FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Xhorse Electronics Co., Ltd./
  3. 2AI4T-XDPPR0

2AI4T-XDPPR0MINI PROG with Bluetooth and WiFi

Shenzhen Xhorse Electronics Co., Ltd.
MINI PROG with Bluetooth and WiFi - FCC ID 2AI4T-XDPPR0 - Shenzhen Xhorse Electronics Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 26, 2021
Application Purpose
Original Equipment
Date of Application
Jul 26, 2021
Equipment Note
MINI PROG with Bluetooth and WiFi
Frequency Range
2422.00000000 - 2462.00000000
Company
Shenzhen Xhorse Electronics Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

โ†—

Cover Letter(s)

โ†—
โ†—
โ†—
โ†—

External Photos

โ†—

ID Label/Location Info

โ†—

Internal Photos

โ†—

RF Exposure Info

โ†—
โ†—
โ†—
โ†—
โ†—
โ†—
โ†—

Test Report

โ†—
โ†—

Test Setup Photos

โ†—
โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

6.Quick Setting 6.2 Power off Press and hold ON/OFF button for 4 seconds, MINI PROG will be shut down. 6.3 Button explanation โ‘  ON/OFF button:Press ON/OFF button for 1-2 seconds to turn on MINI PROG, press and hold for 4 seconds to turn off MINI PROG. โ‘ก Start button:When MINI PROG is on and preparation is ready,press 'Start'to work. โ‘ข Page Turning button:When the screen cannot display all content, click to 'Page Turning' to view related information. โ‘ฃ Light button:After MINI PROG is connected to one of the test connectors 1, 2, and 3, if nened light press the 'Light'button, the corresponding test connector light on, press again to turn it off. < APPยทMINI PROG Home > 6.1 Press the ON/OFF button to display the boot screen. < MINI PROG boot screen > 2.Main Functions Data Storage EEPROM data read and write Module read and write Data edit MCU data read and write MINI PROG is a professional and stable, multifunction, intelligent๏ผŒflexible programming device for many different chips, support connection by smartphone, easy to use๏ผ 1.Overview 5.Appearance Type Quantity MINI PROG Push-type SOP8 1# test connector Push SOP8 wide body 2# test connector Push SOP8 3# test connector DB15 cable EEPROM Adaptor USB convert TYPE-C cable Needle Set Instructions 1 1 1 1 1 1 1 1set 1 4.Package List 3.Performance Recharing Current 1.5A Standby Time >5D Capacity 2550mAh Normal Working Hour >5H ON/OFF button Start button TYPE-C Charging Port Lithium Battery Page Turning button Light button Indicator Light LED Screen < front view >< back view >< right side view > Xhorse APP User UManual 6.5 Recharging Please use a 1.5A charger connect to the USB port for recharging MINI PROG. When charging in power-on status, the battery icon in device status information will be shown recharging status,indicator light on. When charging in power-off status, the indicator light on; after battery fully charged,device will be stopped charging automatically for protecting battery. โ‘ก There are 2 connection ways for user selection: Bluetooth or WIFI,according to the connection way, device will be connected automatically. 6.4 Connect to smartphone MINI PROG support connect to smartphone by Bluetooth or WIFI. MINI PROG has one year warranty,and it is based on the date on the transaction voucher;If do not have transaction voucher or lost it, the factory date recorded by the manufacturer will prevail. FCC statements: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or changes to this equipment. Such modifications or changes could void the userโ€™s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: โ€ Reorient or relocate the receiving antenna. โ€ Increase the separation between the equipment and receiver. โ€ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. โ€ Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure require- ment, The device can be used in portable exposure condition without restriction Federal Co mmunication Commission (FCC) Radiation Exposure Statement Power is so low that no RF exposure calculation is needed. FCC ID:2AI4T-XDPPR0 Please get in contact with dealer or scan the QR code behind the instruction,download Xhorse official APP to get after-sale and technical support. โ€ป Situations on the below can not get free repairment ยทDamage caused by not following the use instructions. ยทDamage caused by repairing or retrofiting in private. ยทDamage caused by fall,crash or inapproprate voltage. ยทDamage caused by inevitable force. ยทDamage caused by using in harsh environment or on the vehicle and ship for a long time; Get main body dirty and worn due to use. All rights reserved.Any individual or organization is forbidden to copy or spread in any form from this manual without permission. Due to product improvements, the contents of this manual may change without notice. 8.Warranty and after-sale instructions 7.Maintenance ยทDo not hit it violentlyใ€shake or throw it. ยทDo not wash main body and other parts with water or other liquid directly,and do not clean MINI PROG with wet cloth. ยทDo not place MINI PROG on high temperature, high humidity or dusty places. ยทDo not take MINI PROG apart or retrofit it in private otherwise mainboard will be damaged or battery will on fire and etc. ยทPlease keep screen,test connectors and other mian parts well and prevent sharp objects to do damage to them. โ‘  Click ใ€Connect to deviceใ€‘ from HOME page,available device serial number will be shown,according to SN๏ผŒ select proper device to connect.

