC009B英文 105g铜版纸 单黑印刷,折页形式,折后尺寸80x80mm 张文 2022.8.02 RF Exposure Statement The distance between user and products should be no less than 20cm. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
SHENZHEN GIEC DIGITAL CO., LTD Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA FCC ID: 2AHYK-SC009B To Whom It May Concern, Date: 2022-07-22 Pursuant to the provisions of the Commission's rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. 0Schematic Diagram rgjBlock Diagram rg]Operational Description In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); 0External Photos 0Test Setup Photos 01nternal Photos 0User Manual 0For 45 days, pursuant to Public Notice DA 04-1705. OR 0For 180 days pursuantto KDB 726920 001. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Yan Wang Title: Certification Engineer
铭牌贴纸 SC009(B) 2022.04.14 FCC ID2AHYK-SC009B FCC ID2AHYK-SC009B
FCC ID: 2AHYK-SC009B RF Exposure Evaluation Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposures 0.3–3.0 614 1.63 *(100) 6 3.0–30 1842/f 4.89/f *(900/f 2 ) 6 30–300 61.4 0.163 1.0 6 300–1500 f/300 6 1500–100,000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f 2 ) 30 30–300 27.5 0.073 0.2 30 300–1500 f/1500 30 1500–100,000 1.0 30 f = frequency in MHz Friis transmission formula: Pd = (Pout*G)/(4*pi*r 2 ) Where Pd = power density in mW/cm 2 , Pout = output power to antenna in mW; G = gain of antenna in linear scale, Pi = 3.1416; R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm 2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. Test Result of RF Exposure Evaluation Wifi 2.4G Channel Max output power to antenna (dBm) Output power to antenna (mW) Power Density at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 2462MHz (802.11g) 21.38 137.40 0.0563 1.0 PASS Remark: The max power density is less than MPE exempt limit, so it is compliance.
Report No.: GTS202205000101F01 Global United Technology ServicesCo., Ltd. No. 123-128, Tower A,Jinyuan BusinessBuilding, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 27798960 Page 1 of 34 Appendix for 15.247 1. Bandwidth 1.1 OBW 1.1.1 Test Result Mode TX Type Frequency (MHz) ANT 99% Occupied Bandwidth (MHz) Verdict Result 802.11b SISO 2412 1 13.312 Pass 2437 1 13.246 Pass 2462 1 13.409 Pass 802.11g SISO 2412 1 13.302 Pass 2437 1 13.274 Pass 2462 1 13.296 Pass 802.11n (HT20) SISO 2412 1 13.317 Pass 2437 1 13.253 Pass 2462 1 13.314 Pass Report No.: GTS202205000101F01 Global United Technology ServicesCo., Ltd. No. 123-128, Tower A,Jinyuan BusinessBuilding, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 27798960 Page 2 of 34 1.1.2 Test Graph 802.11b_LCH_2412MHz_Ant1 (SISO)_NTNV 802.11b_MCH_2437MHz_Ant1 (SISO)_NTNV Report No.: GTS202205000101F01 Global United Technology ServicesCo., Ltd. No. 123-128, Tower A,Jinyuan BusinessBuilding, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 27798960 Page 3 of 34 802.11b_HCH_2462MHz_Ant1 (SISO)_NTNV 802.11g_LCH_2412MHz_Ant1 (SISO)_NTNV Report No.: GTS202205000101F01 Global United Technology ServicesCo., Ltd. No. 123-128, Tower A,Jinyuan BusinessBuilding, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 27798960 Page 4 of 34 802.11g_MCH_2437MHz_Ant1 (SISO)_NTNV 802.11g_HCH_2462MHz_Ant1 (SISO)_NTNV Report No.: GTS202205000101F01 Global United Technology ServicesCo., Ltd. No. 