Cover Letter(s)

Shenzhen Xhorse Electronics Co., Ltd. Date: 2021-07-16 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 To Whom It May Concern: The Shenzhen Xhorse Electronics Co.,Ltd., the undersigned, hereby authorizes Miss. Wendy Zhan from Shenzhen Morlab Communications Technology Co., Ltd., to act on the behalf of the Shenzhen Xhorse Electronics Co.,Ltd. solely in matters relating to the application for an FCC equipment authorization for FCC ID: 2AI4T-XDPPR0 including the signing of documents in connection with this Application. Necessary acts carried outShenzhen Morlab Communications Technology Co., Ltd.on our behalf of the ShenzhenXhorse Electronics Co.,Ltd. in connection with the Application shall have the same effect as acts of the Shenzhen Xhorse Electronics Co.,Ltd.. Shenzhen Xhorse Electronics Co.,Ltd. also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Thank you for your attention to this matter. Yours Sincerely, Signatory: Contact name:Ying Zhang Title:Certification Manager Tel:+0755-86704336 Email:[email protected] Company name: Shenzhen Xhorse Electronics Co., Ltd.

Cover Letter(s)

Shenzhen Xhorse Electronics Co., Ltd. Date:2021-07-16 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 Re: Request of Confidentiality forFCC ID: 2AI4T-XDPPR0 To Whom it may concern: Pursuant to sections 0.457 and 0.459 of Commissionโ€™s Rules(CFR 47), and Section 552(b)(4) of the Freedom of Information Act,Shenzhen Xhorse Electronics Co.,Ltd.hereby requests confidentiality and treatment of certain information accompanying this application. The materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. We are also hereby request Short-Term Confidentiality for 180 days after the grant as outlined in Public Notice DA04-1705. This provision will giveShenzhen Xhorse Electronics Co.,Ltd.temporary confidentiality ofcommercially sensitive information prior to product release. The requested Permanent and Short-Term Confidential exhibits are listed as follows: PERMANENT AND SHORT-TERM CONFIDENTIAL LIST ExhibitDescription PERMANENT 1Block Diagram 2Operational Description 3Schematics 4BOM 5Tune up procedure SHORT-TERM 6External Photos 7Internal Photos 8Test-Setup Photos 9User Manual The Applicant understands that pursuantto Rule 0.457, disclosure of this application and all accompanying documentations, where applicable, will not be made public before the date of the Grant for this application. Signatory: Name:Ying Zhang Company name:Shenzhen Xhorse Electronics Co., Ltd. Address:Floor 28, Block A, Building NO.6, international innovation Valley, Nanshan District, Shenzhen, China Tel: +0755-86704336 Email: [email protected]

Cover Letter(s)

Declaration To whom it may concern: We have declared below featured for FCC equipment authorization, Device FCC ID: 2AI4T-XDPPR0 Don't operate on Channels 13. US 2.4G channel 13 and Country code selection are disabled through proprietary software and are not user changeable Should you have any questions, please feel free to contact me. Signature : Date:2021/07/16 Contact name: Ying Zhang Title: Certification Manager Company name: Shenzhen Xhorse Electronics Co., Ltd.