123-128, Tower A,Jinyuan BusinessBuilding, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 27798960 Page 5 of 34 802.11n(HT20)_LCH_2412MHz_Ant1 (SISO)_NTNV 802.11n(HT20)_MCH_2437MHz_Ant1 (SISO)_NTNV Report No.: GTS202205000101F01 Global United Technology ServicesCo., Ltd. No. 123-128, Tower A,Jinyuan BusinessBuilding, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 27798960 Page 6 of 34 802.11n(HT20)_HCH_2462MHz_Ant1 (SISO)_NTNV Report No.: GTS202205000101F01 Global United Technology ServicesCo., Ltd. No. 123-128, Tower A,Jinyuan BusinessBuilding, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 27798960 Page 7 of 34 1.2 6dB BW 1.2.1 Test Result Mode TX Type Frequency (MHz) ANT 6dB Bandwidth (MHz) Verdict Result Limit 802.11b SISO 2412 1 8.596 >=0.5 Pass 2437 1 8.490 >=0.5 Pass 2462 1 8.947 >=0.5 Pass 802.11g SISO 2412 1 8.694 >=0.5 Pass 2437 1 7.895 >=0.5 Pass 2462 1 8.203 >=0.5 Pass 802.11n (HT20) SISO 2412 1 8.477 >=0.5 Pass 2437 1 8.921 >=0.5 Pass 2462 1 8.421 >=0.5 Pass Report No.: GTS202205000101F01 Global United Technology ServicesCo., Ltd. No. 123-128, Tower A,Jinyuan BusinessBuilding, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 27798960 Page 8 of 34 1.2.2 Test Graph 802.11b_LCH_2412MHz_Ant1 (SISO)_NTNV 802.11b_MCH_2437MHz_Ant1 (SISO)_NTNV Report No.: GTS202205000101F01 Global United Technology ServicesCo., Ltd. No. 123-128, Tower A,Jinyuan BusinessBuilding, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 27798960 Page 9 of 34 802.11b_HCH_2462MHz_Ant1 (SISO)_NTNV 802.11g_LCH_2412MHz_Ant1 (SISO)_NTNV Report No.: GTS202205000101F01 Global United Technology ServicesCo., Ltd. No. 123-128, Tower A,Jinyuan BusinessBuilding, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 27798960 Page 10 of 34 802.11g_MCH_2437MHz_Ant1 (SISO)_NTNV 802.11g_HCH_2462MHz_Ant1 (SISO)_NTNV Report No.: GTS202205000101F01 Global United Technology ServicesCo., Ltd. No. 123-128, Tower A,Jinyuan BusinessBuilding, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 27798960 Page 11 of 34 802.11n(HT20)_LCH_2412MHz_Ant1 (SISO)_NTNV 802.11n(HT20)_MCH_2437MHz_Ant1 (SISO)_NTNV Report No.: GTS202205000101F01 Global United Technology ServicesCo., Ltd. No. 123-128, Tower A,Jinyuan BusinessBuilding, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 27798960 Page 12 of 34 802.11n(HT20)_HCH_2462MHz_Ant1 (SISO)_NTNV Report No.: GTS202205000101F01 Global United Technology ServicesCo., Ltd. No. 123-128, Tower A,Jinyuan BusinessBuilding, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 27798960 Page 13 of 34 2. Maximum Conducted Output Power 2.1 Power 2.1.1 Test Result Mode TX Type Frequency (MHz) Maximum Peak Conducted Output Power (dBm) Verdict ANT1 Limit 802.11b SISO 2412 17.16 <=30 Pass 2437 18.83 <=30 Pass 2462 17.17 <=30 Pass 802.11g SISO 2412 16.85 <=30 Pass 2437 21.36 <=30 Pass 2462 21.38 <=30 Pass 802.11n (HT20) SISO 2412 18.88 <=30 Pass 2437 20.77 <=30 Pass 2462 20.50 <=30 Pass Note1: Antenna Gain: Ant1: 3.14dBi; Report No.: GTS202205000101F01 Global United Technology ServicesCo., Ltd. No. 123-128, Tower A,Jinyuan BusinessBuilding, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 27798960 Page 14 of 34 3. Maximum Power Spectral Density 3.1 PSD 3.1.1 Test Result Mode TX Type Frequency (MH…
Text truncated - open the document above for the full version.