Cover Letter(s)

Shenzhen Xhorse Electronics Co.,Ltd. Supplierโ€™s Declaration Of Conformity for the FCC SDoC Procedure The following Equipment adapt FCC SDoC Procedure according to FCC part 2.906 : Product Name: MINI PROG Brand Name: Xhorse Model Number: XDPPR0 Report Number: SZ20110066E01 Itโ€™s herewith confirmed to comply with the requirements of FCC Part 15 Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. It is understood that each unit marketed is identical to the device as tested, and any changes to the device that could adversely affect the emission characteristics will require retest. The following importer / responsible party in United States: Not Available at Certification Stage Company Name: N/A Company Address: N/A Telephone: N/A Fax: N/A Person is responsible for marking this declaration: Ying ZhangCertification Manager __________________________________________________________________________ Name (Full name)Position / Title 2021โ€07โ€16 __________________________________________________________________________ Legal SignatureDate

External Photos

FCC ID:2AI4T-XDPPR0 External Photos 1. EUT front view 2. EUT rear view 3. EUT left side view 4. EUT right side view 5. EUT top view 6. EUT bottom view 7. Accessories

ID Label/Location Info

Label๏ผš Location๏ผš

Internal Photos

FCC ID:2AI4T-XDPPR0 Internal Photos 1. EUT uncover view 2. Antenna view Bluetooth/Wi-Fi Antenna

RF Exposure Info

NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 1 of 43 REPORT No.๏ผšSZ20110066S01 TEST REPORT APPLICANT : Shenzhen Xhorse Electronics Co., Ltd. PRODUCT NAME : MINI PROG MODEL NAME : XDPPR0 BRAND NAME : Xhorse FCC ID : 2AI4T-XDPPR0 STANDARD(S) : FCC 47CFR Part 2(2.1093) IEEE 1528-2013 RECEIPT DATE : 2020-11-17 TEST DATE : 2021-06-04 ISSUE DATE : 2021-07-21 Edited by : Liang Yumei (Rapporteur) Approved by: Shen Junsheng (Supervisor) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 2 of 43 REPORT No.๏ผšSZ20110066S01 DIRECTORY 1. SAR Results Summary โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 5 2. Technical Information โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 6 2.1. Applicant and Manufacturer Information โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 6 2.2. Equipment Under Test (EUT) Description โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 6 2.3. Environment of Test Site/Conditions โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 7 3. Specific Absorption Rate (SAR) โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 8 3.1. Introduction โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 8 3.2. SAR Definition โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 8 4. RF Exposure Limits โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 9 4.1. Uncontrolled Environment โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 9 4.2. Controlled Environment โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 9 5. Applied Reference Documents โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 10 6. SAR Measurement System โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 11 6.1. E-Field Probe โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 12 6.2. Data Acquisition Electronics (DAE) โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 13 6.3. Robot โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 14 6.4. Measurement Server โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 14 6.5. Light Beam Unit โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 15 6.6. Phantom โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 15 6.7. Device Holder โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 16 6.8. Data Storage and Evaluation โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 17 6.9. Test Equipment Listโˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 19 7. Tissue Simulating Liquids โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 21 8. SAR System Verification โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 23 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 3 of 43 REPORT No.๏ผšSZ20110066S01 8.1. Purpose of System Performance Check โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 23 8.2. System Setup โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 23 8.3. Validation Results โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 24 9. EUT Testing Position โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 25 9.1. Hotspot Mode Exposure Position Conditions โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 25 9.2. Hand-held Evaluation โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 26 10. Measurement Procedures โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 27 10.1. Spatial Peak SAR Evaluation โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 27 10.2. Power Reference Measurement โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™ 28 10.3. Area Scan Procedures โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โˆ™โ€ฆ

Text truncated - open the document above for the full version.