Global United Technology Services Co., Ltd. Report No.: GTS202205000101F01 Authorized Signature: Robinson Luo Laboratory Manager This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 35 TEST REPORT Applicant: SHENZHEN GIEC DIGITAL CO., LTD Address of Applicant: 1st&3rd Building, No.26 Puzai Road, Pingdi, Longgang District, Shenzhen, China Manufacturer/Factory: SHENZHEN GIEC DIGITAL CO., LTD Address of Manufacturer/Factory: 1st&3rd Building, No.26 Puzai Road, Pingdi, Longgang District, Shenzhen, China Equipment Under Test (EUT) Product Name: Smart camera Model No.: SC009B FCC ID: 2AHYK-SC009B Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of sample receipt: May 11, 2022 Date of Test: May 12, 2022-July 22, 2022 Date of report issued: July 22, 2022 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTS202205000101F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A,Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 35 2 Version Version No. Date Description 00 July 22, 2022 Original Prepared By: Date: July 22, 2022 Project Engineer Check By: Date: July 22, 2022 Reviewer Report No.: GTS202205000101F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A,Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 35 3 Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2 VERSION .................................................................................................................................................. 2 3 CONTENTS .............................................................................................................................................. 3 4 TEST SUMMARY ..................................................................................................................................... 4 5 GENERAL INFORMATION ...................................................................................................................... 5 5.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 5 5.2 TEST MODE ........................................................................................................................................ 7 5.3 DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 7 5.4 DEVIATION FROM STANDARDS ............................................................................................................. 7 5.5 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................... 7 5.6 TEST FACILITY .................................................................................................................................... 7 5.7 TEST LOCATION ................................................................................................................................. 7 5.8 ADDITIONAL INSTRUCTIONS ................................................................................................................. 7 6 TEST INSTRUMENTS LIST ..................................................................................................................... 8 7 TEST RESULTS AND MEASUREMENT DATA .................................................................................... 10 7.1 ANTENNA REQUIREMENT ................................................................................................................... 10 7.2 CONDUCTED EMISSIONS ................................................................................................................... 11 7.3 CONDUCTED PEAK OUTPUT POWER .................................................................................................. 14 7.4 CHANNEL BANDWIDTH ...................................................................................................................... 15 7.5 POWER SPECTRAL DENSITY ............................................................................................................. 16 7.6 SPURIOUS EMISSION IN NON-RESTRICTED & RESTRICTED BANDS ....................................................... 17 7.6.1 Conducted Emission Method ..................................................................................................... 17 7.6.2 Radiated Emission Method ........................................................................................................ 18 8 TEST SETUP PHOTO ............................................................................................................................ 35 9 EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 35 Report No.: GTS202205000101F01 Global United Technology Services Co., Ltd. No. 123-128, Tower A,Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 35 4 Test Summary Test Item Section Result Antenna requirement FCC part 15.203/15.247 (c) Pass AC Power Line Conducted Emission FCC part 15.207 Pass Conducted Peak Output Power FCC part 15.247 (b)(3) Pass Channel Bandwidth & 99% OCB FCC part 15.247 (a)(2) Pass …
Text truncated - open the document above for the full version.
Radiated Emission Conducted Emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 137.40 mW |

GIEC HulaPods Ture Wireless Earbuds
Equipment Class
DTS - Digital Transmission System
True Wireless Earbuds
Equipment Class
DTS - Digital Transmission System
Bluetooth headset
Equipment Class
DTS - Digital Transmission System
Hubitat Elevation Hub
Equipment Class
DTS - Digital Transmission System
Bluetooth headset
Equipment Class
DTS - Digital Transmission System