RF Exposure Info

MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.๏ผšSZ20110066S01 Annex C Plots of System Performance Check Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Date: 2021.06.04 System Check_2450MHz Communication System: UID 0, CW (0); Frequency: 2450 MHz;Duty Cycle: 1:1 Medium: HSL_2450 Medium parameters used: f = 2450 MHz; ฯƒ = 1.836 S/m; ฮต r = 38.921; ฯ = 1000 kg/m 3 Ambient Temperature๏ผš23.2 ยฐC; Liquid Temperature๏ผš22.2 ยฐC DASY5 Configuration: - Probe: EX3DV4 - SN7608; ConvF(7.58, 7.58, 7.58) @ 2450 MHz; Calibrated: 2020.11.27 - Sensor-Surface: 2mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1643; Calibrated: 2020.11.30 - Phantom: Twin-SAM; Type: QD 000 P41 Ax; Serial: 2020 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7483) CW2450/Area Scan (81x101x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 18.6 W/kg CW2450/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 100.8 V/m; Power Drift = -0.02 dB Peak SAR (extrapolated) = 32.4 W/kg SAR(1 g) = 13.51 W/kg; SAR(10 g) = 6.24 W/kg Smallest distance from peaks to all points 3 dB below = 10 mm Ratio of SAR at M2 to SAR at M1 = 48.6% Maximum value of SAR (measured) = 17.2 W/kg 0 dB = 17.2 W/kg Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Date: 2021.04.29 System Check_5250MHz Communication System: UID 0, CW (0); Frequency: 5250 MHz;Duty Cycle: 1:1 Medium: HSL_5250 Medium parameters used: f = 5250 MHz; ฯƒ = 3.183 S/m; ฮต r = 36.284; ฯ = 1000 kg/m 3 Ambient Temperature๏ผš23.2 ยฐC; Liquid Temperature๏ผš22.1 ยฐC DASY5 Configuration: - Probe: EX3DV4 - SN3823; ConvF(5.28, 5.28, 5.28) @ 5250 MHz; Calibrated: 2021.01.22 - Sensor-Surface: 2mm (Mechanical Surface Detection) - Electronics: DAE4 Sn480; Calibrated: 2020.06.02 - Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7483) CW5250/Area Scan (101x101x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm Maximum value of SAR (interpolated) = 20.3 W/kg CW5250/Zoom Scan (7x7x13)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 51.63 V/m; Power Drift = -0.10 dB Peak SAR (extrapolated) = 40.7 W/kg SAR(1 g) = 8.22 W/kg; SAR(10 g) = 2.35 W/kg Smallest distance from peaks to all points 3 dB below = 7.2 mm Ratio of SAR at M2 to SAR at M1 = 54% Maximum value of SAR (measured) = 20.8 W/kg 0 dB = 20.8 W/kg Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Date: 2021.04.30 System Check_5750MHz Communication System: UID 0, CW (0); Frequency: 5750 MHz;Duty Cycle: 1:1 Medium: HSL_5750 Medium parameters used: f = 5750 MHz; ฯƒ = 3.442 S/m; ฮต r = 36.261; ฯ = 1000 kg/m 3 Ambient Temperature๏ผš23.2 ยฐC; Liquid Temperature๏ผš22.2 ยฐC DASY5 Configuration: - Probe: EX3DV4 - SN3823; ConvF(4.6, 4.6, 4.6) @ 5750 MHz; Calibrated: 2021.01.22 - Sensor-Surface: 2mm (Mechanical Surface Detection) - Electronics: DAE4 Sn480; Calibrated: 2020.06.02 - Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7483) CW5750/Area Scan (101x101x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm Maximum value of SAR (interpolated) = 22.1 W/kg CW5750/Zoom Scan (7x7x13)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm Reference Value = 47.60 V/m; Power Drift = -0.12 dB Peak SAR (extrapolated) = 45.9 W/kg SAR(1 g) = 8.35 W/kg; SAR(10 g) = 2.33 W/kg Smallest distance from peaks to all points 3 dB below = 7.4 mm Ratio of SAR at M2 to SAR at M1 = 51.3% Maximum value of SAR (measured) = 22.2 W/kg 0 dB = 22.2 W/kg

RF Exposure Info

MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.๏ผšSZ20110066S01 Annex D Plots of Maximum SAR Test Results Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Date: 2021.06.04 WLAN 2.4GHz_802.11b 1Mbps_Front Side_R_0mm_Ch12 Communication System: UID 0, WLAN 2.4GHz 802.11b (0); Frequency: 2467 MHz;Duty Cycle: 1:1 Medium: HSL_2450 Medium parameters used: f = 2467 MHz; ฯƒ = 1.83 S/m; ฮต r = 38.721; ฯ = 1000 kg/m 3 Ambient Temperature๏ผš23.2 ยฐC; Liquid Temperature๏ผš22.2 ยฐC DASY5 Configuration: - Probe: EX3DV4 - SN7608; ConvF(7.58, 7.58, 7.58) @ 2467 MHz; Calibrated: 2020.11.27 - Sensor-Surface: 2mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1643; Calibrated: 2020.11.30 - Phantom: Twin-SAM; Type: QD 000 P41 Ax; Serial: 2020 - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7483) Ch12/Area Scan (61x111x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 0.310 W/kg Ch12/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 7.474 V/m; Power Drift = 0.02 dB Peak SAR (extrapolated) = 0.536 W/kg SAR(1 g) = 0.126 W/kg; SAR(10 g) = 0.024 W/kg Smallest distance from peaks to all points 3 dB below = 3.6 mm Ratio of SAR at M2 to SAR at M1 = 42.7% Maximum value of SAR (measured) = 0.182 W/kg 0 dB = 0.182 W/kg

RF Exposure Info

MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] REPORT No.๏ผšSZ20110066S01 Annex E DASY Calibration Certificate

RF Exposure Info

Annual validation for test lab. Appendix Annual validation for Test Lab. General calibration information Date 2020.10.25 Test Laboratory ShenZhen Morlab Communications Technology Co., Ltd. Antenna serial No. D2450V2-SN:805 Antenna Parameters with Head TSL Impedance, transformed to feed point 47.04ฮฉ-2.73jฮฉ Return Loss -34.36dB General Antenna Parameters and Design Electrical Delay (one direction) 1.276 ns After long term use with 100W radiated power๏ผŒonly a slight warming of the dipole near the feed point can be measured The dipole is made of standard semirigid coaxial cable. The center conductor of the feeding line is directly connected to the second arm of the dipole. The antenna is therefore short-circuited for DC-signals. On some of the dipoles, small end caps are added to the dipole arms in order to improve matching when loaded according to the position as explained in the "Measurement Conditions" paragraph. The SAR data are not affected by this change. The overall dipole length is still according to the Standard No excessive force must be applied to the dipole arm ๏ผŒ because they might bend or the soldered connections near the feed point may be damaged . Annual validation for test lab. Test Laboratory: Shenzhen Morlab Communications Technology Co., Ltd. Date: 2020.10.25 System Check_2450MHz_Head Communication System: UID 0, CW (0); Frequency: 2450 MHz;Duty Cycle: 1:1 Medium: HSL_2450 Medium parameters used: f = 2450 MHz; ฯƒ = 1.817 S/m; ฮต r = 38.801; ฯ = 1000 kg/m 3 Ambient Temperature๏ผš23.1 ยฐC; Liquid Temperature๏ผš22.4 ยฐC DASY5 Configuration: - Probe: EX3DV4 - SN3823; ConvF(7.3, 7.3, 7.3); Calibrated: 2020.01.03; - Sensor-Surface: 2mm (Mechanical Surface Detection) - Electronics: DAE4 Sn480; Calibrated: 2020.06.02 - Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464 - Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331) CW2450/Area Scan (71x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 16.1 W/kg CW2450/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Va l ue = 89.03 V/m; Power Drift = -0.01 dB Peak SAR (extrapolated) = 26.4 W/kg SAR(1 g) = 12.4 W/kg; SAR(10 g) = 5.62 W/kg Maximum value of SAR (measured) = 14.0 W/kg 0dB=14.0 W/kg Annual validation for test lab. Appendix Impedance Measurement Plot for Head TSL

Test Report

NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 1 of 41 REPORT No.๏ผšSZ20110066W01 TEST REPORT APPLICANT : Shenzhen Xhorse Electronics Co., Ltd. PRODUCT NAME : MINI PROG MODEL NAME :XDPPR0 BRAND NAME : Xhorse FCC ID :2AI4T-XDPPR0 STANDARD(S) :47 CFR Part 15 Subpart C RECEIPT DATE : 2020-11-07 TEST DATE :2020-12-01 to 2021-04-29 ISSUE DATE :2021-07-20 Edited by: Peng Mi (Rapporteur) Approved by: Shen Junsheng (Supervisor) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 2 of 41 REPORT No.๏ผšSZ20110066W01 DIRECTORY 1. Technical Information ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 3 1.1. Applicant and Manufacturer Information ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 3 1.2. Equipment Under Test (EUT) Description ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 3 1.3. The Channel Number and Frequency ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 4 1.4. Test Standards and Results ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 5 1.5. Environmental Conditions ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 6 2. 47 CFR Part 15C Requirements ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 7 2.1. Antenna Requirement ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 7 2.2. Duty Cycle of Test Signal ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 8 2.3. Maximum Peak Conducted Output Power ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 9 2.4. Maximum Average Conducted Output Power ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 12 2.5. 6 dB Bandwidth ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 13 2.6. Conducted Spurious Emissions and Band Edge ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 16 2.7. Power Spectral Density ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 20 2.8. Conducted Emission ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 23 2.9. Restricted Frequency Bands ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 27 2.10. Radiated Emission ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 31 Annex A Test Uncertainty ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 38 Annex B Testing Laboratory Information ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 39 Change History Version Date Reason for Change 1.0 2021-07-20 First edition MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: [email protected] Page 3 of 41 REPORT No.๏ผšSZ20110066W01 1. Technical Information Note: Provide by applicant. 1.1. Applicant and Manufacturer Information Applicant: Shenzhen Xhorse Electronics Co., Ltd. Applicant Address: Floor 28, Block A, Building NO.6, international innovation Valley, Nanshan District, Shenzhen, China Manufacturer: Shenzhen Xhorse Electronics Co., Ltd. Manufacturer Address: Floor 28, Block A, Building NO.6, international innovation Valley, Nanshan District, Shenzhen, China 1.2. Equipment Under Test (EUT) Description Product Name: MINI PROG Sample No.: 2# Hardware Version: 0.0.0 Software Version: 2.0.2 Equipment Type: Bluetooth LE Bluetooth Version: 4.2 Modulation Type: GFSK Operating Frequency Range: 2402MHz - 2480MHz Antenna Type: Ceramic Antenna Antenna Gain: 1.5dBi Accessory Information: Battery Brand Name: BAK Model No.: H18650CQ Serial No.: (N/A, marked #1 by test site) Capacity: 2550.00mAh Rated Voltage: 3.60V Charge Limit: 4.20V Manufacturer: Zhengzhou BAK Battery CO.,LTD Note1: We use the dedicated software to control the EUT continuous transmission. Note2: For a more detailed description, please refer to Specification or Userโ€™s Manual supplied by the applicant and/or manufacturer. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Fax: 86-755-36698525 Http://www.morlab.cn E-mail: service@moโ€ฆ

Text truncated - open the document above for the full version.

Contact Information

Applicant

Ying Zhang
[email protected]+0755-86704336Fax: +86 0755-86704336

Test Firm

Shenzhen Morlab Communications Technology Co. Ltd.Mr. Su Feng
[email protected]+86 755 36698566

Technical Specifications

#Rule PartsFrequency RangePower Output
315C2.42 GHz - 2.46 GHz65.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is maximum peak conducted. This device supports 802.11 b/g/n20/n40 MHz channel bandwidths. SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for body-worn accessory use conditions is 0.48 W/kg, respectively.

Other Applications from Shenzhen Xhorse Electronics Co., Ltd.

Universal Remote Key - FCC ID 2AI4T-XKB5 - Shenzhen Xhorse Electronics Co., Ltd.
2AI4T-XKB5

Universal Remote Key

Aug 20, 2024

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Universal Remote Key - FCC ID 2AI4T-XSNI - Shenzhen Xhorse Electronics Co., Ltd.
2AI4T-XSNI

Universal Remote Key

Jul 15, 2024

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Universal Remote Key - FCC ID 2AI4T-XSCD - Shenzhen Xhorse Electronics Co., Ltd.
2AI4T-XSCD

Universal Remote Key

May 09, 2024

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Universal Remote Key - FCC ID 2AI4T-XEFO - Shenzhen Xhorse Electronics Co., Ltd.
2AI4T-XEFO

Universal Remote Key

Apr 18, 2024

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Universal Remote Key - FCC ID 2AI4T-XSKF2 - Shenzhen Xhorse Electronics Co., Ltd.
2AI4T-XSKF2

Universal Remote Key

Apr 17, 2024

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver